1.
J Thorac Cardiovasc Surg ; 142(2): 390-5.e1, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21295314

RESUMO

OBJECTIVE: There is a need for fast, minimally invasive sutureless replacement of mitral valves. METHODS: Unchanged FDA-approved biological valve prostheses were sutured to Nitinol attachment rings (Endosmart, Stutensee, Germany) that were covered with textile (devices). The lower flange of the device was stretched in ice water and maintained in a stretched position with stretching sutures. In 9 acute pig experiments through a limited left thoracotomy, a single suture was placed around the mitral annulus, the device was positioned, the annular suture tied, the stretching sutures retracted, and the device activated by warm saline. Position of the device, heart and valve function, coronary arteries, left ventricular outflow tract, and surrounding structures were observed with transoesophageal echocardiography, left ventricular and coronary angiograms, and pathologic examination at autopsy. RESULTS: The devices could be easily navigated to the mitral valve annulus and actuated within seconds. Three devices were placed with warm blood in the operative field and were tilted or dislocated at autopsy. In the other 6 devices, transesophageal echocardiography and left ventricular and coronary angiography demonstrated normal prosthetic valve and heart function, without valvular or para-device leakage, and with normal aortic valve and coronary arteries. At autopsy in these 6 cases, the devices were strongly fixed at the anatomic mitral valve annulus, without abnormalities of the device, heart valve prosthesis, left ventricular outflow tract, or aortic valve ostium. CONCLUSIONS: Nitinol attachments rings combined with unchanged biological valve prostheses can make fast and strong sutureless replacement of the mitral valve feasible in acute pig experiments. Applicators that constrain and release the device mechanically need to be developed.


Assuntos
Ligas , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Mitral , Animais , Angiografia Coronária , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Desenho de Prótese , Suínos
2.
Interact Cardiovasc Thorac Surg ; 9(4): 672-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19605469

RESUMO

BACKGROUND: We recently demonstrated the first in-vitro cutting results of a minimal-invasive aortic valve resection tool. The current study was designed to assess the cutting accuracy of this new device improved by the implementation of a linear motor-based propulsion unit. METHODS: Native aortic valves of isolated swine hearts (valve diameter 17.8+/-0.9 mm, mean+/-S.D.) were artificially stenosed and calcified (n=7). Subsequently, valves were resected by the use of a new aortic valve resection tool. The cutting process was performed by fitting the instrument with foldable Nitinol cutting blades (diameter 15 mm) and two software-operated linear motors combined with separated manual rotation. Aortic valve area was measured pre- and postprocedure by software-guided binary area calculation. Aortic valve residue has been determined and the grade of accuracy has been assessed via calculating the average midpoint of the neoannulus. Furthermore, radial deviation of concentricity was calculated and cutting time was measured. RESULTS: Aortic valve resection was successful in all cases and nearly all leaflets (2.5+/-0.4) with a weight of 0.22+/-0.12 g were cut. Aortic valve area increased significantly (0.3+/-0.1 cm(2) vs. 1.1+/-0.2 cm(2), P<0.001) with a mean cutting time of 49.7+/-15.0 s. Mean lateral leaflet rim within the annulus was 3.2+/-3.2 mm. Cutting precision revealed a median deviation of the cutting ring from the desired position of 1.3+/-0.6 mm (y-axis) and 1.4+/-0.5 mm (x-axis). Median center deviation of the cutting ring was 2.6+/-0.8 mm. CONCLUSIONS: The present study clearly confirmed ability of an accelerated cutting of stenotic aortic valve by the aortic valve resection tool. Nearly all leaflets were cut and a small rim was left within the annulus, hence providing an ideal 'landing zone' for the new prosthesis. Nevertheless, the aortic valve resection tool should be enhanced by adding a centering mechanism, thus achieving a more precise cutting process in order to avoid secondary damage.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Instrumentos Cirúrgicos , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Teste de Materiais , Procedimentos Cirúrgicos Minimamente Invasivos , Suínos
3.
Artigo em Inglês | MEDLINE | ID: mdl-19431069

RESUMO

The use of minimally invasive techniques for aortic valve replacement (AVR) may be limited for severely calcified and degenerated stenotic aortic valves. A quick resection leaving a defined geometry would be advantageous. Therefore, a new minimally invasive resection tool was developed, using rotating foldable cutting edges. This report describes the first experimental in-vitro results of measuring turning moment and forces during cutting of test specimens. Nitinol cutting edges were mounted on a simplified version of the resection instrument. The instrument shaft was combined with an exchangeable gear (1:3.71 vs. 1:5.0), and an exchangeable screw thread for accurate feed motion (0.35 mm or 0.5 mm) was implemented. Furthermore, the option of an added stabilisation body (SB) to prevent strut-torsion during cutting was tested. Tests were performed upon specially designed test specimens, imitating native calcified aortic valves. Resection was successful in all 60 samples (12 samples for each of the five configurations). Mean resection time ranged from 18.7+/-1.0 s (gear 1:3.71, screw thread 0.5, with SB) to 29.3+/-4.6 s (gear 1:5, screw thread 0.35, with SB), mean maximum turning moment ranged from 2.1+/-0.2 Nm (gear 1:3.71, screw thread 0.35, with SB) to 2.8+/-0.4 (gear 1:5, screw thread 0.35, with SB), mean maximum force from 36.0+/-11.3 N (gear 1:3.71, screw thread 0.35, with SB) to 56.3+/-10.5 N (gear 1:3.71, screw thread 0.5, without SB) and mean number of required rotations from 41.3+/-2.9 (gear 1:3.71, screw thread 0.5, with SB) to 59.1+/-3.7 (gear 1:3.71, screw thread 0.35, without SB). In summary, the positive influence of the stabilisation body could be shown. Combining the right parameters, it is possible to limit maximum cutting forces to F(max)<50 N and maximum turning moments to M(max)< 3.0 N.


Assuntos
Ligas , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Valva Aórtica/patologia , Desenho de Equipamento , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Teste de Materiais , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fatores de Tempo
4.
Eur J Cardiothorac Surg ; 35(4): 622-7; discussion 627, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19233666

RESUMO

BACKGROUND: Aortic valve replacement (AVR) using extracorporeal circulation is currently the treatment of choice for symptomatic aortic stenosis. However, patients with multiple high-risk comorbid conditions may benefit from reduced ECC time by a simplified and faster resection in conjunction with quick sutureless valve implantation. METHODS: A prototype of a new minimally invasive aortic valve resection tool equipped with rotating and foldable Nitinol cutting edges was designed. Commercially available aortic valve bioprostheses were artificially calcified (group 1: moderate calcified, n=8, group 2: severely calcified, n=8). In vitro resection was performed using a 21mm cutting blade. Resection time (RT), maximum turning moment (MTM) and number of required rotations (NR) were measured. Furthermore, particle generation during the process of cutting was obtained and quantified. RESULTS: Aortic valve cutting could be obtained without any complications in all cases. Cutting process resulted in a RT of 15.5+/-3s in group 1 compared to 34.9+/-15s in group 2 (p=0.005), MTM was 3+/-0.6Nm in group 1 compared to 3.5+/-0.6Nm in group 2 (p=0.068) and NR were 30.6+/-2.3 in group 1 compared to 48.1+/-15.5 in group 2 (p=0.007). Particle generation was 1.77+/-0.17g in group 1 compared to 1.41+/-0.44g in group 2 (p=0.047). CONCLUSIONS: These first in vitro results confirm feasibility and accelerated aortic valve resection within 30s. This new concept holds promise for very fast AVR in combination with insertion of sutureless aortic valve prosthesis, targeting for ischemic times less than 10min in the open heart situation. Finally, resection and percutaneous AVR within 1min in the beating heart situation is envisioned.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Calcinose/cirurgia , Desenho de Equipamento , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fatores de Tempo
5.
Artigo em Inglês | MEDLINE | ID: mdl-19085189

RESUMO

Machining of shape memory alloys based on Nitinol (NiTi) creates difficulties due to its ductility and severe strain hardening. In this experiment, different cutting edges and grinding parameters were tested to optimize cutting results on NiTi-based blades intended for endovascular heart valve resection. The cutting procedure was performed using two counter-rotating circular NiTi blades of different diameter. A rotating/punching process should be performed. Different shapes (glazed, waved, and saw tooth), different grinding techniques (manual, manual grinder, and precise milling cutter) and additionally various velocities (50 and 200 rpm) were tested on specific test specimens. Cutting forces were measured and cutting quality was examined using digital microscopy. Preliminary tests with rotating blades showed superior results using cutting edges for the punching process (150 N vs. 200 N; n=7). In a second step special test specimens were tested. Maximum cutting-force was 265 N+/-20 N (mean+/-SD; n=7). Subsequently different shapes were tested at 50 and 200 rpm using the rotating/punching method regarding alternate grinding techniques. Cutting forces were 27 N+/-7.7 N for glazed blades (n=7) at 50 rpm and 18 N+/-4.7 N at 200 rpm, waved blades (n=7) required a maximum force of 18 N+/-5 N at 50 rpm and 11 N+/-3.3 N at 200 rpm, whereas saw tooth blades (n=7) needed 17 N+/-12.7 N at 50 rpm and 9 N+/-1.2 N at 200 rpm. Precise cutting quality was only seen when using glazed blades sharpened under accurate conditions with a high-speed milling cutter. Although shape memory alloys based on Nitinol are difficult to process, and well-defined grinding parameters do not exist, acceptable results can be reached using high-speed milling cutters. Best cutting quality can be observed by using glazed blades, performing a rotating/punching process at high velocities. Lower cutting forces can be observed by using other shape-types, however this leads to lower cutting quality. Therefore, further investigations on blade-machining and velocity-testing seem to be necessary to create optimal cutting results.


Assuntos
Ligas/química , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Valva Aórtica/cirurgia , Desenho de Equipamento , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Técnicas In Vitro , Microscopia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Controle de Qualidade
6.
J Thorac Cardiovasc Surg ; 134(6): 1508-12, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18023674

RESUMO

OBJECTIVE: There is a need for fast sutureless implantation of valve prostheses with a better outcome than that of current valved stents. METHODS: The suture ring of a St Jude mechanical valve prosthesis (St Jude Medical, Minneapolis, Minn) was replaced by a proprietary non-stent-based attachment ring made of Nitinol memory metal (Endosmart, Stutensee, Germany) and covered with textile. In acute pig experiments, the aortic valve was removed and the device was introduced in a temporary stretched shape and activated by removing constrainers and heating to reach its final attachment shape. RESULTS: The devices could be actuated within seconds. Echocardiography showed normal prosthetic valve and heart function. No paradevice leakage was demonstrated by supravalvular angiography. At autopsy, no abnormalities were found in the surrounding structures or valve prostheses. Pulling tests showed the strong adhesive power of Nitinol attachment rings withstanding up to 5 kg of pulling force. CONCLUSION: Nitinol memory metal attachment rings, covered with textile, around suture ring-denuded St Jude mechanical aortic valve prostheses enabled fast and strong sutureless implantation in acute pig experiments. Further studies in chronic animal models and humans are needed to determine long-term safety.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Ligas , Animais , Materiais Biocompatíveis , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Modelos Animais , Técnicas de Sutura , Suínos
7.
Gastrointest Endosc ; 62(3): 344-9, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16111949

RESUMO

BACKGROUND: Mediastinal abscesses after esophageal perforation or postoperative leakage nearly always require surgical intervention. METHODS: Patients with paraesophageal abscesses were treated with EUS-guided or endoscopic mediastinal puncture if the abscess was >2 cm and sepsis was present. Abscess cavities were entered with a 9.5-mm endoscope after balloon dilation to allow irrigation and drainage. Debris was removed with a Dormia basket. Concomitant pleural effusions were treated with transthoracic drains. Patients received intravenous antibiotics and enteral/parenteral nutrition. RESULTS: Twenty patients fulfilled the entry criteria. Simple drainage was sufficient in 4 cases, and puncture was impossible in one case. Of the 15 treated patients (age 39-76 years, 5 women) the etiology of perforation was Boerhaave's syndrome (n = 8), anastomotic leak (n = 3), and iatrogenic perforation (n = 4). Debridement was successful in all cases and required a median of 5 daily sessions (range 3-10). All patients became apyrexial, with a C-reactive protein < 5 mg/L within a median of 4 days (range 2-8 days). Esophageal defects were closed with endoclips (n = 7), fibrin glue (n = 4), metal stents (n = 1), or spontaneously healed (n = 3). One patient died from a massive pulmonary embolism one day after successful debridement (mortality 7%). No other complications were seen. Median follow-up was 12 months (range 3-40 months). CONCLUSIONS: Nonoperative endoscopic transesophageal debridement of mediastinal abscesses appears safe and effective.


Assuntos
Abscesso/cirurgia , Endossonografia/métodos , Perfuração Esofágica/complicações , Esofagoscopia/métodos , Doenças do Mediastino/etiologia , Doenças do Mediastino/cirurgia , Abscesso/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Desbridamento/métodos , Perfuração Esofágica/diagnóstico por imagem , Esôfago , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Doenças do Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Prospectivos , Medição de Risco , Resultado do Tratamento
8.
Chest ; 127(2): 438-42, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15705979

RESUMO

BACKGROUND: In planning lung cancer therapy, the possibility of mediastinal invasion merits attention. The results of CT and MRI in this respect are unsatisfactory, especially in determining aortic involvement. STUDY OBJECTIVES: To determine the validity of transesophageal echography in proving the invasion of lung cancer into the aortic wall. PATIENTS: Two hundred one patients with lung cancer abutting against the aorta were examined using transesophageal echography and CT. In 97 patients, the results of both imaging techniques were compared with the surgical/pathologic results. RESULTS: In a vast majority, transesophageal echography leads to a definitive result while CT remains equivocal. Controlled by surgical/pathologic results in 97 patients, transesophageal echography yielded a diagnostic accuracy of 91.8%. CONCLUSIONS: In lung cancer abutting against the aorta, the diagnostic procedure should be complemented by transesophageal echography if the therapeutic management depends on whether the aortic wall is invaded by the tumor or not.


Assuntos
Aorta Torácica/patologia , Carcinoma Broncogênico/diagnóstico por imagem , Carcinoma Broncogênico/patologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Pequenas/diagnóstico por imagem , Carcinoma de Células Pequenas/patologia , Ecocardiografia Transesofagiana , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Pleura/patologia , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X