Cytotherapy ; 16(11): 1545-1557, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24972743

RESUMO

BACKGROUND AIMS: Delivery of cell-based therapies through the carotid artery with the use of an intra-arterial catheter could introduce aggregates and cause focal ischemia in the brain. We developed a pulse-width flow cytometry method for aggregate detection and quantification. The assay was designed to be used as a cell product release assay in a clinical trial seeking to treat ischemic stroke with sorted cells brightly expressing aldehyde dehydrogenase (ALDH(br) cells) delivered through intra-arterial catheters. METHODS: The forward light scatter pulse-width axis of a flow cytometer was calibrated for particle diameter measurements through the use of traceable standard microspheres and linear regression. As a positive control, Concanavalin A-aggregated cells were counted manually and sorted onto slides to compare with pulse width-determined values. Known numbers of aggregates were spiked into purified singlet cells for quantification. A clinical standard for aggregate count and diameter was determined. The assay was used to qualify catheters with the use of ALDH(br) cells. RESULTS: The pulse-width axis was highly linear for microsphere diameter (r(2) > 0.99), which allowed for size calibration. Microscopically determined counts and diameters corresponded to pulse width-determined values. Known aggregate counts were linear with pulse width-determined aggregate counts (r(2) = 0.98). The limit of detection was determined to be 0.004%. Flow of ALDH(br) cells through catheters did not generate aggregates. The final method to be used as a release assay for the stroke clinical trial was tested successfully on samples from volunteer donors. CONCLUSIONS: The pulse-width aggregate detection assay provides a reliable, reproducible, accurate and rapid means of detection, classification and quantification of aggregates in cell therapy products.


Assuntos
Aldeído Desidrogenase/biossíntese , Isquemia Encefálica/diagnóstico , Agregação Celular , Terapia Baseada em Transplante de Células e Tecidos/efeitos adversos , Citometria de Fluxo , Acidente Vascular Cerebral/patologia , Aldeído Desidrogenase/isolamento & purificação , Células da Medula Óssea/patologia , Isquemia Encefálica/imunologia , Catéteres/efeitos adversos , Regulação da Expressão Gênica , Humanos , Limite de Detecção , Células-Tronco/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA