Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.207
Filtrar
3.
J Soc Cardiovasc Angiogr Interv ; 3(2): 101202, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39132213

RESUMO

Background: Little is known about the bleeding risk associated with cangrelor use in patients with myocardial infarction (MI) who are exposed to an oral P2Y12 inhibitor before coronary angiography. Methods: Cangrelor in Acute MI: Effectiveness and Outcomes (CAMEO) is an observational registry studying platelet inhibition for patients with MI. Upstream oral P2Y12 inhibition was defined as receipt of an oral P2Y12 inhibitor within 24 hours before hospitalization or in-hospital before angiography. Among cangrelor-treated patients, we compared bleeding after cangrelor use through 7 days postdischarge between patients with and without upstream oral P2Y12 inhibitor exposure. Results: Among 1802 cangrelor-treated patients with MI, 385 (21.4%) received upstream oral P2Y12 inhibitor treatment. Of these, 101 patients (33.8%) started cangrelor within 1 hour, 103 (34.4%) between 1 and 3 hours, and 95 (31.8%), >3 hours after in-hospital oral P2Y12 inhibitor administration; the remaining received an oral P2Y12 inhibitor before hospitalization. There was no statistically significant difference in rates of bleeding among cangrelor-treated patients with and without upstream oral P2Y12 inhibitor exposure (6.5% vs 8.8%; adjusted odds ratio [OR], 0.62; 95% CI, 0.38-1.01). Bleeding was observed in 5.0%, 10.7%, and 3.2% of patients treated with cangrelor <1, 1 to 3, and >3 hours after the last oral PY12 inhibitor dose, respectively; bleeding rates were not statistically different between groups (1-3 hours vs <1 hour: adjusted OR, 2.70; 95% CI, 0.87-8.32; >3 hours vs <1 hour: adjusted OR, 0.65; 95% CI, 0.15-2.85). Conclusions: Bleeding risk was not observed to be significantly higher after cangrelor treatment in patients with and without upstream oral P2Y12 inhibitor exposure.

4.
Artigo em Inglês | MEDLINE | ID: mdl-39109463

RESUMO

BACKGROUND: In 2019, the US Food and Drug Administration (FDA) approved transcatheter aortic valve replacement (TAVR) for low-risk patients with symptomatic severe tricuspid aortic stenosis. However, bicuspid aortic valve (BAV) patients were included only in single-arm registries of pivotal low-risk TAVR trials, resulting in limited data for this subgroup. METHODS: The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and the first FDA-approved investigational device exemption trial to evaluate the feasibility of TAVR with balloon-expandable or self-expanding valves in low-risk patients with symptomatic severe BAV stenosis. This analysis reports 2-year follow-up, assessing the primary outcome of all-cause mortality and evaluating clinical outcomes. RESULTS: From 2016 to 2019, a total of 72 low-risk patients diagnosed with symptomatic, severe BAV stenosis underwent TAVR across six centers. Six patients were lost to follow-up. At 2-year follow-up, mortality was 1.5% (1 of 66 patients). Among the remaining 65 patients, four experienced nondisabling strokes (6.2%), while 2 (3.1%) developed infective endocarditis. No new permanent pacemakers were required beyond the 30-day follow-up, and no patients, including those with endocarditis, needed aortic valve re-intervention. At the 2-year echocardiography follow-up (n = 65), 27.8% of BAV patients showed mild aortic regurgitation, with none exhibiting moderate or severe regurgitation. The mean aortic gradient was 12.1 ± 4.1 mmHg, and the mean valve area was 1.7 ± 0.5 cm². CONCLUSION: The 2-year follow-up confirms commendable clinical outcomes of TAVR in patients with bicuspid aortic stenosis, establishing its evident safety.

5.
Am J Cardiol ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39053723

RESUMO

A metanalysis of available randomized controlled trials and observational studies comparing self-expanding and balloon-expandable bioprostheses in patients with small aortic annulus and aortic stenosis for short and midterm hemodynamic and clinical outcomes was performed. 21 studies with a total 8647 patients (self-expanding, n=4,336 patients vs balloon-expandable, n= 4,311 patients) were included. Self-expanding bioprostheses had a lower post-operative mean gradient at 30 days (MD -5.16, 95%CI 4.7-5.5, p value <0.001) and at one year (MD -6.6, 95%CI 6.1-7.03, p value <0.001), with a larger indexed Effective Orifice Area (0.17, 95%CI 0.13-0.22, p value <0.001and 0.17, 95%CI 0.08-0.27, p value < 0.001) at both time intervals. Balloon-expandable bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (RR 1.07, 95%CI 1.04-1.09, p value < 0.001; RR 1.07, 95%CI 1.04-1.11, p value <0.001). 30-day and 1 year paravalvular leaks (RR 0.99, 95%CI 0.98-0.99, p value < 0.001; RR 0.89, 95%CI 0.82-0.95, p value <0.001) and permanent pacemaker implantation (RR 0.97, 95%CI .94-0.99, p value 0.01, I2= 40%,) were lower in balloon-expandable group. Balloon-expandable bioprostheses were associated with lower risk of in-hospital stroke (RR 0.99, 95%CI 0.98-1,p value= 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior haemodynamic performance but higher rates of PVL, PPI and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe PPM.

6.
Artigo em Inglês | MEDLINE | ID: mdl-39013705

RESUMO

BACKGROUND: PROTECT IV is a current enrolling randomized controlled trial evaluating high-risk percutaneous coronary intervention (HR-PCI) with prophylactic Impella versus no Impella to reduce the composite primary endpoint of all-cause death, stroke, myocardial infarction (MI), or cardiovascular hospitalization. In a PROTECT IV-like cohort of patients who underwent HR-PCI without Impella, we aimed to report the rate of major adverse events to determine whether the trial is adequately powered. METHODS AND RESULTS: A total of 700 patients meeting similar inclusion/exclusion criteria of PROTECT IV who underwent HR-PCI without Impella at a single tertiary center from 2008 to 2022 were included in the analysis. The composite rates of all-cause death, MI, target lesion revascularization, and target vessel revascularization at 1, 2, and 3 years were estimated using the Kaplan-Meier method, and the results were used to calculate the sample size under the constant hazard ratio assumption and expected number of events to be observed used in planning PROTECT IV. The primary endpoint occurred in 30.8 % of patients at 2 years. PROTECT IV assumes a hazard ratio of 0.75 using a multivariate Cox regression, which, under a 5 % level and 90 % power, yields 516 events. This implies a 2-year primary outcome rate of 50 % for the non-Impella arm. CONCLUSION: Therefore, PROTECT IV estimates that a sample size of 1252 patients is required for Impella to be declared superior to the non-Impella group. Using our observed 2-year outcome of 30.8 %, we estimate that PROTECT IV requires 1966 patients, demonstrating that PROTECT IV is probably underpowered.

7.
EuroIntervention ; 20(13): e793-e805, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949240

RESUMO

Periprocedural stroke after transcatheter aortic valve implantation (TAVI) remains a significant issue, which is associated with high morbidity, and is increasingly important as intervention shifts to younger and lower-risk populations. Over the last decade of clinical experience with TAVI, the incidence of periprocedural stroke has stayed largely unchanged, although it is prone to underreporting due to variation in ascertainment methods. The aetiology of stroke in TAVI patients is multifactorial, and changing risk profiles, differing study populations, and frequent device iterations have made it difficult to discern consistent risk factors. The objective of this review is to analyse and clarify the contemporary published literature on the epidemiology and mechanisms of neurological events in TAVI patients and evaluate potential preventive measures. This summary aims to improve patient risk assessment and refine case selection for cerebral embolic protection devices, while also providing a foundation for designing future trials focused on stroke prevention.


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Estenose da Valva Aórtica/cirurgia , Medição de Risco , Valva Aórtica/cirurgia , Incidência , Resultado do Tratamento , Dispositivos de Proteção Embólica
8.
Am J Cardiol ; 225: 4-9, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38871158

RESUMO

The benefit of mechanical circulatory support with Impella (Abiomed, Inc., Danvers, Massachusetts) for high-risk percutaneous coronary intervention (HR-PCI) is uncertain. PROTECT III registry data showed improved outcomes with Impella compared with historical data (PROTECT II) but lack a direct comparison with the HR-PCI cohort without Impella support. We retrospectively identified patients meeting the PROTECT III inclusion criteria for HR-PCI and compared this group (non-Impella cohort [NonIMP]) with the outcomes data from the PROTECT III registry (Impella cohort). Baseline differences were balanced using inverse propensity weighting. The coprimary outcome was major adverse cardiac events (MACE) in-hospital and at 90 days. A total of 283 patients at great risk did not receive Impella support; 200 patients had 90-day event ascertainment and were included in the inverse propensity weighting analysis and compared with 504 patients in the Impella cohort group. After calibration, few residual differences remained between groups. The primary outcome was not different in-hospital (3.0% vs 4.8%, p = 0.403) but less in NonIMP at 90 days (7.5% vs 13.8%, p = 0.033). Periprocedural vascular complications, bleeding, and transfusion rate did not differ between groups; however, acute kidney injury occurred more frequently in the NonIMP group (10.5% vs 5.4%, p = 0.023). In conclusion, under identical HR-PCI inclusion criteria for Impella use in PROTECT III, an institutional non-Impella-supported HR-PCI cohort showed similar MACE in-hospital but fewer MACE at 90 days, whereas there was no signal for periprocedural harm with Impella use. These results do not support routine usage of Impella for patients with HR-PCI.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea , Sistema de Registros , Humanos , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Pontuação de Propensão , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Doença da Artéria Coronariana/cirurgia , Mortalidade Hospitalar
9.
Am J Cardiol ; 225: 52-60, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38906395

RESUMO

Spontaneous coronary artery dissection (SCAD) is a rare cause of ST-segment elevation myocardial infarction (STEMI), predominantly affecting women. Because primary percutaneous coronary intervention (PPCI) is reserved for a select group of patients, vulnerable and minority patients may experience delays in appropriate management and adverse outcomes. We examined the racial differences in the outcomes for patients with SCAD who underwent PPCI for STEMI. Records of patients aged ≥18 years who underwent PPCI for SCAD-related STEMI between 2016 and 2020 were identified from the National Inpatient Sample database. Clinical, socioeconomic, and hospital characteristics were compared between non-White and White patients. Weighted multivariate analysis assessed the association of race with inpatient mortality, length of stay (LOS), and hospitalization costs. The total weighted estimate of patients with SCAD-STEMI who underwent PPCI was 4,945, constituting 25% non-White patients. Non-White patients were younger (56 vs 60.7 years, p <0.001); had a higher prevalence of diabetes, acute renal failure, and obesity; and were more likely to be uninsured and be in the lowest income group. Inpatient mortality (7.7% vs 8.4%, p = 0.74) and hospitalization costs ($34,213 vs $31,858, p = 0.27) were similar for non-White and White patients, and the adjusted analysis did not show any association between the patients' race and inpatient mortality (odds ratio 0.60, 95% confidence interval [CI] 0.32 to 1.13, p = 0.11) or hospitalization costs (ß [ß coefficient]: 215, 95% CI -4,193 to 4,623, p >0.90). Similarly, there was no association between the patients' race and LOS (incident rate ratio 1.20, 95% CI 1.00 to 1.45, p = 0.054). The weighted multivariate analysis showed that age; clinical co-morbidities such as diabetes, acute renal failure, valvular dysfunction, and obesity; low-income status; and hospitalization in the western region were associated with adverse outcomes. In conclusion, our study does not show any differences in inpatient mortality, LOS, and hospitalization costs between non-White and White patients who underwent PPCI for SCAD-related STEMI.


Assuntos
Anomalias dos Vasos Coronários , Mortalidade Hospitalar , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/estatística & dados numéricos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/epidemiologia , Anomalias dos Vasos Coronários/cirurgia , Estados Unidos/epidemiologia , Doenças Vasculares/epidemiologia , Doenças Vasculares/congênito , Doenças Vasculares/cirurgia , Tempo de Internação/estatística & dados numéricos , Idoso , Disparidades em Assistência à Saúde/estatística & dados numéricos , Custos Hospitalares/estatística & dados numéricos , Estudos Retrospectivos , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia
12.
Catheter Cardiovasc Interv ; 104(2): 247-251, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38860616

RESUMO

In the absence of standardized management guidelines, coronary artery aneurysms (CAAs) present therapeutic challenges. Percutaneous coronary intervention (PCI) is rarely explored, especially in giant aneurysms with persistent angina, where surgery might be presumed as a preferred option. We describe the technical aspects and feasibility of PCI using Gore Viabahn expanded polytetrafluoroethylene (ePTFE)-covered nitinol self-expanding stents in a 66-year-old woman with a complex medical history and an enlarging, symptomatic right coronary artery aneurysm. The case was complicated by endoleak after the first stent, but intravascular ultrasound guidance enabled the precise deployment of additional stents, resulting in the successful exclusion of the aneurysm. This case demonstrates steps to successful CAA PCI with Gore Viabahn ePTFE-covered nitinol self-expanding stents and emphasizes that in unsuitable surgical candidates, PCI might be a potential alternative for symptomatic CAAs.


Assuntos
Ligas , Aneurisma Coronário , Desenho de Prótese , Ultrassonografia de Intervenção , Humanos , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/cirurgia , Aneurisma Coronário/terapia , Idoso , Feminino , Resultado do Tratamento , Stents Metálicos Autoexpansíveis , Angiografia Coronária , Politetrafluoretileno , Intervenção Coronária Percutânea/instrumentação , Stents , Angioplastia Coronária com Balão/instrumentação
13.
Circ Cardiovasc Interv ; 17(7): e014143, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38853766

RESUMO

Bioprosthetic aortic valve thrombosis is frequently detected after transcatheter and surgical aortic valve replacement due to advances in cardiac computed tomography angiography technology and standardized surveillance protocols in low-surgical-risk transcatheter aortic valve replacement trials. However, evidence is limited concerning whether subclinical leaflet thrombosis leads to clinical adverse events or premature structural valve deterioration. Furthermore, there may be net harm in the form of bleeding from aggressive antithrombotic treatment in patients with subclinical leaflet thrombosis. This review will discuss the incidence, mechanisms, diagnosis, and optimal management of bioprosthetic aortic valve thrombosis after transcatheter aortic valve replacement and bioprosthetic surgical aortic valve replacement.


Assuntos
Valva Aórtica , Bioprótese , Fibrinolíticos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Fibrinolíticos/efeitos adversos , Fibrinolíticos/administração & dosagem , Incidência , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Medição de Risco , Valor Preditivo dos Testes
14.
Artigo em Inglês | MEDLINE | ID: mdl-38845281

RESUMO

Since the advent of coronary stents, two of the most common long-term complications after percutaneous coronary intervention (PCI) are in-stent restenosis (ISR) and stent thrombosis (ST). Although the rates of ST have been nearly abolished and ISR rates have declined with the current gold-standard second-generation drug-eluting stents (DES), late ISR of DES remains a valid concern in the field of interventional cardiology. The drug-coated balloon (DCB) is a non-stent technology that relies on the concept of targeted homogeneous drug delivery from an inflated balloon to restore luminal vascularity, treat atherosclerosis, and overcome some limitations of PCI, including ISR and prolonged dual antiplatelet therapy to prevent ST by leaving nothing behind. Most clinical evidence on coronary DCBs predominantly comes from small, randomized data and registries using paclitaxel DCBs for ISR and de novo lesions in the coronary space. Since 2014, outside the United States, DCBs have been approved for the treatment of ISR, with a class I recommendation by the European Society of Cardiology. The Food and Drug Administration very recently approved the Agent DCB to treat ISR in patients with coronary artery disease in the US. Additionally, recent randomized clinical data also showed DCB's safety and efficacy for the treatment of de novo small-vessel disease and high-bleeding-risk patients, while their role for other clinical situations including acute coronary syndrome, large-vessel disease, bifurcation lesions, and long-diffuse distal lesions is currently under investigation. Herein, we review the evidence-based role of DCBs in the treatment of coronary lesions and offer future perspectives.

15.
Catheter Cardiovasc Interv ; 104(1): 34-43, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38713867

RESUMO

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.


Assuntos
Pressão Sanguínea , Aprovação de Equipamentos , Hipertensão , Artéria Renal , Simpatectomia , United States Food and Drug Administration , Humanos , Estados Unidos , Simpatectomia/efeitos adversos , Simpatectomia/instrumentação , Hipertensão/fisiopatologia , Hipertensão/cirurgia , Artéria Renal/inervação , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Rim/irrigação sanguínea , Comitês Consultivos , Desenho de Equipamento , Fatores de Risco
16.
Catheter Cardiovasc Interv ; 104(1): 125-133, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38769727

RESUMO

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fatores de Risco , Recuperação de Função Fisiológica , Vigilância de Produtos Comercializados , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Hemodinâmica
18.
Artigo em Inglês | MEDLINE | ID: mdl-38789341

RESUMO

BACKGROUND: The intricate relationship between mental health disorders, notably anxiety and depression, and chest pain associated with non-obstructive coronary artery disease has become a focus of investigation. METHODS: This study from the Coronary Microvascular Disease Registry (CMDR) evaluated the association of mental health disorders and coronary microvascular dysfunction (CMD) among patients with angina with no obstructive coronary artery disease (ANOCA) who had undergone comprehensive invasive physiological testing for CMD. Clinical data regarding baseline characteristics, comorbidities, and noninvasive cardiac testing were obtained from chart review. The primary outcome of interest was the potential relationship between mental health diagnoses and the presence of CMD. RESULTS: Of patients included in the CMDR, 27 % (41/152) had at least one documented mental health disorder diagnosis (International Classification of Diseases, Tenth Revision codes) and CMD. There was no difference in mental health diagnosis prevalence between CMD-positive and CMD-negative patients (21.1 % vs. 28.9 %, p = 0.34). The most common mental health diagnoses were depression (15.8 %) and anxiety (15.8 %). Furthermore, 46.3 % (19/41) of patients with mental health disorders were prescribed psychiatric medications, with the most common being benzodiazepines (26.8 %). CONCLUSION: Patients with chest pain not due to CMD did not have an increased prevalence of mental health disorders compared with patients with ANOCA due to CMD, challenging the notion of a psychosomatic component in the pathogenesis of ANOCA.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38789342

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) is associated with various inflammatory conditions that worsen endothelial dysfunction. This study aimed to investigate the relationship between CMD and inflammation using common inflammatory markers derived from complete blood count (CBC) analysis. METHODS: Information was gathered from the Coronary Microvascular Disease Registry to examine the neutrophil-to-lymphocyte ratio (NLR), eosinophil-to-monocyte ratio (EMR), and monocyte-to-high-density lipoprotein ratio (MHR) in a cohort of patients with angina who showed non-obstructive coronary arteries and underwent invasive physiological assessments for CMD. RESULTS: Of the 171 patients studied, 126 were CMD-negative and 45 were CMD-positive, constituting two groups of interest. The average age of all patients was 61.7 ± 11.1 years, and 63.7 % were female. No significant differences were observed between the two groups in terms of baseline characteristics, cardiovascular risk factors, or potential anti-inflammatory medications. Furthermore, there were no statistically significant differences in NLR (2.54 ± 3.71 vs. 2.52 ± 2.28, p = 0.97), EMR (0.3 ± 0.21 vs. 0.34 ± 0.29, p = 0.31), or MHR (0.02 ± 0.01 vs. 0.01 ± 0.01, p = 0.54) between CMD-positive and CMD-negative patients. CONCLUSION: Our findings did not show a noteworthy connection between CMD and inflammation, as suggested by various simple CBC-based biomarkers.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38789343

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) has been implicated as a potential mechanism in the pathophysiology of different clinical presentations, including ischemia and no obstructive coronary artery disease (INOCA), myocardial infarction and nonobstructive coronary arteries (MINOCA), stress cardiomyopathy, heart failure, and myocarditis. There are limited data about the role of CMD in cancer therapy-related cardiovascular toxicities. CASE PRESENTATIONS: Four women with a diagnosis of active cancer receiving treatment who developed subsequent MINOCA or INOCA presented for cardiac catheterization. Upon coronary angiography showing no obstructive coronary arteries, coronary function testing was performed to evaluate for CMD. METHODS: Coronary physiology was assessed measuring non-hyperemic (resting full-cycle ratio [RFR]) and hyperemic (fractional flow reserve [FFR]) indices using a physiologic pressure wire. The wire also measured coronary flow reserve (CFR), index of microcirculatory resistance (IMR), and RFR using thermodilution technology. CMD was confirmed if the CFR was <2.5 and the IMR was >25. RESULTS: Among 4 patients with diagnosis of active cancer presenting with chest pain, there was no evidence of obstructive coronary artery disease, leading to separate diagnoses of INOCA, MINOCA, stress cardiomyopathy, and myocarditis. We found CMD in 2 patients (1 with INOCA and 1 with immune checkpoint inhibitor-related myocarditis). CONCLUSIONS: CMD may play a role in cardiovascular toxicities. Further coronary physiology studies are needed to understand the mechanisms of cancer therapy-related cardiovascular toxicity and CMD, as well as optimal preventive and treatment options.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA