Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 60(4): 939-946, 2021 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-33779724

RESUMO

OBJECTIVES: The aim of this study was to investigate the long-term outcomes following right ventricle-to-pulmonary artery (RV-to-PA) conduit insertion of Medtronic Freestyle® porcine valve (MFV) or pulmonary allograft valve (PAV) in adult patients with congenital heart disease. METHODS: Retrospective medical record review of consecutive RV-to-PA conduit insertion, using either PAV or MFV from 1991 to 2017. Perioperative data and clinic reports were collected. Cause and date of death were obtained from the Australian National Death Index to obtain survival function. RESULTS: In total, 232 patients (median age 31.5 years, interquartile range 25-41 years) underwent RV-to-PA conduit insertion (PAV = 84 and MFV = 148) and were eligible for inclusion [63.8% tetralogy of Fallot (TOF); 11.6% congenital pulmonary stenosis (PS); 24.6% other diagnoses]. The overall median follow-up time was 9.1 years (interquartile range 5.3-12.6 years). The mean gradient was 11.8 ± 7.1 mmHg in PAV and 16.6 ± 9.6 mmHg in MFV patients. Congenital PS patients had 100% survival at 20 years, TOF patients at 5, 10, 15 and 20 years had 99%, 97%, 96% and 96% survival, respectively. Patients with other primary diagnoses at 5, 10, 15 and 20 years had 93%, 91%, 87% and 87% respectively. Freedom from reintervention did not differ significantly at 5 and 10 years between pulmonary allograft (98.6%, 98.6%) and Freestyle® porcine bioprosthesis (97.5%, 93%). CONCLUSIONS: Both valves perform equally well with regard to patients' freedom from reoperation, although transvalvular gradient was higher for Freestyle® patients. Congenital PS and TOF patients had better survival than patients with other primary diagnoses.


Assuntos
Bioprótese , Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Próteses Valvulares Cardíacas , Valva Pulmonar , Adulto , Animais , Austrália , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Análise de Sobrevida , Suínos , Resultado do Tratamento
2.
World J Pediatr Congenit Heart Surg ; 10(5): 543-551, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31496405

RESUMO

BACKGROUND: Following corrective surgery in infancy/childhood for tetralogy of Fallot (TOF) or its variants, patients may eventually require pulmonary valve replacement (PVR). Debate remains over which valve is best. We compared outcomes of the Medtronic Freestyle valve with that of the pulmonary allograft valve following PVR. METHODS: A retrospective study was undertaken from a single surgical practice of adult patients undergoing elective PVR between April 1993 and March 2017. The choice of valve was at the surgeon's discretion. There was a trend toward the almost exclusive use of the more readily available Medtronic Freestyle valve since 2008. RESULTS: One hundred fifty consecutive patients undergoing 152 elective PVRs were reviewed. Their mean age was 33.8 years. Ninety-four patients had a Medtronic Freestyle valve, while 58 had a pulmonary allograft valve. There were no operative or 30-day mortality. The freedom from reintervention at 5 and 10 years was 98% and 98% for the pulmonary allograft and 99% and 89% for the Medtronic Freestyle. There was no significant difference in the rate of reintervention, though this was colored by higher pulmonary gradients across the Medtronic Freestyle despite its shorter follow-up. CONCLUSIONS: Pulmonary valve replacement following previous surgical repair of TOF or its variants was found to be safe with no significant differences in mortality or reintervention between either valve. Although the Medtronic Freestyle valve had a greater tendency toward pulmonary stenosis, additional follow-up is needed to further document its long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Valva Pulmonar/transplante , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Aloenxertos , Procedimentos Cirúrgicos Cardíacos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Reimplante , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA