Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Health Technol Assess ; 28(32): 1-136, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39023220

RESUMO

Background: Most neovascular age-related macular degeneration treatments involve long-term follow-up of disease activity. Home monitoring would reduce the burden on patients and those they depend on for transport, and release clinic appointments for other patients. The study aimed to evaluate three home-monitoring tests for patients to use to detect active neovascular age-related macular degeneration compared with diagnosing active neovascular age-related macular degeneration by hospital follow-up. Objectives: There were five objectives: Estimate the accuracy of three home-monitoring tests to detect active neovascular age-related macular degeneration. Determine the acceptability of home monitoring to patients and carers and adherence to home monitoring. Explore whether inequalities exist in recruitment, participants' ability to self-test and their adherence to weekly testing during follow-up. Provide pilot data about the accuracy of home monitoring to detect conversion to neovascular age-related macular degeneration in fellow eyes of patients with unilateral neovascular age-related macular degeneration. Describe challenges experienced when implementing home-monitoring tests. Design: Diagnostic test accuracy cohort study, stratified by time since starting treatment. Setting: Six United Kingdom Hospital Eye Service macular clinics (Belfast, Liverpool, Moorfields, James Paget, Southampton, Gloucester). Participants: Patients with at least one study eye being monitored by hospital follow-up. Reference standard: Detection of active neovascular age-related macular degeneration by an ophthalmologist at hospital follow-up. Index tests: KeepSight Journal: paper-based near-vision tests presented as word puzzles. MyVisionTrack®: electronic test, viewed on a tablet device. MultiBit: electronic test, viewed on a tablet device. Participants provided test scores weekly. Raw scores between hospital follow-ups were summarised as averages. Results: Two hundred and ninety-seven patients (mean age 74.9 years) took part. At least one hospital follow-up was available for 317 study eyes, including 9 second eyes that became eligible during follow-up, in 261 participants (1549 complete visits). Median testing frequency was three times/month. Estimated areas under receiver operating curves were < 0.6 for all index tests, and only KeepSight Journal summary score was significantly associated with the lesion activity (odds ratio = 3.48, 95% confidence interval 1.09 to 11.13, p = 0.036). Older age and worse deprivation for home address were associated with lower participation (χ2 = 50.5 and 24.3, respectively, p < 0.001) but not ability or adherence to self-testing. Areas under receiver operating curves appeared higher for conversion of fellow eyes to neovascular age-related macular degeneration (0.85 for KeepSight Journal) but were estimated with less precision. Almost half of participants called a study helpline, most often due to inability to test electronically. Limitations: Pre-specified sample size not met; participants' difficulties using the devices; electronic tests not always available. Conclusions: No index test provided adequate test accuracy to identify lesion diagnosed as active in follow-up clinics. If used to detect conversion, patients would still need to be monitored at hospital. Associations of older age and worse deprivation with study participation highlight the potential for inequities with such interventions. Provision of reliable electronic testing was challenging. Future work: Future studies evaluating similar technologies should consider: Independent monitoring with clear stopping rules based on test performance. Deployment of apps on patients' own devices since providing devices did not reduce inequalities in participation and complicated home testing. Alternative methods to summarise multiple scores over the period preceding a follow-up. Trial registration: This trial is registered as ISRCTN79058224. Funding: This award was funded by the National Institute of Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 15/97/02) and is published in full in Health Technology Assessment; Vol. 28, No. 32. See the NIHR Funding and Awards website for further award information.


Treatment for neovascular age-related macular degeneration, the most common cause of sight loss in those over 50 years, involves regular eye injections and frequent follow-up appointments. This is inconvenient for patients and causes capacity issues in the hospital eye service. Finding tests that could be undertaken at home that could detect if a further injection and hospital appointment was required or not would increase capacity to see those at highest risk of sight loss and also reduce the burden on patients and their carers. We investigated three different visual function tests, one paper-based and two applications on an iPod TouchTM tablet (Apple, Cupertino, CA, USA). We wanted to see if they could detect an increase in disease activity that would require treatment, compared to the decision by a retinal specialist at a traditional hospital eye outpatient visit based on clinical examination and retinal imaging. To encourage those without a smartphone or home internet to participate, we provided both an iPod Touch and Mobile Wireless-Fidelity device with a mobile contract. None of the tests performed well enough to safely monitor patients at home. Those who were willing to participate tended to be younger, had previous experience of using smartphones, sending e-mail and internet access and were more well-off than those who chose not to participate. Some participants also experienced difficulties with the devices provided and successfully uploading the data which were not related to the extent of previous information technology experience. There were also significant technical challenges for the research team. The study helpline was used heavily, considerably more than we anticipated. These tests are not ready to be used in this context. Future studies involving mobile health technology need to carefully consider how to reach those unlikely to participate and provide sufficient technical support to support long-term follow-up.


Assuntos
Degeneração Macular , Humanos , Reino Unido , Idoso , Masculino , Feminino , Idoso de 80 Anos ou mais , Degeneração Macular/diagnóstico , Acuidade Visual , Avaliação da Tecnologia Biomédica
2.
Stud Health Technol Inform ; 315: 425-429, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39049295

RESUMO

This study formed part of a diagnostic test accuracy study to quantify the ability of three index home monitoring (HM) tests (one paper-based and two digital tests) to identify reactivation in Neovascular age-related macular degeneration (nAMD). The aim of the study was to investigate views about acceptability and explore adherence to weekly HM. Semi-structured interviews were held with 98 patients, family members, and healthcare professionals. A thematic approach was used which was informed by theories of technology acceptance. Various factors influenced acceptability including a patient's understanding about the purpose of monitoring. Training and ongoing support were regarded as essential for overcoming unfamiliarity with digital technology. Findings have implications for implementation of digital HM in the care of older people with nAMD and other long-term conditions.


Assuntos
Degeneração Macular , Humanos , Masculino , Feminino , Degeneração Macular/diagnóstico , Idoso , Aceitação pelo Paciente de Cuidados de Saúde , Pesquisa Qualitativa , Serviços de Assistência Domiciliar , Monitorização Ambulatorial/métodos , Idoso de 80 Anos ou mais , Degeneração Macular Exsudativa/diagnóstico
3.
BMC Cancer ; 24(1): 702, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849715

RESUMO

BACKGROUND: Cervical cancer is the fourth most common cancer in women, with an estimated 342,000 deaths worldwide in 2020. Current standard of care in the UK for locally advanced cervical cancer is concurrent chemoradiotherapy with weekly cisplatin, yet 5-year overall survival rates are only 65% with a distant relapse rate of 50%. Inhibitors of Apoptosis Proteins (IAPs) are often overexpressed in cancer cells and associated with tumour progression and resistance to treatment. Tolinapant, developed by Astex Pharmaceuticals, is an IAP antagonist with an additional mechanism of action via down-regulation of NF-kB, an important regulator in cervical cancer. Preclinical studies performed using tolinapant in combination with cisplatin and radiotherapy showed inhibition of tumour growth and enhanced survival. There is therefore a strong rationale to combine tolinapant with chemoradiotherapy (CRT). METHODS: CRAIN is a phase Ib open-label, dose escalation study to characterise the safety, tolerability and initial evidence for clinical activity of tolinapant when administered in combination with cisplatin based CRT. Up to 42 patients with newly diagnosed cervix cancer will be recruited from six UK secondary care sites. The number of participants and the duration of the trial will depend on toxicities observed and dose escalation decisions, utilising a TiTE-CRM statistical design. Treatment will constist of standard of care CRT with 45 Gy external beam radiotherapy given in 25 daily fractions over 5 weeks with weekly cisplatin 40mg/m2. This is followed by brachytherapy for which common schedules will be 28 Gy in 4 fractions high-dose-rate or 34 Gy in 2 fractions pulsed-dose-rate. Tolinapant will be administered in fixed dose capsules taken orally daily for seven consecutive days as an outpatient on alternate weeks (weeks 1, 3, 5) during chemoradiation. Dose levels for tolinapant which will be assessed are: 60 mg; 90 mg (starting level); 120 mg; 150 mg; 180 mg. Escalation will be guided by emerging safety data and decisions by the Safety Review Committee. DISCUSSION: If this trial determines a recommended phase II dose and shows tolinapant to be safe and effective in combination with CRT, it would warrant future phase trials. Ultimately, we hope to provide a synergistic treatment option for these patients to improve outcome. TRIAL REGISTRATIONS: EudraCT Number: 2021-006555-34 (issued 30th November 2021); ISRCTN18574865 (registered 30th August 2022).


Assuntos
Quimiorradioterapia , Neoplasias do Colo do Útero , Adulto , Feminino , Humanos , Quimiorradioterapia/métodos , Cisplatino/administração & dosagem , Cisplatino/uso terapêutico , Reino Unido , Neoplasias do Colo do Útero/terapia , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/patologia , Ensaios Clínicos Fase I como Assunto , Estudos Multicêntricos como Assunto
4.
JAMA Ophthalmol ; 142(6): 512-520, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38662399

RESUMO

Importance: Most neovascular age-related macular degeneration (nAMD) treatments involve long-term follow-up of disease activity. Home-monitoring would reduce the burden on patients and their caregivers and release clinic capacity. Objective: To evaluate 3 vision home-monitoring tests for patients to use to detect active nAMD compared with diagnosing active nAMD at hospital follow-up during the after-treatment monitoring phase. Design, Setting, and Participants: This was a diagnostic test accuracy study wherein the reference standard was detection of active nAMD by an ophthalmologist at hospital follow-up. The 3 home-monitoring tests evaluated included the following: (1) the KeepSight Journal (KSJ [International Macular and Retinal Foundation]), which contains paper-based near-vision tests presented as word puzzles, (2) the MyVisionTrack (mVT [Genentech]) vision-monitoring mobile app, viewed on an Apple mobile operating system-based device, and (3) the MultiBit (MBT [Visumetrics]) app, viewed on an Apple mobile operating system-based device. Participants were asked to test weekly; mVT and MBT scores were transmitted automatically, and KSJ scores were returned to the research office every 6 months. Raw scores between hospital follow-ups were summarized as averages. Patients were recruited from 6 UK hospital eye clinics and were 50 years and older with at least 1 eye first treated for active nAMD for at least 6 months or longer to a maximum of 42 months before approach. Participants were stratified by time since starting treatment. Study data were analyzed from May to September 2021. Exposures: The KSJ, mVT, and MBT were compared with the reference standard (in-hospital ophthalmologist examination). Main Outcomes and Measures: Estimated area under receiver operating characteristic curve (AUROC). The study had 90% power to detect a difference of 0.06, or 80% power to detect a difference of 0.05, if the AUROC for 2 tests was 0.75. Results: A total of 297 patients (mean [SD] age, 74.9 [6.6] years; 174 female [58.6%]) were included in the study. At least 1 hospital follow-up was available for 312 study eyes in 259 participants (1549 complete visits). Median (IQR) home-monitoring testing frequency was 3 (1-4) times per month. Estimated AUROC was less than 0.6 for all home-monitoring tests, and only the KSJ summary score was associated with lesion activity (odds ratio, 3.48; 95% CI, 1.09-11.13; P = .04). Conclusions and Relevance: Results suggest that no home-monitoring vision test evaluated provided satisfactory diagnostic accuracy to identify active nAMD diagnosed in hospital eye service follow-up clinics. Implementing any of these evaluated tests, with ophthalmologists only reviewing test positives, would mean most active lesions were missed, risking unnecessary sight loss.


Assuntos
Testes Visuais , Acuidade Visual , Degeneração Macular Exsudativa , Humanos , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Testes Visuais/instrumentação , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/tratamento farmacológico , Degeneração Macular Exsudativa/fisiopatologia , Idoso de 80 Anos ou mais , Curva ROC , Reprodutibilidade dos Testes , Aplicativos Móveis , Seguimentos , Inibidores da Angiogênese/uso terapêutico , Inibidores da Angiogênese/administração & dosagem , Tomografia de Coerência Óptica
5.
Transl Vis Sci Technol ; 13(3): 2, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427348

RESUMO

Purpose: To describe inequalities in the Monitoring for Neovascular Age-related Macular Degeneration Reactivation at Home (MONARCH) diagnostic test accuracy study for: recruitment; participants' ability to self-test; and adherence to testing using digital applications during follow-up. Methods: Home-monitoring vision tests included two tests implemented as software applications (apps: MyVisionTrack and MultiBit) on an iPod Touch device. Patients were provided with all hardware required to participate (iPod and MIFI device) and trained to use the apps. Regression models estimated associations of age, sex, Index of Multiple Deprivation, strata of time since first diagnosis, and baseline visual acuity at study entry on outcomes of willingness to participate, ability to perform tests, and adherence to weekly testing. Results: A minority of patients who were approached were willing-in-principle to participate. Increasing age was associated with being unwilling-in-principle to participate. Patients from the most deprived areas had a 47% decrease in odds of being willing compared to those from the middle quintile deprived areas (odds ratio, 0.53; 95% confidence interval = 0.32, 0.88). Increasing age and worse deprivation were not consistently associated either with ability to self-monitor with the index tests, or adherence to weekly testing. Conclusions: Associations of increasing age and worse deprivation index were associated with unwillingness-in-principle to participate despite the provision of hardware' highlighting the potential for inequality with interventions of the kind evaluated. Translational Relevance: The clear evidence of inequalities in participation should prompt future research on ways to encourage adoption of mobile health technologies by underserved populations.


Assuntos
Neovascularização de Coroide , Degeneração Macular , Telemedicina , Humanos , Idoso , Acuidade Visual , Degeneração Macular/diagnóstico , Degeneração Macular/epidemiologia
6.
BMJ Open ; 14(3): e077196, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38453199

RESUMO

OBJECTIVES: Remote monitoring of health has the potential to reduce the burden to patients of face-to-face appointments and make healthcare more efficient. Apps are available for patients to self-monitor vision at home, for example, to detect reactivation of age-related macular degeneration (AMD). Describing the challenges when implementing apps for self-monitoring of vision at home was an objective of the MONARCH study to evaluate two vision-monitoring apps on an iPod Touch (Multibit and MyVisionTrack). DESIGN: Diagnostic Test Accuracy study. SETTING: Six UK hospitals. METHODS: The study provides an example of the real-world implementation of such apps across health sectors in an older population. Challenges described include the following: (1) frequency and reason for incoming calls made to a helpline and outgoing calls made to participants; (2) frequency and duration of events responsible for the tests being unavailable; and (3) other technical and logistical challenges. RESULTS: Patients (n=297) in the study were familiar with technology; 252/296 (85%) had internet at home and 197/296 (67%) had used a smartphone. Nevertheless, 141 (46%) called the study helpline, more often than anticipated. Of 435 reasons for calling, all but 42 (10%) related to testing with the apps or hardware, which contributed to reduced adherence. The team made at least one call to 133 patients (44%) to investigate why data had not been transmitted. Multibit and MyVisionTrack apps were unavailable for 15 and 30 of 1318 testing days for reasons which were the responsibility of the app providers. Researchers also experienced technical challenges with a multiple device management system. Logistical challenges included regulations for transporting lithium-ion batteries and malfunctioning chargers. CONCLUSIONS: Implementation of similar technologies should incorporate a well-resourced helpline and build in additional training time for participants and troubleshooting time for staff. There should also be robust evidence that chosen technologies are fit for the intended purpose. TRIAL REGISTRATION NUMBER: ISRCTN79058224.


Assuntos
Degeneração Macular , Aplicativos Móveis , Telemedicina , Humanos , Smartphone , Degeneração Macular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA