Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 11092, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32606446

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

2.
Sci Rep ; 9(1): 972, 2019 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-30700759

RESUMO

While the importance of the serotonergic system in obsessive compulsive disorder (OCD) is well established, its role in Tourette syndrome (TS) is uncertain. Particularly in TS patients with comorbid OCD (TS + OCD), decreased serotonin transporter (SERT) binding has been suggested. Here, we investigated for the first time SERT binding in TS patients with and without OCD (TS - OCD) compared to both healthy controls (HC) and OCD patients as well as the influence of escitalopram using the potent SERT imaging ligand [123I]2-((2-((dimethylamino)methyl)phenyl)thio)-5-iodophenylamine ([123I]ADAM) and single-photon emission tomography (SPECT). We included 33 adult subjects (10 HC, 10 TS - OCD, 8 TS + OCD and 5 OCD). In patients with OCD and TS + OCD [123I]ADAM SPECT was repeated after 12-16 weeks treatment with escitalopram. SERT binding was normal in patients with OCD and TS - OCD, but significantly increased (p < 0.05) in those with TS + OCD, particularly in caudate and midbrain compared to both HC and TS - OCD. Treatment with escitalopram resulted in a significant overall reduction in SERT binding (range, 19 to 79%, p values between 0.0409 and <0.0001) without any correlation with clinical improvement. Our results provide further evidence that alterations in the serotonergic system in TS are related to comorbid OCD and do not represent the primary cause of the disease.


Assuntos
Transtorno Obsessivo-Compulsivo/complicações , Transtorno Obsessivo-Compulsivo/metabolismo , Proteínas da Membrana Plasmática de Transporte de Serotonina/metabolismo , Síndrome de Tourette/complicações , Síndrome de Tourette/metabolismo , Adolescente , Adulto , Citalopram/uso terapêutico , Feminino , Humanos , Cinética , Masculino , Ligação Proteica , Síndrome de Tourette/tratamento farmacológico , Adulto Jovem
3.
Environ Sci Process Impacts ; 21(2): 224-241, 2019 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-30452047

RESUMO

Accurate and precise analyses of oil and gas (O&G) wastewaters and solids (e.g., sediments and sludge) are important for the regulatory monitoring of O&G development and tracing potential O&G contamination in the environment. In this study, 15 laboratories participated in an inter-laboratory comparison on the chemical characterization of three O&G wastewaters from the Appalachian Basin and four solids impacted by O&G development, with the goal of evaluating the quality of data and the accuracy of measurements for various analytes of concern. Using a variety of different methods, analytes in the wastewaters with high concentrations (i.e., >5 mg L-1) were easily detectable with relatively high accuracy, often within ±10% of the most probable value (MPV). In contrast, often less than 7 of the 15 labs were able to report detectable trace metal(loid) concentrations (i.e., Cr, Ni, Cu, Zn, As, and Pb) with accuracies of approximately ±40%. Despite most labs using inductively coupled plasma mass spectrometry (ICP-MS) with low instrument detection capabilities for trace metal analyses, large dilution factors during sample preparation and low trace metal concentrations in the wastewaters limited the number of quantifiable determinations and likely influenced analytical accuracy. In contrast, all the labs measuring Ra in the wastewaters were able to report detectable concentrations using a variety of methods including gamma spectroscopy and wet chemical approaches following Environmental Protection Agency (EPA) standard methods. However, the reported radium activities were often greater than ±30% different to the MPV possibly due to calibration inconsistencies among labs, radon leakage, or failing to correct for self-attenuation. Reported radium activities in solid materials had less variability (±20% from MPV) but accuracy could likely be improved by using certified radium standards and accounting for self-attenuation that results from matrix interferences or a density difference between the calibration standard and the unknown sample. This inter-laboratory comparison illustrates that numerous methods can be used to measure major cation, minor cation, and anion concentrations in O&G wastewaters with relatively high accuracy while trace metal(loid) and radioactivity analyses in liquids may often be over ±20% different from the MPV.


Assuntos
Compostos Inorgânicos/análise , Laboratórios/organização & administração , Petróleo/análise , Poluentes Radioativos/análise , Águas Residuárias/química , Região dos Apalaches
4.
Am J Infect Control ; 44(6): e91-4, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-26897700

RESUMO

There were 256 health care workers in 39 facilities who were interviewed about their perceptions of the quality of care of patients with and without multidrug-resistant organisms based on a standardized questionnaire. There are remarkable differences in the responses between facility types (acute care hospitals, long-term care hospitals, rehabilitation hospitals, and home care services). Hygiene management must be specifically tailored to the requirements of each facility.


Assuntos
Atitude do Pessoal de Saúde , Farmacorresistência Bacteriana Múltipla , Conhecimentos, Atitudes e Prática em Saúde , Pessoal de Saúde , Adolescente , Adulto , Idoso , Uso de Medicamentos/normas , Feminino , Alemanha , Humanos , Controle de Infecções/métodos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
5.
J Viral Hepat ; 23(5): 348-57, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26768955

RESUMO

Hepatitis C virus (HCV) infection may induce chronic fatigue and cognitive dysfunction. Virus replication was proven within the brain and HCV-positive cells were identified as microglia and astrocytes. We hypothesized that cerebral dysfunction in HCV-afflicted patients is associated with microglia activation. Microglia activation was assessed in vivo in 22 patients with chronic HCV infection compared to six healthy controls using [(11) C]-PK11195 Positron Emission Tomography (PET) combined with magnetic resonance tomography for anatomical localization. Patients were subdivided with regard to their PCR status, Fatigue Impact Scale score (FIS) and attention test sum score (ATS). A total of 12 patients (54.5%) were HCV PCR positive [of which 7 (58.3%) had an abnormal FIS and 7 (58.3%) an abnormal ATS], 10 patients (45.5%) were HCV PCR negative (5 (50%) each with an abnormal FIS or ATS). Patients without attention deficits showed a significantly higher accumulation of [(11) C]-PK11195 in the putamen (P = 0.05), caudate nucleus (P = 0.03) and thalamus (P = 0.04) compared to controls. Patients with and without fatigue did not differ significantly with regard to their specific tracer binding in positron emission tomography. Preserved cognitive function was associated with significantly increased microglia activation with predominance in the basal ganglia. This indicates a probably neuroprotective effect of microglia activation in HCV-infected patients.


Assuntos
Disfunção Cognitiva , Hepatite C Crônica/complicações , Hepatite C Crônica/patologia , Microglia/imunologia , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons
6.
GMS Krankenhhyg Interdiszip ; 6(1): Doc24, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22242105

RESUMO

Recently, the HACCP (Hazard Analysis and Critical Control Points) concept was proposed as possible way to implement process-based hygiene concepts in clinical practice, but the extent to which this food safety concept can be transferred into the health care setting is unclear. We therefore discuss possible ways for a translation of the principles of the HACCP for health care settings. While a direct implementation of food processing concepts into health care is not very likely to be feasible and will probably not readily yield the intended results, the underlying principles of process-orientation, in-process safety control and hazard analysis based counter measures are transferable to clinical settings. In model projects the proposed concepts should be implemented, monitored, and evaluated under real world conditions.

7.
Nuklearmedizin ; 49(4): 139-47, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20502846

RESUMO

AIM: Both IBZM SPECT and FDG PET may be used for differentiation between Parkinson's disease (PD) and atypical neurodegenerative parkinsonian syndromes (APS). However, there are only very limited data of both modalities in the same subjects. The present study compared both modalities with respect to inter-rater agreement in 30 patients with neurodegenerative parkinsonian syndromes (PS) confirmed by FP-CIT SPECT. METHODS: IBZM SPECT and FDG PET were categorized as PD or APS by visual inspection of standardized report pages and statistical parametric maps (SPMs). Categorization was performed independently by five readers. Inter-rater agreement was quantified using Cohen's kappa kappa. RESULTS: IBZM SPECT resulted in PD and APS in 11 and 19 cases, respectively (majoritarian categorization). Inter-rater agreement was kappa=0.64+/-0.10. FDG PET resulted in PD and APS in 12 and 18 cases, respectively (majoritarian categorization). Inter-rater agreement was kappa=0.68+/-0.07. Majoritarian diagnosis disagreed between IBZM SPECT and FDG PET in 13 cases (43%). Semi-quantitative analysis of IBZM SPECT using the striatum-to-reference distribution volume ratio was in good agreement with visual categorization (area under ROC curve 0.92). CONCLUSION: In neurodegenerative PS, inter-rater agreement of visual analysis is substantial in both IBZM SPECT and FDG PET. Furthermore, (I) visual analysis of IBZM SPECT is reliable if adequate standardized image display is used, (II) visual analysis of FDG SPMs allows unique categorization as either PD or APS in most subjects, and (III) IBZM SPECT and FDG PET are discordant in a significant fraction of cases.


Assuntos
Fluordesoxiglucose F18 , Transtornos Parkinsonianos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Benzamidas , Diagnóstico Diferencial , Antagonistas de Dopamina , Humanos , Variações Dependentes do Observador , Seleção de Pacientes , Pirrolidinas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA