Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Gland Surg ; 6(6): 689-697, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29302487

RESUMO

BACKGROUND: The central round block repair is a volume displacement technique to reconstruct large wide local excision (WLE) defects in breasts with moderate ptosis or hypertrophy. There are limited published data on the outcomes of this technique. METHODS: Data were collected prospectively for 57 consecutive patients and follow up information obtained from patient records. The volume of breast resection was estimated geometrically from mammography. Aesthetic outcomes were assessed from clinical measurements and panel review of patient photographs. RESULTS: The median age was 51 [22-86] years and follow-up 5 (1.9-8.4) years. The median specimen resection weight was 50 [25-361] g and tumour size 25 [10-75] mm. Estimated volume of breast excised was 17.8% (6-31%). In total, 12/57 patients had incomplete margins: five patients had re-excision to achieve clear margins and seven required mastectomy. Two patients had local recurrence during the follow-up period, five developed distant metastases. Aesthetic data were completed for 35/50 patients. Twelve (34%) had no measurable asymmetry and 31 (89%) had a nipple position within 2 cm of the original height. Only two patients requested symmetrising surgery. CONCLUSIONS: Central round block reconstruction of large defects after WLE is a safe technique with good aesthetic outcomes. Contralateral symmetrising surgery is not usually required.

2.
Breast Cancer Res Treat ; 141(1): 33-42, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23954989

RESUMO

The standard for the treatment of early non-palpable breast cancers is wide local excision directed by wire-guided localization and sentinel lymph node biopsy (SLNB). This has drawbacks technically and due to reliance upon radioisotopes. We evaluated the use of a magnetic tracer for its localization capabilities and concurrent performance of SLNB using a handheld magnetometer in a porcine model as a novel alternative to the current standard. Ethical approval by the IRCAD Ethics Review Board, Strasbourg (France) was received. A magnetic tracer was injected in varying volumes (0.1-5 mL) subcutaneously into the areolar of the left and right 3rd inguinal mammary glands in 16 mini-pigs. After 4 h magnetometer counts were taken at the injection sites and in the groins. The magnetometer was used to localize any in vivo signal from the draining inguinal lymph nodes. Magnetic SLNB followed by excision of the injection site was performed. The iron content of sentinel lymph nodes (SLNs) were graded and quantified. All excised specimens were weighed and volumes were calculated. Univariate analyses were performed to evaluate correlation. Magnetic SLNB was successful in all mini-pigs. There was a significant correlation (r = 0.86; p < 0.01) between magnetometer counts and iron content of SLNs. Grading of SLNs on both H&E and Perl's staining correlated significantly with the iron content (p = 0.001; p = 0.003) and magnetometer counts (p < 0.001; p = 0.004). The peak counts corresponded to the original magnetic tracer injection sites 4 h after injection in all cases. The mean volume and weight of excised injection site specimens was 2.9 cm(3) (SD 0.81) and 3.1 g (SD 0.85), respectively. Injection of ≥0.5 mL magnetic tracer was associated with significantly greater volume (p = 0.05) and weight of excision specimens (p = 0.01). SLNB and localization can be performed in vivo using a magnetic tracer. This could provide a viable alternative for lesion localization and concurrent SLNB in the treatment of non-palpable breast cancer.


Assuntos
Meios de Contraste , Compostos Férricos , Linfonodos/química , Magnetismo , Glândulas Mamárias Animais/anatomia & histologia , Nanopartículas , Biópsia de Linfonodo Sentinela/métodos , Animais , Meios de Contraste/administração & dosagem , Avaliação Pré-Clínica de Medicamentos , Feminino , Compostos Férricos/administração & dosagem , Virilha , Injeções , Linfonodos/anatomia & histologia , Magnetismo/instrumentação , Nanopartículas/administração & dosagem , Corantes de Rosanilina , Biópsia de Linfonodo Sentinela/instrumentação , Suínos , Porco Miniatura , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA