Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 16: 153-62, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23182384

RESUMO

Ti-6Al-4V alloy with two kinds of open cellular structures of stochastic foam and reticulated mesh was fabricated by additive manufacturing (AM) using electron beam melting (EBM), and microstructure and mechanical properties of these samples with high porosity in the range of 62%∼92% were investigated. Optical observations found that the cell struts and ligaments consist of primary α' martensite. These cellular structures have comparable compressive strength (4∼113 MPa) and elastic modulus (0.2∼6.3 GPa) to those of trabecular and cortical bone. The regular mesh structures exhibit higher specific strength than other reported metallic foams under the condition of identical specific stiffness. During the compression, these EBM samples have a brittle response and undergo catastrophic failure after forming crush band at their peak loading. These bands have identical angle of ∼45° with compression axis for the regular reticulated meshes and such failure phenomenon was explained by considering the cell structure. Relative strength and density follow a linear relation as described by the well-known Gibson-Ashby model but its exponential factor is ∼2.2, which is relative higher than the idea value of 1.5 derived from the model.


Assuntos
Ligas/química , Elétrons , Fenômenos Mecânicos , Temperatura , Titânio/química , Módulo de Elasticidade , Dureza , Porosidade , Pós
2.
J Mech Behav Biomed Mater ; 4(7): 1396-411, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21783150

RESUMO

Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite with some residual α. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced ~2 µm in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness.


Assuntos
Artroplastia do Joelho , Materiais Biocompatíveis/química , Elétrons , Fenômenos Mecânicos , Próteses e Implantes , Desenho de Prótese/métodos , Ligas/química , Módulo de Elasticidade , Microscopia Eletrônica de Varredura , Modelos Moleculares , Conformação Molecular , Fenômenos Ópticos , Software , Difração de Raios X
3.
Philos Trans A Math Phys Eng Sci ; 368(1917): 1999-2032, 2010 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-20308113

RESUMO

In this paper, we examine prospects for the manufacture of patient-specific biomedical implants replacing hard tissues (bone), particularly knee and hip stems and large bone (femoral) intramedullary rods, using additive manufacturing (AM) by electron beam melting (EBM). Of particular interest is the fabrication of complex functional (biocompatible) mesh arrays. Mesh elements or unit cells can be divided into different regions in order to use different cell designs in different areas of the component to produce various or continually varying (functionally graded) mesh densities. Numerous design elements have been used to fabricate prototypes by AM using EBM of Ti-6Al-4V powders, where the densities have been compared with the elastic (Young) moduli determined by resonant frequency and damping analysis. Density optimization at the bone-implant interface can allow for bone ingrowth and cementless implant components. Computerized tomography (CT) scans of metal (aluminium alloy) foam have also allowed for the building of Ti-6Al-4V foams by embedding the digital-layered scans in computer-aided design or software models for EBM. Variations in mesh complexity and especially strut (or truss) dimensions alter the cooling and solidification rate, which alters the alpha-phase (hexagonal close-packed) microstructure by creating mixtures of alpha/alpha' (martensite) observed by optical and electron metallography. Microindentation hardness measurements are characteristic of these microstructures and microstructure mixtures (alpha/alpha') and sizes.


Assuntos
Materiais Biocompatíveis/química , Equipamentos e Provisões , Ligas , Fenômenos Biomecânicos , Engenharia Biomédica , Substitutos Ósseos/metabolismo , Osso e Ossos/metabolismo , Desenho de Equipamento , Humanos , Manufaturas , Teste de Materiais , Microscopia Eletrônica de Transmissão/métodos , Conformação Molecular , Desenho de Prótese , Titânio/química , Tomografia Computadorizada por Raios X/métodos
4.
J Mech Behav Biomed Mater ; 2(1): 20-32, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19627804

RESUMO

The microstructure and mechanical behavior of simple product geometries produced by layered manufacturing using the electron beam melting (EBM) process and the selective laser melting (SLM) process are compared with those characteristic of conventional wrought and cast products of Ti-6Al-4V. Microstructures are characterized utilizing optical metallography (OM), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and included alpha (hcp), beta (bcc) and alpha(') (hcp) martensite phase regimes which give rise to hardness variations ranging from HRC 37 to 57 and tensile strengths ranging from 0.9 to 1.45 GPa. The advantages and disadvantages of layered manufacturing utilizing initial powders in custom building of biomedical components by EBM and SLM in contrast to conventional manufacturing from Ti-6Al-4V wrought bar stock are discussed.


Assuntos
Engenharia Biomédica , Manufaturas , Fenômenos Mecânicos , Titânio/química , Ligas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA