Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
2.
J Clin Med ; 13(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38892978

RESUMO

Objectives: The optimal surgical approach for the treatment of functional mitral regurgitation (FMR) remains controversial. Current guidelines suggest that the surgical approach has to be tailored to the individual patient. The aim of the present study was to clarify further aspects of this tailored treatment. Methods: From 01/2006 to 12/2015, 390 patients underwent mitral valve (MV) surgery for FMR (ischemic n = 241, non-ischemic n = 149) at our institution. A regression analysis was used to determine the effect of MV repair or replacement on survival. The patients were analyzed according to the etiology of the MR (ischemic or non-ischemic), different age groups (<65 years, 65-75 years, and >75 years), LV function, and LV dimensions, as well as the underlying heart rhythm. Results: The overall survival rates for the repair group at 1, 5, and 8 years were 86.1 ± 1.9%, 70.6 ± 2.6%, and 55.1 ± 3.1%, respectively. For the same intervals, the survival rates in patients who underwent MV replacement were 75.9 ± 4.5%, 58.6 ± 5.4%, and 40.9 ± 6.4%, respectively (p = 0.003). Patients younger than 65 years, with an ischemic etiology of FMR, poor ejection fraction (<30%), severe dilatation of left ventricle (LVEDD > 60mm), and presence of atrial fibrillation had significantly higher mortality rates after MV replacement (HR, 3.0; CI, 1.3-6.9; p = 0.007). Patients between 65 and 75 years of age had a higher risk of death when undergoing mitral valve replacement (HR, 1.7; CI, 1.0-2.8; p = 0.04). In patients older than 75 years, the surgical approach (MV repair or replacement) had no effect on postoperative survival (HR, 0.8; CI, 0.4-1.3; p = 0.003). Conclusions: Our data demonstrate that, in patients younger than 65 years, the treatment of choice for FMR should be MV repair. This advantage was even more evident in patients with an ischemic origin of MR, a poor ejection fraction, a severe LV dilatation, and atrial fibrillation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38709456

RESUMO

Intraoperative antithrombotic drug removal by haemoadsorption is a novel strategy to reduce perioperative bleeding in patients on antithrombotic drugs undergoing cardiac surgery. The international STAR registry reports real-world clinical outcomes associated with this application. All patients underwent cardiac surgery before completing the recommended washout period. The haemoadsorption device was incorporated into the cardiopulmonary bypass (CPB) circuit. Patients on P2Y12 inhibitors comprised group 1, and patients on direct-acting oral anticoagulants (DOAC) group 2. Outcome measurements included bleeding events according to standardised definitions and 24-hour chest-tube-drainage (CTD). 165 patients were included from 8 institutions in Austria, Germany, Sweden, and the UK. Group 1 included 114 patients (62.9 ± 11.6years, 81% male) operated at a mean time of 33.2 h from the last P2Y12 inhibitor dose with a mean CPB duration of 117.1 ± 62.0 min. Group 2 included 51 patients (68.4 ± 9.4years, 53% male), operated at a mean time of 44.6 h after the last DOAC dose, with a CPB duration of 128.6 ± 48.4 min. In Group 1, 15 patients experienced a BARC-4 bleeding event (13%), including 3 reoperations (2.6%). The mean 24-hour CTD was 651 ± 407mL. In Group 2, 8 patients experienced a BARC-4 bleeding event (16%) including 4 reoperations (7.8%). The mean CTD was 675 ± 363mL. This initial report of the ongoing STAR registry shows that the intraoperative use of a haemoadsorption device is simple and safe, and may potentially mitigate the expected high bleeding risk of patients on antithrombotic drugs undergoing cardiac surgery before completion of the recommended washout period.Clinical registration number: ClinicalTrials.gov identifier: NCT05077124.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38083688

RESUMO

Acute kidney failure is a dangerous complication for ICU patients, and it is difficult to identify at early stage with conventional medical analysis. In recent years, machine learning approaches have been applied to tackle medical diagnosis tasks with great performance. In this work, we deploy machine learning models for early detection of acute kidney failure that can handle static, temporal, sparse and dense data of ICU patients. We investigate different pre-processing methods for patient data to achieve higher prediction performance and how they influence the contribution of different physiological signals in the prediction process.


Assuntos
Injúria Renal Aguda , Unidades de Terapia Intensiva , Humanos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Aprendizado de Máquina , Diagnóstico Precoce
6.
Artigo em Inglês | MEDLINE | ID: mdl-38083790

RESUMO

We propose a novel framework to estimate intensive care unit patients' health risk continuously with anomaly-encoded patient data. This framework consists of two modules. In the first module, we use Gaussian process models to learn change trend and day-night circulation in temporal patient data and annotate abnormal data. Such models provide dynamically adaptable bedside patient monitoring instead of conventional threshold-based monitoring. In the second module, we use the abnormal data together with the learned Gaussian models to estimate patients' risk level by predicting their in-hospital mortality and remaining length of stay in ICU ward. We show that prediction models with anomaly-encoded data have better performance than those with raw patient measurements, and they are comparable with state-of-art prediction models.


Assuntos
Cuidados Críticos , Unidades de Terapia Intensiva , Humanos , Mortalidade Hospitalar , Hospitais
7.
Front Cardiovasc Med ; 10: 1252163, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727303

RESUMO

Background: Data comparing new-generation self-expandable (SEV, Evolut R/PRO) vs. balloon-expandable (BEV, SAPIEN 3/3Ultra) transcatheter heart valve replacement (TAVR) in bicuspid aortic valve stenosis (BAV) is limited. Our aim was to compare 30-day results of SEV and BEV implantations in patients with BAV. Methods: A total of 2009 patients underwent TAVR between April 2015 and June 2021 at our Centre. From our institutional registry, we identified 106 consecutive patients with BAV who underwent TAVR using SEV and BEV. Results: A 106 patients (n = 68 BEV; n = 38 SEV) were included. Mean age was 74.6 ± 8.8 years (BEV) vs.75.3 ± 8.7 years (SEV) (p = 0.670) and Society of Thoracic Surgeons score was 2.6 ± 1.9 (BEV) vs. 2.6 ± 1.6 (SEV) (p = 0.374), respectively. Device landing zone calcium volume (DLZ-CV) was 1168 ± 811 vs. 945 ± 850 mm3 (p = 0.192). Valve Academic Research Consortium (VARC)-3 device success at 30 days was similar (BEV 80.9% vs. SEV 86.8%; p = 0.433). More post-dilatations were performed in SEVs (23.5% BEV vs. 52.6% SEV; p = 0.002). Overall mean gradient at 30 days follow-up was 11.9 ± 4.6 mmHG (BEV) vs. 9.2 ± 3.0 mmHG (SEV) (p = 0.002). A mild-moderate degree of paravalvular leak (PVL) was detected more often in the SEV group (7.4% vs. 13.2%; p = 0.305). A trend towards higher rate of permanent pacemaker implantation was observed in SEV (11.8% vs. 23.7%; p = 0.109). Conclusions: Treatment of BAV revealed similar performance using BEV and SEV. In this retrospective cohort study, hemodynamics were more favorable with the SEV, although there was a trend toward more PVL and significantly more post-dilations.

8.
Heart ; 109(18): 1394-1400, 2023 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-37376817

RESUMO

OBJECTIVE: Ventricular secondary mitral regurgitation (SMR) (Carpentier type IIIb) results from left ventricular (LV) remodelling, displacement of papillary muscles and tethering of mitral leaflets. The most appropriate treatment approach remains controversial. We aimed to assess the safety and efficacy of standardised relocation of both papillary muscles (subannular repair) at 1-year follow-up (FU). METHODS: REFORM-MR (Reform-Mitral Regurgitation) is a prospective, multicentre registry that enrolled consecutive patients with ventricular SMR (Carpentier type IIIb) undergoing standardised subannular mitral valve (MV) repair in combination with annuloplasty at five sites in Germany. Here, we report survival, freedom from recurrence of MR >2+, freedom from major adverse cardiac and cerebrovascular events (MACCEs), including cardiovascular death, myocardial infarction, stroke, MV reintervention and echocardiographic parameters of residual leaflet tethering at 1-year FU. RESULTS: A total of 94 patients (69.1% male) with a mean age of 65.1±9.7 years met the inclusion criteria. Advanced LV dysfunction (mean left ventricular ejection fraction 36.4±10.5%) and severe LV dilatation (mean left ventricular end-diastolic diameter 61.0±9.3 mm) resulted in severe mitral leaflet tethering (mean tenting height 10.6±3.0 mm) and an elevated mean EURO Score II of 4.8±4.6 prior to surgery. Subannular repair was successfully performed in all patients, without operative mortality or complications. One-year survival was 95.5%. At 12 months, a durable reduction of mitral leaflet tethering resulted in a low rate (4.2%) of recurrent MR >2+. In addition to a significant improvement in New York Heart Association (NYHA) class (22.4% patients in NYHA III/IV vs 64.5% patients at baseline, p<0.001), freedom from MACCE was observed in 91.1% of patients. CONCLUSIONS: Our study demonstrates the safety and feasibility of standardised subannular repair to treat ventricular SMR (Carpentier type IIIb) in a multicentre setting. By addressing mitral leaflet tethering, papillary muscle relocation results in very satisfactory 1-year outcomes and has the potential to durably restore MV geometry; nevertheless, long-term FU is mandatory. TRIAL REGISTRATION NUMBER: NCT03470155.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Volume Sistólico , Sístole , Resultado do Tratamento , Função Ventricular Esquerda
9.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225288

RESUMO

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Assuntos
Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Sistema de Registros
10.
JACC Cardiovasc Interv ; 16(8): 927-941, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37100556

RESUMO

BACKGROUND: Valve reintervention after transcatheter aortic valve replacement (TAVR) failure has not been studied in detail. OBJECTIVES: The authors sought to determine outcomes of TAVR surgical explantation (TAVR-explant) vs redo-TAVR because they are largely unknown. METHODS: From May 2009 to February 2022, 396 patients in the international EXPLANTORREDO-TAVR registry underwent TAVR-explant (181, 46.4%) or redo-TAVR (215, 54.3%) for transcatheter heart valve (THV) failure during a separate admission from the initial TAVR. Outcomes were reported at 30 days and 1 year. RESULTS: The incidence of reintervention after THV failure was 0.59% with increasing volume during the study period. Median time from index-TAVR to reintervention was shorter in TAVR-explant vs redo-TAVR (17.6 months [IQR: 5.0-40.7 months] vs 45.7 months [IQR: 10.6-75.6 months]; P < 0.001], respectively. TAVR-explant had more prosthesis-patient mismatch (17.1% vs 0.5%; P < 0.001) as the indication for reintervention, whereas redo-TAVR had more structural valve degeneration (63.7% vs 51.9%; P = 0.023), with a similar incidence of ≥moderate paravalvular leak between groups (28.7% vs 32.8% in redo-TAVR; P = 0.44). There was a similar proportion of balloon-expandable THV failures (39.8% TAVR-explant vs 40.5% redo-TAVR; P = 0.92). Median follow-up was 11.3 (IQR: 1.6-27.1 months) after reintervention. Compared with redo-TAVR, TAVR-explant had higher mortality at 30 days (13.6% vs 3.4%; P < 0.001) and 1 year (32.4% vs 15.4%; P = 0.001), with similar stroke rates between groups. On landmark analysis, mortality was similar between groups after 30 days (P = 0.91). CONCLUSIONS: In this first report of the EXPLANTORREDO-TAVR global registry, TAVR-explant had a shorter median time to reintervention, with less structural valve degeneration, more prosthesis-patient mismatch, and similar paravalvular leak rates compared with redo-TAVR. TAVR-explant had higher mortality at 30 days and 1 year, but similar rates on landmark analysis after 30 days.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Sistema de Registros , Desenho de Prótese
11.
Mamm Genome ; 34(2): 285-297, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36867212

RESUMO

Systemic-to-pulmonary shunt malfunction contributes to morbidity in children with complex congenital heart disease after palliative procedure. Neointimal hyperplasia might play a role in the pathogenesis increasing risk for shunt obstruction. The aim was to evaluate the role of epidermal growth factor receptor (EGFR) and matrix-metalloproteinase 9 (MMP-9) in the formation of neointimal within shunts. Immunohistochemistry was performed with anti-EGFR and anti-MMP-9 on shunts removed at follow-up palliative or corrective procedure. Whole-genome single-nucleotide polymorphisms genotyping was performed on DNA extracted from patients´ blood samples and allele frequencies were compared between the group of patients with shunts displaying severe stenosis (≥ 40% of lumen) and the remaining group. Immunohistochemistry detected EGFR and MMP-9 in 24 of 31 shunts, located mainly in the luminal area. Cross-sectional area of EGFR and MMP-9 measured in median 0.19 mm2 (IQR 0.1-0.3 mm2) and 0.04 mm2 (IQR 0.03-0.09 mm2), respectively, and correlated positively with the area of neointimal measured on histology (r = 0.729, p < 0.001 and r = 0.0479, p = 0.018, respectively). There was a trend of inverse correlation between the dose of acetylsalicylic acid and the degree of EGFR, but not MMP-9, expression within neointima. Certain alleles in epidermal growth factor (EGF) and tissue inhibitor of metalloproteinases 1 (TIMP-1) were associated with increased stenosis and neointimal hyperplasia within shunts. EGFR and MMP-9 contribute to neointimal proliferation in SP shunts of children with complex cyanotic heart disease. SP shunts from patients carrying certain risk alleles in the genes encoding for EGF and TIMP-1 displayed increased neointima.


Assuntos
Cardiopatias , Neointima , Humanos , Criança , Neointima/patologia , Inibidor Tecidual de Metaloproteinase-1/genética , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Hiperplasia/genética , Fator de Crescimento Epidérmico , Constrição Patológica , Receptores ErbB/genética
12.
J Thorac Cardiovasc Surg ; 166(5): 1418-1430.e4, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35525801

RESUMO

OBJECTIVE: We sought to determine outcomes of aortic valve replacement (AVR) versus root replacement after transcatheter AVR (TAVR) explantation because they remain unknown. METHODS: From November 2009 to September 2020, data from the EXPLANT-TAVR International Registry of patients who underwent TAVR explant were retrospectively reviewed, divided by AVR versus root replacement. After excluding explants performed during the same admission as the initial TAVR and concomitant procedures involving the other valves, 168 AVR cases were compared with 28 root replacements, and outcomes were reported at 30 days and 1 year. RESULTS: Among 196 patients (mean age, 73.5 ± 9.9 years) who had primary aortic valve intervention at TAVR explant, the median time from TAVR to surgical explant was 11.2 months (interquartile range, 4.4-32.9 months). Indications for explant were similar between the 2 groups. Compared with AVR, patients requiring root replacement had fewer comorbidities but more unfavorable anatomy for redo TAVR (52.6% vs 26.4%; P = .032), fewer urgent/emergency cases (32.1% vs 58.3%; P = .013), longer median interval from index TAVR to TAVR explant (17.6 vs 9.9 months; P = .047), and more concomitant ascending aortic replacement (58.8% vs 14.0%; P < .001). Median follow-up was 6.9 months (interquartile range, 1.4-21.6 months) after TAVR explant and 97.4% complete. Overall survival at follow-up was 81.2% with no differences between groups (log rank P = .54). In-hospital, 30-day, and 1-year mortality rates and stroke rates were not different between the 2 groups. CONCLUSIONS: In the EXPLANT-TAVR Registry, AVR and root replacement groups had different clinical characteristics, but no differences in short-term mortality and morbidities. Further investigations are necessary to identify patients at risk of root replacement in TAVR explant.

13.
Ann Thorac Surg ; 115(1): 96-103, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35690138

RESUMO

BACKGROUND: The long-term outcomes of mitral valve repair by nonresection techniques, such as annuloplasty and chordal replacement, for degenerative mitral valve regurgitation were investigated. METHODS: All consecutive patients with degenerative mitral regurgitation who received solely chordal replacement and annuloplasty for mitral valve repair between 2003 and 2010 at the German Heart Center Munich were reviewed. The endpoints of this retrospective study were survival, cumulative incidence of reoperation on the mitral valve, and cumulative incidence of significant recurrent mitral regurgitation. RESULTS: A total of 346 patients were evaluated. The median follow-up period was 10.86 (range, 0.01-15.86) years. The 30-day mortality rate was 0.58% (n = 2 of 346), whereas the 5-year survival was 92.97% ± 1.41%. At 5 years, cumulative incidence of recurrent mitral regurgitation was 6.87% ± 1.57% and cumulative incidence of reoperation on the mitral valve was 3.69% ± 1.05%. Survival at 10 years was 83.35% ± 2.15%. At 10 years, cumulative incidence of recurrent mitral regurgitation was 13.31% ± 2.22% and cumulative incidence of reoperation was 7.84% ± 1.55%. Cox regression analysis identified age, diabetes mellitus, and reduced left ventricular ejection fraction <55% as independent risk factors for death. Left ventricular ejection fraction <55% was revealed as independent risk factor for significant recurrent mitral regurgitation. CONCLUSIONS: This study demonstrated excellent long-term outcomes with low incidence of reoperation after mitral valve repair using chordal replacement in a highly selected patient cohort. Our findings emphasized the importance of early intervention in severe degenerative mitral regurgitation, especially in patients with reduced left ventricular ejection fraction.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Volume Sistólico , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Reoperação , Anuloplastia da Valva Mitral/métodos , Seguimentos
14.
Artigo em Inglês | MEDLINE | ID: mdl-36462752

RESUMO

BACKGROUND: We aimed to compare hemodynamic performance of the Avalus (Medtronic) and the Perimount Magna Ease (PME, Edwards Lifesciences) bioprosthesis up to 5 years by serial echocardiographic examinations. METHODS: In patients undergoing aortic valve replacement, 58 received PME prostheses between October 2007 and October 2008, and another 60 received Avalus prostheses between October 2014 and November 2015. To ensure similar baseline characteristics, we performed a propensity score matching based on left ventricular ejection fraction, age, body surface area, and aortic annulus diameter measured by intraoperative transesophageal echocardiography. Thereafter, 48 patients remained in each group. Mean age at operation was 67 ± 6 years and mean EuroSCORE-II was 1.7 ± 1.1. Both values did not differ significantly between the two groups. RESULTS: At 1 year the mean pressure gradient (MPG) was 15.4 ± 4.3 mm Hg in the PME group and 14.7 ± 5.1 mm Hg in the Avalus group (p = 0.32). The effective orifice area (EOA) was 1.65 ± 0.45 cm2 in the PME group and 1.62 ± 0.45 cm2 in the Avalus group (p = 0.79). At 5 years the MPG was 16.6 ± 5.1 mm Hg in the PME group and 14.7 ± 7.1 mm Hg in the Avalus group (p = 0.20). The EOA was 1.60 ± 0.49 cm2 in the PME group and 1.51 ± 0.40 cm2 in the Avalus group (p = 0.38). Five-year survival was 88% in the PME group and 91% in the Avalus group (p = 0.5). In the PME group, there were no reoperations on the aortic valve, whereas in the Avalus group three patients required a reoperation due to endocarditis. CONCLUSION: Both bioprostheses exhibit similar hemodynamic performance during a 5-year follow-up.

15.
J Cardiothorac Surg ; 17(1): 343, 2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36581901

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) is one of the most common heart valve diseases that is a sequel of left ventricular remodelling. Although mitral valve annuloplasty is a standard treatment of FMR, the recurrence of FMR is a major drawback and occurs in 10-50% of patients. The REFORM-MR registry aims to investigate the effectiveness of standardized papillary muscle relocation and ring annuloplasty and to identify the risk factors associated with recurrent FMR. METHODS: REFORM-MR is a prospective, multicenter registry that enrols consecutive FMR patients across five sites in Germany. All patients with FMR and restricted movement of leaflets during systole (i.e., type IIIb mitral regurgitation) undergoing standardized subannular repair in combination with mitral valve annuloplasty are included in the study. The primary objective is to examine the effect of combined papillary muscle relocation and ring annuloplasty on the recurrence of FMR at 2 years postoperatively. The secondary objectives are MACCE rate, reinterventions on the mitral valve and cardiac-related mortality in the study cohort. Echocardiography core-lab and MRI core-lab will provide anonymized analysis of the imaging data in the REFORM-MR registry. Student's t-test or Mann-Whitney U test for continuous variables and the Chi-Square or Fisher exact test for categorical variables are used for group comparisons. Kaplan-Meier analyses is performed for survival and safety outcomes. RESULTS: As of May 2021, a total of 97 patients were enrolled across five sites in Germany. CONCLUSIONS: The results of this study will help define the outcomes of combined papillary muscle relocation and ring annuloplasty in the FMR treatment in a multicentre setting and to improve the understanding of the limitations of subannular repair procedures while treating patients with type III FMR. Trial registration clinicaltrials.gov Identifier: NCT03470155.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Imageamento por Ressonância Magnética , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento , Ventrículos do Coração/fisiopatologia
16.
Artigo em Inglês | MEDLINE | ID: mdl-36018270

RESUMO

OBJECTIVES: Calcified or fibrotic cusps in patients with bicuspid aortic valves and aortic regurgitation complicate successful aortic valve (AV)-repair. Aortic valve neocuspidization (AVNeo) with autologous pericardium offers an alternative treatment to prosthetic valve replacement. We compared patients with regurgitant bicuspid valves undergoing AV-repair or AVNeo. METHODS: We retrospectively analysed patients with regurgitant bicuspid valves undergoing AV-repair or AVNeo. We focused on residual regurgitation, pressure gradients and effective orifice area, determined preoperatively and at discharge. RESULTS: AV-repair was performed in 61 patients (mean age: 43.2 ± 11.3 years) and AVNeo in 22 (45.7 ± 14.1). Prior to the operation patients of the AV-repair group showed severe regurgitation in 38 cases (62.3%) and moderate in 23 (37.6%); in the AVNeo group, all patients exhibited severe regurgitation. Postoperatively, 57 patients (93.4%) patients had no or mild regurgitation after AV-repair and 21 (95.4%) after AVNeo. In AVNeo-patients, peak (10.6 ± 3.1 mmHg vs 22.7 ± 11 mmHg, P< 0.001) and mean pressure gradients (5.9 ± 2 mmHg vs 13.8 ± 7.3 mmHg, P < 0.001) were significantly lower and the orifice area significantly larger (2.9 ± 0.8 cm2 vs 1.9 ± 0.7 cm2, P < 0.001) compared to repair. CONCLUSIONS: Compared to AV-repair, patients AVNeo showed lower mean pressure gradients and larger orifice areas at discharge. The functional result was not different.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Humanos , Adulto , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Hemodinâmica , Resultado do Tratamento
17.
Eur J Cardiothorac Surg ; 62(6)2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36005853

RESUMO

OBJECTIVES: Neointimal hyperplasia might affect systemic-to-pulmonary shunt failure in infants with complex cyanotic congenital heart disease. The aim of this study was to elucidate histopathologic changes in polytetrafluoroethylene shunts and to determine whether increased neointimal formation is associated with early interventions comprising balloon dilatation, stent implantation and shunt revision. Furthermore, we intended to identify clinical factors associated with increased neointimal proliferation. METHODS: Removed shunts were processed for histopathological analysis. Slides were stained with hematoxylin/eosin and Richardson. Immunohistochemistry was performed with anti-alpha-smooth muscle actin and anti-CD68. Non-parametric analysis and univariable regressions were performed to identify clinical factors associated with neointimal hyperplasia and shunt stenosis. RESULTS: Fifty-seven shunts (39 modified Blalock-Taussig anastomosis, 8 right ventricle-to-pulmonary artery anastomosis, 10 central shunts) were analysed. Area of neointimal proliferation within the shunt was in median 0.75 mm2 (interquartile range, 0.3-1.57 mm2) and relative shunt stenosis in median 16.7% (interquartile range, 6.7-30.8%). Neointimal hyperplasia and shunt stenosis correlated with each other and were significantly greater in the group that required early interventions and shunt revision. Univariable linear regression identified smaller shunt size and lower acetylsalicylic acid dosage as factors to be associated with greater neointimal proliferation and shunt stenosis. CONCLUSIONS: In infants with complex cyanotic congenital heart disease, neointimal hyperplasia in systemic-to-pulmonary shunts is associated with early interventions comprising balloon dilatation, stent implantation and shunt revision. Smaller shunt size and lower aspirin dosage are associated with increased neointimal proliferation.


Assuntos
Cardiopatias Congênitas , Lactente , Criança , Humanos , Hiperplasia , Constrição Patológica , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/cirurgia , Artéria Pulmonar/anormalidades , Ventrículos do Coração/cirurgia , Hipóxia
18.
J Card Surg ; 37(10): 2999-3005, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35790024

RESUMO

BACKGROUND: Isolated tricuspid valve endocarditis (TVE) is a rare disease which is managed medically in most patients. Only in specific cases, surgical intervention becomes necessary. Hence, data about surgical outcomes are sparse. This study reports on the operative experience in patients with isolated TVE over a period of 20 years. METHODS: We retrospectively analyzed 32 patients with isolated TVE who underwent surgery from February 2001 to June 2021 at the German Heart Centre Munich. RESULTS: Thirty-day mortality was 3.1%. Overall survival was 89.9± 5.5% at 1 year and 76.9 ± 8.5% at 5 years. Cumulative incidence for reoperation was 11.1 ± 6.0% at 5 years. Four patients (12.5%) were treated for recurrent endocarditis. Tricuspid valve repair (TVr) was achieved in 16 patients (50%). If the subvalvular apparatus (n = 10) was involved, tricuspid valve replacement was performed more frequently. CONCLUSIONS: Mortality in patients with isolated TVE undergoing cardiac surgery is high. In half of the cases, TVr was achieved but was less likely in patients with affected subvalvular apparatus.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Endocardite/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
19.
Heart Vessels ; 37(12): 2083-2092, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35802181

RESUMO

Given the recent surge in transcatheter heart valve replacement (THVR), cardiac surgeons will surely face the challenge of eventual explantation. The aim of this study was to determine indications for reoperation, while exploring pertinent technical aspects and survival after THV explantation in a cohort originally deemed high risk or even inoperable. Between February 2008 and March 2019, 31 patients with failed transcatheter aortic valve replacement (TAVR) underwent surgical explantations at our facility. Data were prospectively collected for retrospective analysis of procedural indications, technical issues, and postoperative survival. The major reason for TAVR removal was bioprosthetic valve failure (BVF) due to infective endocarditis (IE: 16/31 [51.6%]), non-structural (NSVD: 14/31 [45.2%]) and structural (SVD: 1/31 [3.2%]) valve deterioration accounting for the rest. Mean age at THV explantation was 76.3 ± 8.3 years, and median time from TAVR to explantation was 153 days (0 days-56.6 months). Median ICU and hospital stay were 6 days (1-44 days) and 23 days (8-62 days), respectively. Thirty-day and 1-year survival rates were 74.2% and 67.2%, respectively. Median follow-up interval after explantation was 364 days (3 days-80 months). Mean cardiopulmonary bypass time was 124.6 ± 46.8 min, and mean aortic cross-clamp time was 84.3 ± 32.9 min. There was no need for unplanned aortic root repair owing to tissue damage during dissection of the TAVR from surrounding tissue. The most common reason for THV explantation was (a) BVF for IE and (b) BVF secondary to NSVD. Although 30-day and 1-year mortality rates in this multimorbid cohort were predictably high, no procedural mortalities occurred.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco
20.
J Card Surg ; 37(10): 3110-3116, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35870166

RESUMO

INTRODUCTION: Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) depicts an encouraging new technique for the surgical treatment of aortic valve pathologies. The current study analyzes the early hemodynamic outcome of AVneo compared with surgical aortic valve replacement (SAVR) using the Abbott/St. Jude Trifecta aortic valve biological prostheses. METHODS: All patients who underwent either AVNeo or SAVR between March 2017 and April 2020 were included. Exclusion criteria were emergency cases, endocarditis, redo- or additional root procedures. Main endpoints were differences between the two groups in terms of the effective orifice area (EOA) and the effective orifice area index (EOAI) at discharge. RESULTS: During the study period, 105 AVNeo patients and 458 SAVR patients met the inclusion criteria. EOA was significantly higher in the AVNeo group (2.4 cm2 ± 0.8 vs. 2.1 cm2 /m2 ± 0.6 in the SAVR group, respectively; p < .001). Multiple regression analysis, including AVNeo, annulus size, bicuspid valve, preoperative stenosis, left ventricular ejection fraction (LVEF), and diastolic diameter (LVEDD) found two factors, which favor larger EOA: Annulus size (p < .0001) and AVneo (p = .005). EOAI was significantly higher in the AVNeo group (1.23 ± 0.4 vs. 1.02 cm2 /m2 ± 0.3, respectively; p < .001). Multiple regression analysis for EOAI showed effects for AVneo (p = .005) and bicuspid valve (p = .029). Mean pressure gradients (MPG) were lower in the AVNeo group than in the SAVR group (AVNeo: MPG = 8.0 mmHg ± 3.6 vs. SAVR: MPG = 8.3 mmHg ± 3.6), but this finding did not reach statistical significance (p = .091). CONCLUSIONS: AVNeo shows significantly larger EOA and EOAI compared to SAVR using the Abbott/St. Jude Trifecta aortic valve biological prostheses.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pericárdio/transplante , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA