Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Small Anim Pract ; 63(5): 362-371, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34905219

RESUMO

OBJECTIVES: To determine the efficacy and adverse events of the administration of angiotensin--converting enzyme inhibitors for the management of preclinical myxomatous mitral valve disease in dogs. MATERIALS AND METHODS: A compre- hensive search using Pubmed/MEDLINE, LILACS and CAB abstracts databases was performed. Ran- domised clinical trials that assessed efficacy and adverse events of angiotensin-converting enzyme inhibitors for the management of preclinical myxomatous mitral valve disease in dogs were included. Certainty of evidence was rated using GRADE methods. RESULTS: Four randomised clinical trials were included. While safe, angiotensin-converting enzyme inhibitors administration to dogs with myxomatous mitral valve disease and cardiomegaly results in little to no difference in the risk of development congestive heart failure (high certainty of evidence; relative risk: 1.03; 95% confidence interval: 0.87 to 1.23) and may result in little to no difference in cardiovascular-related (low certainty of evidence; relative risk: 1.01; 95% confidence interval: 0.54 to 1.89) and all-cause mortality (low certainty of evidence; relative risk: 0.93; 95% confidence interval: 0.63 to 1.36). Administration of angiotensin-converting enzyme inhibitors to dogs with myxomatous mitral valve disease without cardiomegaly may result in a reduced risk of congestive heart failure development. However, the range in which the actual effect for this outcome may be, the "margin of error," indicates it might also increase the risk of congestive heart failure development (low certainty of evidence; relative risk: 0.86; 95% confidence interval: 0.54 to 1.35). CLINICAL SIGNIFICANCE: Administration of angiotensin-converting enzyme inhibitors to dogs with -preclinical myxoma- tous mitral valve disease and cardiomegaly results in little to no difference in the risk of the develop- ment of congestive heart failure and may result in little to no difference in -cardiovascular-related and all-cause mortality. The certainty of evidence of the efficacy of angiotensin-converting enzyme inhibi- tors administration to dogs without cardiomegaly was low.


Assuntos
Doenças do Cão , Insuficiência Cardíaca , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Angiotensinas/uso terapêutico , Animais , Cardiomegalia/induzido quimicamente , Cardiomegalia/tratamento farmacológico , Cardiomegalia/veterinária , Doenças do Cão/tratamento farmacológico , Cães , Insuficiência Cardíaca/veterinária , Valva Mitral
2.
Space Sci Rev ; 215(1): 12, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30880848

RESUMO

By the end of 2018, 42 years after the landing of the two Viking seismometers on Mars, InSight will deploy onto Mars' surface the SEIS (Seismic Experiment for Internal Structure) instrument; a six-axes seismometer equipped with both a long-period three-axes Very Broad Band (VBB) instrument and a three-axes short-period (SP) instrument. These six sensors will cover a broad range of the seismic bandwidth, from 0.01 Hz to 50 Hz, with possible extension to longer periods. Data will be transmitted in the form of three continuous VBB components at 2 sample per second (sps), an estimation of the short period energy content from the SP at 1 sps and a continuous compound VBB/SP vertical axis at 10 sps. The continuous streams will be augmented by requested event data with sample rates from 20 to 100 sps. SEIS will improve upon the existing resolution of Viking's Mars seismic monitoring by a factor of ∼ 2500 at 1 Hz and ∼ 200 000 at 0.1 Hz. An additional major improvement is that, contrary to Viking, the seismometers will be deployed via a robotic arm directly onto Mars' surface and will be protected against temperature and wind by highly efficient thermal and wind shielding. Based on existing knowledge of Mars, it is reasonable to infer a moment magnitude detection threshold of M w ∼ 3 at 40 ∘ epicentral distance and a potential to detect several tens of quakes and about five impacts per year. In this paper, we first describe the science goals of the experiment and the rationale used to define its requirements. We then provide a detailed description of the hardware, from the sensors to the deployment system and associated performance, including transfer functions of the seismic sensors and temperature sensors. We conclude by describing the experiment ground segment, including data processing services, outreach and education networks and provide a description of the format to be used for future data distribution. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11214-018-0574-6) contains supplementary material, which is available to authorized users.

3.
Vet J ; 241: 8-19, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30340661

RESUMO

Veterinary regional anesthesia (RA) has been rapidly increasing in popularity over the last 10 years, as evidenced by the increasing amount of literature available and the continuous development of new techniques in small animals. The introduction of new technologies such as nerve stimulation and ultrasound (which increased the objectivity and precision of the procedure) and the promising beneficial perioperative effects conferred by RA are encouraging clinicians to incorporate these techniques in their daily perioperative anesthetic and analgesic animal care. However, there is a lack of consensus regarding outcomes when RA is used, as well as outcome comparisons between regional anesthetic techniques. Further large-scale clinical studies are still necessary. This article is the first part of a two-part review of RA in small animals, and its aim is to discuss the most relevant studies in the veterinary literature, where objective methods of nerve location have been used, and to illustrate in pictures the currently used techniques for providing RA to the thoracic limb and the thorax in small animals.


Assuntos
Anestesia Local/veterinária , Membro Anterior/inervação , Bloqueio Nervoso/veterinária , Tórax/inervação , Animais
4.
Vet J ; 238: 27-40, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30103913

RESUMO

Increasing interest in using peripheral nerve blocks in small animals is evident, given the numerous studies published recently on this topic in important veterinary journals. Initially, research was focused on intraoperative analgesia to the pelvic limb, and several descriptions of lumbosacral plexus, femoral and sciatic nerve blocks have been described in studies. There is recent interest in developing techniques for somatosensory blockade of the abdominal wall. This article is the second part of a two-part review of regional anesthesia (RA) in small animals, and its aim is to discuss the most relevant studies in the veterinary literature, where objective methods of nerve location have been used, and to illustrate in pictures the currently used techniques for providing RA to the abdominal wall and the pelvic limb in small animals.


Assuntos
Parede Abdominal/cirurgia , Anestesia Local/veterinária , Membro Posterior/cirurgia , Bloqueio Nervoso/veterinária , Anestesia Local/métodos , Anestésicos , Animais , Nervo Femoral , Bloqueio Nervoso/métodos , Animais de Estimação , Nervo Isquiático
5.
Orthop Traumatol Surg Res ; 102(4): 417-21, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27052934

RESUMO

BACKGROUND: Minimising the risk of cup implantation outside the safe zone is among the objectives of navigation during total hip arthroplasty (THA). However, given the technical challenges raised by navigation when the patient is lying on the side, many surgeons still use the freehand technique. We conducted a randomised controlled trial to evaluate the new navigation system NAVEOS in the iliac plane, which is easily identified in the lateral decubitus position, with the objective of determining whether NAVEOS navigation decreased the frequency of cup implantation outside the safe zone compared to freehand cup positioning, without increasing the operative time or the frequency of complications. HYPOTHESIS: NAVEOS navigation decreases the frequency of cup positioning outside the safe zone compared to freehand positioning. MATERIAL AND METHODS: This randomised controlled trial compared cup positioning using NAVEOS navigation versus the freehand technique in patients undergoing primary THA. The safe zone was defined according to Lewinnek as 15±10° of radiological anteversion and 40±10° of radiological inclination. Cup position parameters were measured on computed tomography images obtained 3months after THA. The images were read by two independent observers who were blinded to group assignment. The primary evaluation criterion was cup position within the safe zone. RESULTS: A 1:1 randomisation scheme was used to assign 78 patients (mean age, 68years; age range, 44-91years) to NAVEOS navigation or freehand cup positioning. The two groups were comparable for age, gender distribution, body mass index, and preoperative functional scores. In the NAVEOS group, navigation was discontinued prematurely in 6 patients, because of technical difficulties (n=2) or a marked discrepancy with clinical findings (n=4); however, the intention-to-treat approach was used for the analysis. The proportion of cups in the safe zone was 67% (28/39) in the NAVEOS group and 38% (17/39) in the freehand group (P=0.012). Anteversion was within the 5-25° range for 72% (28/39) cups in the NAVEOS group and 46% (18/39) in the freehand group (P=0.021). Inclination was within the 30-50° range for 95% (37/39) of cups with NAVEOS navigation and 85% (33/39) with freehand positioning (P=0.135). The odds ratio for cup implantation outside the safe zone was significantly lower with NAVEOS compared to freehand positioning (0.54; 95% confidence interval, 0.31-0.91). Mean operative time was 74 (range, 45-115) minutes with NAVEOS navigation and 70 (range, 40-105) minutes with freehand positioning (P=0.382). Complications consisted of 1 case each of anterior dislocation and infection, both in the freehand group. DISCUSSION: Compared to freehand positioning, NAVEOS navigation significantly lowered the risk of cup positioning outside the safe zone, chiefly via improved achievement of the anteversion target. NAVEOS was not associated with increases in operative time or morbidity. LEVEL OF EVIDENCE: II, randomised controlled trial with limited statistical power.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Erros Médicos/prevenção & controle , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Posicionamento do Paciente , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Cirurgia Assistida por Computador/instrumentação , Resultado do Tratamento
6.
Orthop Traumatol Surg Res ; 101(6): 655-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26362041

RESUMO

BACKGROUND: Abnormalities in acetabular orientation can promote the development of hip osteoarthritis, femoro-acetabular impingement, or even acetabular cup malposition. The objective of the present study was to determine whether pedicle substraction osteotomy (PSO) to correct sagittal spinal imbalance affected acetabular orientation. HYPOTHESIS: PSO performed to correct sagittal spinal imbalance affects acetabular orientation by changing the pelvic parameters. MATERIALS AND METHODS: This was a descriptive study in which two observers measured the acetabular parameters on both sides in 19 patients (38 acetabula) before and after PSO for post-operative flat-back syndrome. Mean time from PSO to post-operative measurements was 19months. Measurements were taken twice at a 2-week interval, on standing images obtained using the EOS(®) imaging system and sterEOS(®) software to obtain 3D reconstructions of synchronised 2D images. Acetabular anteversion and inclination were measured relative to the vertical plane. Mean pre-PSO and post-PSO values were compared using the paired t-test, and P values lower than 0.05 were considered significant. To assess inter-observer and intra-observer reproducibility, we computed the intra-class correlation coefficients (ICCs). RESULTS: The measurements showed significant acetabular retroversion after PSO, of 7.6° on the right and 6.5° on the left (P<0.001). Acetabular inclination diminished significantly, by 4.5° on the right and 2.5° on the left (P<0.01). Inclination of the anterior pelvic plane decreased by 8.4° (P<0.01). Pelvic incidence was unchanged, whereas sacral slope increased by 10.5° (P<0.001) and pelvic tilt decreased by 10.9° (P<0.001). The ICC was 0.98 for both inter-observer and intra-observer reproducibility. CONCLUSION: Changing the sagittal spinal alignment modifies both the pelvic and the acetabular parameters. PSO significantly increases sacral slope, thus inducing anterior pelvic tilt with significant acetabular retroversion. The measurements obtained using sterEOS(®) showed good inter-observer and intra-observer reproducibility. To our knowledge, this is the first study of changes in acetabular version after PSO.


Assuntos
Acetábulo/diagnóstico por imagem , Retroversão Óssea/etiologia , Vértebras Lombares/cirurgia , Osteotomia , Complicações Pós-Operatórias , Doenças da Coluna Vertebral/cirurgia , Adulto , Idoso , Retroversão Óssea/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Doenças da Coluna Vertebral/etiologia
7.
Orthop Traumatol Surg Res ; 101(5): 543-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26164542

RESUMO

INTRODUCTION: The management of tumors located in the posterior compartment of the knee, whatever the nature of the tumor, remains surgical excision and can be done by open surgery or under arthroscopic control. The objective of this study was to evaluate the arthroscopic management of intra-articular tumors of the posterior compartment of the knee. The hypothesis is that tumors or tumor-like lesions confined to the posterior compartment are accessible by arthroscopy with low iatrogenic risk. MATERIALS AND METHODS: All patients with an intra-articular tumor of the posterior compartment of the knee were enrolled between 2009 and 2013. The surgical management consisted of arthroscopic resection. Patients underwent postoperative MRI, repeated at last follow-up. The outcomes were the occurrence of complications, functional evaluation using the Lysholm Knee Scoring Scale, and the recurrence rate. RESULTS: Fifteen patients were included. All patients had a complete resection. One case of delayed healing of the arthroscopic entry point was observed. At a mean 22months, the mean Lysholm Knee Score increased from 74 (±8.5) preoperatively to 92 (±7.7) postoperatively, a significant increase of 18 points (P=0.001). One patient had a recurrence of osteochondromatosis, requiring removal of a foreign body. DISCUSSION: Resection of posterior intra-articular tumors of the knee using arthroscopy is possible, subject to a learning curve.


Assuntos
Artroscopia , Neoplasias Ósseas/cirurgia , Articulação do Joelho/cirurgia , Cisto Sinovial/cirurgia , Sinovite/cirurgia , Adolescente , Adulto , Feminino , Hemangioma/cirurgia , Humanos , Escore de Lysholm para Joelho , Masculino , Pessoa de Meia-Idade , Osteocondromatose/cirurgia , Adulto Jovem
8.
Orthop Traumatol Surg Res ; 101(3): 271-5, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25842249

RESUMO

INTRODUCTION: Acetabular component navigation classically requires palpation of the bone landmarks defining the anterior pelvic plane (APP) (anterior superior iliac spine [ASIS] and pubis), the recording of which is not very reliable when performed in lateral decubitus. The objectives of the current experimental study were: (1) to assess the clinical feasibility of NAVEOS navigation (based on EOS imaging) in lateral decubitus; and (2) to compare precision versus classical APP-based navigation (NAVAPP). HYPOTHESIS: Iliac plane navigation using EOS is as reliable as APP navigation. PATIENTS AND METHODS: A continuous prospective series of 13 total hip replacements were implanted in lateral decubitus under APP-guided navigation (NAVAPP). Planning used preoperative EOS measurement. The ASIS, pubis and ipsilateral posterior superior iliac spine (PSIS) were located and exported to the navigator. Intra-operatively, NAVEOS landmarks (acetabular center, ASIS and PSIS on the operated side) were palpated. Postoperatively, cup inclination and anteversion with respect to the APP were measured on EOS imaging (SterEOS3D software). The SterEOS3D measurements were compared to those of the performed NAVAPP and simulated NAVEOS navigations. RESULTS: Three patients were excluded for technical reasons. In the remaining 10, inclination on NAVAPP and SterEOS3D differed by a median 4° (range, 0-12°), and on NAVEOS versus SteEOS3D by 5° (range, 2-10°); anteversion on NAVAPP and SterEOS3D differed by a median 4.5° (range, 0-12°), and on NAVEOS versus SteEOS3D by 4° (range, 0-14°). CONCLUSION: Precision was comparable between NAVEOS and classical navigation. NAVEOS simplifies cup navigation in lateral decubitus on initial acquisition. These results require validation on a larger sample.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Imageamento Tridimensional , Cirurgia Assistida por Computador/métodos , Idoso , Pontos de Referência Anatômicos , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Estudos Prospectivos , Osso Púbico , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA