1.
Appl Radiat Isot ; 155: 108921, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31629294

RESUMO

An internal consistency test of the calculation of coincidence-summing correction factors FC for volume sources is presented. The test is based on exact equations relating the values of FC calculated for three ideal measurement configurations. The test is applied to a number of 33 sets of FC values sent by 21 teams. Most sets passed the test, but not the results obtained using the quasi-point source approximation; in the latter case the test qualitatively indicated the magnitude of the bias of FC.

2.
Appl Radiat Isot ; 155: 108920, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31622844

RESUMO

The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed.

3.
Appl Radiat Isot ; 134: 51-55, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28673731

RESUMO

A method is presented for calculating the expected number of counts in peaks that have a large relative peak-area uncertainty and appear in measured gamma-ray spectra. The method was applied to calculations of the correction factors for peaks occurring in the spectra of radon daughters. It was shown that the factors used for correcting the calculated peak areas to their expected values decrease with an increasing relative peak-area uncertainty. The accuracy of taking the systematic influence inducing the correction factors into account is given by the dispersion of the correction factors corresponding to specific peaks. It was shown that the highest accuracy is obtained in the peak analyses with the GammaVision and Gamma-W software.

4.
J Environ Radioact ; 164: 337-343, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27552657

RESUMO

In the era of the energy saving policy (i.e. more air tight doors and windows), the radon exhaled from building materials tends to increase its concentration in indoor air, which increases the importance of the measurement of radon exhalation from building materials. This manuscript presents a novel method of the radon exhalation measurement using only a HPGe detector or any other gamma spectrometer. Comparing it with the already used methods of radon exhalation measurements, this method provides the measurement of the emanation coefficient, the radon diffusion length and the radon exhalation rate, all within the same measurement, which additionally defines material's radon protective properties. Furthermore it does not necessitate additional equipment for radon or radon exhalation measurement, which simplifies measurement technique, and thus potentially facilitates introduction of legal obligation for radon exhalation determination in building materials.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Materiais de Construção , Monitoramento de Radiação , Radônio/análise , Expiração
5.
Appl Radiat Isot ; 87: 73-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24360863

RESUMO

Coal as fossil fuel mainly contains naturally occurring radionuclides from the uranium and thorium series and (40)K. Use of coal, primarily in industry, as a result has dispersion of radioactive material from coal in and through air and water. The aim of this study was to determine the activity concentrations of natural radionuclides in coal samples from open pit mines "Kolubara" and to evaluate its effect on population health. The results showed that all measured and calculated values were below the limits recommended in international legislation.

6.
Appl Radiat Isot ; 70(9): 2112-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445105

RESUMO

The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed.


Assuntos
Algoritmos , Artefatos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/métodos , Radiometria/normas , Espectrometria gama/métodos , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência
7.
Appl Radiat Isot ; 70(9): 1860-2, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22405642

RESUMO

In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values.


Assuntos
Calibragem/normas , Radioisótopos/análise , Radioisótopos/química , Radiometria/normas , Internacionalidade , Estudos Longitudinais , Doses de Radiação , Padrões de Referência , Valores de Referência
8.
Appl Radiat Isot ; 70(9): 2154-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22436450

RESUMO

The direct measurement of the activities of (57)Co sources by application of the sum-peak method recently developed by Novkovic et al., is described in this paper. The comprehensive assessment of the uncertainty budget of the activity of the measured sources has been analyzed. The presented method is successfully tested using an HPGe spectrometer with efficiencies of 50%. The accuracy of this method is confirmed to be comparable with the commonly used methods of the activity measurement of (57)Co.


Assuntos
Algoritmos , Radioisótopos de Cobalto/análise , Radiometria/métodos , Meia-Vida , Doses de Radiação , Radiometria/instrumentação
9.
Appl Radiat Isot ; 68(7-8): 1433-4, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20022756

RESUMO

A simple and efficient method for determination of uranium content in surface soil samples contaminated with depleted uranium, by gamma ray spectrometry is presented. The content of natural uranium and depleted uranium, as well as the activity ratio (235)U/(238)U of depleted uranium, were determined in contaminated surface soil samples by application of this method.


Assuntos
Monitoramento de Radiação/métodos , Poluentes Radioativos do Solo/análise , Urânio/análise , Métodos , Espectrometria gama/métodos
10.
Appl Radiat Isot ; 66(6-7): 792-5, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18343144

RESUMO

A review of the calibration procedures of the semiconductor HPGe spectrometer is presented in this paper. Calibration standards were prepared using the standardized radioactive solution of the common monoenergetic radionuclides mixture and standardized multigamma (152)Eu solution. The matrix materials were spiked using the activated carbon, and homogenized mechanically or by suspension in C(2)H(5)OH. Experimentally determined efficiency curves were compared with those obtained by Monte Carlo simulation.

11.
J Environ Radioact ; 95(2-3): 75-85, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17383779

RESUMO

A method for determining the specific alpha activity of thick sources using a large area ZnS(Ag) scintillation detector is presented. In this method a quadratic relationship between the detector response and window thickness is assumed. This method provides a quick estimation of alpha activity in the sample, so it is an indicative method. The aim of this experimental work is to approve theoretical assumption and to develop a standard routine method for absolute alpha measurements of thick contaminated environmental sources. For this purpose reference material U(3)O(8) and spiked standards of soil were used. Measurements of contaminated soil samples from south Serbia showed the practical application of this method.


Assuntos
Contagem de Cintilação/métodos , Poluentes Radioativos do Solo/análise , Partículas alfa , Óxidos/análise , Monitoramento de Radiação , Compostos de Tório/análise , Compostos de Urânio/análise , Iugoslávia , Compostos de Zinco
12.
Appl Radiat Isot ; 64(6): 689-92, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16442294

RESUMO

The surface air activity concentration of 241Pu for the period May 01-15, 1986, for a monitoring site in Vinca, Belgrade was retrospectively estimated. The results were obtained by re-measurement of plutonium fraction alpha-spectrometric sources, with 236Pu as a tracer, used almost 13 years earlier for the determination of (239,240)Pu concentration in surface air immediately after the Chernobyl accident. The estimated 241Pu concentration, based on the 241Am in-growth method for air samples, ranged from 240 to 7800 microBq/m3. The average activity ratio 241Pu/(239,240)Pu originating from the Chernobyl accident at Belgrade site was approximately 100 at the collection time.


Assuntos
Poluentes Radioativos do Ar/análise , Acidente Nuclear de Chernobyl , Plutônio/análise , Centrais Elétricas , Liberação Nociva de Radioativos , Monitoramento Ambiental , Isótopos , Monitoramento de Radiação , Estudos Retrospectivos , Ucrânia , Iugoslávia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA