1.
Comput Biol Med ; 145: 105445, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35366468

RESUMO

With the increasing usage of wearable electrocardiogram (ECG) monitoring devices, it is necessary to develop models and algorithms that can analyze the large amounts of ECG data obtained in real-time. Accurate ECG delineation is key to assisting cardiologists in diagnosing cardiac diseases. The main objective of this study is to design a delineation model based on the encoder-decoder structure to detect different heartbeat waveforms, including P-waves, QRS complexes, T-waves, and No waves (NW), as well as the onset and offset of these waveforms. First, the introduction of a standard dilated convolution module (SDCM) into the encoder path enabled the model to extract more useful ECG signal-informative features. Subsequently, bidirectional long short-term memory (BiLSTM) was added to the encoding structure to obtain numerous temporal features. Moreover, the feature sets of the ECG signals at each level in the encoder path were connected to the decoder part for multi-scale decoding to mitigate the information loss caused by the pooling operation in the encoding process. Finally, the proposed model was trained and tested on both QT and LU databases, and it achieved accurate results compared to other state-of-the-art methods. Regarding the QT database, the average accuracy of ECG waveform classification was 96.90%, and an average classification accuracy of 95.40% was obtained on the LU database. In addition, average F1 values of 99.58% and 97.05% were achieved in the ECG delineation task of the QT and LU databases, respectively. The results show that the proposed ECG_SegNet model has good flexibility and reliability when applied to ECG delineation, and it is a reliable method for analyzing ECG signals in real-time.


Assuntos
Eletrocardiografia , Processamento de Sinais Assistido por Computador , Algoritmos , Arritmias Cardíacas , Eletrocardiografia/métodos , Humanos , Reprodutibilidade dos Testes
2.
Entropy (Basel) ; 23(7)2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34203339

RESUMO

Coronary heart disease (CHD) is the leading cause of cardiovascular death. This study aimed to propose an effective method for mining cardiac mechano-electric coupling information and to evaluate its ability to distinguish patients with varying degrees of coronary artery stenosis (VDCAS). Five minutes of electrocardiogram and phonocardiogram signals was collected synchronously from 191 VDCAS patients to construct heartbeat interval (RRI)-systolic time interval (STI), RRI-diastolic time interval (DTI), HR-corrected QT interval (QTcI)-STI, QTcI-DTI, Tpeak-Tend interval (TpeI)-STI, TpeI-DTI, Tpe/QT interval (Tpe/QTI)-STI, and Tpe/QTI-DTI series. Then, the cross sample entropy (XSampEn), cross fuzzy entropy (XFuzzyEn), joint distribution entropy (JDistEn), magnitude-squared coherence function, cross power spectral density, and mutual information were applied to evaluate the coupling of the series. Subsequently, support vector machine recursive feature elimination and XGBoost were utilized for feature selection and classification, respectively. Results showed that the joint analysis of XSampEn, XFuzzyEn, and JDistEn had the best ability to distinguish patients with VDCAS. The classification accuracy of severe CHD-mild-to-moderate CHD group, severe CHD-chest pain and normal coronary angiography (CPNCA) group, and mild-to-moderate CHD-CPNCA group were 0.8043, 0.7659, and 0.7500, respectively. The study indicates that the joint analysis of XSampEn, XFuzzyEn, and JDistEn can effectively capture the cardiac mechano-electric coupling information of patients with VDCAS, which can provide valuable information for clinicians to diagnose CHD.

3.
Entropy (Basel) ; 23(5)2021 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-33924819

RESUMO

Myocardial ischemia in patients with coronary artery disease (CAD) leads to imbalanced autonomic control that increases the risk of morbidity and mortality. To systematically examine how autonomic function responds to percutaneous coronary intervention (PCI) treatment, we analyzed data of 27 CAD patients who had admitted for PCI in this pilot study. For each patient, five-minute resting electrocardiogram (ECG) signals were collected before and after the PCI procedure. The time intervals between ECG collection and PCI were both within 24 h. To assess autonomic function, normal sinus RR intervals were extracted and were analyzed quantitatively using traditional linear time- and frequency-domain measures [i.e., standard deviation of the normal-normal intervals (SDNN), the root mean square of successive differences (RMSSD), powers of low frequency (LF) and high frequency (HF) components, LF/HF] and nonlinear entropy measures [i.e., sample entropy (SampEn), distribution entropy (DistEn), and conditional entropy (CE)], as well as graphical metrics derived from Poincaré plot [i.e., Porta's index (PI), Guzik's index (GI), slope index (SI) and area index (AI)]. Results showed that after PCI, AI and PI decreased significantly (p < 0.002 and 0.015, respectively) with effect sizes of 0.88 and 0.70 as measured by Cohen's d static. These changes were independent of sex. The results suggest that graphical AI and PI metrics derived from Poincaré plot of short-term ECG may be potential for sensing the beneficial effect of PCI on cardiovascular autonomic control. Further studies with bigger sample sizes are warranted to verify these observations.

4.
Comput Methods Programs Biomed ; 203: 106006, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33735660

RESUMO

BACKGROUND AND OBJECTIVE: Recent advances in deep learning have been applied to ECG detection and obtained great success. The spatial and temporal information from ECG signals is fused by combining convolutional neural networks (CNN) with recurrent neural network (RNN). However, these networks ignore the different contribution of local and global segments of a feature map extracted from the ECG and the correlation relationship between the above two segments. To address this issue, a novel convolutional neural network with non-local convolutional block attention module(NCBAM) is proposed to automatically classify ECG heartbeats. METHODS: Our proposed method consists of a 33-layer CNN architecture followed by a NCBAM module. Initially, preprocessed electrocardiogram (ECG) signals are fed into the CNN architecture to extract the spatial and channel features. Further, long-range dependencies of representative features along spatial and channel axis are captured by non-local attention. Finally, the spatial, channel and temporal information of ECG are fused by a learned matrix. The learned matrix is to mine rich relationship information across the above three types of information to make up for the different contribution. RESULTS AND CONCLUSION: The proposed method achieves an average F1 score of 0.9664 on MIT-BIH arrhythmia database, as well as AUC of 0.9314 and Fmax of 0.8507 on PTB-XL ECG database. Compared with the state-of-the-art attention mechanism based on the same public database, NCBAM achieves an obvious improvement in classifying ECG heartbeats. The results demonstrate the proposed method is reliable and efficient for ECG beat classification.


Assuntos
Algoritmos , Processamento de Sinais Assistido por Computador , Arritmias Cardíacas , Eletrocardiografia , Humanos , Redes Neurais de Computação
5.
Physiol Meas ; 41(11)2020 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-33080588

RESUMO

Objective: Coronary artery disease (CAD) is a common fatal disease. At present, an accurate method to screen CAD is urgently needed. This study aims to provide optimal detection models for suspected CAD detection according to the differences in medical conditions, so as to assist physicians to make accurate judgments on suspected CAD patients.Approach: Electrocardiogram (ECG) and phonocardiogram (PCG) signals of 32 CAD patients and 30 patients with chest pain and normal coronary angiograms (CPNCA) were simultaneously collected for this paper. For each subject, the ECG and PCG multi-domain features were extracted, and the results of Holter monitoring, echocardiography (ECHO), and biomarker levels (BIO) were obtained to construct a multi-modal feature set. Then, a hybrid feature selection (HFS) method was developed using mutual information, recursive feature elimination, random forest, and weight of support vector machine to obtain the optimal feature subset. A support vector machine with nested cross-validation was used for classification.Main results: Results showed that the Holter model achieved the best performance as a single-modal feature model with an accuracy of 82.67%. In terms of multi-modal feature models, PCG-Holter, PCG-Holter-ECHO, PCG-Holter-ECHO-BIO, and ECG-PCG-Holter-ECHO-BIO were the optimal bimodal, three-modal, four-modal, and five-modal models, with accuracies of 90.38%, 91.92%, 95.25%, and 96.67%, respectively. Among them, the ECG-PCG-Holter-ECHO-BIO model, which was constructed by combining ECG and PCG signals features with Holter, ECHO, and BIO examination results, achieved the best classification results with an average accuracy, sensitivity, specificity, and F1-measure of 96.67%, 96.67%, 96.67%, and 96.64%, respectively.Significance: The study indicated that multi-modal feature fusion and HFS can obtain more effective information for CAD detection and provide a reference for physicians to diagnose CAD patients.


Assuntos
Doença da Artéria Coronariana , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Humanos , Máquina de Vetores de Suporte
6.
Comput Biol Med ; 120: 103733, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32250860

RESUMO

Phonocardiogram (PCG) signals reflect the mechanical activity of the heart. Previous studies have reported that PCG signals contain heart murmurs caused by coronary artery disease (CAD). However, the murmurs caused by CAD are very weak and rarely heard by the human ear. In this paper, a novel feature fusion framework is proposed to provide a comprehensive basis for CAD diagnosis. A dataset containing PCG signals of 175 subjects was collected and used. A total of 110 features were extracted from multiple domains, and then reduced and selected. Images obtained by Mel-frequency cepstral coefficients were used as the input for the convolutional neural network for feature learning. Then, the selected features and the deep learning features were fused and fed into a multilayer perceptron for classification. The proposed feature fusion method achieved better classification performance than multi-domain features or deep learning features alone, with accuracy, sensitivity, and specificity of 90.43%, 93.67%, and 83.36%, respectively. A comparison with existing studies demonstrated that the proposed method was a promising noninvasive screening tool for CAD under general medical conditions.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Redes Neurais de Computação
7.
Comput Biol Med ; 113: 103396, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31446319

RESUMO

BACKGROUND: The significant association of myocardial ischemia with elevated QT interval variability (QTV) has been reported in myocardial infarction (MI) patients. However, the influence of the time course of MI on QTV has not been investigated systematically. METHOD: Short-term QT and RR interval time series were constructed from the 5 min electrocardiograms of 49 coronary patients without MI and 26 patients with old MI (OMI). The QTV, heart rate variability (HRV), and QT-RR coupling of the two groups were analyzed using various time series analysis tools in the time- and frequency-domains, as well as nonlinear dynamics. RESULTS: Nearly all of the tested QTV indices for coronary patients with OMI were higher than those for patients without MI. However, no significant differences were found between the two groups in any of the variables employed to assess the HRV and QT-RR coupling. All of the markers that showed statistical significances in univariate analyses still possessed the capabilities of distinguishing between the two groups even after adjusting for studied baseline characteristics, including the coronary atherosclerotic burden. CONCLUSIONS: The results suggested that the QTV increased in coronary patients with OMI compared to those without MI, which might reflect the influence of post-MI remodeling on the beat-to-beat temporal variability of ventricular repolarization. The non-significant differences in the HRV and QT-RR couplings could indicate that there were no differences in the modulation of the autonomic nervous system and interaction of QT with the RR intervals between the two groups.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Eletrocardiografia , Modelos Cardiovasculares , Infarto do Miocárdio/fisiopatologia , Processamento de Sinais Assistido por Computador , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade