Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 13990, 2024 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-38886462

RESUMO

In this retrospective case series on neovascular age-related macular degeneration (nAMD), we aimed to improve Choroidal Neovascularization (CNV) visualization in Optical Coherence Tomography Angiography (OCTA) scans by addressing segmentation errors. Out of 198 eyes, 73 OCTA scans required manual segmentation correction. We compared uncorrected scans to those with minimal (2 corrections), moderate (10 corrections), and detailed (50 corrections) efforts targeting falsely segmented Bruch's Membrane (BM). Results showed that 55% of corrected OCTAs exhibited improved quality after manual correction. Notably, minimal correction (2 scans) already led to significant improvements, with additional corrections (10 or 50) not further enhancing expert grading. Reduced background noise and improved CNV identification were observed, with the most substantial improvement after two corrections compared to baseline uncorrected images. In conclusion, our approach of correcting segmentation errors effectively enhances image quality in OCTA scans of nAMD. This study demonstrates the efficacy of the method, with 55% of resegmented OCTA images exhibiting enhanced quality, leading to a notable increase in the proportion of high-quality images from 63 to 83%.


Assuntos
Neovascularização de Coroide , Degeneração Macular , Tomografia de Coerência Óptica , Humanos , Neovascularização de Coroide/diagnóstico por imagem , Neovascularização de Coroide/patologia , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Degeneração Macular/diagnóstico por imagem , Degeneração Macular/patologia , Degeneração Macular/complicações , Idoso de 80 Anos ou mais , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Angiofluoresceinografia/métodos
2.
Retina ; 44(3): 465-474, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37988102

RESUMO

PURPOSE: The authors hypothesize that optical coherence tomography angiography (OCTA)-visualized vascular morphology may be a predictor of choroidal neovascularization status in age-related macular degeneration (AMD). The authors thus evaluated the use of artificial intelligence (AI) to predict different stages of AMD disease based on OCTA en face 2D projections scans. METHODS: Retrospective cross-sectional study based on collected 2D OCTA data from 310 high-resolution scans. Based on OCT B-scan fluid and clinical status, OCTA was classified as normal, dry AMD, wet AMD active, and wet AMD in remission with no signs of activity. Two human experts graded the same test set, and a consensus grading between two experts was used for the prediction of four categories. RESULTS: The AI can achieve 80.36% accuracy on a four-category grading task with 2D OCTA projections. The sensitivity of prediction by AI was 0.7857 (active), 0.7142 (remission), 0.9286 (dry AMD), and 0.9286 (normal) and the specificity was 0.9524, 0.9524, 0.9286, and 0.9524, respectively. The sensitivity of prediction by human experts was 0.4286 active choroidal neovascularization, 0.2143 remission, 0.8571 dry AMD, and 0.8571 normal with specificity of 0.7619, 0.9286, 0.7857, and 0.9762, respectively. The overall AI classification prediction was significantly better than the human (odds ratio = 1.95, P = 0.0021). CONCLUSION: These data show that choroidal neovascularization morphology can be used to predict disease activity by AI; longitudinal studies are needed to better understand the evolution of choroidal neovascularization and features that predict reactivation. Future studies will be able to evaluate the additional predicative value of OCTA on top of other imaging characteristics (i.e., fluid location on OCT B scans) to help predict response to treatment.


Assuntos
Neovascularização de Coroide , Atrofia Geográfica , Degeneração Macular Exsudativa , Humanos , Inteligência Artificial , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Estudos Transversais , Angiofluoresceinografia/métodos , Neovascularização de Coroide/diagnóstico , Neovascularização de Coroide/tratamento farmacológico , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/tratamento farmacológico
3.
Sci Rep ; 13(1): 5100, 2023 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-36991025

RESUMO

This cross-sectional study aimed to investigate the hypothesis that permanent capillary damage may underlie the long-term COVID-19 sequela by quantifying the retinal vessel integrity. Participants were divided into three subgroups; Normal controls who had not been affected by COVID-19, mild COVID-19 cases who received out-patient care, and severe COVID-19 cases requiring intensive care unit (ICU) admission and respiratory support. Patients with systemic conditions that may affect the retinal vasculature before the diagnosis of COVID-19 infection were excluded. Participants underwent comprehensive ophthalmologic examination and retinal imaging obtained from Spectral-Domain Optical Coherence Tomography (SD-OCT), and vessel density using OCT Angiography. Sixty-one eyes from 31 individuals were studied. Retinal volume was significantly decreased in the outer 3 mm of the macula in the severe COVID-19 group (p = 0.02). Total retinal vessel density was significantly lower in the severe COVID-19 group compared to the normal and mild COVID-19 groups (p = 0.004 and 0.0057, respectively). The intermediate and deep capillary plexuses in the severe COVID-19 group were significantly lower compared to other groups (p < 0.05). Retinal tissue and microvascular loss may be a biomarker of COVID-19 severity. Further monitoring of the retina in COVID-19-recovered patients may help further understand the COVID-19 sequela.


Assuntos
COVID-19 , Humanos , Angiofluoresceinografia/métodos , Estudos Transversais , Retina/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
4.
Ophthalmic Surg Lasers Imaging Retina ; 54(2): 108-113, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36780638

RESUMO

BACKGROUND AND OBJECTIVE: The purpose of this study was to evaluate the accuracy and the time to find a lesion, taken in different platforms, color fundus photographs and infrared scanning laser ophthalmoscope images, using the traditional side-by-side (SBS) colocalization technique to an artificial intelligence (AI)-assisted technique. PATIENTS AND METHODS: Fifty-three pathological lesions were studied in 11 eyes. Images were aligned using SBS and AI overlaid methods. The location of each color fundus lesion on the corresponding infrared scanning laser ophthalmoscope image was analyzed twice, one time for each method, on different days, for two specialists, in random order. The outcomes for each method were measured and recorded by an independent observer. RESULTS: The colocalization AI method was superior to the conventional in accuracy and time (P < .001), with a mean time to colocalize 37% faster. The error rate using AI was 0% compared with 18% in SBS measurements. CONCLUSIONS: AI permitted a more accurate and faster colocalization of pathologic lesions than the conventional method. [Ophthalmic Surg Lasers Imaging Retina 2023;54:108-113.].


Assuntos
Inteligência Artificial , Oftalmoscópios , Humanos , Fundo de Olho , Exame Físico
5.
Nanomedicine (Lond) ; 17(27): 2089-2108, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36748946

RESUMO

Aim: To evaluate an intravitreally injected nanoparticle platform designed to deliver VEGF-A siRNA to inhibit retinal neovascular leakage as a new treatment for proliferative diabetic retinopathy and diabetic macular edema. Materials & methods: Fusogenic lipid-coated porous silicon nanoparticles loaded with VEGF-A siRNA, and pendant neovascular integrin-homing iRGD, were evaluated for efficacy by intravitreal injection in a rabbit model of retinal neovascularization. Results: For 12 weeks post-treatment, a reduction in vascular leakage was observed for treated diseased eyes versus control eyes (p = 0.0137), with a corresponding reduction in vitreous VEGF-A. Conclusion: Fusogenic lipid-coated porous silicon nanoparticles siRNA delivery provides persistent knockdown of VEGF-A and reduced leakage in a rabbit model of retinal neovascularization as a potential new intraocular therapeutic.


Assuntos
Retinopatia Diabética , Edema Macular , Nanopartículas , Neovascularização Retiniana , Animais , Coelhos , Neovascularização Retiniana/tratamento farmacológico , Fator A de Crescimento do Endotélio Vascular/genética , Fator A de Crescimento do Endotélio Vascular/uso terapêutico , Silício , Retinopatia Diabética/tratamento farmacológico , Retinopatia Diabética/genética , RNA Interferente Pequeno/genética , RNA Interferente Pequeno/uso terapêutico , Porosidade , Edema Macular/tratamento farmacológico , Lipídeos/uso terapêutico , Injeções Intravítreas
6.
Proc Int Conf Image Proc ; 2021: 126-130, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35950046

RESUMO

Optical Coherence Tomography (OCT) is a powerful technique for non-invasive 3D imaging of biological tissues at high resolution that has revolutionized retinal imaging. A major challenge in OCT imaging is the motion artifacts introduced by involuntary eye movements. In this paper, we propose a convolutional neural network that learns to correct axial motion in OCT based on a single volumetric scan. The proposed method is able to correct large motion, while preserving the overall curvature of the retina. The experimental results show significant improvements in visual quality as well as overall error compared to the conventional methods in both normal and disease cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA