Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Ultrasound Obstet Gynecol ; 60(2): 200-206, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35468236

RESUMO

OBJECTIVE: To assess whether pregnancy-associated plasma protein-A (PAPP-A) alters or provides equivalent screening performance as placental growth factor (PlGF) when screening for preterm pre-eclampsia (PE) at 11-13 weeks of gestation. METHODS: This was a secondary analysis of a non-intervention screening study of 6546 singleton pregnancies that were screened prospectively for preterm PE in the first trimester between December 2016 and June 2018. Patient-specific risks for preterm PE were estimated by maternal history, mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI), PlGF and PAPP-A. A competing-risks model with biomarkers expressed as multiples of the median was used. All women and clinicians were blinded to the risk for preterm PE. The performance of screening for preterm PE using PlGF vs PAPP-A vs both PAPP-A and PlGF was assessed by comparing areas under the receiver-operating-characteristics (AUC) curves. McNemar's test was used to compare detection rate at a fixed false-positive rate (FPR) of 10%. RESULTS: PlGF and PAPP-A were measured in 6546 women, of whom 37 developed preterm PE. The AUC and detection rate at 10% FPR using PlGF in combination with maternal history, MAP and UtA-PI were 0.854 and 59.46%, respectively. The respective values were 0.813 and 51.35% when replacing PlGF with PAPP-A and 0.855 and 59.46% when using both PAPP-A and PlGF. Statistically non-significant differences were noted in AUC when replacing PlGF with PAPP-A (ΔAUC, 0.04; P = 0.095) and when using both PAPP-A and PlGF (ΔAUC, 0.002; P = 0.423). However, on an individual case basis, screening using PlGF in conjunction with maternal history, MAP and UtA-PI identified three (8.1%) additional pregnancies that developed preterm PE and that were not identified when replacing PlGF with PAPP-A. Screening using PAPP-A in addition to maternal history and other biomarkers did not identify any additional pregnancies. CONCLUSION: On an individual case basis, adoption of a screening strategy that uses PAPP-A instead of PlGF results in reduced detection of preterm PE, consistent with previous literature. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Pré-Eclâmpsia , Proteína Plasmática A Associada à Gravidez , Biomarcadores , Feminino , Humanos , Recém-Nascido , Fator de Crescimento Placentário , Gravidez , Primeiro Trimestre da Gravidez , Fluxo Pulsátil , Artéria Uterina/diagnóstico por imagem
4.
Ultrasound Obstet Gynecol ; 58(2): 214-220, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32730679

RESUMO

OBJECTIVE: To investigate whether gestational age at intervention (< or ≥ 16 weeks) and other factors affect the risk of loss of the cotwin after selective fetal reduction using radiofrequency ablation (RFA) in monochorionic (MC) pregnancy. METHODS: This was a single-center retrospective analysis of 63 consecutive RFA procedures performed at our institution from January 2011 to October 2019 for selective fetal reduction in complicated MC pregnancies. Indications for RFA were twin reversed arterial perfusion sequence (13 cases), twin-to-twin transfusion syndrome (12 cases), twin anemia-polycythemia sequence (two cases), selective fetal growth restriction (10 cases), discordant anomalies (17 cases) and multifetal pregnancy reduction in triplets or quadruplets with a MC pair (nine cases). Twenty-six (41.3%) of these procedures were performed before and 37 (58.7%) after 16 weeks. Potential factors that could affect the risk of loss of the cotwin, including gestational age at RFA, order of multiple pregnancy, amnionicity, indication for RFA and number of ablation cycles, were assessed first by univariate analysis and then by multivariate analysis. RESULTS: There were 17 (27.0%) cotwin losses. Ablation cycles numbering four or more was the only factor among those investigated to be associated with loss of the cotwin after RFA (P = 0.035; odds ratio, 5.21), while the indication for RFA, order of multiple pregnancy, amnionicity and gestational age at RFA had no effect. Comparing RFA performed at < 16 vs ≥ 16 weeks, there was no difference in the rate of cotwin loss (23.1% vs 29.7%; P = 0.558) or preterm prelabor rupture of the membranes before 34 weeks (7.7% vs 5.4%; P = 0.853), or in the median gestational age at delivery (36.2 vs 37.3 weeks; P = 0.706). CONCLUSIONS: RFA is a promising tool for early selective fetal reduction in MC pregnancy before 16 weeks. Four or more ablation cycles is a major risk factor for cotwin loss. Careful assessment pre- and post-RFA, together with proficient operative skills to minimize the number of ablation cycles, are the mainstay to ensure that this procedure is effective and safe. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Redução de Gravidez Multifetal , Gravidez Múltipla , Adulto , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Complicações Pós-Operatórias , Gravidez , Resultado da Gravidez , Trimestres da Gravidez , Ablação por Radiofrequência , Estudos Retrospectivos
5.
Ultrasound Obstet Gynecol ; 54(2): 190-198, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30381851

RESUMO

OBJECTIVE: To (1) evaluate the normal development of the Sylvian fissures in the anterior coronal view of the fetal brain at 18-30 weeks' gestation by transvaginal three-dimensional (3D) ultrasound, (2) develop reference ranges of measurements of the right and left Sylvian fissure angles during normal pregnancy at 18-30 weeks' gestation, and (3) examine intra- and interobserver repeatability of measurements of the right and left Sylvian fissure angles. METHODS: This was a prospective cross-sectional study of 422 women with a singleton pregnancy attending an ultrasound-based research clinic between March and December 2017. The entry criteria for the study were appropriately grown live fetus with no suspected structural and/or chromosomal defects between 18 + 0 and 30 + 6 weeks' gestation. Normal development of the Sylvian fissures was assessed in the anterior coronal plane of the fetal brain using transvaginal 3D volume multiplanar imaging. The coronal view was visualized as a single image from the three orthogonal views. Subsequently, the right and left Sylvian fissure angles were measured between a horizontal reference line (0°) and a line drawn along the upper side of the respective Sylvian fissure. Intra- and interobserver repeatability of the Sylvian fissure angle measurements was assessed by Bland-Altman plots. Reference equations were constructed for right and left Sylvian fissure angles for gestational age (GA) and head circumference (HC) using the Generalized Additive Models for Location Scale and Shape package. RESULTS: In the anterior coronal view of the fetal brain, an inward rotation of the upper portion of the Sylvian fissures was observed during the second and third trimesters of pregnancy. There was a significant negative polynomial association between the Sylvian fissure angles and GA and HC. Both Sylvian fissure angles crossed the reference line (zero), going from positive to negative, at around 25 weeks' gestation or at HC of 22 cm. Z-score difference between the smoothed percentiles of the right and left Sylvian fissure angles indicated that median, 10th and 90th smoothed percentiles were closest and almost the same for the GA-based references between 18 and 28 weeks and for the HC-based references between 14 and 24 cm. The intraclass correlation coefficient of the right and left Sylvian fissure angle measurements between the two sonographers was excellent at 0.993 (95% CI, 0.988-0.996) and 0.991 (95% CI, 0.985-0.995), respectively. On Bland-Altman analysis, the mean difference between the two sonographers in right Sylvian fissure angle measurement was 0.4° (95% CI, -10.2 to 10.1°) and in left Sylvian fissure angle it was 1.0° (95% CI, -9.6 to 11.6°). CONCLUSIONS: Assessment of the Sylvian fissure angles is highly reproducible. Sylvian fissure angle reference charts can serve as a screening tool for malformations of cortical development, guiding subsequent follow-up and referral for fetal brain magnetic resonance imaging and/or assessment by an expert neurosonologist. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Córtex Cerebral/anatomia & histologia , Córtex Cerebral/diagnóstico por imagem , Imageamento Tridimensional/instrumentação , Adulto , Córtex Cerebral/embriologia , Estudos Transversais , Feminino , Desenvolvimento Fetal/fisiologia , Idade Gestacional , Humanos , Variações Dependentes do Observador , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Ultrassonografia , Ultrassonografia Pré-Natal/métodos
7.
Ultrasound Obstet Gynecol ; 36(2): 136-40, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20201112

RESUMO

OBJECTIVE: To determine whether real-time three-dimensional (3D) ultrasound with Live xPlane imaging, which enables the simultaneous display of two real-time high-quality image planes, can assist both operators certified by The Fetal Medicine Foundation (FMF) and non-FMF-certified operators in acquiring a true midsagittal plane in the first trimester. METHODS: Eight operators, four of them FMF certified (FMF group) and the other four not (non-FMF group), were asked to acquire a fetal image that they believed to represent the true midsagittal plane using real-time 3D ultrasound with Live xPlane imaging as guidance. Each operator was asked to obtain such an image five times from each of five patients. A total of 200 images from 40 patients were obtained and stored for subsequent analysis. All pregnancies were between 11 + 0 and 13 + 6 weeks of gestation. The angle between the falx cerebri and vertical axis (angle of deviation) was then measured by a single operator. A true midsagittal section was defined as an angle of deviation equal to 0 degrees. The angle of deviation and the time taken to acquire each image were compared between FMF and non-FMF groups. RESULTS: The median angle of deviation for each operator ranged from 1.2 degrees to 3.4 degrees. There was no significant difference in this angle between those who were FMF certified and those who were not (2.0 degrees vs. 2.2 degrees, P = 0.463). The interquartile range of the angle of deviation was also similar between the FMF- and non-FMF-certified operators. Although the time taken for image acquisition was longer among the non-FMF-certified operators (median, 45.5 s vs. 32.0 s), this difference did not reach statistical significance (P = 0.107). CONCLUSION: Live xPlane imaging can provide a tool to assist the acquisition of a true midsagittal plane and to determine how true a 'midsagittal' plane really is.


Assuntos
Cerebelo/diagnóstico por imagem , Competência Clínica/normas , Síndrome de Down/diagnóstico por imagem , Medição da Translucência Nucal/normas , Cerebelo/embriologia , Feminino , Idade Gestacional , Humanos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador , Gravidez , Primeiro Trimestre da Gravidez , Ultrassonografia Pré-Natal/métodos
8.
Ultrasound Obstet Gynecol ; 34(5): 534-7, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19821447

RESUMO

OBJECTIVE: To describe a technique to rapidly visualize the in-plane view of the fetal interventricular septum (IVS) to enable the identification of a ventricular septal defect (VSD). METHODS: One hundred and fifty-one women were invited to participate after their routine fetal morphology scan, including four suspected to have congenital cardiac defects which were confirmed postnatally. A standard examination protocol using real-time three-dimensional (3D) echocardiography with live xPlane imaging was developed. The ability of this new technology to examine the ventricular septum was investigated. RESULTS: The in-plane view of the fetal IVS was visualized successfully in 150 (99.3%) cases by real-time 3D echocardiography with live xPlane imaging, including 82 (54.3%) cases with the spine posterior and 68 (45.7%) cases with the spine anterior. The in-plane view of the IVS successfully visualized the VSDs in three fetuses with VSD and displayed the intact IVS in one fetus with transposition of the great arteries without VSD. CONCLUSION: We describe live xPlane imaging, a simple method for the real-time assessment of the in-plane view of the IVS that has the potential to enhance the diagnostic accuracy of fetal cardiac examination.


Assuntos
Ecocardiografia Tridimensional/métodos , Coração Fetal/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Septos Cardíacos/diagnóstico por imagem , Adulto , Ecocardiografia Tridimensional/instrumentação , Feminino , Doenças Fetais/diagnóstico por imagem , Idade Gestacional , Cardiopatias Congênitas/diagnóstico por imagem , Comunicação Interventricular/embriologia , Septos Cardíacos/embriologia , Humanos , Interpretação de Imagem Assistida por Computador , Gravidez , Adulto Jovem
9.
Ultrasound Obstet Gynecol ; 32(7): 855-9, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18973236

RESUMO

OBJECTIVES: To study the deviation of presumed midsagittal sections of the fetal head from the true image plane, to compare whether certification (by The Fetal Medicine Foundation (FMF), UK) has an effect on the degree of this deviation, and to investigate the impact of imperfect midsagittal sections on nuchal translucency thickness (NT) measurement. METHODS: Eight sonographers, four of them FMF-certified (Group A) and the other four not (Group B), were asked to obtain image sections which they believed to represent true midsagittal sections of the fetal head and neck in five patients each. Three-dimensional volume datasets were acquired for subsequent analysis. The angle between the falx cerebri and the vertical axis was measured and the effect of this angle on NT measurement was assessed. RESULTS: The mean angle of deviation was significantly lower among those who were FMF-certified (5.7 degrees vs. 14.7 degrees, P < 0.001). The 1.8% underestimation of NT by Group A was not statistically significant (P = 0.76), while in Group B the NT could not be measured when the angle of deviation was 14.7 degrees. CONCLUSIONS: FMF-certified operators obtain a better midsagittal section compared with non-certified operators. The minor deviation from the true midsagittal section by certified operators has no significant effect on the value of NT measurement. This study could provide a model for operator training and auditing.


Assuntos
Cerebelo/diagnóstico por imagem , Competência Clínica/normas , Pescoço/diagnóstico por imagem , Medição da Translucência Nucal , Ultrassonografia Pré-Natal/métodos , Cerebelo/embriologia , Certificação , Feminino , Humanos , Imageamento Tridimensional , Pescoço/embriologia , Variações Dependentes do Observador , Gravidez , Primeiro Trimestre da Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA