Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol ; 129: 109140, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32593077

RESUMO

PURPOSE: Conventional mammography is a decisive tool in detecting breast cancer. Continuous efforts are undertaken in order to further improve the image quality as well as to reduce the applied doses. The purpose of our study was to compare diagnostic image quality of dose reduced computed mammography with a new needle-based detector system to full dose powder imaging plates. METHODS: We retrospectively compared 360 randomly chosen mammographies performed on a GE Senographe DMR running the Agfa DX-M needle-based imaging plate system (NIP) with their preliminary examinations which were acquired at standard dose with the same GE mammography device and an Agfa CR85-X powdered storage phosphor imaging plate system (PIP). NIP-based mammographies were about 29.8 % dose-reduced. The preliminary examinations had to be performed not earlier than 2 years before the recent investigations. Exclusion criteria were changes in ACR level and appearance of the scored targets and not optimally positioned and exposed mammographies. The images were blinded and read separately twice by 2 mammography experts according to a 3-point score on diagnostic image quality and the visualization of parenchyma, cysts, fibroadenomas, physiologic lymph nodes, solitary microcalcifications and macrocalcifications. RESULTS: Dose reduced NIPs showed a significantly better visualization of parenchyma at ACR II/III and solitary microcalcifications at ACR I-III mammographies (p < 0.001) whereas the difference in scoring macrocalcifications, cysts, fibroadenomas and physiologic lymph nodes was not significant. The reading showed an excellent intra- (r = 0.97/0.94) and interobserver agreement (r = 0.92). CONCLUSION: With computed mammography using the needle-based detector system a significant dose reduction is possible without loss of diagnostic image quality.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ecrans Intensificadores para Raios X
2.
BMC Med Imaging ; 19(1): 3, 2019 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-30612560

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) provide secure intravenous access for the delivery of life-sustaining medications and nutrition. They are commonly used in pediatrics. Confirmation of correct central catheter tip position is crucial. Verification is usually done by a radiograph. The aim of this study is to evaluate the ability of Fractional Multiscale image Processing (FMP) to detect PICC tips on the digital chest radiographs of neonates. METHODS: A total of 94 radiographs of 47 patients were included in the study. 29 patients were male, 18 were female. The mean age of all examined children was 9.2 days (range 0-99 days). In total, six readers (two radiologists, two residents in radiology, one last year medical student, one neonatologist) evaluated 94 unprocessed and catheter-enhanced radiographs using a 5-point Likert scale (1 = poor catheter tip visualization, 5 = excellent catheter tip visualization). Additionally, the two radiologists evaluated the diagnostic confidence for chest pathologies using a 5-point Likert scale (1 = poor diagnostic confidence, 5 = excellent diagnostic confidence). Radiographs were evaluated on a dedicated workstation. RESULTS: In all cases, the catheter-enhanced radiograph rated higher than (n = 471), or equal (n = 93) to, the unprocessed radiograph when visualizing catheter tips. 87% of the catheter-enhanced radiographs obtained a rating of 4 or higher, while only 42% of unprocessed radiographs received 4 or more points. Regarding diagnostic confidence for chest pathologies one radiologist rated two catheter-enhanced radiographs higher than the unprocessed radiographs, while all other 186 evaluations rated the catheter-enhanced radiographs equal to (n = 78) or lower than (n = 108) the unprocessed radiographs. Only 60% of the catheter-enhanced radiographs yielded a diagnostic confidence of 4 or higher, while 90% of the unprocessed images received 4 or more points. CONCLUSION: Catheter-enhanced digital chest radiographs demonstrate improved visualization of low contrast PICC tips in neonates compared to unprocessed radiographs. Furthermore, they enable detection of accompanying chest pathologies. However, definitive diagnosis of chest pathologies should be made on unprocessed radiographs.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radiografia Torácica/instrumentação , Cateterismo Periférico , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Radiografia Torácica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA