RESUMO
BACKGROUND: Highly sensitized pediatric patients awaiting heart transplantation experience longer wait times and thus higher waitlist mortality. Similarly, children less than 2 years of age have increased waitlist times and mortality when compared to their older peers. To improve the likelihood of successful transplantation in these patients, various strategies have been utilized, including peri-operative plasmapheresis. However, limited data exists comparing plasmapheresis techniques for antibody reduction. This study's aim was to compare the in vitro magnitude of isohemagglutinin titers (IT) and human leukocyte antigen (HLA) antibody removal and the time required between membrane-based plasmapheresis (MP) and centrifuge-based plasmapheresis (CP) incorporated into the extracorporeal (EC) circuit. METHODS: Two MP (Prismaflex) and two CP (Spectra Optia, Terumo BCT) circuits were incorporated into four separate EC circuits primed with high titer, highly sensitized type O donor whole blood. Assays were performed to determine baseline IT and anti-HLA antibodies and then at 30-minute increments until completion of the run (two plasma volume exchanges) at two hours. RESULTS: There was a decrease in anti-A and anti-B IgM and IgG titers with both MP and CP. Mean anti-A and anti-B titer reduction was by 4.625 titers (93.7% change) and 4.375 titers (93.8% change) using MP and CP, respectively. At 2 h of apheresis, CP reduced 62.5% of all ITs to ≤ 1:4, while MP reduced 50% of ITs to ≤ 1:4. Additionally, reduction of anti-HLA class II antibody to mean fluorescence intensity (MFI) <3000 was achieved with both MP and CP. At 2 h of apheresis, CP reduced MFI by 2-3.5 fold and MP reduced MFI by 1.7-2.5 fold. Both demonstrated similar hemolytic and thrombotic profiles. CONCLUSIONS: In this in vitro plasmapheresis model of IT and anti-HLA antibody reduction, both MP and CP incorporated into the EC circuit can be used quickly and effectively to reduce circulating antibodies. While CP may have some greater efficiency, further study is necessary to verify this in vivo.
Assuntos
Transplante de Coração , Hemaglutininas , Humanos , Criança , Antígenos HLA , Plasmaferese , Transplante de Coração/métodos , Rejeição de Enxerto/prevenção & controleRESUMO
The Crescent dual lumen right atrial (RA) cannula has recently been introduced for the support of pediatric patients in need of venovenous extracorporeal membrane oxygenation (VV ECMO) support. We present the first pediatric case series illustrating utility of the Crescent RA cannula in the pediatric patient population at a single institution over a 10 month period. From December 2021 to August 2022, six pediatric patients were adequately supported on seven VV ECMO runs at our institution with the Crescent RA cannula. ECMO cannulation, circuit design, anticoagulation management, ECMO circuit pressures, flow rates, and recirculation were similar to our standard of care for VV ECMO. The Crescent RA cannula can be used safely and effectively to provide adequate support for pediatric patients requiring VV ECMO.
Assuntos
Fibrilação Atrial , Oxigenação por Membrana Extracorpórea , Humanos , Criança , Catéteres , Cateterismo , Átrios do CoraçãoRESUMO
A diverse and equitable working environment is desirable. In 2011, a survey was distributed to all female perfusionists in the United States. This survey suggested that the female perfusionists share the same difficulties as women in the labor force. The role of women in society in general is clearly changing. Female perfusionists have been part of that evolution. Promoting equality and respecting diversity are central to life today. A follow-up survey was distributed to evaluate the status and the change in gender stereotypes in the field of perfusion over the past 10 years. Women make up nearly half of the U.S. labor force and 35.7% of the present perfusion workforce in North America (1,077 certified women). Women make 82 cents for every dollar that men earn and this disparity widens for women with more education. The purpose of this survey was to poll women in perfusion to evaluate concerns and opinions in their careers and to compare to the 2011 survey results. In December 2021, a 39-question survey (surveymonkey.com, San Mateo, CA) was made available to all female perfusionists in North American via social media websites (Facebook.com, Perfusion.com, LinkedIn.com, Perflist, Perfmail, and FPP Listserv). There were 384 responses to the 2021 survey compared to the 538 responses in 2011. About 32.1% of the survey participants have been used in perfusion for more than 20 years; 37.6% have earned a master's degree compared to 2011, where 18.3% had master's level education; 72.5% are the financial providers for their family with 44.2% earning $101-150,000.00 and 40.3% greater than $200,000.00, which is a significant change from 2011; 61.5% consider themselves under moderate stress compared to 63.0% in 2011; 94.3% take call on a regular basis; and 74.1% feel they miss essential family functions because of their schedules. Similarly, 62.8% felt discriminated against because of gender compared to 50.9% in 2011. This survey suggests that the female perfusionists have shown to be assertive (72% are the primary financial supporter of their families) and competent in the field of cardiovascular perfusion (nearly 40% have masters degrees). Further analysis is needed to discern whether female perfusionists are treated with comparable respect as their male colleagues when 50.0% report some discrimination or harassment in their workplace.
Assuntos
Certificação , Feminino , Masculino , Humanos , Estados Unidos , Perfusão/métodos , Recursos Humanos , Inquéritos e QuestionáriosRESUMO
The conduct of cardiopulmonary bypass in neonatal, infant, and pediatric patients continuously evolves as new devices and innovative techniques are introduced. Since 1989, periodic pediatric perfusion surveys have been conducted to ascertain practice patterns involving demographics, equipment, and perfusion techniques. The goal of this current project is to provide an updated perspective on international pediatric and congenital perfusion practice since the last survey conducted in 2016. In July 2021, a 100-question perfusion survey was distributed to 284 pediatric cardiac surgery centers using a secure web browser-based data application. Each center was given a unique survey hyperlink to ensure one response per institution and to monitor the response rate. Centers were given 1 month to complete the survey and electronic reminders were sent weekly to nonrespondents. After the survey was closed, information from completed surveys was exported to a software program for analysis. Responses were received from 153 of 284 pediatric centers for a response rate of 54%. Sixty respondents (39%) were from North American (NA) centers while 93 respondents (61%) were from non-North American (NNA) centers. The vast majority of centers use a roller head arterial pump (93%), hollow fiber oxygenators with open reservoirs (86%), and integrated arterial line filters (73%). The use of modified ultrafiltration was reported by 76% of centers. Ninety-two percent of centers reported the use of selective antegrade cerebral perfusion for aortic arch repairs. The N + 1 staffing model was most prevalent (52%), followed by two perfusionists per case (33%). Periodic surveys continue to be a useful modality in assessing regional variation in pediatric perfusion practice. This survey marked the first time the majority of responses came from non-North American institutions. Identifying these practice patterns may aid in the development of, and adherence to, regional standards and guidelines. This would foster the reduction of variation in practice and potentially improve patient safety.