Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Innovations (Phila) ; : 15569845241252170, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38835206

RESUMO

OBJECTIVE: There can be anatomical constraints on patient selection for minimally invasive surgery. For example, robot-assisted coronary artery bypass was reported to be more challenging when patients had a cardiothoracic ratio >50% and a sternum-vertebra anteroposterior and transverse diameter ratio <0.45. We sought to examine the impact of chest wall anatomic parameters on surgical outcomes in our totally endoscopic coronary artery bypass (TECAB) procedures. METHODS: We retrospectively reviewed patients who underwent robotic TECAB, all of whom had a preoperative chest radiograph at our institution from July 2017 to October 2021. The cohort was divided into 2 groups, which were patients undergoing single-vessel grafting using the left internal thoracic artery (ITA; group 1) and patients undergoing multivessel grafting with bilateral ITA grafts (group 2). We measured several anatomical parameters from the preoperative chest radiograph. RESULTS: A total of 352 patients undergoing TECAB were retrospectively analyzed. After exclusions, 193 were included in this study. In group 1 (n = 91), no parameters correlated with operative time. In group 2 (n = 102), a significant negative correlation was observed between operative time and the sternum-vertebrae anteroposterior diameter (rs = -0.228, P = 0.022) and lung anteroposterior diameter (rs = -0.246, P = 0.013). To confirm these results in group 2, a propensity-matched analysis was performed and showed a statistically significant difference in surgical time based on chest anteroposterior diameters. CONCLUSIONS: In single-vessel robotic TECAB, chest wall anatomic dimensions measured on chest radiograph did not affect operative time. In multivessel cases with bilateral ITA grafts, larger anteroposterior diameter correlated with shorter operative times.

2.
JTCVS Open ; 18: 209-220, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690440

RESUMO

Objectives: The complexity of aortic arch reconstruction due to diverse 3-dimensional geometrical abnormalities is a major challenge. This study introduces 3-dimensional printed tissue-engineered vascular grafts, which can fit patient-specific dimensions, optimize hemodynamics, exhibit antithrombotic and anti-infective properties, and accommodate growth. Methods: We procured cardiac magnetic resonance imaging with 4-dimensional flow for native porcine anatomy (n = 10), from which we designed tissue-engineered vascular grafts for the distal aortic arch, 4 weeks before surgery. An optimal shape of the curved vascular graft was designed using computer-aided design informed by computational fluid dynamics analysis. Grafts were manufactured and implanted into the distal aortic arch of porcine models, and postoperative cardiac magnetic resonance imaging data were collected. Pre- and postimplant hemodynamic data and histology were analyzed. Results: Postoperative magnetic resonance imaging of all pigs with 1:1 ratio of polycaprolactone and poly-L-lactide-co-ε-caprolactone demonstrated no specific dilatation or stenosis of the graft, revealing a positive growth trend in the graft area from the day after surgery to 3 months later, with maintaining a similar shape. The peak wall shear stress of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft portion did not change significantly between the day after surgery and 3 months later. Immunohistochemistry showed endothelization and smooth muscle layer formation without calcification of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft. Conclusions: Our patient-specific polycaprolactone/poly-L-lactide-co-ε-caprolactone tissue-engineered vascular grafts demonstrated optimal anatomical fit maintaining ideal hemodynamics and neotissue formation in a porcine model. This study provides a proof of concept of patient-specific tissue-engineered vascular grafts for aortic arch reconstruction.

3.
J Vis Exp ; (206)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38738890

RESUMO

Synthetic vascular grafts overcome some challenges of allografts, autografts, and xenografts but are often more rigid and less compliant than the native vessel into which they are implanted. Compliance matching with the native vessel is emerging as a key property for graft success. The current gold standard for assessing vessel compliance involves the vessel's excision and ex vivo biaxial mechanical testing. We developed an in vivo method to assess venous compliance and distensibility that better reflects natural physiology and takes into consideration the impact of a pressure change caused by flowing blood and by any morphologic changes present. This method is designed as a survival procedure, facilitating longitudinal studies while potentially reducing the need for animal use. Our method involves injecting a 20 mL/kg saline bolus into the venous vasculature, followed by the acquisition of pre and post bolus 3D angiograms to observe alterations induced by the bolus, concurrently with intravascular pressure measurements in target regions. We are then able to measure the circumference and the cross-sectional area of the vessel pre and post bolus. With these data and the intravascular pressure, we are able to calculate the compliance and distensibility with specific equations. This method was used to compare the inferior vena cava's compliance and distensibility in native unoperated sheep to the conduit of sheep implanted with a long-term expanded polytetrafluorethylene (PTFE) graft. The native vessel was found to be more compliant and distensible than the PTFE graft at all measured locations. We conclude that this method safely provides in vivo measurements of vein compliance and distensibility.


Assuntos
Veia Cava Inferior , Animais , Veia Cava Inferior/fisiologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Ovinos , Angiografia/métodos , Imageamento Tridimensional/métodos , Modelos Animais
4.
Nat Commun ; 15(1): 2187, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467617

RESUMO

Advancements in congenital heart surgery have heightened the importance of durable biomaterials for adult survivors. Dystrophic calcification poses a significant risk to the long-term viability of prosthetic biomaterials in these procedures. Herein, we describe the natural history of calcification in the most frequently used vascular conduits, expanded polytetrafluoroethylene grafts. Through a retrospective clinical study and an ovine model, we compare the degree of calcification between tissue-engineered vascular grafts and polytetrafluoroethylene grafts. Results indicate superior durability in tissue-engineered vascular grafts, displaying reduced late-term calcification in both clinical studies (p < 0.001) and animal models (p < 0.0001). Further assessments of graft compliance reveal that tissue-engineered vascular grafts maintain greater compliance (p < 0.0001) and distensibility (p < 0.001) than polytetrafluoroethylene grafts. These properties improve graft hemodynamic performance, as validated through computational fluid dynamics simulations. We demonstrate the promise of tissue engineered vascular grafts, remaining compliant and distensible while resisting long-term calcification, to enhance the long-term success of congenital heart surgeries.


Assuntos
Prótese Vascular , Calcinose , Ovinos , Animais , Estudos Retrospectivos , Calcinose/cirurgia , Materiais Biocompatíveis , Politetrafluoretileno
5.
Ann Thorac Surg Short Rep ; 2(1): 150-155, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38464466

RESUMO

BACKGROUND: We have developed a tissue engineered cardiac patch derived from a 3-dimensional (3D) myocardial tissue reinforced with extracellular matrix in an effort to enhance in situ myocardial regeneration. The feasibility of the patch was evaluated in a porcine model by various modalities to assess both the constructive and functional aspects of regeneration. METHODS: A spheroid-based 3D multicellular tissue was created using a 3D net mold system that incorporated cardiomyocytes and embryonic fibroblast cells. The 3D multicellular tissue was incorporated with extracellular matrix sheets and surgically implanted into the right ventricle of a healthy porcine model (n = 4). After 60 days, the implanted patches were evaluated by cardiac magnetic resonance imaging and electroanatomic mapping studies as well as by post-euthanasia analyses, including measurements of mechanical viscoelasticity. RESULTS: Cardiac magnetic resonance imaging revealed improved regional tissue perfusion in the patch area. Electroanatomic mapping exhibited regenerated electrical conductivity in the patch, as evidenced by relatively preserved voltage regions (1.11 ± 0.8 mV) in comparison to the normal right ventricle (4.7 ± 2.8 mV). Histologic and tissue analyses confirmed repopulation of site-specific host cells, including premature cardiomyocytes and active vasculogenesis. These findings were supported by quantitative reverse transcription-polymerase chain reaction. CONCLUSIONS: The tissue engineered cardiac patch effectively facilitated in situ constructive and functional myocardial regeneration, characterized by increased regional tissue perfusion and positive electrical activity in the porcine model.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA