Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Oxf Med Case Reports ; 2022(1): omab138, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35083053

RESUMO

Non-bacterial thrombotic endocarditis (NBTE) is a rare condition characterized by non-infectious vegetations affecting the cardiac valves. Although systemic thromboembolism is a commonly associated condition, antiphospholipid syndrome is less common. Nevertheless, treatment generally involves long-term anticoagulation. We report a case of a patient with previously undiagnosed NBTE who suffered systemic thromboembolic events despite pre-existing treatment with a direct-acting oral anticoagulant.

2.
J Surg Case Rep ; 2021(10): rjab438, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34631009

RESUMO

Infective endocarditis is an important cause of morbidity and mortality, which classically presents with fevers and nonspecific symptoms. Afebrile infective endocarditis with negative blood cultures makes diagnosis more challenging and delays in treatment can occur increasing the likelihood of complications. The presence of prosthetic heart valves places patients at an increased risk of infective endocarditis and the case described below highlights the importance of considering this diagnosis even if classic clinical features such as fever and raised inflammatory markers are not present, as well as discussing an unusual complication of infective endocarditis; coronary artery embolism leading to myocardial infarction.

4.
ASAIO J ; 66(2): 132-138, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-30913099

RESUMO

At fixed speed, the spontaneous increase in pump flow accompanying exercise in patients with continuous flow left ventricular assist devices (cfLVADs) is slight in comparison to normal physiologic response, limiting exercise capacity. We systematically exercised 14 patients implanted with an isolated HeartWare HVAD undergoing routine right heart catheterization at baseline and at maximal safe pump speed. In addition to hemodynamics, mixed venous oxygen saturation (SvO2), echocardiography and noninvasive mean arterial pressure, and heart rate were measured. Significantly greater pump flows were achieved with maximum pump speed compared with baseline speed at rest (mean ± standard deviation [SD]: 5.0 ± 0.7 vs. 4.6 ± 0.8 L/min) and peak exercise (6.7 ± 1.0 vs. 5.9 ± 0.9 L/min, p = 0.001). Pulmonary capillary wedge pressure was significantly reduced with maximum pump speed compared to baseline pump speed at rest (10 ± 4 vs. 15 ± 5 mmHg, p < 0.001) and peak exercise (27 ± 8 vs. 30 ± 8 mmHg, p = 0.002). Mixed venous oxygen saturation decreased with exercise (p < 0.001) but was unaffected by changes in pump speed. In summary, although higher pump speeds synergistically augment the increase in pump flow associated with exercise and blunt the exercise-induced rise in left heart filling pressures, elevated filling pressures and markedly diminished SvO2 persist at maximal safe pump speed, suggesting that physiologic flow increases are not met by isolated cfLVADs in the supported failing heart.


Assuntos
Exercício Físico/fisiologia , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar , Hemodinâmica/fisiologia , Feminino , Humanos , Masculino
5.
Circ Genom Precis Med ; 11(8): e002135, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354343

RESUMO

Background Truncating variants in the TTN gene ( TTNtv) are common in patients with dilated cardiomyopathy (DCM) but also occur in the general population. Whether TTNtv are sufficient to cause DCM or require a second hit for DCM manifestation is an important clinical issue. Methods We generated a zebrafish model of an A-band TTNtv identified in 2 human DCM families in which early-onset disease appeared to be precipitated by ventricular volume overload. Cardiac phenotypes were serially assessed from 0 to 12 months using video microscopy, high-frequency echocardiography, and histopathologic analysis. The effects of sustained hemodynamic stress resulting from an anemia-induced hyperdynamic state were also evaluated. Results Homozygous ttna mutants had severe cardiac dysmorphogenesis and premature death, whereas heterozygous mutants ( ttnatv/+) survived into adulthood and spontaneously developed DCM. Six-month-old ttnatv/+ fish had reduced baseline ventricular systolic function and failed to mount a hypercontractile response when challenged by hemodynamic stress. Pulsed wave and tissue Doppler analysis also revealed unsuspected ventricular diastolic dysfunction in ttnatv/+ fish with prolonged isovolumic relaxation and increased diastolic passive stiffness in the absence of myocardial fibrosis. These defects reduced diastolic reserve under stress conditions and resulted in disproportionately greater atrial dilation than observed in wild-type fish. Conclusions Heterozygosity for A-band titin truncation is sufficient to cause DCM in adult zebrafish. Abnormalities of systolic and diastolic reserve in titin-truncated fish reduce stress tolerance and may contribute to a substrate for atrial arrhythmogenesis. These data suggest that hemodynamic stress may be an important modifiable risk factor in human TTNtv-related DCM.


Assuntos
Cardiomiopatia Dilatada/genética , Conectina/genética , Hemodinâmica/genética , Estresse Fisiológico/genética , Adaptação Biológica/genética , Adolescente , Adulto , Idoso , Animais , Animais Geneticamente Modificados , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/fisiopatologia , Embrião não Mamífero , Feminino , Estudos de Associação Genética , Coração/embriologia , Coração/crescimento & desenvolvimento , Cardiopatias Congênitas/genética , Cardiopatias Congênitas/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem , Sarcômeros/patologia , Deleção de Sequência , Volume Sistólico/genética , Adulto Jovem , Peixe-Zebra
6.
Circ J ; 82(3): 620-628, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29415914

RESUMO

Echocardiography is an invaluable tool for characterizing cardiac structure and function in vivo. Technological advances in high-frequency ultrasound over the past 3 decades have increased spatial and temporal resolution, and facilitated many important clinical and basic science discoveries. Successful reverse translation of established echocardiographic techniques, including M-mode, B-mode, color Doppler, pulsed-wave Doppler, tissue Doppler and, most recently, myocardial deformation imaging, from clinical cardiology into the basic science laboratory has enabled researchers to achieve a deeper understanding of myocardial phenotypes in health and disease. With high-frequency echocardiography, detailed evaluation of ventricular systolic function in a range of small animal models is now possible. Furthermore, improvements in frame rate and the advent of diastolic strain rate imaging, when coupled with the use of select pulsed-wave Doppler parameters, such as isovolumic relaxation time and E wave deceleration, have enabled nuanced interpretation of ventricular diastolic function. Comparing pulsed-wave Doppler indices of atrioventricular inflow during early and late diastole with parameters that describe the simultaneous myocardial deformation (e.g., tissue Doppler é and á, global longitudinal strain rate and global longitudinal velocity) may yield additional insights related to myocardial compliance. This review will provide a historical perspective of the development of high-frequency echocardiography and consider how ongoing innovation will help future-proof this important imaging modality for 21st century translational research.


Assuntos
Ecocardiografia/tendências , Animais , Diagnóstico por Imagem/métodos , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Ecocardiografia Doppler de Pulso , Coração/diagnóstico por imagem , Humanos , Camundongos , Pesquisa/instrumentação , Pesquisa/tendências , Peixe-Zebra
7.
Dis Model Mech ; 10(1): 63-76, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28067629

RESUMO

The zebrafish (Danio rerio) is an increasingly popular model organism in cardiovascular research. Major insights into cardiac developmental processes have been gained by studies of embryonic zebrafish. However, the utility of zebrafish for modeling adult-onset heart disease has been limited by a lack of robust methods for in vivo evaluation of cardiac function. We established a physiological protocol for underwater zebrafish echocardiography using high frequency ultrasound, and evaluated its reliability in detecting altered cardiac function in two disease models. Serial assessment of cardiac function was performed in wild-type zebrafish aged 3 to 12 months and the effects of anesthetic agents, age, sex and background strain were evaluated. There was a varying extent of bradycardia and ventricular contractile impairment with different anesthetic drugs and doses, with tricaine 0.75 mmol l-1 having a relatively more favorable profile. When compared with males, female fish were larger and had more measurement variability. Although age-related increments in ventricular chamber size were greater in females than males, there were no sex differences when data were normalized to body size. Systolic ventricular function was similar in both sexes at all time points, but differences in diastolic function were evident from 6 months onwards. Wild-type fish of both sexes showed a reliance on atrial contraction for ventricular diastolic filling. Echocardiographic evaluation of adult zebrafish with diphtheria toxin-induced myocarditis or anemia-induced volume overload accurately identified ventricular dilation and altered contraction, with suites of B-mode, ventricular strain, pulsed-wave Doppler and tissue Doppler indices showing concordant changes indicative of myocardial hypocontractility or hypercontractility, respectively. Repeatability, intra-observer and inter-observer correlations for echocardiographic measurements were high. We demonstrate that high frequency echocardiography allows reliable in vivo cardiac assessment in adult zebrafish and make recommendations for optimizing data acquisition and analysis. This enabling technology reveals new insights into zebrafish cardiac physiology and provides an imaging platform for zebrafish-based translational research.


Assuntos
Envelhecimento/fisiologia , Ecocardiografia/normas , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Testes de Função Cardíaca/normas , Peixe-Zebra/fisiologia , Pontos de Referência Anatômicos , Anemia/patologia , Anestesia , Animais , Tamanho Corporal , Toxina Diftérica , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Masculino , Contração Miocárdica , Miocardite/diagnóstico por imagem , Miocardite/patologia , Miocardite/fisiopatologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Tamanho do Órgão , Padrões de Referência , Reprodutibilidade dos Testes , Função Ventricular Esquerda
10.
Heart Lung Circ ; 25(7): 668-75, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26906283

RESUMO

BACKGROUND: Technological advancements in newer-generation catheterisation laboratories may reduce patient and occupational radiation exposure. METHODS: We compared fluoroscopy time and dose-area product (DAP) between a Philips Allura X-PER FD20 and Siemens Artis Zeego Hybrid systems for 47 single-vessel percutaneous coronary interventions (PCI) and 35 transcatheter aortic valve implantations (21 Corevalve, 14 Edwards Sapien TAVI) using the FD20, versus 30 PCI and 28 TAVI (15 Corevalve, 13 Sapien) with the Zeego over a 24-month period. RESULTS: Multivariate analysis revealed that, adjusting for patient weight and fluoroscopy time, DAP (median, interquartile range) was 26% lower for PCI with the Zeego than the FD20 [55.6 (27.0-91.5) vs 77.6 (51.2-129.1) Gy.cm(2), P=0.03)] and using tomographic imaging with the Zeego did not increase DAP for TAVI procedures [98.1 (65.9-136.6) vs 112.4 (64.9-156.2) Gy.cm(2) (P=NS). Although fluoroscopy times were longer for TAVI procedures than PCI with both systems (23.5-24.4 vs 7.3-9.2mins, p<0.0001), there was a significant difference in DAP between PCI and combined TAVI with the Zeego (55.6 vs 112.4Gy.cm(2), P<0.006) but not with the FD20 (77.6 vs 98.1Gy.cm(2), P=NS). CONCLUSION: Specific dose-reducing features of the new-generation system reduced DAP more for PCI than TAVI, as valve replacement procedures use additional cine-acquisition not necessary for PCI.


Assuntos
Intervenção Coronária Percutânea/métodos , Doses de Radiação , Tomografia por Raios X/instrumentação , Tomografia por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Feminino , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
Ann Thorac Surg ; 99(4): 1434-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25841830

RESUMO

Transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valve disease is associated with higher rates of paravalvular aortic regurgitation, which may require subsequent surgical correction. We report a case of successful late surgical CoreValve explantation 1,389 days after TAVI in a patient with bicuspid aortic valve stenosis and McArdle's disease who developed severe paravalvular aortic regurgitation. We confirm that neoendothelialization and incorporation of the nitinol cage into the aortic wall had occurred at nearly 4 years postimplantation, although explantation with careful endarterectomy could still be performed without requiring simultaneous aortic root replacement.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Remoção de Dispositivo/métodos , Ecocardiografia Transesofagiana/métodos , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
14.
Transplantation ; 99(4): 731-45, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25769066

RESUMO

BACKGROUND: Whether abnormal myocardial perfusion scintigraphy (MPS), dobutamine stress echocardiography (DSE) or coronary angiography, performed during preoperative evaluation for potential kidney transplant recipients, predicts future cardiovascular morbidity is unclear. We assessed test performance for predicting all-cause mortality, cardiovascular mortality and major adverse cardiac events (MACE). METHODS: We searched MEDLINE and EMBASE (to February 2014), appraised studies, and calculated risk differences and relative risk ratios (RRR) with 95% confidence intervals (95% CI) using random effects meta-analysis. RESULTS: Fifty-two studies (7401 participants) contributed data to the meta-analysis. Among the different tests, similar numbers of patients experienced MACE after an abnormal test result compared with a normal result (risk difference: MPS 20 per 100 patients tested [95% CI, 0.11-0.29], DSE 24 [95% CI, 0.10-0.38], and coronary angiography 20 [95% CI, 0.08-0.32; P = 0.91]). Although there was some evidence that coronary angiography was better at predicting all-cause mortality than MPS (RRR, 0.69; 95% CI, 0.49-0.96; P = 0.03) and DSE (RRR, 0.72; 95% CI, 0.50-1.02; P = 0.06), noninvasive tests were as good as coronary angiography at predicting cardiovascular mortality (RRR, MPS, 0.89; 95% CI, 0.38-2.10; P = 0.78; DSE, 1.09; 95% CI, 0.12-10.05; P = 0.93), and MACE (RRR: MPS, 1.09; 95% CI, 0.64-1.86; P = 0.74; DSE, 1.56; 95% CI, 0.71-3.45; P = 0.25). CONCLUSIONS: Noninvasive tests are as good as coronary angiography at predicting future adverse cardiovascular events in advanced chronic kidney disease. However, a substantial number of people with negative test results go on to experience adverse cardiac events.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Cardiopatias/diagnóstico , Transplante de Rim , Insuficiência Renal Crônica/cirurgia , Transplantados , Distribuição de Qui-Quadrado , Cardiopatias/complicações , Cardiopatias/mortalidade , Humanos , Transplante de Rim/efeitos adversos , Transplante de Rim/mortalidade , Razão de Chances , Valor Preditivo dos Testes , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Heart Lung Circ ; 23(11): 1075-83, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24973863

RESUMO

BACKGROUND: With the increased application of structural heart intervention techniques, there is concern over increasing radiation dose, especially during lengthy procedures. METHODS: We compared data from 91 consecutive single-vessel percutaneous coronary interventions, 69 patent foramen ovale closures, 25 atrial septal defect closures, 49 percutaneous transluminal mitral valvuloplasties, 57 balloon aortic valvuloplasties, 53 trans-catheter aortic valve implantations (TAVI), 21 left atrial appendage occlusions and 7 MitraClip procedures. RESULTS: The following fluoroscopy times and dose-area product (median, interquartile range) were recorded: patent foramen ovale closure (7.8, 5.3-10.9 minutes; 16.9, 7.5-30.6 Gycm(2)), atrial septal defect closure (10.1, 7.3-13 minutes; 15.5, 11.6-30.5 Gycm(2)), percutaneous transluminal mitral valvuloplasty (14.3, 11.4-24.2 minutes; 37.4, 19.8-87.0 Gycm(2)), balloon aortic valvuloplasty (8.4, 5.2-13.2 minutes; 19.8, 10.2-30.0 Gycm(2)), Edwards Sapien TAVI (24.0, 19.3-34.4 minutes; 86.4, 64.0-111.4 Gycm(2)), Medtronic CoreValve TAVI (19.4, 15.0-26.0 minutes; 101.9, 52.6-143.2 Gycm(2)), left atrial appendage occlusion (18.5, 15.7-29.1 minutes; 84.1, 36.4-140.0 Gycm(2)), Mitraclip procedures (37.2, 14.2-59.9 minutes; 89.1, 26.2-118.7 Gycm(2)), coronary angiography and single vessel percutaneous coronary intervention (6.6, 5.1-11.0 minutes; 62.5, 37.0-95.8 Gycm(2)). CONCLUSION: For structural heart interventions, dose-area product was not significantly greater than for coronary angiography with single-vessel percutaneous coronary artery intervention. This should be reassuring to patients and staff attending prolonged structural heart interventions.


Assuntos
Valvuloplastia com Balão , Angiografia Coronária , Cardiopatias , Intervenção Coronária Percutânea , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Idoso , Cardiopatias/diagnóstico por imagem , Cardiopatias/cirurgia , História Antiga , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA