Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 49(10): 2617-2620, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748119

RESUMO

Fourier ptychographic microscopy (FPM) needs to realize well-accepted reconstruction by image segmentation and discarding problematic data due to artifacts caused by vignetting. However, the imaging results have long suffered from uneven color blocks and the consequent digital stitching artifacts, failing to bring satisfying experiences to researchers and users over the past decade since the invention of FPM. In fact, the fundamental reason for vignetting artifacts lies in that the acquired data does not match the adopted linear-space-invariant (LSI) forward model, i.e., the actual object function is modulated by a quadratic phase factor during data acquisition, which has been neglected in the advancement of FPM. In this Letter, we rederive a linear-space-variant (LSV) model for FPM and design the corresponding loss function for FPM, termed LSV-FPM. Utilizing LSV-FPM for optimization enables the efficient removal of wrinkle artifacts caused by vignetting in the reconstruction results, without the need of segmenting or discarding images. The effectiveness of LSV-FPM is validated through data acquired in both 4f and finite conjugate single-lens systems.

2.
Opt Express ; 31(18): 29826-29842, 2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37710774

RESUMO

Fourier ptychographic microscopy (FPM) is a spatial-temporal-modulation high-throughput imaging technique via a sequential angle-varied LED illumination. Therefore, the illuminator is one of the key components and the design of this illuminator is significant. However, because of the property of spherical wave, partial coherence, and aperture-induced vignetting, the acquired images must be processed in blocks first, and rely on parallel reconstruction via a graphics processing unit (GPU). The high cost makes it unappealing compared with commercial whole slide imaging system via a low-cost central processing unit (CPU). Especially, the vignetting severely destroys the space-invariant model and induces obvious artifacts in FPM, which is the most difficult problem. The conventional method is to divide the field of view (FOV) into many tiles and omit those imperfect images, which is crude and may discards low frequency information. In this paper, we reevaluated the conditions of vignetting in FPM. Through our analysis, the maximum side length of FOV is 0.759 mm for a single full-FOV reconstruction via a 4×/0.1 NA objective and a 4 mm spacing LED array in theory, while almost 1.0 mm can be achieved in practice due to the tolerance of algorithm. We found that FPM system can treat the vignetting coefficient Vf below 0.1 as brightfield images and Vf lager than 0.9 as darkfield images, respectively. We reported an optimized distribution for designing an illuminator without vignetting effect according to the off-the-shelf commercial products, which can reconstruct full FOV in one time via a CPU. By adjusting the distribution of LED units, the system could retrieve the object with the side length of FOV up to 3.8 mm for a single full-FOV reconstruction, which achieves the largest FOV that a typical 4×/0.1 NA objective with the field number of 22 mm can afford.

3.
Cells ; 11(9)2022 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-35563818

RESUMO

Fourier ptychographic microscopy (FPM) has risen as a promising computational imaging technique that breaks the trade-off between high resolution and large field of view (FOV). Its reconstruction is normally formulated as a blind phase retrieval problem, where both the object and probe have to be recovered from phaseless measured data. However, the stability and reconstruction quality may dramatically deteriorate in the presence of noise interference. Herein, we utilized the concept of alternating direction method of multipliers (ADMM) to solve this problem (termed ADMM-FPM) by breaking it into multiple subproblems, each of which may be easier to deal with. We compared its performance against existing algorithms in both simulated and practical FPM platform. It is found that ADMM-FPM method belongs to a global optimization algorithm with a high degree of parallelism and thus results in a more stable and robust phase recovery under noisy conditions. We anticipate that ADMM will rekindle interest in FPM as more modifications and innovations are implemented in the future.


Assuntos
Algoritmos , Microscopia , Análise de Fourier , Microscopia/métodos , Projetos de Pesquisa
4.
Chem Commun (Camb) ; 53(51): 6891-6894, 2017 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-28607968

RESUMO

An ionic liquid dual-ion battery with pure 1-butyl-1-methylpiperidinium bis(trifluoromethylsulfonyl)imide as the electrolyte was developed, which exhibited a high discharge plateau initiated at 4.4 V, a well-defined capacity of 82 mA h g-1, an ultrawide charge/discharge potential range of 1.0-5.0 V and a superior stability of ∼100% capacity retention for 600 cycles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA