Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
2.
Circ Arrhythm Electrophysiol ; 17(5): e012517, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38666379

RESUMO

BACKGROUND: Sacubitril/valsartan (Sac/Val) is superior to angiotensin-converting enzyme inhibitors in reducing the risk of heart failure hospitalization and cardiovascular death, but its mechanistic data on myocardial scar after myocardial infarction (MI) are lacking. The objective of this work was to assess the effects of Sac/Val on inflammation, fibrosis, electrophysiological properties, and ventricular tachycardia inducibility in post-MI scar remodeling in swine. METHODS: After MI, 22 pigs were randomized to receive ß-blocker (BB; control, n=8) or BB+Sac/Val (Sac/Val, n=9). The systemic immune response was monitored. Cardiac magnetic resonance data were acquired at 2-day and 29-day post MI to assess ventricular remodeling. Programmed electrical stimulation and high-density mapping were performed at 30-day post MI to assess ventricular tachycardia inducibility. Myocardial samples were collected for histological analysis. RESULTS: Compared with BB, BB+Sac/Val reduced acute circulating leukocytes (P=0.009) and interleukin-12 levels (P=0.024) at 2-day post MI, decreased C-C chemokine receptor type 2 expression in monocytes (P=0.047) at 15-day post MI, and reduced scar mass (P=0.046) and border zone mass (P=0.043). It also lowered the number and mass of border zone corridors (P=0.009 and P=0.026, respectively), scar collagen I content (P=0.049), and collagen I/III ratio (P=0.040). Sac/Val reduced ventricular tachycardia inducibility (P=0.034) and the number of deceleration zones (P=0.016). CONCLUSIONS: After MI, compared with BB, BB+Sac/Val was associated with reduced acute systemic inflammatory markers, reduced total scar and border zone mass on late gadolinium-enhanced magnetic resonance imaging, and lower ventricular tachycardia inducibility.


Assuntos
Aminobutiratos , Compostos de Bifenilo , Cicatriz , Modelos Animais de Doenças , Combinação de Medicamentos , Infarto do Miocárdio , Miocárdio , Taquicardia Ventricular , Valsartana , Remodelação Ventricular , Animais , Valsartana/farmacologia , Aminobutiratos/farmacologia , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/patologia , Cicatriz/fisiopatologia , Cicatriz/etiologia , Cicatriz/patologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/metabolismo , Remodelação Ventricular/efeitos dos fármacos , Compostos de Bifenilo/farmacologia , Miocárdio/patologia , Miocárdio/metabolismo , Anti-Inflamatórios/farmacologia , Tetrazóis/farmacologia , Fibrose , Suínos , Antiarrítmicos/farmacologia , Feminino , Masculino , Fatores de Tempo , Imagem Cinética por Ressonância Magnética , Frequência Cardíaca/efeitos dos fármacos
3.
Pacing Clin Electrophysiol ; 46(8): 939-941, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37461381

RESUMO

Over the last decades, cardiac electronic implantable devices (CEID) have incorporated a myriad of technological capabilities that are not conveniently inferred by using the conventional ICHD and NBG coding systems. We propose a new coding system (i.e., the C-ARL-A coding system) aimed at overcoming this important limitation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
4.
JACC Clin Electrophysiol ; 9(6): 765-775, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36752472

RESUMO

BACKGROUND: New tools are needed to improve ventricular tachycardia (VT) substrate characterization and optimize outcomes. LI provides biophysical tissue characterization. OBJECTIVES: The purpose of this study was to test local impedance (LI)-based mapping to predict critical ventricular tachycardia components after myocardial infarction (MI). METHODS: One month after a nonreperfused anterior MI, endo-epicardial high-density electroanatomic mapping and endocardial LI mapping were performed in 23 Landrace Large X White pigs. LI thresholds were set using the blood pool value to define a 10 Ω range: low (blood pool +9Ω). RESULTS: Low LI was detected in low-voltage areas in 100% of cases, but intermediate LI was found in both core (87%) and border zone (12.5%) voltage areas. A total of 17 VTs were induced (VT isthmus identified in 9 animals). VT inducibility was associated with the size of intermediate LI area (OR: 1.19 [95% CI: 1.0-1.4]; P = 0.039) and the presence of specific LI patterns: LI corridor (OR: 15.0 [95% CI: 1.3-169.9]; P = 0.029); LI gradient (OR: 30.0 [95% CI: 2.1-421.1]; P = 0.012), high LI heterogeneity (OR: 21.7 [95% CI: 1.8-260.6]; P = 0.015), and presence of ≥2 low LI regions (OR: 11.3 [95% CI: 1.0-130.2]; P = 0.053). Potential VT isthmuses were in areas of intermediate LI and colocalized to LI patterns associated with VT inducibility in all cases (LI corridors or LI gradient). Low LI regions did not actively participate in the VT circuit (0%). CONCLUSIONS: LI mapping is feasible and may add useful characterization of the VT substrate. Specific LI patterns (ie, corridors, gradients) were associated with VT inducibility and colocalized with the VT isthmus, thus representing a potential new target for ablation in substrate-based procedures.


Assuntos
Infarto do Miocárdio , Taquicardia Ventricular , Animais , Suínos , Impedância Elétrica , Infarto do Miocárdio/complicações , Mapeamento Epicárdico , Endocárdio
5.
Cardiol J ; 30(4): 534-542, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34708863

RESUMO

BACKGROUND: Freezing rate of second-generation cryoballoon (CB) is a biophysical parameter that could assist pulmonary vein isolation. The aim of this study is to assess freezing rate (time to reach -30°C ([TT-30C]) as an early predictor of acute pulmonary vein isolation using the CB. METHODS: Biophysical data from CB freeze applications within a multicenter, nation-wide CB ablation registry were gathered. Successful application (SA), was defined as achieving durable intraprocedural vein isolation. And SA with time to isolation under 60 s (SA-TTI<60) as achieving durable vein isolation in under 60 s. Logistic regressions were performed and predictive models were built for the data set. RESULTS: 12,488 CB applications from 1,733 atrial fibrillation (AF) ablation procedures were included within 27 centers from a Spanish CB AF ablation registry. SA was achieved in 6,349 of 9,178 (69.2%) total freeze applications, and SA-TTI<60 was obtained in 2,673 of 4,784 (55.9%) freezes where electrogram monitoring was present. TT-30C was shorter in the SA group (33.4 ± 9.2 vs 39.3 ± 12.1 s; p < 0.001) and SA-TTI<60 group (31.8 ± 7.6 vs. 38.5 ± 11.5 s; p < 0.001). Also, a 10 s increase in TT-30C was associated with a 41% reduction in the odds for an SA (odds ratio [OR] 0.59; 95% confidence interval [CI] 0.56-0.63) and a 57% reduction in the odds for achieving SA-TTI<60 (OR 0.43; 95% CI 0.39-0.49), when corrected for electrogram visualization, vein position, and application order. CONCLUSIONS: Time to reach -30°C is an early predictor of the quality of a CB application and can be used to guide the ablation procedure even in the absence of electrogram monitoring.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva
6.
J Interv Card Electrophysiol ; 66(3): 683-691, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36207558

RESUMO

BACKGROUND: Adequate synchronization between the passive ("E") and active ("a") left ventricular (LV) diastolic filling contributes to the efficiency of the heartbeat. E/a superposition in dual-chamber pacemaker (PM) recipients is an under-recognized phenomenon that may be corrected by shortening the atrio-ventricular interval (AVI). We aimed at establishing the prevalence of E/a superposition in PM patients and to analyze the clinical, echocardiographic, and biological impact of AVI shortening. METHODS: Seventy patients with dual-chamber PMs (74 ± 8 years old, 12 women) were consecutively enrolled in this study. Patients with baseline E/a superposition were crossed over from default to manually shortened AVI or vice versa in a case-control fashion (intervention group). Patients without baseline E/a superposition (controls) served as a reference for a descriptive comparison with the intervention group. RESULTS: Thirty-three patients had E/a superposition after PM implantation (47%). Controls (n = 37) had higher LV ejection fraction (59 ± 8% vs. 53 ± 10%, p = 0.048) and lower levels of high sensitive troponin T and ST2 (p < 0.05) than intervention group patients. The AVI was shortened at 48 ± 9 ms in order to ensure adequate E/a separation. The walked distance increased from 75 ± 17 to 78 ± 10% (p = 0.049) and the Euro-QoL score from 0.50 ± 0.27 to 0.63 ± 0.19 (p = 0.011) with short AVI. CONCLUSIONS: E/a superposition occurs in approximately half of dual-chamber PM recipients and is associated with reduced LV function and increased myocardial injury biomarkers. AVI shortening produces a modest but significant effect in functional capacity and quality of life.


Assuntos
Marca-Passo Artificial , Qualidade de Vida , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Diástole , Função Ventricular Esquerda
7.
Front Cardiovasc Med ; 9: 983001, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36204562

RESUMO

Objective: To assess the arrhythmic safety profile of the adipose graft transposition procedure (AGTP) and its electrophysiological effects on post-myocardial infarction (MI) scar. Background: Myocardial repair is a promising treatment for patients with MI. The AGTP is a cardiac reparative therapy that reduces infarct size and improves cardiac function. The impact of AGTP on arrhythmogenesis has not been addressed. Methods: MI was induced in 20 swine. Contrast-enhanced magnetic resonance (ce-MRI), electrophysiological study (EPS), and left-ventricular endocardial high-density mapping were performed 15 days post-MI. Animals were randomized 1:1 to AGTP or sham-surgery group and monitored with ECG-Holter. Repeat EPS, endocardial mapping, and ce-MRI were performed 30 days post-intervention. Myocardial SERCA2, Connexin-43 (Cx43), Ryanodine receptor-2 (RyR2), and cardiac troponin-I (cTnI) gene and protein expression were evaluated. Results: The AGTP group showed a significant reduction of the total infarct scar, border zone and dense scar mass by ce-MRI (p = 0.04), and a decreased total scar and border zone area in bipolar voltage mapping (p < 0.001). AGTP treatment significantly reduced the area of very-slow conduction velocity (<0.2 m/s) (p = 0.002), the number of deceleration zones (p = 0.029), and the area of fractionated electrograms (p = 0.005). No differences were detected in number of induced or spontaneous ventricular arrhythmias at EPS and Holter-monitoring. SERCA2, Cx43, and RyR2 gene expression were decreased in the infarct core of AGTP-treated animals (p = 0.021, p = 0.018, p = 0.051, respectively). Conclusion: AGTP is a safe reparative therapy in terms of arrhythmic risk and provides additional protective effect against adverse electrophysiological remodeling in ischemic heart disease.

8.
J Clin Med ; 11(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35268259

RESUMO

Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market Registry to compare characteristics and outcomes of patients undergoing CBA for PeAF versus PaAF. Results: A total of 944 patients (57.8 ± 10.4 years; 70.1% male) with AF (27.9% persistent) were prospectively included from 25 centers. PeAF patients were more likely to have structural heart disease (67.7 vs. 11.4%; p < 0.001) and left atrium dilation (72.6 vs. 43.3%; p < 0.001). CBA of PeAF was less likely to be performed under general anesthesia (10.7 vs. 22.2%; p < 0.001), with an arterial line (32.2 vs. 44.6%; p < 0.001) and assisted transeptal puncture (11.9 vs. 17.9%; p = 0.025). During an application, PeAF patients had a longer time to −30 °C (35.91 ± 14.20 vs. 34.93 ± 12.87 s; p = 0.021) and a colder balloon nadir temperature during vein isolation (−35.04 ± 9.58 vs. −33.61 ± 10.32 °C; p = 0.004), but received fewer bonus freeze applications (30.7 vs. 41.1%; p < 0.001). There were no differences in acute pulmonary vein isolation and procedure-related complications. Overall, 76.7% of patients were free from AF recurrences at 15-month follow-up (78.9% in PaAF vs. 70.9% in PeAF; p = 0.09). Conclusions: Patients with PeAF have a more diseased substrate, and CBA procedures performed in such patients were more simplified, although longer/colder freeze applications were often applied. The acute efficacy/safety profile of CBA was similar between PaAF and PeAF patients, but long-term results were better in PaAF patients.

9.
Sci Rep ; 12(1): 298, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996973

RESUMO

Inappropriate sinus tachycardia (IST) is a common observation in patients with post-COVID-19 syndrome (PCS) but has not yet been fully described to date. To investigate the prevalence and the mechanisms underlying IST in a prospective population of PCS patients. Consecutive patients admitted to the PCS Unit between June and December 2020 with a resting sinus rhythm rate ≥ 100 bpm were prospectively enrolled in this study and further examined by an orthostatic test, 2D echocardiography, 24-h ECG monitoring (heart rate variability was a surrogate for cardiac autonomic activity), quality-of-life and exercise capacity testing, and blood sampling. To assess cardiac autonomic function, a 2:1:1 comparative sub-analysis was conducted against both fully recovered patients with previous SARS-CoV-2 infection and individuals without prior SARS-CoV-2 infection. Among 200 PCS patients, 40 (20%) fulfilled the diagnostic criteria for IST (average age of 40.1 ± 10 years, 85% women, 83% mild COVID-19). No underlying structural heart disease, pro-inflammatory state, myocyte injury, or hypoxia were identified. IST was accompanied by a decrease in most heart rate variability parameters, especially those related to cardiovagal tone: pNN50 (cases 3.2 ± 3 vs. recovered 10.5 ± 8 vs. non-infected 17.3 ± 10; p < 0.001) and HF band (246 ± 179 vs. 463 ± 295 vs. 1048 ± 570, respectively; p < 0.001). IST is prevalent condition among PCS patients. Cardiac autonomic nervous system imbalance with decreased parasympathetic activity may explain this phenomenon.


Assuntos
COVID-19/complicações , Taquicardia Sinusal/etiologia , Adulto , COVID-19/diagnóstico , COVID-19/patologia , COVID-19/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Prevalência , Estudos Prospectivos , SARS-CoV-2/isolamento & purificação , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/patologia , Taquicardia Sinusal/fisiopatologia , Síndrome de COVID-19 Pós-Aguda
10.
Heart Rhythm O2 ; 3(6Part A): 656-664, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589911

RESUMO

Background: Atrial fibrillation (AF) ablation strategy is associated with a non-negligible risk of complications and often requires repeat procedures (AF ablation track), implying repetitive exposure to procedural risk. Objective: The purpose of this study was to develop and validate a model to estimate individualized cumulative risk of complications in patients undergoing the AF ablation track (Atrial Fibrillation TRAck Complication risK [AF-TRACK] calculator). Methods: The model was derived from a multicenter cohort including 3762 AF ablation procedures in 2943 patients. A first regression model was fitted to predict the propensity for repeat ablation. The AF-TRACK calculator computed the risk of AF ablation track complications, considering the propensity for repeat ablation. Internal (cross-validation) and external (independent cohort) validation were assessed for discrimination capacity (area under the curve [AUC]) and goodness of fit (Hosmer-Lemeshow [HL] test). Results: Complications (N = 111) occurred in 3.7% of patients (2.9% of procedures). Predictors included female sex, heart failure, sleep apnea syndrome, and repeat procedures. The model showed fair discrimination capacity to predict complications (AUC 0.61 [0.55-0.67]) and likelihood of repeat procedure (AUC 0.62 [0.60-0.64]), with good calibration (HL χ2 12.5; P = .13). The model maintained adequate discrimination capacity (AUC 0.67 [0.57-0.77]) and calibration (HL χ2 5.6; P = .23) in the external validation cohort. The validated model was used to create the Web-based AF-TRACK calculator. Conclusion: The proposed risk model provides individualized estimates of the cumulative risk of complications of undergoing the AF ablation track. The AF-TRACK calculator is a validated, easy-to-use, Web-based clinical tool to calibrate the risk-to-benefit ratio of this treatment strategy.

11.
J Interv Card Electrophysiol ; 63(3): 591-599, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34595692

RESUMO

BACKGROUND: Catheter ablation of accessory pathways (AP) with bidirectional conduction may be challenging due to issues related to anatomical course or location. OBJECTIVE: We describe an alternative electro-anatomical mapping technique which aims at depicting the entire anatomic course of the AP from the atrial toward the ventricular insertion in order to guide catheter ablation. METHODS: Twenty consecutive patients with confirmed bidirectional AP conduction and at least one previous ablation procedure or para-Hisian location were included. 3-D electro-anatomical mapping was used to depict the merged 10-ms isochrone area of maximum early activation of both the ventricular and atrial signals during sinus rhythm and ventricular pacing/orthodromic tachycardia, respectively. Catheter ablation was performed within the depicted earliest isochrone area. RESULTS: Acute bidirectional AP conduction block was achieved in all patients 4.2 ± 1.7 s after the first radiofrequency energy pulse was delivered, without reconnection during a 30 ± 10 min post-ablation observation time. No procedural complications were seen. After a mean follow-up period of 9 ± 7 months (range 3 to 16), no recurrences were documented. CONCLUSION: This merged two-way mapping technique is a safe, efficient, and effective technique for ablation of APs with bidirectional conduction.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Frequência Cardíaca , Humanos
12.
Lupus ; 30(10): 1596-1602, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34192953

RESUMO

OBJECTIVES: Recent data suggest that some adult patients with autoimmune rheumatic diseases may develop cardiac conduction and repolarization abnormalities mediated by anti-Ro/SSA antibodies. We aim to investigate the utility of a cardiac screening in patients with systemic lupus erythematous (SLE) and anti-Ro/SSA positivity. METHODS: SLE patients who consecutively attended a Rheumatology clinic during 1 year where evaluated for the presence and levels of anti-Ro/SSA antibodies, and clinical and biological markers of organ damage and disease activity. All participants underwent a cardiovascular anamnesis and physical examination, ECG, echocardiography, and 24-hour Holter. RESULTS: Of the 145 recruited patients, 49 (32%) had anti-Ro/SSA positivity. None had any degree of atrioventricular block in the ECG or Holter monitoring. No significant differences were observed between anti-Ro/SSA-positive vs. negative patients in terms of PR, QRS or QTc intervals. No clinically significant arrhythmias were recorded during Holter monitoring and no differences in average heart rate, heart rate variability, or atrial or ventricular ectopy burden were observed. Finally, no differences were found in echocardiographic measurements. CONCLUSIONS: In this study of SLE patients, anti-Ro/SSA positivity was not associated with significant alterations in ECG, echocardiography, or 24-hour Holter. These findings do not support ordinary cardiac evaluation in these patients. (Clinicaltrials.gov registration number: NCT02162992).


Assuntos
Bloqueio Atrioventricular , Lúpus Eritematoso Sistêmico , Adulto , Anticorpos Antinucleares/sangue , Anticorpos Antinucleares/imunologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Eletrocardiografia Ambulatorial , Frequência Cardíaca/fisiologia , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/diagnóstico
13.
JACC Case Rep ; 3(1): 150-155, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34317491

RESUMO

Up to one-third of patients who undergo cardiac resynchronization therapy do not obtain clinical benefit. A systematic approach can identify treatable causes in many nonresponding patients. We present a case of nonresponse to cardiac resynchronization therapy that resolved by ablation of the atrioventricular node in a patient with complete atrioventricular block. (Level of Difficulty: Advanced.).

14.
Am J Cardiol ; 138: 46-52, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33058803

RESUMO

Obstructive sleep apnea-hypopnea syndrome (OSA) compromises the efficacy of atrial fibrillation (AF) control strategies. Continuous positive airway pressure (CPAP) may ameliorate arrhythmia control especially in early AF stages (new-onset AF). We investigated a practical screening strategy to determine the likelihood of CPAP indication in new-onset AF patients. Seventy-seven consecutive patients with new-onset (<1 month) AF were prospectively evaluated. Of them, 4 were excluded due to previously diagnosed OSA. The remaining 73 (68% persistent AF) fulfilled the Epworth, Berlin and STOP-BANG questionnaires, an ambulatory polysomnography being performed thereafter in all them in order to determine the apnea-hipopnea index (AHI). CPAP was indicated following conventional criteria. The variables associated with the diagnosis of OSA, with the AHI value and with CPAP indication were investigated by means of descriptive, univariate and multivariate analysis. The prevalence of OSA of any degree and CPAP indication was 82% and 37%, respectively. The variables associated (p < 0.05) with a higher AHI were male gender, body mass index, obesity, hypertension, and high-risk scoring at the Berlin and STOP-BANG questionnaires. In the multivariate analysis, the STOP-BANG scoring proved superior to conventional risk factors and became the only variable predicting CPAP indication (odds ratio 4.5 [1.9 to 10.6]; p = 0.01), an optimized cutoff value of ≥4 being newly established (sensitivity/specificity 76/65%). In conclusion, in patients referred with new-onset AF we documented a high risk of OSA and of need for CPAP. A STOP-BANG scoring of ≥4 in our population was a practical screening alternative to direct polysomnography in this setting.


Assuntos
Fibrilação Atrial/terapia , Apneia Obstrutiva do Sono/diagnóstico , Doenças não Diagnosticadas/diagnóstico , Idoso , Fibrilação Atrial/epidemiologia , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Obesidade/epidemiologia , Razão de Chances , Polissonografia , Prevalência , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fatores Sexuais , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/terapia , Inquéritos e Questionários , Doenças não Diagnosticadas/epidemiologia
15.
JACC Clin Electrophysiol ; 6(11): 1435-1448, 2020 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-33121673

RESUMO

OBJECTIVES: This study sought to analyze safety and outcomes of ventricular tachycardia (VT) substrate ablation during sinus rhythm (SR), without baseline VT induction. BACKGROUND: Safety and outcomes after scar-related VT ablation during SR are not well known. Hemodynamic instability and need for electrical cardioversion can compromise safety of VT ablation procedures. METHODS: Four hundred twelve consecutive patients with structural heart disease undergoing VT ablation were included in a prospective multicenter registry. Substrate ablation during SR, without baseline VT induction, was the first step of the ablation procedure and the standard protocol. Scar dechanneling was the substrate ablation technique used. VT inducibility was tested after substrate ablation. RESULTS: VT induction protocol was negative after substrate ablation in 289 patients (70.1%), completing the procedure in SR. Procedure-related complication rate was 6.5%, including 1 death (0.2%). Thirty-day mortality after first VT ablation procedure was 1.7%. Overall survival was 95.8% and 88.6% at 1 and 3 years of follow-up, respectively. In a multivariable proportional hazards regression model, age ≥70 years (hazard ratio [HR]: 4.95 [2.59 to 9.47]; p < 0.001), chronic obstructive pulmonary disease (HR: 2.37 [1.24 to 4.52]; p = 0.008), left ventricular ejection fraction <30% (HR: 2.43 [1.37 to 4.33]; p = 0.002), and incomplete substrate ablation (HR: 2.37 [1.24 to 4.52]; p = 0.026) were independent predictors of overall mortality. At 12 months' follow-up, VT-free survival was 82.5% after 1 procedure and 87.8% after n procedures CONCLUSIONS: Substrate ablation during SR avoiding multiple VT induction has low procedure-related complications and low early mortality. Age, chronic obstructive pulmonary disease, and reduced left ventricular ejection fraction, but also incomplete substrate elimination, are predictors of mortality.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Sistema de Registros , Volume Sistólico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
16.
Circ Arrhythm Electrophysiol ; 13(11): e008707, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33031713

RESUMO

BACKGROUND: Myocardial fibrosis is key for atrial fibrillation maintenance. We aimed to test the efficacy of ablating cardiac magnetic resonance (CMR)-detected atrial fibrosis plus pulmonary vein isolation (PVI). METHODS: This was an open-label, parallel-group, randomized, controlled trial. Patients with symptomatic drug-refractory atrial fibrillation (paroxysmal and persistent) undergoing first or repeat ablation were randomized in a 1:1 basis to receive PVI plus CMR-guided fibrosis ablation (CMR group) or PVI alone (PVI-alone group). The primary end point was the rate of recurrence (>30 seconds) at 12 months of follow-up using a 12-lead ECG and Holter monitoring at 3, 6, and 12 months. The analysis was conducted by intention-to-treat. RESULTS: In total, 155 patients (71% male, age 59±10, CHA2DS2-VASc 1.3±1.1, 54% paroxysmal atrial fibrillation) were allocated to the PVI-alone group (N=76) or CMR group (N=79). First ablation was performed in 80% and 71% of patients in the PVI-alone and CMR groups, respectively. The mean atrial fibrosis burden was 12% (only ≈50% of patients had fibrosis outside the pulmonary vein area). One hundred percent and 99% of patients received the assigned intervention in the PVI-alone and CMR group, respectively. The primary outcome was achieved in 21 patients (27.6%) in the PVI-alone group and 22 patients (27.8%) in the CMR group (odds ratio: 1.01 [95% CI, 0.50-2.04]; P=0.976). There were no differences in the rate of adverse events (3 in the CMR group and 2 in the PVI-alone group; P=0.68). CONCLUSIONS: A pragmatic ablation approach targeting CMR-detected atrial fibrosis plus PVI was not more effective than PVI alone in an unselected population undergoing atrial fibrillation ablation with low fibrosis burden. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02698631.


Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter , Átrios do Coração/cirurgia , Imageamento por Ressonância Magnética , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Espanha , Fatores de Tempo , Resultado do Tratamento
17.
Europace ; 22(9): 1391-1400, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32898254

RESUMO

AIMS: Sudden cardiac death (SCD) risk estimation in patients referred for cardiac resynchronization therapy (CRT) remains a challenge. By CRT-mediated improvement of left ventricular ejection fraction (LVEF), many patients loose indication for primary prevention implantable cardioverter-defibrillator (ICD). Increasing evidence shows the importance of myocardial scar for risk prediction. The aim of this study was to investigate the prognostic impact of myocardial scar depending on the echocardiographic response in patients undergoing CRT. METHODS AND RESULTS: Patients with indication for CRT were prospectively enrolled. Decision about ICD or pacemaker implantation was based on clinical criteria. All patients underwent delayed-enhancement cardiac magnetic resonance imaging. Median follow-up duration was 45 (24-75) months. Primary outcome was a composite of sustained ventricular arrhythmia, appropriate ICD therapy, or SCD. A total of 218 patients with LVEF 25.5 ± 6.6% were analysed [158 (73%) male, 64.9 ± 10.7 years]. Myocardial scar was observed in 73 patients with ischaemic cardiomyopathy (ICM) (95% of ICM patients); in 62 with non-ischaemic cardiomyopathy (45% of these patients); and in all but 1 of 36 (17%) patients who reached the primary outcome. Myocardial scar was the only significant predictor of primary outcome [odds ratio 27.7 (3.8-202.7)], independent of echocardiographic CRT response. A total of 55 (25%) patients died from any cause or received heart transplant. For overall survival, only a combination of the absence of myocardial scar with CRT response was associated with favourable outcome. CONCLUSION: Malignant arrhythmic events and SCD depend on the presence of myocardial scar but not on CRT response. All-cause mortality improved only with the combined absence of myocardial scar and CRT response.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/terapia , Humanos , Masculino , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
19.
J Cardiovasc Electrophysiol ; 30(9): 1483-1490, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31115940

RESUMO

INTRODUCTION: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort. METHODS: This was a multicenter study including consecutive patients undergoing first paroxysmal and persistent AF ablation with radiofrequency or cryoballoon catheters during 2013. Cox proportional hazard regression models were performed to identify predictors of recurrence. RESULTS: In total, 309 patients were included across nine centers (71% men, 57 ± 10 years old, 46% with hypertension, and 66% with CHA2 DS2 -VASc ≤ 1). Most patients had paroxysmal AF (67%) and underwent radiofrequency ablation (68%) with a median DAT of 51 (43) months. Patients with DAT ≤ 1 year (16.6%) were less likely to have repeat procedures (4% vs 18%; P = .017). The adjusted proportional hazards Cox model identified hypertension (P = .005), heart failure (P = .011), nonparoxysmal AF (P = .038), DAT > 1 year (P = .007), and LA diameter (P = .026) as independent predictors for AF recurrence. DAT > 1 year was the only modifiable factor independently associated with recurrence (HR 4.2 [95% CI, 1.5-11.9]) CONCLUSION: Diagnosis-to-ablation time is a modifiable factor independently associated with recurrent arrhythmia and repeat ablation after first AF ablation. An early intervention strategy during the first year from AF diagnosis might improve outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Tempo para o Tratamento , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
20.
Ann Noninvasive Electrocardiol ; 24(6): e12662, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31141244

RESUMO

A 52-year-old man was admitted due to out-hospital cardiac arrest. Recurrent ventricular fibrillation (VF) occurred under therapeutic hypothermia thereafter. Previously inadverted full pre-excitation was documented exclusively and immediately prior to 4 out of the 5 VF relapses. Coronary vasospasm and early repolarization were also documented. An electrophysiological study demonstrated poor anterograde conduction over a left-sided accessory pathway. We theorize that maximum pre-excitation favored in-hospital VF by augmenting the repolarization vulnerability induced by therapeutic hypothermia, with coronary vasospasm accounting as the probable cause of out-hospital VF. A plausible VF mechanism in WPW syndrome unrelated to pre-excited atrial fibrillation is discussed.


Assuntos
Fibrilação Atrial , Eletrocardiografia/métodos , Fibrilação Ventricular/fisiopatologia , Síndrome de Wolff-Parkinson-White/complicações , Síndrome de Wolff-Parkinson-White/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA