Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Clin Microbiol Infect Dis ; 42(4): 461-470, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36810725

RESUMO

Identification of Salmonella serovars is performed by conventional seroagglutination or sequencing. These methods are labor-intensive and require technical experience. An easy-to-perform assay allowing the timely identification of the most common non-typhoidal serovars (NTS) is needed. In this study, a molecular assay based on loop-mediated isothermal amplification (LAMP) targeting specific gene sequences of Salmonella Enteritidis, S. Typhimurium, S. Infantis, S. Derby, and S. Choleraesuis has been developed for rapid serovar identification from cultured colonies. A total of 318 Salmonella strains and 25 isolates of other Enterobacterales species that served as negative controls were analyzed. All S. Enteritidis (n = 40), S. Infantis (n = 27), and S. Choleraesuis (n = 11) strains were correctly identified. Seven out of 104 S. Typhimurium and 10 out of 38 S. Derby strains missed a positive signal. Cross-reactions of the gene targets were only rarely observed and restricted to the S. Typhimurium primer set (5 false-positives). Sensitivity and specificity of the assay compared to seroagglutination were as follows: 100% and 100% for S. Enteritidis, 93.3% and 97.7% for S. Typhimurium, 100% and 100% for S. Infantis, 73.7% and 100% for S. Derby, and 100% and 100% for S. Choleraesuis, respectively. With results available in just a few minutes of hands-on time and a test run time of 20 min, the LAMP assay developed here may be a useful tool for the rapid identification of common Salmonella NTS in daily routine diagnostics.


Assuntos
Testes de Diagnóstico Rápido , Febre Tifoide , Humanos , Sorogrupo , Técnicas de Amplificação de Ácido Nucleico , Salmonella enteritidis
2.
Infection ; 51(4): 1141-1145, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36641506

RESUMO

PURPOSE: To analyze sensitivity and specificity of the rapid point-of-care (POC) eazyplex testing platform for bacterial sexually transmitted infections (STI) among men who have sex with men (MSM). METHODS: 272 anal, urethral, and pharyngeal swabs collected from 153 MSM were tested by both the eazyplex platform and an in-house PCR or culture in the university microbiology reference laboratory. RESULTS: Compared to the reference diagnostic method, the overall sensitivity/specificity of eazyplex was 88%/98% for N. gonorrhoeae, 82%/100% for C. trachomatis, 70%/ > 99% for U. urealyticum, and 85%/98% for M. hominis, respectively. Sensitivity for N. gonorrhoeae and U. urealyticum in urethral samples was 100%. CONCLUSION: With good to very good sensitivity depending on the sampling site and pathogen as well as very good specificity overall the eazyplex platform is a useful rapid diagnostic method for POC bacterial STI-testing especially for N. gonorrhoeae and C. trachomatis, allowing for almost immediate treatment initiation.


Assuntos
Infecções por Chlamydia , Gonorreia , Minorias Sexuais e de Gênero , Masculino , Humanos , Homossexualidade Masculina , Infecções por Chlamydia/diagnóstico , Neisseria gonorrhoeae/genética , Chlamydia trachomatis/genética , Testes Imediatos , Gonorreia/diagnóstico , Gonorreia/microbiologia
3.
Virol J ; 17(1): 160, 2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-33087160

RESUMO

BACKGROUND: Fast, reliable and easy to handle methods are required to facilitate urgently needed point-of-care testing (POCT) in the current coronavirus pandemic. Life-threatening severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has rapidly spread all over the world, infecting more than 33,500,000 people and killing over 1 million of them as of October 2020. Infected individuals without any symptoms might still transfer the virus to others underlining the extraordinary transmissibility of this new coronavirus. In order to identify early infections effectively, treat patients on time and control disease spreading, rapid, accurate and onsite testing methods are urgently required. RESULTS: Here we report the development of a loop-mediated isothermal amplification (LAMP) based method to detect SARS-CoV-2 genes ORF8 and N directly from pharyngeal swab samples. The established reverse transcription LAMP (RT-LAMP) assay detects SARS-CoV-2 directly from pharyngeal swab samples without previous time-consuming and laborious RNA extraction. The assay is sensitive and highly specific for SARS-CoV-2 detection, showing no cross reactivity when tested on 20 other respiratory pathogens. The assay is 12 times faster and 10 times cheaper than routine reverse transcription real-time polymerase chain reaction, depending on the assay used. CONCLUSION: The fast and easy to handle RT-LAMP assay amplifying specifically the genomic regions ORF8 and N of SARS-CoV-2 is ideally suited for POCT at e.g. railway stations, airports or hospitals. Given the current pandemic situation, rapid, cost efficient and onsite methods like the here presented RT-LAMP assay are urgently needed to contain the viral spread.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/virologia , Pneumonia Viral/virologia , Animais , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Chlorocebus aethiops , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Genes Virais , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico/métodos , Pandemias , Pneumonia Viral/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real , Transcrição Reversa , SARS-CoV-2 , Células Vero
4.
Acta Trop ; 190: 293-295, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30528158

RESUMO

Typhoid fever, caused by the bacterium Salmonella enterica subsp. enterica serovar Typhi, is an important cause of blood stream infections in the tropics, for which easy-to-apply molecular diagnostic approaches are desirable. The diagnostic performance of a newly introduced and a previously described loop-mediated isothermal amplification (LAMP) approach using different primer sets on a Genie II Mk2 device for the identification of Salmonella enterica ssp. enterica ser. Typhi was evaluated with well-characterized residual materials from the tropics in a case control-based approach. After in-vitro confirmation of binding characteristics of both LAMP primer sets with culture isolates (n = 112), sensitivity and specificity were 100% for the newly designed new LAMP primer set 1 with incubated blood culture materials, while specificity was reduced to 97.1% for primer set 2. For 170 EDTA blood samples, sensitivity and specificity were 10% and 98.3% for primer set 1 as well as 38.0% and 83.3% for primer set 2, respectively; qPCR from EDTA blood did not score much better with 10% sensitivity and 100% specificity. LAMP using a Genie II Mk2 device is suitable for the identification of Salmonella enterica spp. enterica ser. Typhi from incubated blood culture materials. Sensitivity and specificity were insufficient for diagnosis directly from EDTA blood samples but LAMP showed similar sensitivity as qPCR.


Assuntos
Bacteriemia/sangue , Bacteriemia/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentação , Salmonella typhi/isolamento & purificação , Febre Tifoide/sangue , Febre Tifoide/diagnóstico , Bacteriemia/microbiologia , Hemocultura , Estudos de Casos e Controles , Primers do DNA , Humanos , Técnicas de Amplificação de Ácido Nucleico , Estudo de Prova de Conceito , Reação em Cadeia da Polimerase em Tempo Real , Salmonella typhi/genética , Sensibilidade e Especificidade
5.
Eur J Microbiol Immunol (Bp) ; 8(4): 112-118, 2018 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-30719327

RESUMO

BACKGROUND: The objective of this study was to assess an in-house loop-mediated isothermal amplification (LAMP) platform for malaria parasite detection and identification on species level. METHODS: LAMP primers specific for the human Plasmodium spp., namely, P. falciparum, P. vivax, P. ovale, P. malariae, and P. knowlesi, as well as genus-specific primers, were tested against a composite gold standard comprising microscopy from thick and thin blood films, commercial genus-specific Meridian illumigene Malaria LAMP, in-house real-time polymerase chain reaction (PCR), and commercial fast-track diagnostics (FTD) Malaria differentiation PCR. RESULTS: Of the 523 blood samples analyzed, the composite gold standard indicated 243 Plasmodium-species-DNA-containing samples (46.5%). Sensitivity and specificity of the analyzed genus- and species-specific LAMP primers were 71.0%-100.0% and 90.8%-100.0%, respectively. The influence of parasitemia was best documented for P. falciparum-specific LAMP with sensitivity values of 35.5% (22/62) for microscopically negative samples containing P. falciparum DNA, 50% (19/38) for parasitemia ≤50/µL, 84% (21/25) for parasitemia ≤500/µL, and 100% (92/92) for parasitemia >500/µL. CONCLUSIONS: In our hands, performance characteristics of species-specific in-house LAMP for malaria lack reliability required for diagnostic laboratories. The use of the easy-to-apply technique for surveillance purposes may be considered.

6.
J Clin Microbiol ; 50(9): 3115-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22785190

RESUMO

A commercial multiplex PCR (hyplex SuperBug ID) was tested with a collection of 132 clinical Enterobacteriaceae strains producing different carbapenemases. The sensitivity for the detection of KPC-, VIM-, NDM-, and OXA-48-encoding genes was 100%, whereas two IMP variants were missed.


Assuntos
Proteínas de Bactérias/genética , Técnicas Bacteriológicas/métodos , Enterobacteriaceae/enzimologia , Reação em Cadeia da Polimerase Multiplex/métodos , beta-Lactamases/genética , Humanos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
7.
Drug Test Anal ; 3(10): 645-51, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21928278

RESUMO

The deletion polymorphism of the enzyme UGT2B17 is known to correlate with the level of the testosterone to epitestosterone (T/E) ratio in urine specimen. Due to the importance of the T/E ratio to detect testosterone abuse in doping analysis, a PCR-ELISA system (Genotype® UGT test, AmplexDiagnostics) was established to identify the UGT2B17 phenotype in urine samples. Epidemiological investigations in a set of 674 routine doping controls (in- and out-of-competition) resulted in 22.8% homozygote gene-deleted and 74.5% UGT2B17-positive athletes. The validated test system has shown to be robust and sensitive: in only 18 cases (2.7%) isolation of cell material from urine failed. Following hydrolysis of glucuronidated conjugates, steroids were analyzed as bis-TMS derivatives by gas chromatography-mass spectrometry (GC-MS), for example, testosterone (T) and epitestosterone (E). Additionally, isotope ration mass spectrometry (IRMS) analysis and luteinizing hormone (LH) measurement were applied. Mean T/E ratios significantly correlated with the UGT2B17 phenotype (del: T/E 0.9; pos: 1.7), however the values did not differ as distinctive as reported in previous studies. Additionally, the T/E ratios in the gene-deleted group did not show a normal curve of distribution (median of T/E 0.5). Obviously, beside the UGT2B17 deletion further influences have to be taken into account, for example, polymorphisms or induction of other metabolizing enzymes. Our results indicate that the UGT2B17 polymorphism might be insufficient when utilized solely as a crucial parameter for individual interpretation of T/E in urine. Nevertheless, the detection of the UGT2B17-gene deletion in urine samples would provide additional information important for gathering evidence in analysis of steroids in doping control.


Assuntos
Dopagem Esportivo , Epitestosterona/urina , Testes Genéticos/métodos , Glucuronosiltransferase/genética , Polimorfismo Genético , Detecção do Abuso de Substâncias/métodos , Testosterona/urina , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Deleção de Genes , Genótipo , Humanos , Masculino , Antígenos de Histocompatibilidade Menor , Fenótipo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Clin Microbiol ; 42(7): 3147-52, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15243074

RESUMO

We evaluated the Hyplex BloodScreen PCR-enzyme-linked immunosorbent assay (ELISA) system (BAG, Lich, Germany), a new diagnostic test for the direct identification of gram-negative bacilli and gram-positive cocci from positive blood cultures, with 482 positive BACTEC 9240 blood culture bottles. The test involves amplification of the bacterial DNA by multiplex PCR and subsequent hybridization of the PCR product to specific oligonucleotide probes in an ELISA-based format. The available probes allow the separate detection of Escherichia coli, Pseudomonas aeruginosa, Enterobacter aerogenes, Klebsiella spp., Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis/Enterococcus faecium, Streptococcus pyogenes, and Streptococcus pneumoniae and the staphylococcal mecA gene. The Hyplex BloodScreen test showed an overall sensitivity of 100% for the identification of gram-negative bacilli and 96.6 to 100% for the identification of gram-positive cocci (S. aureus, 100%; S. epidermidis, 97.2%; Enterococcus faecalis/Enterococcus faecium, 96.6%; and Streptococcus pneumoniae, 100%). The specificities of the test modules ranged from 92.5 to 100% for gram-negative bacilli and 97.7 to 100% for gram-positive cocci (Escherichia coli, 92.5%; Pseudomonas aeruginosa, 98.5%; Klebsiella spp., 100%; Enterobacter aerogenes, 100%; S. aureus, 100%, S. epidermidis, 97.7%; Enterococcus faecalis/Enterococcus faecium, 99.6%; Streptococcus pyogenes, 100%; and Streptococcus pneumoniae, 99.3%). The result of the mecA gene detection module correlated with the result of the phenotypic oxacillin resistance testing in all 38 isolates of Staphylococcus aureus investigated. In conclusion, the Hyplex BloodScreen PCR-ELISA system is well suited for the direct and specific identification of the most common pathogenic bacteria and the direct detection of the mecA gene of Staphylococcus aureus in positive blood cultures.


Assuntos
Bacteriemia/diagnóstico , Bactérias Gram-Negativas/isolamento & purificação , Cocos Gram-Positivos/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Proteínas de Bactérias/genética , Ensaio de Imunoadsorção Enzimática , Bactérias Gram-Negativas/genética , Cocos Gram-Positivos/genética , Humanos , Proteínas de Ligação às Penicilinas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA