Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Chem ; 62(2): 94-100, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38173282

RESUMO

The para spin isomer of hydrogen gas possesses high nuclear spin order that can enhance the NMR signals of a variety of molecular species. Hydrogen is routinely enriched in the para spin state by lowering the gas temperature while flowing through a catalyst. Although parahydrogen enrichments approaching 100% are achievable near the H2 liquefaction temperature of 20 K, many experimentalists operate at liquid nitrogen temperatures (77 K) due to the lower associated costs and overall simplicity of the parahydrogen generator. Parahydrogen that is generated at 77 K provides an enrichment value of ~51% of the para spin isomer; while useful, there are many applications that can benefit from low-cost access to higher parahydrogen enrichments. Here, we introduce a method of improving parahydrogen enrichment values using a liquid nitrogen-cooled generator that operates at temperatures less than 77 K. The boiling temperature of liquid nitrogen is lowered through internal evaporation into helium gas bubbles that are injected into the liquid. Changes to liquid nitrogen temperatures and parahydrogen enrichment values were monitored as a function of helium gas flow rate. The injected helium bubbles lowered the liquid nitrogen temperature to ~65.5 K, and parahydrogen enrichments of up to ~59% were achieved; this represents an ~16% improvement compared with the expected parahydrogen fraction at 77 K. This technique is simple to implement in standard liquid nitrogen-cooled parahydrogen generators and may be of interest to a wide range of scientists that require a cost-effective approach to improving parahydrogen enrichment values.

2.
Molecules ; 28(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36903572

RESUMO

The application of parahydrogen gas to enhance the magnetic resonance signals of a diversity of chemical species has increased substantially in the last decade. Parahydrogen is prepared by lowering the temperature of hydrogen gas in the presence of a catalyst; this enriches the para spin isomer beyond its normal abundance of 25% at thermal equilibrium. Indeed, parahydrogen fractions that approach unity can be attained at sufficiently low temperatures. Once enriched, the gas will revert to its normal isomeric ratio over the course of hours or days, depending on the surface chemistry of the storage container. Although parahydrogen enjoys long lifetimes when stored in aluminum cylinders, the reconversion rate is significantly faster in glass containers due to the prevalence of paramagnetic impurities that are present within the glass. This accelerated reconversion is especially relevant for nuclear magnetic resonance (NMR) applications due to the use of glass sample tubes. The work presented here investigates how the parahydrogen reconversion rate is affected by surfactant coatings on the inside surface of valved borosilicate glass NMR sample tubes. Raman spectroscopy was used to monitor changes to the ratio of the (J: 0 → 2) vs. (J: 1 → 3) transitions that are indicative of the para and ortho spin isomers, respectively. Nine different silane and siloxane-based surfactants of varying size and branching structures were examined, and most increased the parahydrogen reconversion time by 1.5×-2× compared with equivalent sample tubes that were not treated with surfactant. This includes expanding the pH2 reconversion time from 280 min in a control sample to 625 min when the same tube is coated with (3-Glycidoxypropyl)trimethoxysilane.

3.
Carbohydr Polym ; 304: 120490, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36641177

RESUMO

With an increase in the severity of environmental pollution caused by microbeads, the development of biodegradable microcapsules that can be applied in diverse fields has attracted significant attention. The degradation processes are directly related to biodegradable microcapsule creation with high stability and persistence. In this study, biodegradable microcapsules are synthesized via a complex coacervation approach using gelatin and alginate as the capsule main wall materials; additionally, enzyme-induced decomposition mechanisms are proposed by observing spectral changes in proton nuclear magnetic resonance (1H NMR) analyses. Additional analytical techniques confirm the chemical structure, morphology, and size distribution of the synthesized capsules; these uniform spherical microcapsules are 20-30 µm in size and possess a smooth surface. In addition to characterization, the microcapsules were exposed to targeted enzymes to investigate enzymatic effects using short-term and long-term degradation kinetics. Close inspection reveals that determination of the degradation rate constant of the major components in the capsule is feasible, and suggests two types of 4-stage degradation mechanisms that are enzyme-specific. These investigations demonstrate that capsule degradation can be explored in detail using 1H NMR spectroscopy to provide a viable strategy for monitoring degradation properties in the development of new biodegradable polymers.


Assuntos
Alginatos , Gelatina , Cápsulas/química , Alginatos/química , Cinética , Espectroscopia de Ressonância Magnética
4.
Anal Chem ; 95(2): 907-916, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36514301

RESUMO

29Si silica nanoparticles (SiO2 NPs) are promising magnetic resonance imaging (MRI) probes that possess advantageous properties for in vivo applications, including suitable biocompatibility, tailorable properties, and high water dispersibility. Dynamic nuclear polarization (DNP) is used to enhance 29Si MR signals via enhanced nuclear spin alignment; to date, there has been limited success employing DNP for SiO2 NPs due to the lack of endogenous electronic defects that are required for the process. To create opportunities for SiO2-based 29Si MRI probes, we synthesized variously featured SiO2 NPs with selective 29Si isotope enrichment on homogeneous and core@shell structures (shell thickness: 10 nm, core size: 40 nm), and identified the critical factors for optimal DNP signal enhancement as well as the effective hyperpolarization depth when using an exogenous radical. Based on the synthetic design, this critical factor is the proportion of 29Si in the shell layer regardless of core enrichment. Furthermore, the effective depth of hyperpolarization is less than 10 nm between the surface and core, which demonstrates an approximately 40% elongated diffusion length for the shell-enriched NPs compared to the natural abundance NPs. This improved regulation of surface properties facilitates the development of isotopically enriched SiO2 NPs as hyperpolarized contrast agents for in vivo MRI.


Assuntos
Nanopartículas , Dióxido de Silício , Dióxido de Silício/química , Nanopartículas/química , Meios de Contraste/química , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
5.
Analyst ; 147(24): 5607-5612, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36377709

RESUMO

The embedding of radicals at different locations within core@shell silica nanoparticles contributes to enhanced polarization capability and can be self-polarized without adding external radicals. With grafting the radical source homogenously inside of the nanoparticles, a significant 29Si hyperpolarization signal enhancement of 49.4 was obtained.


Assuntos
Nanopartículas , Dióxido de Silício , Dióxido de Silício/química , Espectroscopia de Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Nanopartículas/química
6.
J Magn Reson ; 341: 107249, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35717743

RESUMO

The isomeric enrichment of parahydrogen (pH2) gas is readily accomplished by lowering the gas temperature in the presence of a catalyst. This enrichment is often pursued at two distinct temperatures: ∼51% pH2 is generated at liquid nitrogen temperatures (77 K), while nearly 100% pH2 can be produced at 20 K. While the liquid nitrogen cooled generator is attractive due to the low cost of entry, there are benefits to having access to greater than 51% pH2 for enhanced NMR applications. In this work, we introduce a low-cost modification to an existing laboratory-constructed liquid nitrogen cooled pH2 generator that provides âˆ¼ 65% pH2. This modification takes advantage of vacuum-mediated boiling point suppression of liquid nitrogen, allowing the temperature of the liquid to be lowered from 77 K to nitrogen's triple point of 63 K. The reduced temperature allowed for the generation of parahydrogen fractions of 63-67% at gas flow rates from 20 to 1000 standard cubic centimeters per minute. We compare this to equivalent experiments that did not utilize the temperature-lowering effects of pressure reduction; these controls generally maintained pH2 fractions of âˆ¼ 50%. All results (experimental and control) agree with the theoretically expected parahydrogen generation at these temperatures. This straightforward modification to an existing pH2 generator may be of interest to a broad range of scientists involved with parahydrogen research by introducing a simple and low-cost entryway to increased pH2 fractions using a conventional liquid nitrogen cooled generator.

7.
Diagnostics (Basel) ; 12(3)2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35328163

RESUMO

Medical imaging devices often use automated processing that creates and displays a self-normalized image. When improperly executed, normalization can misrepresent information or result in an inaccurate analysis. In the case of diagnostic imaging, a false positive in the absence of disease, or a negative finding when disease is present, can produce a detrimental experience for the patient and diminish their health prospects and prognosis. In many clinical settings, a medical technical specialist is trained to operate an imaging device without sufficient background information or understanding of the fundamental theory and processes involved in image creation and signal processing. Here, we describe a user-friendly image processing algorithm that mitigates user bias and allows for true signal to be distinguished from background. For proof-of-principle, we used antibody-targeted molecular imaging of colorectal cancer (CRC) in a mouse model, expressing human MUC1 at tumor sites. Lesion detection was performed using targeted magnetic resonance imaging (MRI) of hyperpolarized silicon particles. Resulting images containing high background and artifacts were then subjected to individualized image post-processing and comparative analysis. Post-acquisition image processing allowed for co-registration of the targeted silicon signal with the anatomical proton magnetic resonance (MR) image. This new methodology allows users to calibrate a set of images, acquired with MRI, and reliably locate CRC tumors in the lower gastrointestinal tract of living mice. The method is expected to be generally useful for distinguishing true signal from background for other cancer types, improving the reliability of diagnostic MRI.

8.
ACS Appl Mater Interfaces ; 13(48): 56923-56930, 2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34793118

RESUMO

Silicon particles have garnered attention as promising biomedical probes for hyperpolarized 29Si magnetic resonance imaging and spectroscopy. However, due to the limited levels of hyperpolarization for nanosized silicon particles, microscale silicon particles have primarily been the focus of dynamic nuclear polarization (DNP) applications, including in vivo magnetic resonance imaging (MRI). To address these current challenges, we developed a facile synthetic method for partially 29Si-enriched porous silicon nanoparticles (NPs) (160 nm) and examined their usability in hyperpolarized 29Si MRI agents with enhanced signals in spectroscopy and imaging. Hyperpolarization characteristics, such as the build-up constant, the depolarization time (T1), and the overall enhancement of the 29Si-enriched silicon NPs (10 and 15%), were thoroughly investigated and compared with those of a naturally abundant NP (4.7%). During optimal DNP conditions, the 15% enriched silicon NPs showed more than 16-fold higher enhancements─far beyond the enrichment ratio─than the naturally abundant sample, further improving the signal-to-noise ratio in in vivo 29Si MRI. The 29Si-enriched porous silicon NPs used in this work are potentially capable to serve as drug-delivery vehicles in addition to hyperpolarized 29Si in vivo, further enabling their potential future applicability as a theragnostic platform.


Assuntos
Materiais Biomiméticos/química , Meios de Contraste/química , Imageamento por Ressonância Magnética , Nanopartículas/química , Membro Fantasma/diagnóstico por imagem , Silício/química , Animais , Materiais Biomiméticos/administração & dosagem , Materiais Biomiméticos/síntese química , Meios de Contraste/administração & dosagem , Meios de Contraste/síntese química , Isótopos , Masculino , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Nanopartículas/administração & dosagem , Tamanho da Partícula , Porosidade , Silício/administração & dosagem
9.
J Magn Reson ; 312: 106686, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32006793

RESUMO

Spin-exchange optical pumping (SEOP) can enhance the NMR sensitivity of noble gases by up to five orders of magnitude at Tesla-strength magnetic fields. SEOP-generated hyperpolarised (HP) 129Xe is a promising contrast agent for lung imaging but an ongoing barrier to widespread clinical usage has been economical production of sufficient quantities with high 129Xe polarisation. Here, the 'standard model' of SEOP, which was previously used in the optimisation of continuous-flow 129Xe polarisers, is modified for validation against two Xe-rich stopped-flow SEOP datasets. We use this model to examine ways to increase HP Xe production efficiency in stopped-flow 129Xe polarisers and provide further insight into the underlying physics of Xe-rich stopped-flow SEOP at high laser fluxes.


Assuntos
Meios de Contraste/química , Pulmão/diagnóstico por imagem , Espectroscopia de Ressonância Magnética/métodos , Rubídio/química , Isótopos de Xenônio/química , Simulação por Computador , Conjuntos de Dados como Assunto , Lasers , Fótons , Sensibilidade e Especificidade
10.
Chemphyschem ; 19(17): 2143-2147, 2018 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-29779258

RESUMO

Porous silicon nanoparticles have recently garnered attention as potentially-promising biomedical platforms for drug delivery and medical diagnostics. Here, we demonstrate porous silicon nanoparticles as contrast agents for 29 Si magnetic resonance imaging. Size-controlled porous silicon nanoparticles were synthesized by magnesiothermic reduction of silica nanoparticles and were surface activated for further functionalization. Particles were hyperpolarized via dynamic nuclear polarization to enhance their 29 Si MR signals; the particles demonstrated long 29 Si spin-lattice relaxation (T1 ) times (∼25 mins), which suggests potential applicability for medical imaging. Furthermore, 29 Si hyperpolarization levels were sufficient to allow 29 Si MRI in phantoms. These results underscore the potential of porous silicon nanoparticles that, when combined with hyperpolarized magnetic resonance imaging, can be a powerful theragnostic deep tissue imaging platform to interrogate various biomolecular processes in vivo.


Assuntos
Imageamento por Ressonância Magnética , Nanopartículas/química , Silício/química , Meios de Contraste/química , Isótopos/química , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , Porosidade , Propilaminas/química , Silanos/química
11.
Magn Reson Imaging Clin N Am ; 24(4): 687-703, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27742110

RESUMO

This article reviews existing and emerging techniques of interrogating metabolism in brain cancer from well-established proton magnetic resonance spectroscopy to the promising hyperpolarized metabolic imaging and chemical exchange saturation transfer and emerging techniques of imaging inflammation. Some of these techniques are at an early stage of development and clinical trials are in progress in patients to establish the clinical efficacy. It is likely that in vivo metabolomics and metabolic imaging is the next frontier in brain cancer diagnosis and assessing therapeutic efficacy; with the combined knowledge of genomics and proteomics a complete understanding of tumorigenesis in brain might be achieved.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Humanos
12.
J Med Imaging (Bellingham) ; 3(3): 036001, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27547777

RESUMO

Silicon-based nanoparticles are ideally suited for use as biomedical imaging agents due to their biocompatibility, biodegradability, and simple surface chemistry that facilitates drug loading and targeting. A method of hyperpolarizing silicon particles using dynamic nuclear polarization, which increases magnetic resonance imaging signals by several orders-of-magnitude through enhanced nuclear spin alignment, has recently been developed to allow silicon particles to function as contrast agents for in vivo magnetic resonance imaging. The enhanced spin polarization of silicon lasts significantly longer than other hyperpolarized agents (tens of minutes, whereas [Formula: see text] for other species at room temperature), allowing a wide range of potential applications. We report our recent characterizations of hyperpolarized silicon particles, with the ultimate goal of targeted, noninvasive, and nonradioactive molecular imaging of various cancer systems. A variety of particle sizes (20 nm to [Formula: see text]) were found to have hyperpolarized relaxation times ranging from [Formula: see text] to 50 min. The addition of various functional groups to the particle surface had no effect on the hyperpolarization buildup or decay rates and allowed in vivo imaging over long time scales. Additional in vivo studies examined a variety of particle administration routes in mice, including intraperitoneal injection, rectal enema, and oral gavage.

13.
Sci Rep ; 5: 12842, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-26239953

RESUMO

Visualizing the movement of angiocatheters during endovascular interventions is typically accomplished using x-ray fluoroscopy. There are many potential advantages to developing magnetic resonance imaging-based approaches that will allow three-dimensional imaging of the tissue/vasculature interface while monitoring other physiologically-relevant criteria, without exposing the patient or clinician team to ionizing radiation. Here we introduce a proof-of-concept development of a magnetic resonance imaging-guided catheter tracking method that utilizes hyperpolarized silicon particles. The increased signal of the silicon particles is generated via low-temperature, solid-state dynamic nuclear polarization, and the particles retain their enhanced signal for ≥ 40 minutes--allowing imaging experiments over extended time durations. The particles are affixed to the tip of standard medical-grade catheters and are used to track passage under set distal and temporal points in phantoms and live mouse models. With continued development, this method has the potential to supplement x-ray fluoroscopy and other MRI-guided catheter tracking methods as a zero-background, positive contrast agent that does not require ionizing radiation.


Assuntos
Meios de Contraste/química , Fluoroscopia/métodos , Imageamento por Ressonância Magnética/métodos , Silício/química , Animais , Fluoroscopia/instrumentação , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Camundongos , Camundongos Transgênicos , Imagens de Fantasmas , Fatores de Tempo , Cateteres Urinários , Dispositivos de Acesso Vascular
14.
Magn Reson Imaging ; 32(5): 541-50, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24631715

RESUMO

Here we provide a full report on the construction, components, and capabilities of our consortium's "open-source" large-scale (~1L/h) (129)Xe hyperpolarizer for clinical, pre-clinical, and materials NMR/MRI (Nikolaou et al., Proc. Natl. Acad. Sci. USA, 110, 14150 (2013)). The 'hyperpolarizer' is automated and built mostly of off-the-shelf components; moreover, it is designed to be cost-effective and installed in both research laboratories and clinical settings with materials costing less than $125,000. The device runs in the xenon-rich regime (up to 1800Torr Xe in 0.5L) in either stopped-flow or single-batch mode-making cryo-collection of the hyperpolarized gas unnecessary for many applications. In-cell (129)Xe nuclear spin polarization values of ~30%-90% have been measured for Xe loadings of ~300-1600Torr. Typical (129)Xe polarization build-up and T1 relaxation time constants were ~8.5min and ~1.9h respectively under our spin-exchange optical pumping conditions; such ratios, combined with near-unity Rb electron spin polarizations enabled by the high resonant laser power (up to ~200W), permit such high PXe values to be achieved despite the high in-cell Xe densities. Importantly, most of the polarization is maintained during efficient HP gas transfer to other containers, and ultra-long (129)Xe relaxation times (up to nearly 6h) were observed in Tedlar bags following transport to a clinical 3T scanner for MR spectroscopy and imaging as a prelude to in vivo experiments. The device has received FDA IND approval for a clinical study of chronic obstructive pulmonary disease subjects. The primary focus of this paper is on the technical/engineering development of the polarizer, with the explicit goals of facilitating the adaptation of design features and operative modes into other laboratories, and of spurring the further advancement of HP-gas MR applications in biomedicine.


Assuntos
Análise de Injeção de Fluxo/instrumentação , Calefação/instrumentação , Marcação por Isótopo/instrumentação , Robótica/instrumentação , Análise Espectral/instrumentação , Isótopos de Xenônio/síntese química , Isótopos de Xenônio/isolamento & purificação , Desenho de Equipamento , Falha de Equipamento , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/isolamento & purificação
15.
Proc Natl Acad Sci U S A ; 110(35): 14150-5, 2013 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-23946420

RESUMO

The exquisite NMR spectral sensitivity and negligible reactivity of hyperpolarized xenon-129 (HP(129)Xe) make it attractive for a number of magnetic resonance applications; moreover, HP(129)Xe embodies an alternative to rare and nonrenewable (3)He. However, the ability to reliably and inexpensively produce large quantities of HP(129)Xe with sufficiently high (129)Xe nuclear spin polarization (P(Xe)) remains a significant challenge--particularly at high Xe densities. We present results from our "open-source" large-scale (∼1 L/h) (129)Xe polarizer for clinical, preclinical, and materials NMR and MRI research. Automated and composed mostly of off-the-shelf components, this "hyperpolarizer" is designed to be readily implementable in other laboratories. The device runs with high resonant photon flux (up to 200 W at the Rb D1 line) in the xenon-rich regime (up to 1,800 torr Xe in 500 cc) in either single-batch or stopped-flow mode, negating in part the usual requirement of Xe cryocollection. Excellent agreement is observed among four independent methods used to measure spin polarization. In-cell P(Xe) values of ∼90%, ∼57%, ∼50%, and ∼30% have been measured for Xe loadings of ∼300, ∼500, ∼760, and ∼1,570 torr, respectively. P(Xe) values of ∼41% and ∼28% (with ∼760 and ∼1,545 torr Xe loadings) have been measured after transfer to Tedlar bags and transport to a clinical 3 T scanner for MR imaging, including demonstration of lung MRI with a healthy human subject. Long "in-bag" (129)Xe polarization decay times have been measured (T1 ∼38 min and ∼5.9 h at ∼1.5 mT and 3 T, respectively)--more than sufficient for a variety of applications.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Isótopos de Xenônio/química , Humanos , Pulmão/patologia
16.
J Magn Reson ; 208(2): 298-304, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21185208

RESUMO

The (129)Xe nuclear spin polarization (P(Xe)) that can be achieved via spin-exchange optical pumping (SEOP) is typically limited at high in-cell xenon densities ([Xe](cell)), due primarily to corresponding reductions in the alkali metal electron spin polarization (e.g. P(Rb)) caused by increased non-spin-conserving Rb-Xe collisions. While demonstrating the utility of volume holographic grating (VHG)-narrowed lasers for Rb/(129)Xe SEOP, we recently reported [P. Nikolaou et al., JMR 197 (2009) 249] an anomalous dependence of the observed P(Xe) on the in-cell xenon partial pressure (p(Xe)), wherein P(Xe) values were abnormally low at decreased p(Xe), peaked at moderate p(Xe) (~300 torr), and remained surprisingly elevated at relatively high p(Xe) values (>1000 torr). Using in situ low-field (129)Xe NMR, it is shown that the above effects result from an unexpected, inverse relationship between the xenon partial pressure and the optimal cell temperature (T(OPT)) for Rb/(129)Xe SEOP. This interdependence appears to result directly from changes in the efficiency of one or more components of the Rb/(129)Xe SEOP process, and can be exploited to achieve improved P(Xe) with relatively high xenon densities measured at high field (including averaged P(Xe) values of ~52%, ~31%, ~22%, and ~11% at 50, 300, 500, and 2000 torr, respectively).


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Rubídio/química , Xenônio/química , Algoritmos , Campos Eletromagnéticos , Lasers , Espectroscopia de Ressonância Magnética/métodos , Temperatura , Isótopos de Xenônio
17.
J Magn Reson ; 197(2): 249-54, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19162517

RESUMO

Volume holographic gratings (VHGs) can be exploited to narrow the spectral output of high-power laser-diode arrays (LDAs) by nearly an order of magnitude, permitting more efficient generation of laser-polarized noble gases for various applications. A approximately 3-fold improvement in (129)Xe nuclear spin polarization, P(Xe), (compared to a conventional LDA) was achieved with the VHG-LDA's center wavelength tuned to a wing of the Rb D(1) line. Additionally, an anomalous dependence of P(Xe) on the xenon density within the OP cell is reported-including high P(Xe) values (>10%) at high xenon partial pressures (approximately 1000 torr).


Assuntos
Holografia/métodos , Espectroscopia de Ressonância Magnética/métodos , Xenônio/química , Pressão do Ar , Lasers , Marcadores de Spin , Temperatura , Radioisótopos de Xenônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA