Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Vet Med Sci ; 86(7): 796-800, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38839352

RESUMO

The control of digital dermatitis (DD) among cattle is crucial; however, effective and environmentally-sound control measures have yet to be identified. From the monitoring data of DD which were recorded during regular hoof trimmings in a farm in Hokkaido, Japan, we detected a decrease in the DD prevalence in a herd where an anaerobic bacterial fermentation enhancer (ABFE) was distributed. The possible effect of ABFE was analyzed using a retrospective repeated cross-sectional design. The prevalence of DD decreased over time in the ABFE-distributed group. Furthermore, a selected regression model indicated the time-dependent enhancement of the decreasing trend. While potential coincidental factors may influence, this study provides a basis for further research on the preventive effect of ABFE against DD.


Assuntos
Doenças dos Bovinos , Dermatite Digital , Fermentação , Animais , Bovinos , Estudos Retrospectivos , Dermatite Digital/microbiologia , Dermatite Digital/prevenção & controle , Doenças dos Bovinos/microbiologia , Doenças dos Bovinos/prevenção & controle , Japão , Estudos Transversais , Bactérias Anaeróbias , Casco e Garras/microbiologia
2.
J Exp Orthop ; 11(3): e12031, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38741903

RESUMO

Purpose: Thermoelastic stress analysis (TSA) was used to evaluate stress changes over the entire surface of a specimen. This study aimed to assess the relationship between femoral stress distribution, analysed using TSA and changes in bone mineral density (BMD) after total hip arthroplasty (THA). Methods: Stress changes in the simulated bone before and after taper-wedge stem insertion were measured using the TSA. Stress changes were compared with BMD changes around the stem 1 year after surgery in a THA patient (58 hips) with the same taper-wedge stem. Subsequently, we compared the correlation between stress changes and BMD changes. Results: TSA revealed significant stress changes before and after stem insertion, with prominent alterations in the proximal medial region. The BMD changes at 1 year post-THA exhibited a 15%-25% decrease in the proximal zones, while Zones 2-6 showed a -6% to 3% change. Notably, a strong positive correlation (0.886) was found between the stress change rate and BMD change rate. Conclusions: This study demonstrated a high correlation between femoral stress distribution assessed using TSA and subsequent BMD changes after THA. The TSA method offers the potential to predict stress distribution and BMD alterations postsurgery, aiding in implant development and clinical assessment. Combining TSA with finite element analysis could provide even more detailed insights into stress distribution. Level of Evidence: Case series (with or without comparison).

3.
J Exp Orthop ; 10(1): 67, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37393331

RESUMO

PURPOSE: The adjustable loop cortical suspension device (ALD) is a useful femoral fixation device in anterior cruciate ligament (ACL) reconstructions, but the possibility of loosening has been suggested. The purpose of this study was to evaluate the elongation of an adjustable loop and the position of the hamstring graft inside the femoral socket. METHODS: The subjects were 33 patients who underwent ACL reconstruction with a hamstring tendon. The graft was fixed using ALD and completely filled the femoral socket. Magnetic resonance images were taken one week and one year after the operation. The loop length, femoral socket length, and graft length inside the socket were measured and statistically compared with the clinical outcomes. RESULTS: The loop length one week after surgery was 18.9 ± 4.4 mm, and 1 year after surgery was 19.9 ± 4.5 mm (P < 0.001). The gap between the top of the graft and femoral socket was 0.9 ± 1.8 mm one week after surgery and 1.3 ± 1.7 mm one year after surgery (P = 0.259). At one week post-operation, a gap was found in nine patients (27.3%). The loop length and gap did not strongly correlate with clinical findings. CONCLUSION: ACL reconstruction using ALD showed a gap between the graft and femoral socket at the one week post-operation mark in 27.3% of participants. One year after the surgery, there were cases where the gap increased and/or decreased, but the elongation of the loop was 1 mm on average. Our findings suggest that ALD is clinically safe to use; however, has the possibility of initial loop elongation and non-uniform changes. LEVEL OF EVIDENCE: IV.

4.
Arthroplast Today ; 21: 101140, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37151402

RESUMO

Background: Primary stability of the femoral stem is important for the long-term results of cementless total hip arthroplasty. Cementless collared stems have been known to have higher stability than collarless stems when there is a contact between the collar and the calcar. The purpose of this study was to compare the stabilities of collared stem and collarless stem in 2 loading conditions: 1) flat walking and 2) stair climbing. Methods: We constructed 3 finite element models. In the first model, the collar had contact with the calcar. The second model had a 1 mm gap between the calcar and the collar. The third model was constructed with a collarless stem. The proximal femur around the stem was divided into 3 zones: the upper zone (Gruen zones 1 and 7), the middle zone (Gruen zones 2 and 6), and the lower zone (Gruen zones 3 and 5). The micromotion at the stem/bone interface was measured at each zone of the 3 models under the 2 loading conditions. Results: The results showed that collared stems were more stable when the collar was in contact with the calcar than when a gap was left between the collar and the calcar. In particular, collar contact was highly effective in suppressing the micromotion proximal to the stem. Conclusions: Compared to the collarless stem, the collared stem had comparable stability when there was a gap at the collar and calcar interface and higher stability when there was contact between the collar and the calcar.

5.
J Surg Case Rep ; 2022(10): rjac478, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36285172

RESUMO

Tumor-induced osteomalacia (TIO) is a rare tumor-associated syndrome in which osteomalacia is induced by a tumor. A 67-year-old male patient presented for the first time with low back pain, weakness of the lower extremities and difficulty in walking. Six years earlier, he had nonspecific symptoms such as low back pain, and blood tests showed high alkaline phosphatase and low phosphorus. In addition, fibroblast growth factor 23 (FGF23) was abnormally high at 454 pg/mL. A diagnosis of FGF23-related hypophosphatemic osteomalacia was made. Somatostatin receptor scintigraphy, venous sampling and MRI were performed to localize and diagnose TIO. The tumor was found to be confined to the right femoral head and hemiarthroplasty was performed. Pathological examination revealed a phosphaturic mesenchymal tumor. Postoperatively, symptoms and blood test data improved. Although resection of the lesion and osteochondral transplantation or total hip arthroplasty were considered, hemiarthroplasty was chosen over concerns about treatment failure due to seeding.

6.
Acta Bioeng Biomech ; 24(2): 47-54, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38314493

RESUMO

PURPOSE: The aim of this study was to evaluate the stress distribution in a synthetic femur that was implanted with a fully hydroxyapatite-coated stem using thermoelastic stress and finite element analyses, and to clarify the differences in the stress distributions between these two methods. METHODS: Thermoelastic stress analysis is a stress-analysis technique that employs the thermoelastic effect. Sinusoidal vertical loads were applied to the head of the stem placed on the synthetic femur, and surface stress distribution images were acquired using an infrared stress measurement system. The finite element model for the synthetic femur and stem were set up similarly to the thermoelastic stress analysis experiment, and vertical load was applied to the head of the stem. Surface stress distribution and stress values obtained via these two methods were compared. RESULTS: Thermoelastic stress analysis showed that compressive and tensile stresses were distributed from the proximal femur to the diaphysis, not only on the medial and lateral surfaces, but also on the anterior and posterior surfaces. However, finite element analysis showed that compressive stress was not distributed on the anterior and posterior surfaces of the femoral intertrochanter. The stress values of thermoelastic stress analysis tended to be higher in the proximal femur than that obtained via the finite element analysis. CONCLUSIONS: The surface stress distribution obtained by these two methods were different specifically in the proximal femur. Our results imply that thermoelastic stress analysis has a better potential than finite element analysis to show the surface stress distribution that reflects the stem design.

7.
Diagnostics (Basel) ; 11(11)2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34829440

RESUMO

Digital tomosynthesis (DTS) is a new imaging technique derived from radiography, and its usefulness has been gradually reported in the field of orthopedic diagnosis in recent years. A fully hydroxyapatite (HA)-coated stem, which is used for total hip arthroplasty (THA), is a type of cementless stem that has been widely used recently and reported to have good results. However, stem loosening on plain radiographs is difficult to determine in some cases due to cancellous condensation around the stem. In this retrospective cross-sectional study, we compared the results of plain radiography versus DTS to evaluate the imaging findings after THA using a fully HA-coated stem. Twenty joints each in the 3 y and 1 y postoperative groups underwent plain radiography and DTS. On DTS, bone formation around the stem was confirmed in all cases; however, this formation was not reproducible on plain radiography, and there were cases in which the reaction could not be confirmed or cases with cancellous condensation resembling reactive lines. This reaction was not reproducible on plain radiographs, and in some cases, the reaction could not be confirmed, or there were cases with cancellous condensation that resembled reactive lines. Therefore, DTS was useful in the diagnosis of bone formation around the implant.

8.
Anim Sci J ; 88(10): 1588-1594, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28556305

RESUMO

The aim of the present study was to clarify the relationship between hypothalamic dopamine (DA) and salsolinol (SAL) for the secretion of prolactin (PRL) in goats. SAL or thyrotropin-releasing hormone (TRH) was intravenously injected into female goats treated with or without the D2 DA receptor antagonist haloperidol (Hal), which crosses the blood-brain barrier, and the PRL-releasing response to SAL was compared with that to TRH. PRL-releasing responses to SAL, Hal, and Hal plus SAL were also examined after a pretreatment to augment central DA using carbidopa (Carbi) and L-dopa. The PRL-releasing response to Hal alone was greater than that to SAL or TRH alone. The PRL-releasing response to Hal plus SAL was similar to that of Hal alone. In contrast, the PRL-releasing response to Hal plus TRH was greater than that to TRH or Hal alone. The treatment with Carbi plus L-dopa inhibited SAL- and Hal-induced PRL secretion. The inhibition of the PRL-releasing response to SAL disappeared when SAL was injected with Hal. These results indicate that the mechanisms underlying the SAL-induced PRL response differ from those of TRH, and suggest that hypothalamic DA and its synthesis is associated in part with SAL-induced PRL secretion in goats.


Assuntos
Dopamina/fisiologia , Cabras/metabolismo , Cabras/fisiologia , Hipotálamo , Isoquinolinas/farmacologia , Prolactina/metabolismo , Animais , Carbidopa/farmacologia , Antagonistas dos Receptores de Dopamina D2/farmacologia , Combinação de Medicamentos , Feminino , Haloperidol/farmacologia , Injeções Intravenosas , Isoquinolinas/administração & dosagem , Levodopa/farmacologia , Hormônio Liberador de Tireotropina/administração & dosagem , Hormônio Liberador de Tireotropina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA