Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(15): 152501, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38683002

RESUMO

We report the first mass measurement of the proton-halo candidate ^{22}Al performed with the low energy beam ion trap facility's 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. ^{22}Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of ^{22}Al, Phys. Rev. Lett. 125, 192503 (2020).PRLTAO0031-900710.1103/PhysRevLett.125.192503]. The measured mass excess value of ME=18 092.5(3) keV, corresponding to an exceptionally small proton separation energy of S_{p}=100.4(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from sd-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the ^{22}Al ground state with minimal 1s_{1/2} occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

2.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815423

RESUMO

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

3.
Phys Rev Lett ; 123(23): 239905, 2019 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-31868474

RESUMO

This corrects the article DOI: 10.1103/PhysRevLett.120.032701.

4.
Phys Rev Lett ; 120(3): 032701, 2018 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-29400535

RESUMO

We report the mass measurement of ^{56}Cu, using the LEBIT 9.4 T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory at Michigan State University. The mass of ^{56}Cu is critical for constraining the reaction rates of the ^{55}Ni(p,γ) ^{56}Cu(p,γ) ^{57}Zn(ß^{+}) ^{57}Cu bypass around the ^{56}Ni waiting point. Previous recommended mass excess values have disagreed by several hundred keV. Our new value, ME=-38626.7(7.1) keV, is a factor of 30 more precise than the extrapolated value suggested in the 2012 atomic mass evaluation [Chin. Phys. C 36, 1603 (2012)CPCHCQ1674-113710.1088/1674-1137/36/12/003], and more than a factor of 12 more precise than values calculated using local mass extrapolations, while agreeing with the newest 2016 atomic mass evaluation value [Chin. Phys. C 41, 030003 (2017)CPCHCQ1674-113710.1088/1674-1137/41/3/030003]. The new experimental average, using our new mass and the value from AME2016, is used to calculate the astrophysical ^{55}Ni(p,γ) and ^{56}Cu(p,γ) forward and reverse rates and perform reaction network calculations of the rp process. These show that the rp-process flow redirects around the ^{56}Ni waiting point through the ^{55}Ni(p,γ) route, allowing it to proceed to higher masses more quickly and resulting in a reduction in ashes around this waiting point and an enhancement to higher-mass ashes.

5.
Artigo em Inglês | MEDLINE | ID: mdl-32201753

RESUMO

The difference in the mean-square nuclear charge radius of xenon isotopes was measured utilizing a method based on extreme ultraviolet spectroscopy of highly charged Na-like ions. The isotope shift of the Na-like D1 (3s 2 S 1/2 - 3p 2 P 1/2) transition between the 124Xe and 136Xe isotopes was experimentally determined using the electron-beam ion-trap facility at the National Institute of Standards and Technology. The mass-shift and the field-shift coefficients were calculated with enhanced precision by the relativistic many-body perturbation theory and multiconfiguration Dirac-Hartree-Fock method. The mean-square nuclear charge radius difference was found to be δ〈r 2〉136,124 = 0.269(42) fm2. Our result has smaller uncertainty than previous experimental results and agrees with the literature values.

6.
Phys Rev Lett ; 116(1): 012501, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26799013

RESUMO

We report the determination of the Q(EC) value of the mirror transition of (11)C by measuring the atomic masses of (11)C and (11)B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated Ft value. Using the new value, Q(EC)=1981.690(61) keV, the uncertainty on Ft is no longer dominated by the uncertainty on the Q(EC) value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

7.
Phys Rev Lett ; 114(23): 232502, 2015 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-26196795

RESUMO

We report the first direct measurement of the (14)O superallowed Fermi ß-decay QEC value, the last of the so-called "traditional nine" superallowed Fermi ß decays to be measured with Penning trap mass spectrometry. (14)O, along with the other low-Z superallowed ß emitter, (10)C, is crucial for setting limits on the existence of possible scalar currents. The new ground state QEC value, 5144.364(25) keV, when combined with the energy of the 0(+) daughter state, Ex(0(+))=2312.798(11) keV [F. Ajzenberg-Selove, Nucl. Phys. A523, 1 (1991)], provides a new determination of the superallowed ß-decay QEC value, QEC(sa)=2831.566(28) keV, with an order of magnitude improvement in precision, and a similar improvement to the calculated statistical rate function f. This is used to calculate an improved Ft value of 3073.8(2.8) s.

8.
Phys Rev Lett ; 109(20): 202503, 2012 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-23215476

RESUMO

We report on direct time-of-flight based mass measurements of 16 light neutron-rich nuclei. These include the first determination of the masses of the Borromean drip-line nuclei (19)B, (22)C, and (29)F as well as that of (34)Na. In addition, the most precise determinations to date for (23)N and (31)Ne are reported. Coupled with recent interaction cross-section measurements, the present results support the occurrence of a two-neutron halo in (22)C, with a dominant ν2s(1/2)(2) configuration, and a single-neutron halo in (31)Ne with the valence neutron occupying predominantly the 2p(3/2) orbital. Despite a very low two-neutron separation energy the development of a halo in (19)B is hindered by the 1d(5/2)(2) character of the valence neutrons.

9.
Rev Sci Instrum ; 83(2): 02A340, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380187

RESUMO

The Van de Graaff accelerator at IRMM works since many years providing proton, deuteron, and helium beams for nuclear data measurements. The original ion source was of RF type with quartz bottle. This kind of source, as well known, needs regular maintenance for which the accelerator tank must be completely opened. The heavy usage at high currents of the IRMM accelerator necessitated an opening about once every month. In 2010, the full permanent magnet Microgan electron cyclotron resonance (ECR) ion source from PANTECHNIK was installed into a new terminal platform together with a solid state amplifier of 50 W, a dedicated dosing system for 4 gases (with respective gas bottles H(2), D(2), He, and Ar), and a set of dedicated power supplies and electronic devices for the remote tuning of the source. The new system shows a very stable behaviour of the produced beam allowing running the Van de Graaf without maintenance for several months. This contribution will describe the full installed system in details (working at high pressure in the terminal, spark effects, and optic of the extraction), as well as beam results in dc or pulsed mode.

10.
Rev Sci Instrum ; 83(2): 02A344, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380191

RESUMO

The new ECR ion source PantechniK Indian Superconducting Ion Source (PKISIS) was recently commissioned at Pantechnik. Three superconducting coils generate the axial magnetic field configuration, while the radial magnetic field is done with the multi-layer permanent magnets. Special care was devoted to the design of the hexapolar structure, allowing a maximum magnetic field of 1.32 T at the wall of the 82 mm diameter plasma chamber. The three superconducting coils using low temperature superconducting wires are cooled by a single double stage cryo-cooler (4.2 K). Cryogen-free technology is used, providing reliability and easy maintenance at low cost. The maximum installed RF power (18.0 GHz) is of 2 kW. Metallic beams can be produced with an oven (T(max) = 1400 °C) installed with an angle of 5° with respect to the source axis or a sputtering system, mounted on the axis of the source. The beam extraction system is constituted of three electrodes in accel-decel configuration. The new source of Pantechnik is conceived for reaching optimum performances at 18 GHz RF frequencies. PKISIS magnetic fields are 2.1 T axial B(inj) and 1.32 T radial field in the wall, variable B(min) with an independent coil and a large and opened extraction region. Moreover, PKISIS integrates modern design concepts, like RF direct injection (2 kW availability), dc-bias moving disk, out-of-axis oven and axial sputtering facility for metal beams. Finally, PKISIS is also conceived in order to operate in a high-voltage platform with minor power consumption.

11.
Phys Rev Lett ; 100(11): 112501, 2008 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-18517778

RESUMO

The possibility of observing neutrinoless double beta decay offers the opportunity of determining the effective neutrino mass if the nuclear matrix element were known. Theoretical calculations are uncertain, and measurements of the occupations of valence orbits by nucleons active in the decay can be important. The occupation of valence neutron orbits in the ground states of 76Ge (a candidate for such decay) and 76Se (the daughter nucleus) were determined by precisely measuring cross sections for both neutron-adding and removing transfer reactions. Our results indicate that the Fermi surface is much more diffuse than in theoretical calculations. We find that the populations of at least three orbits change significantly between these two ground states while in the calculations, the changes are confined primarily to one orbit.

12.
Rev Sci Instrum ; 79(2 Pt 2): 02A904, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315159

RESUMO

In the framework of the production of radioactive ion beams by the isotope separator online method, a new system has been developed at GANIL/SPIRAL I to produce multicharged alkali ions. The principle, referred to as the "direct 1+/N+ method," consists of a surface ionization source associated with a multicharged electron-cyclotron-resonance ion source without an intermediate mass separator. This new system has been tested online using a (48)Ca primary beam at 60.3 A MeV. The experimental evidence of the direct 1+/N+ process has been obtained for a potential difference between the two sources of 11 V and with a 1+/N+ charge breeding efficiency of 0.04% for (47)K(5+). This value is significantly lower than the value of 6% obtained for stable K ions with the standard 1+/N+ method. A possible explanation is given in the text.

13.
Phys Rev Lett ; 99(25): 252501, 2007 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-18233516

RESUMO

The root-mean-square (rms) nuclear charge radius of 8He, the most neutron-rich of all particle-stable nuclei, has been determined for the first time to be 1.93(3) fm. In addition, the rms charge radius of 6He was measured to be 2.068(11) fm, in excellent agreement with a previous result. The significant reduction in charge radius from 6He to 8He is an indication of the change in the correlations of the excess neutrons and is consistent with the 8He neutron halo structure. The experiment was based on laser spectroscopy of individual helium atoms cooled and confined in a magneto-optical trap. Charge radii were extracted from the measured isotope shifts with the help of precision atomic theory calculations.

14.
Phys Rev Lett ; 95(10): 102501, 2005 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-16196923

RESUMO

The masses of the radioactive nuclei (46)V and its decay daughter (46)Ti have been measured with the Canadian Penning Trap on-line Penning trap mass spectrometer to a precision of 1 x 10(-8). A Q(EC) value of 7052.90(40) keV for the superallowed beta decay of (46)V is obtained from the difference of these two masses. With this precise Q value, the Ft value for this decay is determined with improved precision. An investigation of an earlier Q-value measurement for (46)V uncovers a set of 7 measurements that cannot be reconciled with modern data and affects previous evaluations of V(ud) from superallowed Fermi decays. A new evaluation, adding our new data and removing the discredited subset, yields new values for G(V) and V(ud). When combined with recent results for V(us), this yields modified constraints for the unitarity of the Cabibbo-Kobayashi-Maskawa matrix and other extensions of the standard model.

15.
Ann Ig ; 16(6): 811-5, 2004.
Artigo em Italiano | MEDLINE | ID: mdl-15697010

RESUMO

In this paper the history of the thermal water of Alì Terme (Sicily-Italy) and their beneficial effects are reported. Chemical and bacteriological investigations have been conducted for assay of thermophiles sulphur bacteria. As regards the chemical characteristics, traditional investigations have been carried out together with determination of H2S.


Assuntos
Balneologia , Águas Minerais , Microbiologia da Água , Balneologia/história , História do Século XIX , Humanos , Itália , Águas Minerais/análise , Estações do Ano
16.
Boll Chim Farm ; 142(3): 102-4, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12806826

RESUMO

In this paper a new non isothermic method for the determination of the release drug rate constant (k) from a transdermal delivery system is proposed. The new method was applied to transdermal patches Trans-Ver-Sal. The results obtained prove to be able to release salicylic acid of transdermal system and the effectiveness of the new method propose.


Assuntos
Administração Cutânea , Sistemas de Liberação de Medicamentos , Algoritmos , Calibragem , Ácido Salicílico/administração & dosagem , Ácido Salicílico/farmacocinética , Solubilidade , Espectrofotometria Ultravioleta
17.
Boll Chim Farm ; 142(2): 51-3, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12705090

RESUMO

The pseudo-first order rate constant for the hydrolysis of rolitetracycline as a function of temperature was obtained by performing variable-temperature kinetic experiments. The results are in agreement with those obtained at constant-parameter kinetics but saving experimental time and chemicals.


Assuntos
Antibacterianos/análise , Rolitetraciclina/análise , Algoritmos , Hidrólise , Cinética , Espectrofotometria Ultravioleta , Temperatura
18.
J Pharm Sci ; 90(3): 270-4, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11170020

RESUMO

The complete pH-rate profile of the hydrolysis reaction of aspirin, requiring many experiments in the past, was obtained by a single variable-parameter kinetic experiment carried out by varying the hydrogen ion concentration. The experiment was carried out spectrophotometrically, reading automatically absorbance, pH, and temperature inside the reaction vessel. The results obtained by the fast processing of the kinetic profile are identical to those obtained under the same conditions but using traditional constant-pH kinetic runs. This method provides the possibility of reducing the amount of time and chemicals usually spent in collecting kinetic data in such mechanistic studies by nearly two orders of magnitude.


Assuntos
Aspirina/química , Concentração de Íons de Hidrogênio , Cinética , Hidrólise , Espectrofotometria
20.
New Microbiol ; 22(2): 91-8, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10322607

RESUMO

Wild, pigmented strains of Serratia marcescens and their non-pigmented mutants were compared on the basis of fatty acid profiles and lipid content. Classic biochemical tests show only minor differences, as well as fatty acid ratio C18:C16. The total amount of lipid synthesized and the saturated/unsaturated fatty acids ratio disclose a sharp total lipid reduction and a high percentage of unsaturated fatty acids in the pigmented strains, placing them in separated clusters compared with the nonpigmented mutants. It is hypothesized that the synthesis of the polyacetate required for the completion of the prodigiosin molecule may result in waste of methyl groups and thus affect the total amount of lipids.


Assuntos
Ácidos Graxos/análise , Pigmentos Biológicos/biossíntese , Prodigiosina/biossíntese , Serratia marcescens/metabolismo , Cromatografia Gasosa , Serratia marcescens/química , Espectroscopia de Infravermelho com Transformada de Fourier
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA