Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 33(11): 7595-7608, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37231068

RESUMO

OBJECTIVES: Differences in clinical adverse outcomes (CAO) based on different intestinal stricturing definitions in Crohn's disease (CD) are poorly documented. This study aims to compare CAO between radiological strictures (RS) and endoscopic strictures (ES) in ileal CD and explore the significance of upstream dilatation in RS. METHODS: This retrospective double-center study included 199 patients (derivation cohort, n = 157; validation cohort, n = 42) with bowel strictures who simultaneously underwent endoscopic and radiologic examinations. RS was defined as a luminal narrowing with wall thickening relative to the normal gut on cross-sectional imaging (group 1 (G1)), which further divided into G1a (without upstream dilatation) and G1b (with upstream dilatation). ES was defined as an endoscopic non-passable stricture (group 2 (G2)). Strictures met the definitions of RS (with or without upstream dilatation) and ES were categorized as group 3 (G3). CAO referred to stricture-related surgery or penetrating disease. RESULTS: In the derivation cohort, G1b (93.3%) had the highest CAO occurrence rate, followed by G3 (32.6%), G1a (3.2%), and G2 (0%) (p < 0.0001); the same order was found in the validation cohort. The CAO-free survival time was significantly different among the four groups (p < 0.0001). Upstream dilatation (hazard ratio, 1.126) was a risk factor for predicting CAO in RS. Furthermore, when upstream dilatation was added to diagnose RS, 17.6% of high-risk strictures were neglected. CONCLUSIONS: CAO differs significantly between RS and ES, and clinicians should pay more attention to strictures in G1b and G3. Upstream dilatation has an important impact on the clinical outcome of RS but may not be an essential factor for RS diagnosis. CLINICAL RELEVANCE STATEMENT: This study explored the definition of intestinal stricture with the greatest significance for the clinical diagnosis and prognosis of patients with CD, and consequently provided effective auxiliary information for clinicians to formulate strategies for the treatment of CD intestinal strictures. KEY POINTS: • The retrospective double-center study showed that clinical adverse outcome is different between radiological strictures and endoscopic strictures in CD. • Upstream dilatation has an important impact on the clinical outcome of radiological strictures but may not be an essential factor for diagnosis of radiological strictures. • Radiological stricture with upstream dilatation and simultaneous radiological and endoscopic stricture were at increased risk for clinical adverse outcomes; thus, closer monitoring should be considered.


Assuntos
Doença de Crohn , Obstrução Intestinal , Humanos , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Constrição Patológica/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Endoscopia/métodos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Dilatação/métodos , Endoscopia Gastrointestinal/métodos
2.
Eur J Radiol ; 162: 110766, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36924538

RESUMO

BACKGROUND: More than half of patients with Crohn's disease (CD) require at least one surgery for symptom management; however, approximately half of the patients may experience postoperative anastomotic recurrence (PAR). OBJECTIVES: This study aims to develop and validate a preoperative computed tomography enterography (CTE)-based radiomics signature to predict early PAR in CD. DESIGN: A total of 186 patients with CD (training cohort, n = 134; test cohort, n = 52) who underwent preoperative CTE and surgery between January 2014 and June 2020 were included in this retrospective multi-centre study. METHODS: 106 radiomic features were initially extracted from intestinal lesions and peri-intestinal mesenteric fat, respectively; significant radiomic features were selected from them and then used to develop intestinal or mesenteric radiomics signatures, using the least absolute shrinkage and selection operator and a Cox regression model. A radiomics-based nomogram incorporating these signatures with clinical-radiological factors was created for comparison with a model based on clinical-radiological features alone. RESULTS: 68 of 134 patients in training cohort and 16 of 52 patients in test cohort suffered from PAR. The intestinal radiomic signature (hazard ratio [HR]: 2.17; 95% confidence interval [CI]: 1.32-3.58; P = 0.002) and mesenteric radiomic signature (HR: 2.19; 95% CI: 1.14-4.19; P = 0.018) were independent risk factors for PAR in the training cohort as per a multivariate analysis. The radiomics-based nomogram (C-index: 0.710; 95% CI: 0.672-0.748) yielded superior predictive performance than the clinical-radiological model (C-index, 0.607; 95% CI: 0.582-0.632) in the test cohort. Decision curve analysis demonstrated that the radiomics-based nomogram outperformed the clinical-radiological model in terms of clinical usefulness. CONCLUSIONS: Preoperative mesenteric and intestinal CTE radiomics signatures are potential non-invasive predictors of PAR in postoperative patients with CD.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Tomografia Computadorizada por Raios X/métodos , Nomogramas , Radiografia , Estudos Retrospectivos
3.
United European Gastroenterol J ; 10(10): 1179-1193, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36461914

RESUMO

Cross-sectional imaging-ultrasonography, computed tomography enterography, and magnetic resonance enterography-is a routine and indispensable tool for patients with Crohn's disease (CD) that helps to detect or monitor disease characteristics before, during, and after CD treatment. New emerging radiological technologies may have further clinical applications in the management of CD. In this review article, we focus on the latest developments in cross-sectional imaging in CD research, including its role in intra- and extra-luminal lesion detection, intestinal inflammation and fibrosis grading, therapeutic response assessment and outcome prediction, postoperative recurrence detection and prediction, and the gut-brain axis.


Assuntos
Doença de Crohn , Doenças Inflamatórias Intestinais , Humanos , Intestino Delgado/patologia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Doenças Inflamatórias Intestinais/patologia , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
4.
Ultrasound Med Biol ; 45(3): 732-740, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30558830

RESUMO

Chronic fluid over-hydration is common in dialysis patients. It is associated with mortality and cardiovascular events. Optimal methods for adjusting fluid volume status and ideal dry weight remain uncertain. The purpose of this study was to evaluate the usefulness of ultrasound in quantifying body water. In 35 hemodialysis patients, we performed ultrasound of the chest, pre-tibial skin tissue thickness (TT), heart and inferior vena cava (IVC) before and after dialysis. We compared B-line scores of lungs, IVC diameters and cardiac functions in pre-dialysis and post-dialysis groups. We then estimated the correlations between ultrasound parameters and ultrafiltration volumes. Ultrafiltration parameters were adjusted prospectively for subsequent dialysis. As a result, both extravascular and intravascular water decreased during ultrafiltration. The median numbers of B-line scores (10 [0-42] vs. 4 [0-30]; p < 0.001); mitral valve blood flow velocities E (0.83 ± 0.23 m/s vs. 0.70 ± 0.20 m/s; p < 0.001), A (0.93 ± 0.28 vs. 0.89 ± 0.23 m/s; p < 0.001) and E/e' (12.47 ± 4.92 vs. 10.37 ± 4.0; p < 0.001); IVC diameters at end-expiration (17.51 ± 3.33 mm vs. 14.26 ± 3.45 mm; p < 0.001); and right pre-tibial TT (2.86 ± 1.36 mm vs. 2.43 ± 1.24 mm; p < 0.001) decreased during dialysis. Ultrafiltration volume was most associated with B-line score (adjusting for age and sex) (ß = -3.340; p = 0.003). In addition, the B-line score after dialysis was significantly associated with left ventricular ejection fraction (r = -0.393; p = 0.019) and TT (r = -0.447; p = 0.007). Ultrafiltration volume was prospectively increased then if the B-line score was >6 in the previous dialysis. All patients tolerated the protocol well without any symptoms. Ultrafiltration volume was most associated with lung water, reflected by variation in B-line score. It was not associated with cardiac function, IVC diameter, IVC collapse rate or TT. Lung ultrasound is a useful imaging tool for dialysis patients.


Assuntos
Água Corporal/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Diálise Renal , Ultrassonografia/métodos , Equilíbrio Hidroeletrolítico/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrafiltração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA