RESUMO
PURPOSE: To evaluate the agreement between 24-2 visual field (VF) test results obtained using the gaze analyzing perimeter (GAP; Findex) and the Humphrey field analyzer (HFA; Carl Zeiss Meditec). DESIGN: Cross-sectional study. PARTICIPANTS: Patients underwent HFA 24-2 for suspected or confirmed VF loss and were treated at the Kyoto University Hospital between December 2022 and July 2023. METHODS: Patients underwent consecutive VF tests on the same eye using HFA and GAP 24-2 tests. Bland-Altman analysis was used to compare GAP and HFA results. Examination points where the sensitivity measured using GAP was ≥ 10 dB higher than that measured using HFA were re-evaluated by referring back to the original gaze data; 2 ophthalmologists assessed whether the gaze moved linearly toward the new test target. MAIN OUTCOME MEASURES: Mean deviation (MD) and elapsed time on an individual basis and sensitivity on an examination point basis. RESULTS: Forty-seven eyes of 47 patients were analyzed. The correlation coefficient of the MD using HFA and GAP was 0.811 (95% confidence interval [CI]: 0.683-0.891). Bland-Altman analysis showed good agreement between HFA and GAP tests. The mean difference (95% limits of agreement) in MD between HFA and GAP results was -0.63 dB (-5.81 to 4.54 dB). Although no statistically significant differences were observed in the elapsed time (P = 0.99), measurements completed within 200 seconds were observed only in the GAP group (11 cases, 23.4%), who had significantly better HFA MD value than others (P = 0.001). On an examination point basis for sensitivity, the correlation coefficient between HFA and GAP was 0.691 (95% limits of agreement, 0.670-0.711). Original gaze data assessment revealed that the gaze moved linearly toward the new test target for 70.2% of the examination points with a sensitivity discrepancy. CONCLUSIONS: The results indicate that the GAP provides VF assessment outcomes comparable to those of the HFA. The GAP exhibited advantages in terms of testing time, particularly in patients with minimal VF impairment. Furthermore, the GAP records all eye movements, enabling the objective determination of VF abnormalities based on gaze patterns and facilitating easy posthoc verification. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Assuntos
Testes de Campo Visual , Campos Visuais , Humanos , Estudos Transversais , Feminino , Masculino , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Testes de Campo Visual/instrumentação , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Desenho de Equipamento , Adulto , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Idoso de 80 Anos ou maisRESUMO
PURPOSE: To investigate the prevalence and incidence of strabismus in the Japanese population by age group and to estimate the subtype proportions. DESIGN: A nationwide population-based cohort study. METHODS: This study investigated the number of cases with previous and new diagnoses of strabismus by age group between 2009 and 2020 using the National Database of Health Insurance Claims and Specific Health Checkups of Japan, which includes almost all (≥95%) medical claims data. We calculated the strabismus prevalence and 1-year incidence in 2019 and analyzed the proportion of each strabismus subtype. RESULTS: The strabismus prevalence was 2.154% (2 709 207/125 708 000; 95% CI, 2.152%-2.157%). It showed a bimodal distribution, with a high proportion in school and old ages (especially ≥75 years). Exotropia, esotropia, and cyclovertical strabismus proportions were 67.3%, 26.0%, and 6.7%, respectively. Cyclovertical strabismus was uncommon in patients aged ≤18 years (1.4%) and more common (10.2%) in those aged >18 years. The strabismus incidence in 2019 was 321 per 100 000 person-years (403 093/125 708 000; 95% CI, 320-322). The annual incidence proportion of cyclovertical strabismus as opposed to whole strabismus subtypes in patients aged >18 years (13.1%) was higher than that in those aged ≤18 years (1.4%). CONCLUSIONS: This is the first nationwide population-based cohort study to demonstrate strabismus's overall prevalence and incidence. The high prevalence of cyclovertical strabismus in adults compared with children may suggest that cyclovertical strabismus is a primarily age-related strabismus. The high prevalence of exotropia may indicate a genetic difference between Japanese and other ethnicities.
RESUMO
This study aimed to analyze the trends and factors influencing the number of ophthalmic surgeries in Japan using the open data from the National Database of Health Insurance Claims and Specific Health Checkups of Japan published by the Ministry of Health, Labour and Welfare. We calculated the number of cataract, glaucoma, and vitreoretinal surgeries, categorized by sex, age, and surgical type, for the fiscal years (FY) 2014 to 2020. The number of cataract surgeries remained stable at approximately 1.45 million cases from FY 2014 to 2018, increased to nearly 1.6 million cases in FY 2019, and decreased to 1.45 million cases in FY 2020. Among glaucoma surgeries, surgical treatments were increased 1.8 times over 7 years, from 33,000 to 60,000 cases. Laser treatment remained steady at around 55,000 cases from FY 2014 to 2017 and then increased to approximately 60,000 cases. The number of vitreoretinal surgeries was increased 1.2 times from FY 2014 to 2019, from 120,000 to 140,000, and decreased to 130,000 by FY 2020. Trends in ophthalmic surgeries over the past 7 years may be influenced by population aging, minimally invasive surgery, and the coronavirus disease pandemic. These findings have implications on surgical decision-making and resource allocation.
Assuntos
Extração de Catarata , Catarata , Glaucoma , Humanos , Idoso , Japão/epidemiologia , Seguro SaúdeRESUMO
During space missions, such as the prospective Mars mission, crew labor time is a strictly limited resource. The diet for such a mission (based on crops grown in a bioregenerative life support system) will require astronauts to prepare their meals essentially from raw ingredients. Time spent on food processing and preparation is time lost for other purposes. Recipe design and diet planning for a space mission should therefore incorporate the time required to prepare the recipes as a critical factor. In this study, videotape analysis of an experienced chef was used to develop a database of recipe preparation time. The measurements were highly consistent among different measurement teams. Data analysis revealed a wide variation between the active times of different recipes, underscoring the need for optimization of diet planning. Potential uses of the database developed in this study are discussed and illustrated in this work.