Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081238

RESUMO

The performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium-tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

2.
Sci Rep ; 13(1): 2227, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36755138

RESUMO

Contact and projection electron radiography of static targets was demonstrated using a laser-plasma accelerator driven by a kilojoule, picosecond-class laser as a source of relativistic electrons with an average energy of 20 MeV. Objects with areal densities as high as 7.7 g/cm2 were probed in materials ranging from plastic to tungsten, and radiographs with resolution as good as 90 µm were produced. The effects of electric fields produced by the laser ablation of the radiography objects were observed and are well described by an analytic expression relating imaging magnification change to electric-field strength.

3.
Rev Sci Instrum ; 92(3): 033508, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820056

RESUMO

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

4.
Rev Sci Instrum ; 89(10): 10I127, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399819

RESUMO

The current construction of a new nuclear-imaging view at the National Ignition Facility will provide a third line of sight for hotspot and cold fuel imaging and the first dedicated line of sight for 4.4-MeV γ-ray imaging of the remaining carbon ablator. To minimize the effort required to hold and align apertures inside the vacuum chamber, the apertures for the two lines of sight will be contained in the same array. In this work, we discuss the system requirements for neutron and γ-ray imaging and the resulting aperture array design.

5.
Rev Sci Instrum ; 89(10): 10I147, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399892

RESUMO

Neutron imaging provides a ready measurement of the shape of the "hot spot" core of an inertial confinement fusion implosion. The 14-MeV neutrons emitted by deuterium-tritium reactions are imaged at the National Ignition Facility using a pinhole array onto a scintillator, and the images are recorded on a camera. By changing the gate time of the camera, lower energy neutrons, downscattered by the cold fuel surrounding the hot spot, are recorded. The cold fuel density can be reconstructed using the two images. The kinematics of the scattering coupled with the scattering cross sections restrict the angular extent of the cold fuel sampled, with the backside of the implosion not being sampled at all. This work demonstrates the limited region of the cold fuel measured by the current line of sight (40%). At completion of the three planned lines of sight, 79% of the cold fuel will be sampled.

6.
Rev Sci Instrum ; 87(11): 11D830, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910305

RESUMO

The neutron imaging diagnostic at the National Ignition Facility has been operating since 2011 generating neutron images of deuterium-tritium (DT) implosions at peak compression. The current design features a scintillating fiber array, which allows for high imaging resolution to discern small-scale structure within the implosion. In recent years, it has become clear that additional neutron imaging systems need to be constructed in order to provide 3D reconstructions of the DT source and these additional views need to be on a shorter line of sight. As a result, there has been increased effort to identify new image collection techniques that improve upon imaging resolution for these next generation neutron imaging systems, such as monolithic deuterated scintillators. This work details measurements performed at the Weapons Neutron Research Facility at Los Alamos National Laboratory that compares the radiographic abilities of the fiber scintillator with a monolithic scintillator, which may be featured in a future short line of sight neutron imaging systems.

7.
Rev Sci Instrum ; 87(11): 11D821, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910447

RESUMO

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 µm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 µm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

8.
Rev Sci Instrum ; 87(11): 11D703, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910487

RESUMO

X-ray and neutrons are commonly used to image inertial confinement fusion implosions, providing key diagnostic information on the fuel assembly of burning deuterium-tritium (DT) fuel. The x-ray and neutron data provided are complementary as the production of neutrons and x-rays occurs from different physical processes, but typically these two images are collected from different views with no opportunity for co-registration of the two images. Neutrons are produced where the DT fusion fuel is burning; X-rays are produced in regions corresponding to high temperatures. Processes such as mix of ablator material into the hotspot can result in increased x-ray production and decreased neutron production but can only be confidently observed if the two images are collected along the same line of sight and co-registered. To allow direct comparison of x-ray and neutron data, a combined neutron x-ray imaging system has been tested at Omega and installed at the National Ignition Facility to collect an x-ray image along the currently installed neutron imaging line of sight. This system is described, and initial results are presented along with prospects for definitive coregistration of the images.

9.
Rev Sci Instrum ; 86(4): 043503, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933858

RESUMO

Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

10.
Rev Sci Instrum ; 85(11): 11E607, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430353

RESUMO

The Neutron Imaging System at NIF uses an array of plastic scintillator fibers in conjunction with a time-gated imaging system to form an image of the neutron emission from the imploded capsule. By gating on neutrons that have scattered from the 14.1 MeV DT energy to lower energy ranges, an image of the dense, cold fuel around the hotspot is also obtained. An unmoderated spallation neutron beamline at the Weapons Neutron Research facility at Los Alamos was used in conjunction with a time-gated imaging system to measure the yield of a scintillating fiber array over several energy bands ranging from 1 to 15 MeV. The results and comparison to simulation are presented.

11.
Rev Sci Instrum ; 85(11): 11E614, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430360

RESUMO

Neutron and x-ray images are collected at the National Ignition Facility (NIF) to measure the size and shape of inertial confinement fusion implosions. The x-ray images provide a measure of the size and shape of the hot region of the deuterium-tritium fuel while the neutron images provide a measure of the size and shape of the burning plasma. Although these two types of images are collected simultaneously, they are not collected along the same line of sight (LOS). One 14 MeV neutron image is collected on the NIF equator, and two x-ray images are collected along the polar axis and nearly perpendicular to the neutron imaging line of sight on the equator. Both measurements use pinhole apertures to form the images, but existing x-ray imaging provides time-resolved measurements while the neutron images are time-integrated. Detailed comparisons of the x-ray and neutron images can provide information on the fuel assembly, but these studies have been limited because the implosions are not azimuthally symmetric and the images are collected along different LOS. We have developed a conceptual design of a time-integrated x-ray imaging system that could be added to the existing neutron imaging LOS. This new system would allow these detailed studies, providing important information on the fuel assembly of future implosions. Here we present this conceptual design and the expected performance characteristics.

12.
Rev Sci Instrum ; 85(2): 023508, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593362

RESUMO

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (∼100 µm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-µm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics.

13.
Rev Sci Instrum ; 85(12): 123506, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25554292

RESUMO

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 µm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-µm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

14.
Phys Rev Lett ; 110(4): 044802, 2013 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-25166169

RESUMO

Neutrons are unique particles to probe samples in many fields of research ranging from biology to material sciences to engineering and security applications. Access to bright, pulsed sources is currently limited to large accelerator facilities and there has been a growing need for compact sources over the recent years. Short pulse laser driven neutron sources could be a compact and relatively cheap way to produce neutrons with energies in excess of 10 MeV. For more than a decade experiments have tried to obtain neutron numbers sufficient for applications. Our recent experiments demonstrated an ion acceleration mechanism based on the concept of relativistic transparency. Using this new mechanism, we produced an intense beam of high energy (up to 170 MeV) deuterons directed into a Be converter to produce a forward peaked neutron flux with a record yield, on the order of 10(10) n/sr. We present results comparing the two acceleration mechanisms and the first short pulse laser generated neutron radiograph.

15.
Rev Sci Instrum ; 83(10): 10D316, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126842

RESUMO

Inertial confinement fusion experiments at the National Ignition Facility are designed to understand the basic principles of creating self-sustaining fusion reactions by laser driven compression of deuterium-tritium (DT) filled cryogenic plastic capsules. The neutron imaging diagnostic provides information on the distribution of the central fusion reaction region and the surrounding DT fuel by observing neutron images in two different energy bands for primary (13-17 MeV) and down-scattered (6-12 MeV) neutrons. From this, the final shape and size of the compressed capsule can be estimated and the symmetry of the compression can be inferred. These experiments provide small sources with high yield neutron flux. An aperture design that includes an array of pinholes and penumbral apertures has provided the opportunity to image the same source with two different techniques. This allows for an evaluation of these different aperture designs and reconstruction algorithms.

16.
Rev Sci Instrum ; 83(10): 10D317, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126843

RESUMO

A neutron imaging diagnostic has recently been commissioned at the National Ignition Facility (NIF). This new system is an important diagnostic tool for inertial fusion studies at the NIF for measuring the size and shape of the burning DT plasma during the ignition stage of Inertial Confinement Fusion (ICF) implosions. The imaging technique utilizes a pinhole neutron aperture, placed between the neutron source and a neutron detector. The detection system measures the two dimensional distribution of neutrons passing through the pinhole. This diagnostic has been designed to collect two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically the first image measures the distribution of the 14 MeV neutrons and the second image of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core.

17.
Rev Sci Instrum ; 83(10): 10E522, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127029

RESUMO

Recent neutron imaging of experiments at the National Ignition Facility has provided useful information about the hotspot shape and cold-fuel distribution and has also given insight into avenues for improvement. Neutron image reconstruction depends on accurate pointing information because the point-spread function of the neutron aperture is not shift invariant. Current pointing techniques are limited in their accuracy and rely upon detailed information about the as-built structure of the array, which is difficult to determine. We present a technique for extracting high-precision pointing information from both neutron and x-ray images, and a new aperture design with features to facilitate this technique, and allow future co-registration of neutron and x-ray images.

18.
Rev Sci Instrum ; 81(10): 10D335, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033855

RESUMO

Numerical modeling of the neutron imaging system for the National Ignition Facility (NIF), forward from calculated target neutron emission to a camera image, will guide both the reduction of data and the future development of the system. Located 28 m from target chamber center, the system can produce two images at different neutron energies by gating on neutron arrival time. The brighter image, using neutrons near 14 MeV, reflects the size and symmetry of the implosion "hot spot." A second image in scattered neutrons, 10-12 MeV, reflects the size and symmetry of colder, denser fuel, but with only ∼1%-7% of the neutrons. A misalignment of the pinhole assembly up to ±175 µm is covered by a set of 37 subapertures with different pointings. The model includes the variability of the pinhole point spread function across the field of view. Omega experiments provided absolute calibration, scintillator spatial broadening, and the level of residual light in the down-scattered image from the primary neutrons. Application of the model to light decay measurements of EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A suggests that DPAC-30 and Liquid A would be preferred over the BCF99-55 scintillator chosen for the first NIF system, if they could be fabricated into detectors with sufficient resolution.

19.
Rev Sci Instrum ; 79(10): 10E537, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044518

RESUMO

The concepts and initial development efforts for a spatially resolved ion temperature diagnostic are described. The diagnostic is intended for Inertial Confinement Fusion experiments at the National Ignition Facility and is an integration of neutron aperture imaging and ion temperature techniques. The neutron imaging technique is extended by recording tomographic projections of the radiation-to-light converter on a streak camera. The streak record is used to calculate images at multiple times during the arrival of the thermally broadened 14.1 MeV neutron flux. The resulting set of images is used to determine the spatially resolved ion temperature.

20.
Ann Emerg Med ; 29(6): 731-4, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9174516

RESUMO

STUDY OBJECTIVE: To identify the physical properties of the materials most easily located in subcutaneous tissue through the use of conventional ultrasound. METHODS: High-resolution real-time sonography was performed by a credentialed sonographer on a chicken breast impregnated with five objects-a metal paper clip, a wooden toothpick, a plastic coffee stirrer, a shard of glass, and an 18-gauge needle. Transducer frequencies ranging from 3.5 to 7.5 MHz with linear, curvilinear, and sector-scanning formats were used. All images were interpreted by a staff attending radiologist with other study authors present. The chicken breast was then subjected to radiography for comparison. RESULTS: Wood yielded the strongest acoustic shadow; plastic had the next-best acoustic shadowing. The 7.5-MHz probe yielded its best resolution at shallow depths, whereas the 5-MHz probe was best at greater depths. CONCLUSION: We conclude that ultrasonography is an excellent technique for the localization and retrieval of nonradiopaque foreign objects in the superficial subcutaneous tissue. It should be given consideration for use in the removal of nonradiopaque superficial foreign objects when conventional radiographic techniques are not effective.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Glândulas Mamárias Animais/lesões , Lesões dos Tecidos Moles/diagnóstico por imagem , Ultrassonografia de Intervenção , Animais , Galinhas , Modelos Animais de Doenças , Feminino , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA