Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Aerosol Med Pulm Drug Deliv ; 27(3): 178-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23668548

RESUMO

BACKGROUND: Inhaled cyclosporine (CsA) is being investigated as a prophylaxis for lung transplant rejection. Lung deposition and systemic exposure of nebulized CsA in lung transplant patients was evaluated as part of the Phase 3 cyclosporine inhalation solution (CIS) trial (CYCLIST). METHODS: Ten patients received 300 mg of CIS (62.5 mg/mL CsA in propylene glycol) admixed with 148 MBq of Tc-DTPA (technetium-99m bound to diethylenetriaminepentaacetic acid) administered using a Sidestream(®) disposable jet nebulizer. Deposition was assessed using a dual-headed gamma camera. Blood samples were collected over a 24-hr time period after aerosol dosing and analyzed for CsA levels. A pharmacokinetic analysis of the resulting blood concentration versus time profiles was performed. RESULTS: The average total deposited dose was 53.7 ± 12.7 mg. Average pulmonary dose was 31.8 ± 16.3 mg, and stomach dose averaged 15.5 ± 11.1 mg. Device performance was consistent, with breathing maneuvers influencing dose variation. Predose coaching with five of 10 patients reduced stomach deposition (22.6 ± 11.2 vs. 8.3 ± 5.2 mg; p=0.03). Blood concentrations declined quickly from a maximum of 372 ± 140 ng/mL to 15.3 ± 9.7 ng/mL at 24 hr post dose. Levels of AUC(0-24) [area under the concentration vs. time curve from 0 to 24 hr] averaged 1,493 ± 746 ng hr/mL. On a three times per week dose regimen, this represents <5% of the weekly systemic exposure of twice per day oral administration. CONCLUSIONS: Substantial doses of CsA can be delivered to the lungs of lung transplant patients by inhaled aerosol. Systemic levels are small relative to typical oral CsA administration.


Assuntos
Ciclosporina/administração & dosagem , Ciclosporina/farmacocinética , Imunossupressores/administração & dosagem , Imunossupressores/farmacocinética , Transplante de Pulmão , Pulmão/metabolismo , Pulmão/cirurgia , Nebulizadores e Vaporizadores , Administração por Inalação , Adulto , Aerossóis , Idoso , Ciclosporina/sangue , Esquema de Medicação , Monitoramento de Medicamentos , Humanos , Imunossupressores/sangue , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Pessoa de Meia-Idade , Ohio , Pennsylvania , Cintilografia , Compostos Radiofarmacêuticos , Pentetato de Tecnécio Tc 99m , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA