Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Transfus Apher Sci ; 63(3): 103908, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519381

RESUMO

BACKGROUND: Pain is a side effect of Granulocyte-Colony Stimulating Factor (G-CSF) administration. This prospective study investigates various aspects including pain perception occurring in Peripheral Blood Stem Cell (PBSC) donors. MATERIALS AND METHODS: Related and unrelated PBSC donors were prospectively studied. Donors recorded pain symptoms during the four-day period of G-CSF administration using the McGill Pain Questionnaire, a Visual Analog Scale and a pain diary. RESULTS: There were 208 donors included, 102 (49%) related and 106 (51%) unrelated donors. Ninety-two percent of all reported the occurrence of pain. Moderate or severe pain was reported by 52%. No differences were found between related and unrelated donors. Pain occurred more often in females (p = 0.035). Relatively young donors (age 16-30 years) more frequently showed to have pain in comparison to older donors (>50 years) (p = 0.006). Musculoskeletal pain was most frequently distributed in the gluteal and lower back region (65-71%). Irrespective of the pain location, pain was most often described as nagging, annoying, however tolerable. Donors experiencing pain most on days of G-CSF administration, most frequently occurring during relaxation or at night. Sleep-mode was often affected. The use of paracetamol (acetaminophen) was sufficient for all but one donor. CONCLUSION: This is the first study to describe different aspects of pain associated with G-CSF administration in donors. Although the observed pain was tolerable, it should never be neglected. Knowledge derived from this study is of use for staff members involved in donor information and care management.


Assuntos
Células-Tronco de Sangue Periférico , Humanos , Feminino , Masculino , Adulto , Adolescente , Pessoa de Meia-Idade , Estudos Prospectivos , Dor , Adulto Jovem , Manejo da Dor/métodos , Fator Estimulador de Colônias de Granulócitos/uso terapêutico , Doadores de Sangue
2.
Transfusion ; 64(5): 854-865, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38385649

RESUMO

BACKGROUND: Many blood banks use upper age limits for donors out of concern for a higher donor complication rate in older donors. Experienced donors are known to have lower donor complication rates, and older donors are often more experienced, confounding the effect of age on donor complication rate. STUDY DESIGN AND METHODS: We studied donor complication rates in whole blood, plasma, and plateletpheresis donors from 2012 to 2022. Donor complication rates were compared between age groups in inexperienced (<20th donation) and experienced (≥20th donation) donors. In addition to this direct comparison, we made use of logistic regression with finer-grained experience groups, to further quantify the effects of age, experience and other factors on donor complication rate. RESULTS: While overall rate of vasovagal reaction was lower, rate of moderate/severe vasovagal syncope was highest in 70-79 year donors, however, only reached significance for plasma donors. Furthermore, rates of failed stab were highest in this age group. Hematoma rate showed a U-shaped pattern with regard to age, where the rate was not higher in the 70-79 year age group than in the 18-23 year age group. Pain decreased with age, however, rates were higher in the 70-79 year age group than in the 65-69 year age group. DISCUSSION: When properly accounting for donor experience, donor complication rate profiles clearly change with age. The increased risk for moderate/severe vasovagal syncope in older donors should be clearly communicated. Extra caution is needed if these donors are accepted for first-time donations.


Assuntos
Doadores de Sangue , Síncope Vasovagal , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Síncope Vasovagal/etiologia , Síncope Vasovagal/epidemiologia , Masculino , Feminino , Fatores Etários , Adolescente , Adulto Jovem , Plaquetoferese/efeitos adversos , Hematoma/etiologia , Hematoma/epidemiologia , Plasma , Plaquetas
3.
Transfusion ; 64(4): 572-577, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38380832

RESUMO

INTRODUCTION: Sanquin donor medicine department is informed when donations or their components are rejected. This can occur isolated or frequently. It is undesirable because the donations cannot be used and there may be an underlying medical cause. Based on regional approaches, a uniform procedure was developed. METHODS: Information about whole blood, plasma- plateletpheresis donations from which one or more components were rejected for filtration time (>2 h), hemolysis or clots were extracted from blood bank information system. After rejection of two successive components or donations or total ≥3 the donor is contacted. Depending on the medical history and investigation by the family doctor, the donor carrier is re-evaluated. We looked for the causes of the discarded products and performed a survey among blood services regarding polices with discarded products. RESULTS: One or more components from 1742 of about 2.2 million successful donations (0.08%) were rejected. The highest percentage of rejection was seen in plateletpheresis (1.5%), all for clots. No underlying medical causes were found. 24 whole blood donors were found to have sickle cell trait (SCT) and were permanently deferred. The policies for follow-up after discarded products or acceptance of SCT donors vary between the 16 blood banks. Six organizations do not follow-up donors and seven accept SCT for blood or plasma donation. CONCLUSION: Informing donors with repeated discarded products avoids the non-use of donations. Causes of repeated discarded products can be found by follow-up of donors. The results of the survey indicate a large discrepancy in policies applied worldwide.


Assuntos
Hemólise , Plaquetoferese , Humanos , Seguimentos , Doadores de Sangue , Bancos de Sangue
4.
Transfusion ; 63(12): 2273-2280, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37909172

RESUMO

INTRODUCTION: In 2018, platelet (PLT) additive solution-E (PAS-E) was introduced. The implementation of PAS-E was expected to diminish the number of allergic reactions in recipients following a PLT transfusion. Here, we evaluated the efficacy and safety of transfusions with PLTs stored in PAS-E. STUDY DESIGN AND METHODS: After implementation of PAS-E, data were collected from 2 cohorts of patients with hematological disorders as well as oncology patients, receiving PLTs in PAS-E. A similar patient group in a recent RCT, receiving PLTs in plasma, was used as a historical control group for both cohorts. Endpoints were corrected count increments (CCIs), bleeding scores (only reported in cohort 1), and the incidence of adverse reactions. RESULTS: In cohort 1, the mean 1-h CCI was 14.3 ± 6.9, and the 24-h CCI was 8.7 ± 5.6. In cohort 2, the 1-h CCI was 11.6 ± 7.8 and the 24-h CCI was 7.0 ± 6.1. In the control group, the 1-h CCI was 15.4 ± 5.5 and 24-h CCI 8.7 ± 4.8. Bleeding complications of WHO grade ≥2 occurred in 40% of patients in cohort 1 compared to 44% in plasma PCs. The incidence of adverse reactions was 1.2% in the two PAS-E cohorts, compared to 3.0% in plasma PCs. National hemovigilance data showed a significant reduction in allergic reactions with PAS-E PC transfusions as compared to plasma PCs with an odds ratio of 0.46 (CI 95% 0.37-0.58). CONCLUSION: The CCIs of PLTs in PAS-E were decreased compared to plasma PCs, but clinically acceptable. Allergic transfusion reactions were decreased in PAS-E PCs compared to plasma PCs.


Assuntos
Hipersensibilidade , Reação Transfusional , Humanos , Plaquetas , Transfusão de Plaquetas/efeitos adversos , Segurança do Sangue , Reação Transfusional/etiologia , Preservação de Sangue , Hipersensibilidade/etiologia
5.
Transfusion ; 63(6): 1161-1171, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37060282

RESUMO

BACKGROUND: Pulmonary complications of blood transfusion, including transfusion-related acute lung injury (TRALI), transfusion-associated circulatory overload (TACO), and transfusion-associated dyspnea, are generally underdiagnosed and under-reported. The international TRALI and TACO definitions have recently been updated. Currently, no standardized pulmonary transfusion reaction reporting form exists and most of the hemovigilance forms have not yet incorporated the updated definitions. We developed a harmonized reporting form, aimed at improved data collection on pulmonary transfusion reactions for hemovigilance and research purposes by developing a standardized model reporting form and flowchart. MATERIALS AND METHODS: Using a modified Delphi method among an international, multidisciplinary panel of 24 hemovigilance experts, detailed recommendations were developed for a standardized model reporting form for pulmonary complications of blood transfusion. Two Delphi rounds, including scoring systems, took place and several subsequent meetings were held to discuss issues and obtain consensus. Additionally, a flowchart was developed incorporating recently published redefinitions of pulmonary transfusion reactions. RESULTS: In total, 17 participants completed the first questionnaire (70.8% response rate) and 14 participants completed the second questionnaire (58.3% response rate). According to the results from the questionnaires, the standardized model reporting form was divided into various subcategories: general information, patient history and transfusion characteristics, reaction details, investigations, treatment and supportive care, narrative, and transfused product. CONCLUSION: In this article, we present the recommendations from a global group of experts in the hemovigilance field. The standardized model reporting form and flowchart provide an initiative that may improve data collected to address pulmonary transfusion reactions.


Assuntos
Reação Transfusional , Lesão Pulmonar Aguda Relacionada à Transfusão , Humanos , Lesão Pulmonar Aguda Relacionada à Transfusão/epidemiologia , Lesão Pulmonar Aguda Relacionada à Transfusão/etiologia , Design de Software , Transfusão de Sangue , Pulmão , Reação Transfusional/complicações
6.
Transfusion ; 62(3): 594-599, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35174882

RESUMO

BACKGROUND: Antibody-mediated transfusion-related acute lung injury (TRALI) is caused by donor HLA or HNA antibodies in plasma-containing products. In the Netherlands 55,000 units of solvent/detergent plasma (SDP), a pooled plasma product, are transfused yearly. It's produced by combining plasma from hundreds of donors, diluting harmful antibodies. Due to a lack of reported cases following implementation, some have labeled SDP as "TRALI safe". STUDY DESIGN AND METHODS: Pulmonary transfusion reactions involving SDP reported to the Dutch national hemovigilance network in 2016-2019 were reviewed. Reporting hospitals were contacted for additional information, cases with TRALI and imputability definite, probable, or possible were included and informed consent was sought. RESULTS: A total of three TRALI and nine TACO cases were reported involving SDP. The imputability of one TRALI case was revised from possible to unlikely and excluded; in one case no informed consent was obtained. We present a case description of TRALI following SDP transfusion in a 69-year-old male, 3 days following endovascular aortic aneurysm repair. The patient received one unit of SDP to correct a heparin-induced coagulopathy, prior to removal of a spinal catheter post-operatively. Within five hours he developed hypoxemic respiratory failure requiring intubation, hypotension, bilateral chest infiltrates, and leucopenia. The patient made a full recovery. CONCLUSION: This case of TRALI, following transfusion of a single unit of SDP to a patient without ARDS risk factors, demonstrates that TRALI can occur with this product. Clinicians should remain vigilant and continue to report suspected cases, to help further understanding of SDP-associated TRALI.


Assuntos
Lesão Pulmonar Aguda , Reação Transfusional , Lesão Pulmonar Aguda Relacionada à Transfusão , Lesão Pulmonar Aguda/etiologia , Idoso , Anticorpos , Detergentes , Humanos , Masculino , Solventes/efeitos adversos , Reação Transfusional/complicações , Lesão Pulmonar Aguda Relacionada à Transfusão/complicações
7.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
8.
Vox Sang ; 117(3): 313-320, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34396539

RESUMO

BACKGROUND AND OBJECTIVES: The EPISoDe (Experience Success in Donation) study investigated the effect of interventions on self-reported vasovagal reactions (VVRs) in first-time and novice (second to fourth donation) whole blood donors aged ≤30 years, demonstrating a 23% reduction of VVR from water drinking shortly before donation in the novice donors. Because donation experience and complications affect donor retention, we analysed intervention group donors' return for subsequent donation, a predefined secondary outcome. MATERIALS AND METHODS: The interventions were as follows: 330 ml water, 500 ml water, ball squeezing before phlebotomy (placebo) and a control group. All donors received an online questionnaire about their experience within a week after donation. In the Netherlands, eligible donors are invited at least yearly depending on hospitals' needs. We analysed attendances within 421 days through return percentages and binomial logistic regression. RESULTS: Of the 8300 EPISoDe participants, 6538 (78.8%) returned within 421 days. Return did not differ between the two water groups, whereas odds for return were significantly higher in both water and placebo intervention donors compared to the control group (odds ratio [OR] 1.14, 95% confidence interval [CI] 1.00-1.29 and 1.22, 1.05-1.43, respectively) after adjustment for occurrence of VVR, unsuccessful collection, gender and donation history. Staff-recorded or self-reported VVR at index donation was associated with reduced odds for return (OR 0.47, 95% CI 0.37-0.60 and OR 0.53, 95% CI 0.46-0.61, respectively). CONCLUSION: In this cohort of younger inexperienced blood donors, 78.8% returned for subsequent donation. Donors who received an active study intervention, either water or placebo, were more likely to return than control group donors.


Assuntos
Síncope Vasovagal , Adulto , Doadores de Sangue , Humanos , Flebotomia/efeitos adversos , Autorrelato , Inquéritos e Questionários , Síncope Vasovagal/epidemiologia , Síncope Vasovagal/etiologia , Síncope Vasovagal/prevenção & controle
9.
Br J Haematol ; 195(5): 681-688, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34490619

RESUMO

Transfusion-associated graft-versus-host disease (TA-GVHD) is a rare, commonly fatal complication of transfusion preventable by irradiation of blood units. The revision of the Dutch transfusion guideline addressed the question whether irradiation is still necessary if blood components are prestorage leukodepleted. We searched for published cases of TA-GVHD following transfusion of prestorage leukodepleted blood and through contacting haemovigilance systems. Six presumed cases were found, dating from 1998 to 2013. Four out of six patients had received one or more non-irradiated units despite recognised indications for irradiated blood components. In the countries providing information, over 50 million prestorage leukodepleted, non-irradiated, non-pathogen-reduced cellular components were transfused in a 10-year period. Potential benefits of lifting indications for irradiation were considered. These include reduced irradiation costs (€ 1.5 million annually in the Netherlands) and less donor exposure for neonates. Findings were presented in an invitational expert meeting. Recommendations linked to human leukocyte antigen similarity between donor and recipient or intra-uterine transfusion were left unchanged. Indications linked to long-lasting deep T-cell suppression were defined with durations of 6 or 12 months after end of treatment (e.g. autologous or allogeneic stem cell transplantation). Need for continued alertness to TA-GVHD and haemovigilance reporting of erroneous non-irradiated transfusions was emphasised.


Assuntos
Transfusão de Componentes Sanguíneos/efeitos adversos , Preservação de Sangue , Reação Transfusional/etiologia , Reação Transfusional/prevenção & controle , Transfusão de Componentes Sanguíneos/métodos , Preservação de Sangue/efeitos adversos , Preservação de Sangue/métodos , Transfusão de Sangue , Humanos , Procedimentos de Redução de Leucócitos/métodos , Países Baixos/epidemiologia
10.
Transfusion ; 61(6): 1780-1788, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33665853

RESUMO

BACKGROUND: Severe blood donor adverse events are rare, but due to their rarity studying them can be difficult. To get an accurate estimate of their frequency and rate in the donor population it may be necessary to combine donation data across countries. STUDY DESIGN AND METHODS: International blood collection organizations (BCOs) provided data on rare/severe donor reactions as well as denominator information for their donor populations from 2015 to 2017. Donor reactions were classified using standardized definitions. RESULTS: BCOs from six countries provided reaction data for more than 22 million donations. A total of 480 rare reactions were reported of which 76.7% were imputed as definite and 11% probable. Rates of rare reactions were higher in females and first-time donors. Systemic rare reactions were the most common reaction type, accounting for over three quarters of reactions reported. Of systemic reactions, vasovagal reactions with loss of consciousness and injury or off-site (n = 350) made up the majority and occurred 1.53 per 100,000 donations. For the 22.3% that were localized reactions, the majority of these were cellulitis (n = 71, 0.31 per 100,000 donations) followed by deep venous thrombosis (n = 21, 0.09 per 100,000 donations). CONCLUSION: Pulling together data from multiple BCOs across countries allows for a better understanding of rare reactions, such as vasovagal reaction with injury or cellulitis, and for generating a reliable incidence rate for air embolism or compartment syndrome. However, gaps remain due to missing elements such as unknown donor status or location of reaction.


Assuntos
Doadores de Sangue , Celulite (Flegmão)/etiologia , Síncope Vasovagal/etiologia , Trombose Venosa/etiologia , Adolescente , Adulto , Idoso , Remoção de Componentes Sanguíneos/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Adulto Jovem
11.
Cell Tissue Bank ; 22(2): 191-197, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32902671

RESUMO

Annually more than 21,000 volunteer unrelated hematopoietic stem cell donations are performed worldwide for patients with life-threatening diseases such as acute leukaemia. Donor safety issues and donor protection is one of the top priorities for the international cooperation of unrelated hematopoietic stem cell donor registries represented by the World Marrow Donor Association (WMDA). With this new global reporting system for serious events and adverse reactions (S(P)EARs), the WMDA aims to become the global leading online platform for hematopoietic stem cell donor organisations to report their S(P)EARs from both unrelated and family donors. Software developer Cogapp developed the platform using a Knack environment based on requirements of experienced reporters and reviewers. On July 1st WMDA launched a robust online reporting system for S(P)EARs in order to provide accurate information about potential risks to donors. The collected data about S(P)EARs occurring in donors will be analysed and used to provide statistics on the type of reports being submitted and to put in place best practices to mitigate such effects and occurrences. Via the annual S(P)EAR reports the results will be disseminated worldwide.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Células-Tronco Hematopoéticas , Humanos , Sistema de Registros , Doadores de Tecidos , Transplante Homólogo
12.
Vox Sang ; 116(6): 628-636, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33278040

RESUMO

BACKGROUND AND OBJECTIVES: The International Haemovigilance Network collects aggregate data on complications of blood donation from member haemovigilance systems (HVS). We analysed the data collected in 2006-2016 in order to learn from it and consider future improvements. MATERIALS AND METHODS: National HVS entered annual data on donation complications and on annual whole blood and apheresis donations in the 'ISTARE' (International Surveillance of Transfusion Adverse Reactions and Events) online database. We calculated national and aggregate donation complication rates. RESULTS: Twenty-four HVS provided data for 138 country years (CY; median 7 CY, IQR 2-8), covering 155 M donations. The overall complication rate was 6·3/1000 donations and the median country rate 3·2/1000 (IQR 1·1-10·1). Overall and severe complication rates varied considerably between HVS. Vasovagal reactions (VVR) were most commonly reported: 4·6/1000 donations, median country rate 3·1/1000 donations (IQR 0·6-7·7). Rare complications included generalized allergic reaction (0·10/100 000) and major blood vessel injury (category available since 2015; 0·12/100 000). Eighteen HVS reported complications of whole blood donation (WBD) and apheresis separately (89 CY, 101·6 M WBD and 26·3 M apheresis donations). The median country VVR rate was 3·4/1000 WBD (IQR 1·0-9·1) and 1·5/1000 apheresis donations (1·0-4·2). Rates of venepuncture-related complications tended to be higher for apheresis: the median country rate of reported haematomas was 0·39/1000 WBD (IQR 0·31-1·2) vs. 4·2/1000 apheresis donations (0·69-5·6). CONCLUSION: International reporting allows HVS to study rates of blood donation complications and capture information about very rare events. The present variability of reporting and severity assessment hampers comparisons between HVS and requires further work.


Assuntos
Remoção de Componentes Sanguíneos , Doadores de Sangue , Síncope Vasovagal , Remoção de Componentes Sanguíneos/efeitos adversos , Segurança do Sangue , Humanos , Flebotomia , Síncope Vasovagal/epidemiologia , Síncope Vasovagal/etiologia
13.
Transfusion ; 60(6): 1231-1242, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32452048

RESUMO

BACKGROUND: Uniform and consistent reporting and comparison of donor adverse events (DAEs) and severity are well-recognized challenges for donor hemovigilance (DHV). While the 2014 Standard for Surveillance of Complications Related to Blood Donation (SSCRBD), developed by hemovigilance experts from AABB, the International Society of Blood Transfusion, and International Hemovigilance Network, established the DAE definitions, no specific guidelines were provided to grade severity. A group of subject matter experts developed the Severity Grading Tool for Blood Donor Adverse Events (SGT) to enhance objective assignment of severity and conducted a study to validate the tool. STUDY DESIGN AND METHODS: Between January 8, 2019, and February 28, 2019, participants graded severity of 32 cases (34 DAEs) using the SGT. Comments boxes allowed participants to provide rationale for selecting a severity grade for each case. Agreement with expert grading among study participants was evaluated using percentage agreement. Inter-rater reliability was evaluated by Kendall's coefficient of concordance (W). The final SGT was revised based on validation study results and feedback received. RESULTS: The overall agreement was almost perfect with W = 0.84 (confidence interval [CI], 0.78-0.90). Of 34 DAEs, respondent agreement with expert grading of more than 90% was reached for 18 DAEs, 80% to 90% for six DAEs, 70% to 80% for six DAEs, and less than 70% for four DAEs. CONCLUSION: The development and validation of a uniform SGT with objective criteria for assigning severity of DAEs used together with standard reaction definitions will provide opportunities for comparison between blood centers and systems to enhance the field of DHV.


Assuntos
Segurança do Sangue , Transfusão de Sangue , Índice de Gravidade de Doença , Reação Transfusional/diagnóstico , Feminino , Humanos , Masculino
14.
Haematologica ; 105(4): 1158-1165, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31273090

RESUMO

Plasma transfusion is indicated for replenishment of coagulative proteins to stop or prevent bleeding. In 2014, the Netherlands switched from using ~300mL fresh frozen plasma (FFP) units to using 200mL Omniplasma, a solvent/detergent treated pooled plasma (SD plasma), units. We evaluated the effect of the introduction of SD plasma on clinical plasma use, associated bleeding, and transfusion reaction incidences. Using diagnostic data from six Dutch hospitals, national blood bank data, and national hemovigilance data for 2011 to 2017, we compared the plasma/red blood cell (RBC) units ratio (f) and the mean number of plasma and RBC units transfused for FFP (~300mL) and SD plasma (200mL) for various patient groups, and calculated odds ratios comparing their associated transfusion reaction risks. Analyzing 13,910 transfusion episodes, the difference (Δf = fSD - fFFP) in mean plasma/RBC ratio (f) was negligible (Δfentire_cohort = 0.01 [95% confidence interval (CI): -0.02 - 0.05]; P=0.48). SD plasma was associated with fewer RBC units transfused per episode in gynecological (difference of mean number of units -1.66 [95% CI: -2.72, -0.61]) and aneurysm (-0.97 [-1.59, -0.35]) patients. SD plasma was further associated with fewer anaphylactic reactions than FFP (odds ratio 0.37 [0.18, 0.77; P<0.01]) while the differences for most transfusion reactions were not statistically significant. SD plasma units, despite being one third smaller in volume than FFP units, are not associated with a higher plasma/RBC ratio. SD plasma is associated with fewer anaphylactic reactions than FFP plasma/RBC units ratio.


Assuntos
Plasma , Reação Transfusional , Transfusão de Componentes Sanguíneos/efeitos adversos , Detergentes , Transfusão de Eritrócitos , Humanos , Países Baixos/epidemiologia , Estudos Retrospectivos , Solventes
15.
Transfusion ; 59(10): 3140-3145, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31503334

RESUMO

BACKGROUND: Reports on the clinical consequences of longer storage time of platelet concentrates are contradictory. The objective of this study was to assess whether longer storage times are associated with a higher risk of transfusion reactions. STUDY DESIGN AND METHODS: We gathered storage times of pooled platelet concentrates related to transfusion reactions reported to the national hemovigilance office from 2004 to 2015. These were combined with storage times of platelet concentrates in the reference population to compare incidences of transfusion-associated circulatory overload, transfusion-related acute lung injury, allergic reactions, febrile nonhemolytic reactions, and "other" reactions between storage time categories. RESULTS: A total of 567,053 platelet concentrates and 1870 transfusion reactions were analyzed. Among platelet additive solution (PAS)-B platelet recipients, the odds ratio of a storage time of 4 to 5 days compared to 1 to 3 days was 1.60 (95% confidence interval [CI], 1.17-2.18) for allergic, and 1.47 (1.09-1.98) for febrile reactions. For PAS-C platelet recipients, the odds ratio for allergic reactions was 3.78 (95% CI, 1.31-10.9) for 4 to 5 days, and 4.57 (95% CI, 1.57-13.4) for 6- to 7-day-old platelets when compared to 1- to 3-day-old units. In all other studied reaction types, no statistically significant association was observed in platelets in plasma, PAS-B, and PAS-C. CONCLUSIONS: In plasma platelets, longer storage time was not associated with a higher incidence of transfusion reactions. In PAS platelets, longer storage time was associated with higher transfusion reaction incidences, in particular for allergic reactions with both PAS fluids and febrile reactions with PAS-B. This indicates that the effect of storage time is different for different reaction types and depends on the storage fluid.


Assuntos
Plaquetas , Preservação de Sangue , Bases de Dados Factuais , Hemólise , Hipersensibilidade/epidemiologia , Transfusão de Plaquetas , Lesão Pulmonar Aguda Relacionada à Transfusão/epidemiologia , Feminino , Humanos , Hipersensibilidade/etiologia , Masculino , Estudos Retrospectivos , Fatores de Tempo
17.
Lancet Haematol ; 6(7): e350-e358, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31080132

RESUMO

BACKGROUND: Transfusion-associated circulatory overload (TACO) is a major cause of transfusion-related morbidity and mortality in countries with well developed transfusion services. The International Society of Blood Transfusion, the International Haemovigilance Network, and AABB (formerly American Association of Blood Banks), have developed and validated a revised definition of TACO. METHODS: International Haemovigilance Network-member haemovigilance systems (Australia, Austria, Denmark, Finland, Greece, India, Ireland, Italy, Japan, Malta, Netherlands, New Zealand, Norway, Slovenia, United Kingdom and United States) provided cases of respiratory complications categorised by their systems, including clinical parameters listed in the 2017 draft definition (part 1). Individual transfusion professionals were then invited to assess 24 case descriptions according to the draft definition (part 2). Positive and negative agreement and inter-rater agreement (κ) were calculated. Based on validation results, cases were reanalysed and slight adjustments made to yield the final 2018 TACO definition. FINDINGS: In part 1, 16 (44%) of 36 haemovigilance systems provided 178 cases, including 126 TACO cases. By use of the 2018 definition, 96 (76%) of 126 cases of TACO were in positive agreement. 19 (37%) of 52 cases were recognised as non-TACO respiratory complications. In part 2 (47 experts from 20 countries), moderate all-case agreement (κ=0·43) and TACO-specific agreement (κ=0·54) were observed. Excluding cases missing some clinical information (eg, N terminal pro-brain natriuretic peptide, distinctive chest x-ray findings, and relationship with existing respiratory co-morbidities like pneumonia and chronic obstructive pulmonary disease) improved all-case agreement to κ=0·50 (moderate) and κ=0·65 (good) for TACO cases. INTERPRETATION: The two-part validation exercise showed that the revised 2018 TACO surveillance case definition captures 76% of cases endorsed as TACO by participating haemovigilance systems. This definition can become the basis for internationally consistent surveillance reporting and contribute towards increased awareness and mitigation of TACO. Further research will require reporting more complete clinical information to haemovigilance systems and should focus on improved distinction between TACO and other transfusion respiratory complications. FUNDING: International Society of Blood Transfusion, International Haemovigilance Network, and AABB.


Assuntos
Reação Transfusional/diagnóstico , Segurança do Sangue , Transfusão de Sangue , Humanos , Fatores de Risco , Sociedades Científicas , Inquéritos e Questionários , Reação Transfusional/classificação
18.
Transfusion ; 59(2): 555-565, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30508293

RESUMO

BACKGROUND: Complications of donation reduce donor return. Younger and less experienced donors are more likely to experience vasovagal-type reactions (VVR). A water drink of approximately 500 mL shortly before donation may reduce VVR, but the effect of a smaller volume of water has not been investigated. STUDY DESIGN AND METHODS: A placebo-controlled comparative study was conducted among donors < 30 years who attended for a 1st-4th whole blood (WB) donation. Collection centers were assigned to offer one of three interventions: 500 mL water drink, 330 mL water drink, or a placebo intervention consisting of pre-donation arm exercise. Within 7 days after attending, participants received an electronic questionnaire about possible symptoms during and after donation. In additional centers, control donors were recruited, who only received standard care and were also sent the questionnaire. Self-reported VVR and other complications were evaluated in all groups. RESULTS: Out of 8,300 participating donors, 6,921 (83%) returned the questionnaire. Overall, 18.5% of responding donors reported moderate or worse VVR symptoms. In 2nd-4th time donors, both water volumes decreased the odds of a VVR compared to standard care controls (OR500ml 0.75, 95% CI 0.59-0.94; OR330ml 0.73, 0.58-0.91; adjusted combined OR 0.77, 0.64-0.94). There was no effect in new donors or the placebo group compared to controls. CONCLUSION: In young donors making their 2nd-4th WB donation, drinking water was associated with 23% fewer VVR with no difference between 330 and 500 mL. This decrease was not found in the placebo group. The findings support advocating drinking water for the prevention of VVR.


Assuntos
Doadores de Sangue , Água Potável/administração & dosagem , Inquéritos e Questionários , Síncope Vasovagal/prevenção & controle , Adolescente , Adulto , Pressão Sanguínea , Feminino , Humanos , Masculino , Síncope Vasovagal/etiologia , Síncope Vasovagal/fisiopatologia
19.
Transfusion ; 58(4): 1021-1027, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29405304

RESUMO

BACKGROUND: Platelets (PLTs) stored in PLT additive solution (PAS) are associated with fewer allergic reactions than plasma-stored PLTs. However, earlier studies could not provide conclusive evidence on febrile reactions and did not analyze other transfusion reactions separately due to limited sample size. We therefore compared incidences of all transfusion reactions of PAS-B-PLTs, PAS-C-PLTs, and plasma-PLTs. STUDY DESIGN AND METHODS: In this observational study, all transfusion reactions reported to the national hemovigilance office of the Netherlands from 2006 to 2015 were included. RESULTS: During the study period, a total of 2407 transfusion reactions after PLT transfusions were reported. In that period 553,267 pooled buffy coat-derived PLT units were issued, of which 83,884 were stored in PAS-B, 45,728 in PAS-C, and 423,655 in plasma. Regarding transfusion-related circulatory overload, transfusion-related acute lung injury, and "other reactions" no significant differences were observed between the PLT products. When PAS-B-PLT transfusions were compared to plasma-PLT transfusions, the overall relative risk (RR; 95% confidence interval [CI]) of transfusion reactions was 0.99 (0.88-1.11); for allergic and febrile nonhemolytic transfusion reactions (FNHTRs) it was 0.66 (0.55-0.80) and 1.54 (1.27-1.86), respectively. When PAS-C-PLTs were compared to plasma-PLTs, the RR (95% CI) was 0.56 (0.46-0.68) for all transfusion reactions, 0.38 (0.28-0.52) for allergic reactions, and 0.82 (0.59-1.13) for FNHTRs. When PAS-C-PLTs were compared to PAS-B-PLTs, for all reactions the RR (95% CI) was 0.56 (0.45-0.70) for allergic reactions 0.58 (0.40-0.82), and for FNHTRs 0.53 (0.37-0.75). CONCLUSIONS: PAS-C-PLTs are associated with fewer transfusion reactions compared to plasma-PLTs and compared to PAS-B-PLTs.


Assuntos
Plaquetas/efeitos dos fármacos , Preservação de Sangue/métodos , Soluções para Preservação de Órgãos/farmacologia , Plasma , Transfusão de Plaquetas/efeitos adversos , Reação Transfusional/etiologia , Buffy Coat/citologia , Segurança do Sangue , Humanos , Hipersensibilidade/epidemiologia , Hipersensibilidade/etiologia , Países Baixos/epidemiologia , Razão de Chances , Estudos Retrospectivos , Reação Transfusional/epidemiologia
20.
Br J Haematol ; 180(5): 727-734, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29318576

RESUMO

Plasma transfusions may result in transfusion reactions. We used the International Surveillance of Transfusion-Associated Reactions and Events (ISTARE) database, containing yearly reported national annual aggregate data on transfusion reactions from participating countries, to investigate risks of plasma transfusion reactions and compare transfusion reaction risks for different plasma types. We calculated risks for plasma transfusion reactions and compared transfusion reaction risks between plasma types using random effects regression on repeated measures. The ISTARE database contains data from 23 countries, reporting units issued and/or transfused and transfusion reactions observed for some portion of 7 years (2006-2012). Interquartile ranges (IQRs) of plasma transfusion reaction risks were: allergic reactions (5·6-72·2 reactions/105 units transfused); febrile non-haemolytic transfusion reactions (0-9·1); transfusion-associated circulatory overload (0-1·9); transfusion related acute lung injury (TRALI) (0-1·2); and hypotensive reactions (0-0·6). Apheresis plasma was associated with more allergic reactions [odds ratio (OR) = 1·29 (95% confidence interval: 1·19-1·40)] and hypotensive reactions [OR = 2·17 (1·38-3·41)] than whole blood-derived plasma. Pathogen-inactivated plasma was associated with fewer transfusion reactions than untreated plasma.


Assuntos
Transfusão de Componentes Sanguíneos/efeitos adversos , Segurança do Sangue/estatística & dados numéricos , Plasma , Reação Transfusional/etiologia , Remoção de Componentes Sanguíneos/efeitos adversos , Doadores de Sangue/estatística & dados numéricos , Feminino , Humanos , Masculino , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA