Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 16(15): 18686-18692, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38573309

RESUMO

Redox flow batteries (RFBs) are membrane-separated rechargeable flow cells with redox electrolytes, offering the potential for large-scale energy storage and supporting renewable energy grids. Yet, creating a cost-effective, high-performance RFB system is challenging. In this work, we investigate an Fe/Mn RFB alkaline system based on the [(TEA)Fe-O-Fe(TEA)]3-/4- and MnO4-/2- redox couples with a theoretical cell voltage of ∼1.43 V. This combination has not been systematically studied previously, but it can lead to a very low-cost and sustainable materials for high energy storage. Constant current cycling tests were performed at ±41 mA cm-2 between 20% and 80% SOC over 800 h (400 cycles) with an apparent Coulombic efficiency (CE) approaching 100%, while the voltage efficiency (VE) gradually decreased from ∼75.3% to ∼61.4% due to increasing internal resistances. The voltage efficiency loss can be mitigated through a periodic acid treatment to remove MnO2 deposits from the separator.

2.
ACS Appl Mater Interfaces ; 15(1): 1148-1156, 2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36563037

RESUMO

Nonflammable eutectic solvents show great potential to enhance the concentrations of the redox-active materials and the cell voltages for redox flow batteries (RFBs). Herein, we report a promising redox-active eutectic electrolyte (1.5 M total redox species) with viologen and ferrocene derivatives where both of the redox reactions are reversible with a maximum open-circuit voltage of 1.35 V and an energy density of 15.1 Wh L-1, which is relevant to large-scale energy storage. The charge-discharge (from 75 to 25% state of charge) characteristics in a flow cell (0.15 M negolyte and 0.3 M posolyte) showed that it can be cycled with consistent discharge capacity for 12 h (19 cycles), beyond which pressure-driven crossover between the posolyte and negolyte reservoirs leads to capacity decay. This study points to promising new directions toward eutectic electrolyte development for RFBs where we demonstrate increasing the polarity, functionalizing the redox molecules, and separating redox intermediates to prevent undesired side reactions can make improvements in operating cell voltage, energy density, and cyclability.

3.
Sensors (Basel) ; 22(11)2022 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35684899

RESUMO

The application of direct current (DC) produces a rapid and reversible nerve conduction block. However, prolonged injection of charge through a smooth platinum electrode has been found to cause damage to nervous tissue. This damage can be mitigated by incorporating high-capacitance materials (HCM) (e.g., activated carbon or platinum black) into electrode designs. HCMs increase the storage charge capacity (i.e., "Q value") of capacitive devices. However, consecutive use of these HCM electrodes degrades their surface. This paper evaluates activated carbon and platinum black (PtB) electrode designs in vitro to determine the design parameters which improve surface stability of the HCMs. Electrode designs with activated carbon and PtB concentrations were stressed using soak, bend and vibration testing to simulate destructive in vivo environments. A Q value decrease represented the decreased stability of the electrode-HCM interface. Soak test results supported the long-term Q value stabilization (mean = 44.3 days) of HCM electrodes, and both HCMs displayed unique Q value changes in response to soaking. HCM material choices, Carbon Ink volume, and application of Nafion™ affected an electrode's ability to resist Q value degradation. These results will contribute to future developments of HCM electrodes designed for extended DC application for in vivo nerve conduction block.


Assuntos
Carvão Vegetal , Platina , Capacitância Elétrica , Eletricidade , Eletrodos
4.
IEEE Trans Neural Syst Rehabil Eng ; 27(5): 836-845, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30951474

RESUMO

Direct current (DC) nerve block has been shown to provide a complete block of nerve conduction without unwanted neural firing. Previous work shows that high capacitance electrodes can be used to safely deliver a DC block. Another way of delivering DC safely is through a separated interface nerve electrode (SINE), such that any reactive species that are generated by the passage of DC are contained in a vessel away from the nerve. This design has been enhanced by using a high capacitance carbon "slurry" as the electrode in the external vessel to extend the capacity of the electrode (CSINE). With this new design, it was possible to provide 50 min of continuous nerve block without recharge while still maintaining complete recovery of neural signals. Up to 46 C of charge delivery was applied for a total of 4 h of nerve block with complete recovery. Because of the extended delivery time, it was possible to explore several properties of DC block that would not be revealed without the capability of a long-duration continuous block. It was possible to achieve complete block at lower values of DC if the block was applied for a longer period of time. Depending on the amount of charge applied during the block, the recovery was delayed for a period of time before complete force recovery was restored. These new properties provide novel techniques for device development to optimize charge delivery time and device powering concerns.


Assuntos
Estimulação Elétrica/instrumentação , Eletrodos , Bloqueio Nervoso , Condução Nervosa , Algoritmos , Animais , Materiais Biocompatíveis , Bioengenharia , Carbono , Desenho de Equipamento , Grafite , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático
5.
Chem Soc Rev ; 47(23): 8721-8743, 2018 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-30298880

RESUMO

Rechargeable redox flow batteries are being developed for medium and large-scale stationary energy storage applications. Flow batteries could play a significant role in maintaining the stability of the electrical grid in conjunction with intermittent renewable energy. However, they are significantly different from conventional batteries in operating principle. Recent contributions on flow batteries have addressed various aspects, including electrolyte, electrode, membrane, cell design, etc. In this review, we focus on the less-discussed practical aspects of devices, such as flow fields, stack and design considerations for developing high performance large-scale flow batteries. Finally, we provide suggestions for further studies on developing advanced flow batteries and large-scale flow battery stacks.

6.
Med Biol Eng Comput ; 54(1): 191-203, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26358242

RESUMO

Direct current (DC) can briefly produce a reversible nerve conduction block in acute experiments. However, irreversible reactions at the electrode-tissue interface have prevented its use in both acute and chronic settings. A high capacitance material (platinum black) using a charge-balanced waveform was evaluated to determine whether brief DC block (13 s) could be achieved repeatedly (>100 cycles) without causing acute irreversible reduction in nerve conduction. Electrochemical techniques were used to characterize the electrodes to determine appropriate waveform parameters. In vivo experiments on DC motor conduction block of the rat sciatic nerve were performed to characterize the acute neural response to this novel nerve block system. Complete nerve motor conduction block of the rat sciatic nerve was possible in all experiments, with the block threshold ranging from -0.15 to -3.0 mA. DC pulses were applied for 100 cycles with no nerve conduction reduction in four of the six platinum black electrodes tested. However, two of the six electrodes exhibited irreversible conduction degradation despite charge delivery that was within the initial Q (capacitance) value of the electrode. Degradation of material properties occurred in all experiments, pointing to a possible cause of the reduction in nerve conduction in some platinum black experiments .


Assuntos
Eletrodos , Bloqueio Nervoso/métodos , Humanos
7.
J Neural Eng ; 11(5): 056012, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25115572

RESUMO

OBJECTIVE: Kilohertz frequency alternating current (KHFAC) waveforms have been shown to provide peripheral nerve conductivity block in many acute and chronic animal models. KHFAC nerve block could be used to address multiple disorders caused by neural over-activity, including blocking pain and spasticity. However, one drawback of KHFAC block is a transient activation of nerve fibers during the initiation of the nerve block, called the onset response. The objective of this study is to evaluate the feasibility of using charge balanced direct current (CBDC) waveforms to temporarily block motor nerve conductivity distally to the KHFAC electrodes to mitigate the block onset-response. APPROACH: A total of eight animals were used in this study. A set of four animals were used to assess feasibility and reproducibility of a combined KHFAC + CBDC block. A following randomized study, conducted on a second set of four animals, compared the onset response resulting from KHFAC alone and combined KHFAC + CBDC waveforms. To quantify the onset, peak forces and the force-time integral were measured during KHFAC block initiation. Nerve conductivity was monitored throughout the study by comparing muscle twitch forces evoked by supra-maximal stimulation proximal and distal to the block electrodes. Each animal of the randomized study received at least 300 s (range: 318-1563 s) of cumulative dc to investigate the impact of combined KHFAC + CBDC on nerve viability. MAIN RESULTS: The peak onset force was reduced significantly from 20.73 N (range: 18.6-26.5 N) with KHFAC alone to 0.45 N (range: 0.2-0.7 N) with the combined CBDC and KHFAC block waveform (p < 0.001). The area under the force curve was reduced from 6.8 Ns (range: 3.5-21.9 Ns) to 0.54 Ns (range: 0.18-0.86 Ns) (p < 0.01). No change in nerve conductivity was observed after application of the combined KHFAC + CBDC block relative to KHFAC waveforms. SIGNIFICANCE: The distal application of CBDC can significantly reduce or even completely prevent the KHFAC onset response without a change in nerve conductivity.


Assuntos
Estimulação Elétrica/métodos , Contração Muscular/fisiologia , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Bloqueio Nervoso/métodos , Condução Nervosa/fisiologia , Nervos Periféricos/fisiologia , Animais , Estudos de Viabilidade , Força Muscular/fisiologia , Ratos , Ratos Sprague-Dawley
8.
J Am Chem Soc ; 133(44): 17582-5, 2011 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-21985430

RESUMO

Electrochemical reactions are normally initiated in solution by metal electrodes such as Pt, which are expensive and limited in supply. In this Communication, we demonstrate that an atmospheric-pressure microplasma can act as a gaseous, metal-free electrode to mediate electron-transfer reactions in aqueous solutions. Ferricyanide is reduced to ferrocyanide by plasma electrons, and the reduction rate is found to depend on discharge current. The ability to initiate and control electrochemical reactions at the plasma-liquid interface opens a new direction for electrochemistry based on interactions between gas-phase electrons and ionic solutions.

9.
J Power Sources ; 196(2): 820-826, 2011 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20953345

RESUMO

The objective of this work was to demonstrate a micro-fabricated hydrogen storage module for micro-power systems. Hydrogen storage materials were developed as thin-film inks to be compatible with an integrated manufacturing process. Performance and durability of storage modules were evaluated. Further, applications were demonstrated for a nickel-hydrogen battery and a micro-fabricated hydrogen-air PEM fuel cell. The ink making process, in which polymer binders and solvents were added to the palladium-treated alloys, slightly decreased the storage capacities, but had little effect on the activation properties of the treated alloys. After 5000 absorption/desorption cycles under hydrogen, the hydrogen storage capacities of the thin-film inks remained high. Absorption/desorption behavior of the ink was tested in the environment of a new type nickel-hydrogen battery, in which it would in contact with 26wt% KOH solution, and the ink showed no apparent degradation. Storage modules were used as the successfully as hydrogen source for PEM fuel cell.

10.
J Power Sources ; 196(2): 827-834, 2011 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20967132

RESUMO

The objective of this work was to develop a hydrogen storage module for onboard electrical power sources suitable for use in micro power systems and micro-electro-mechanical systems (MEMS). Hydrogen storage materials were developed as thin-film inks to be compatible with an integrated manufacturing process. Important design aspects were (a) ready activation at sub-atmospheric hydrogen pressure and room temperature and (b) durability, i.e. capable of hundreds of absorption/desorption cycles and resistance to deactivation on exposure to air. Inks with palladium-treated intermetallic hydrogen storage alloys were developed and are shown here to be compatible with a thin-film micro-fabrication process. These hydrogen storage modules absorb hydrogen readily at atmospheric pressure, and the absorption/desorption rates remained fast even after the ink was exposed to air for 47 weeks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA