Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int J Cardiovasc Imaging ; 39(1): 221-231, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36598691

RESUMO

In computed tomography, coronary artery calcium (CAC) scores are influenced by image reconstruction. The effect of a newly introduced deep learning-based reconstruction (DLR) on CAC scoring in relation to other algorithms is unknown. The aim of this study was to evaluate the effect of four generations of image reconstruction techniques (filtered back projection (FBP), hybrid iterative reconstruction (HIR), model-based iterative reconstruction (MBIR), and DLR) on CAC detectability, quantification, and risk classification. First, CAC detectability was assessed with a dedicated static phantom containing 100 small calcifications varying in size and density. Second, CAC quantification was assessed with a dynamic coronary phantom with velocities equivalent to heart rates of 60-75 bpm. Both phantoms were scanned and reconstructed with four techniques. Last, scans of fifty patients were included and the Agatston calcium score was calculated for all four reconstruction techniques. FBP was used as a reference. In the phantom studies, all reconstruction techniques resulted in less detected small calcifications, up to 22%. No clinically relevant quantification changes occurred with different reconstruction techniques (less than 10%). In the patient study, the cardiovascular risk classification resulted, for all reconstruction techniques, in excellent agreement with the reference (κ = 0.96-0.97). However, MBIR resulted in significantly higher Agatston scores (61 (5.5-435.0) vs. 81.5 (9.25-435.0); p < 0.001) and 6% reclassification rate. In conclusion, HIR and DLR reconstructed scans resulted in similar Agatston scores with excellent agreement and low-risk reclassification rate compared with routine reconstructed scans (FBP). However, caution should be taken with low Agatston scores, as based on phantom study, detectability of small calcifications varies with the used reconstruction algorithm, especially with MBIR and DLR.


Assuntos
Calcinose , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Imagens de Fantasmas , Algoritmos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Eur Radiol ; 32(5): 3447-3457, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34997284

RESUMO

OBJECTIVE: The aim of the current study was to systematically assess coronary artery calcium (CAC) detection and quantification for spectral photon-counting CT (SPCCT) in comparison to conventional CT and, in addition, to evaluate the possibility of radiation dose reduction. METHODS: Routine clinical CAC CT protocols were used for data acquisition and reconstruction of two CAC containing cylindrical inserts which were positioned within an anthropomorphic thorax phantom. In addition, data was acquired at 50% lower radiation dose by reducing tube current, and slice thickness was decreased. Calcifications were considered detectable when three adjacent voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). Quantification of CAC (as volume and mass score) was assessed by comparison with known physical quantities. RESULTS: In comparison with CT, SPCCT detected 33% and 7% more calcifications for the small and large phantoms, respectively. At reduced radiation dose and reduced slice thickness, small phantom CAC detection increased by 108% and 150% for CT and SPCCT, respectively. For the large phantom size, noise levels interfered with CAC detection. Although comparable between CT and SPCCT, routine protocols CAC quantification showed large deviations (up to 134%) from physical CAC volume. At reduced radiation dose and slice thickness, physical volume overestimations decreased to 96% and 72% for CT and SPCCT, respectively. In comparison with volume scores, mass score deviations from physical quantities were smaller. CONCLUSION: CAC detection on SPCCT is superior to CT, and was even preserved at a reduced radiation dose. Furthermore, SPCCT allows for improved physical volume estimation. KEY POINTS: • In comparison with conventional CT, increased coronary artery calcium detection (up to 156%) for spectral photon-counting CT was found, even at 50% radiation dose reduction. • Spectral photon-counting CT can more accurately measure physical volumes than conventional CT, especially at reduced slice thickness and for high-density coronary artery calcium. • For both conventional and spectral photon-counting CT, reduced slice thickness reconstructions result in more accurate physical mass approximation.


Assuntos
Calcinose , Doença da Artéria Coronariana , Calcinose/diagnóstico por imagem , Cálcio , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 32(1): 152-162, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34255159

RESUMO

OBJECTIVE: The aim of the current study was, first, to assess the coronary artery calcium (CAC) scoring potential of spectral photon-counting CT (SPCCT) in comparison with computed tomography (CT) for routine clinical protocols. Second, improved CAC detection and quantification at reduced slice thickness were assessed. METHODS: Raw data was acquired and reconstructed with several combinations of reduced slice thickness and increasing strengths of iterative reconstruction (IR) for both CT systems with routine clinical CAC protocols for CT. Two CAC-containing cylindrical inserts, consisting of CAC of different densities and sizes, were placed in an anthropomorphic phantom. A specific CAC was detectable when 3 or more connected voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). For all reconstructions, total CAC detectability was compared between both CT systems. Significant differences in CAC quantification (Agatston and volume scores) were assessed with Mann-Whitney U tests. Furthermore, volume scores were compared with the known CAC physical. RESULTS: CAC scores for routine clinical protocols were comparable between SPCCT and CT. SPCCT showed 34% and 4% higher detectability of CAC for the small and large phantom, respectively. At reduced slice thickness, CAC detection increased by 142% and 169% for CT and SPCCT, respectively. In comparison with CT, volume scores from SPCCT were more comparable with the physical volume of the CAC. CONCLUSION: CAC scores using routine clinical protocols are comparable between conventional CT and SPCCT. The increased spatial resolution of SPCCT allows for increased detectability and more accurate CAC volume estimation. KEY POINTS: • Coronary artery calcium scores using routine clinical protocols are comparable between conventional CT and spectral photon-counting CT. • In comparison with conventional CT, increased coronary artery calcium detectability was shown for spectral photon-counting CT due to increased spatial resolution. • Volumes scores were more accurately determined with spectral photon-counting CT.


Assuntos
Cálcio , Doença da Artéria Coronariana , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
4.
Scand J Med Sci Sports ; 28(3): 1036-1047, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28833626

RESUMO

Sudden cardiac death (SCD) is a devastating event in athletes. Screening efforts that were first directed at athletes younger than 35 years are now focusing on the rapidly growing group of older sportspersons. Athletes aged ≥35 years have a 10-fold increased risk of exercise-related cardiac arrest, mostly due to coronary artery disease (CAD). Although cardiac imaging is pivotal in identifying CAD, the role of imaging modalities in screening asymptomatic older sportspersons remains unclear. We performed a scoping review to identify the role of cardiac imaging to detect CAD in older sportspersons and to identify gaps in the existing literature. We searched MEDLINE, EMBASE and the Cochrane library for studies reporting data on cardiac imaging of CAD in sportspersons ≥35 years. The systematic search yielded 1737 articles, and 14 were included in this scoping review. Imaging modalities included two echocardiography, one unenhanced computed tomography (CT) for coronary artery calcium scoring (CACS), three CACS and contrast-enhanced CT angiography (CCTA), two CACS and cardiac magnetic resonance (CMR), one CCTA with CMR and echocardiography, two CCTA, two CMR, and one myocardial perfusion imaging article. The low number of relevant articles and the selection bias introduced by studying specific groups, like veteran marathon runners, indicate the need for future research. Cardiac CT (CACS and CCTA) probably has the highest potential for pre-participation screening, with high diagnostic value to detect CAD and low radiation dose. However, currently there is insufficient evidence for incorporating routine cardiac imaging in the pre-participation screening of asymptomatic sportspersons over 35 years.


Assuntos
Atletas , Doença da Artéria Coronariana/diagnóstico por imagem , Morte Súbita Cardíaca/prevenção & controle , Adulto , Idoso , Cálcio/análise , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão , Tomografia Computadorizada por Raios X
5.
Int J Cardiovasc Imaging ; 34(6): 947-957, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29285725

RESUMO

The objective of this study was to evaluate the influence of iterative reconstruction on coronary calcium scores (CCS) at different heart rates for four state-of-the-art CT systems. Within an anthropomorphic chest phantom, artificial coronary arteries were translated in a water-filled compartment. The arteries contained three different calcifications with low (38 mg), medium (80 mg) and high (157 mg) mass. Linear velocities were applied, corresponding to heart rates of 0, < 60, 60-75 and > 75 bpm. Data were acquired on four state-of-the-art CT systems (CT1-CT4) with routinely used CCS protocols. Filtered back projection (FBP) and three increasing levels of iterative reconstruction (L1-L3) were used for reconstruction. CCS were quantified as Agatston score and mass score. An iterative reconstruction susceptibility (IRS) index was used to assess susceptibility of Agatston score (IRSAS) and mass score (IRSMS) to iterative reconstruction. IRS values were compared between CT systems and between calcification masses. For each heart rate, differences in CCS of iterative reconstructed images were evaluated with CCS of FBP images as reference, and indicated as small (< 5%), medium (5-10%) or large (> 10%). Statistical analysis was performed with repeated measures ANOVA tests. While subtle differences were found for Agatston scores of low mass calcification, medium and high mass calcifications showed increased CCS up to 77% with increasing heart rates. IRSAS of CT1-T4 were 17, 41, 130 and 22% higher than IRSMS. Not only were IRS significantly different between all CT systems, but also between calcification masses. Up to a fourfold increase in IRS was found for the low mass calcification in comparison with the high mass calcification. With increasing iterative reconstruction strength, maximum decreases of 21 and 13% for Agatston and mass score were found. In total, 21 large differences between Agatston scores from FBP and iterative reconstruction were found, while only five large differences were found between FBP and iterative reconstruction mass scores. Iterative reconstruction results in reduced CCS. The effect of iterative reconstruction on CCS is more prominent with low-density calcifications, high heart rates and increasing iterative reconstruction strength.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Frequência Cardíaca , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Calcificação Vascular/diagnóstico por imagem , Simulação por Computador , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Humanos , Modelos Cardiovasculares , Imagens de Fantasmas , Calcificação Vascular/fisiopatologia
6.
Int J Cardiovasc Imaging ; 34(6): 959-966, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29285727

RESUMO

To evaluate the influence of heart rate on coronary calcium scores (CCS) using a dynamic phantom on four high-end computed tomography (CT) systems from different manufacturers. Artificial coronary arteries were moved in an anthropomorphic chest phantom at linear velocities, corresponding to < 60, 60-75 and > 75 beats per minute (bpm). Data was acquired with routinely used clinical protocols for CCS on four high-end CT systems (CT1-CT4). CCS, quantified as Agatston and mass scores were compared to reference scores at < 60 bpm. Influence of heart rate was assessed for each system with the cardiac motion susceptibility (CMS) Index. At increased heart rates (> 75 bpm), Agatston scores of the low mass calcification were similar to the reference score, while Agatston scores of the medium and high mass calcification increased significantly up to 50% for all CT systems. Threefold CMS increases at > 75 bpm in comparison with < 60 bpm were shown. For medium and high mass calcifications, significant differences in CMS between CT systems were found. Heart rate substantially influences CCS for high-end CT systems of four major manufacturers, but CT systems differ in motion susceptibility. Follow-up CCS CT scans should be acquired on the same CT system and protocol, and preferably with comparable heart rates.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Frequência Cardíaca , Imagens de Fantasmas , Calcificação Vascular/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Humanos , Valor Preditivo dos Testes , Calcificação Vascular/fisiopatologia
7.
Eur Radiol ; 27(12): 5244-5251, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28677062

RESUMO

OBJECTIVES: To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. METHODS: A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. RESULTS: Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm3 and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. CONCLUSIONS: Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. KEY POINTS: • Pulmonary nodule volumes were measured on virtual non-contrast and mono-energetic reconstructions • Mono-energetic reconstructions showed that higher attenuation results in larger volumes • This may explain the reported nodule volume underestimation on non-contrast enhanced CT • Mostly metastatic pulmonary nodules were evaluated, results might differ for benign nodules.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Iodo/farmacologia , Neoplasias Pulmonares/diagnóstico , Nódulos Pulmonares Múltiplos/diagnóstico , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Meios de Contraste/farmacologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
8.
PLoS One ; 12(2): e0172256, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28235014

RESUMO

We performed a prospective study in patients with chemotherapy induced febrile neutropenia to investigate the diagnostic value of low-dose computed tomography compared to standard chest radiography. The aim was to compare both modalities for detection of pulmonary infections and to explore performance of low-dose computed tomography for early detection of invasive fungal disease. The low-dose computed tomography remained blinded during the study. A consensus diagnosis of the fever episode made by an expert panel was used as reference standard. We included 67 consecutive patients on the first day of febrile neutropenia. According to the consensus diagnosis 11 patients (16.4%) had pulmonary infections. Sensitivity, specificity, positive predictive value and negative predictive value were 36%, 93%, 50% and 88% for radiography, and 73%, 91%, 62% and 94% for low-dose computed tomography, respectively. An uncorrected McNemar showed no statistical difference (p = 0.197). Mean radiation dose for low-dose computed tomography was 0.24 mSv. Four out of 5 included patients diagnosed with invasive fungal disease had radiographic abnormalities suspect for invasive fungal disease on the low-dose computed tomography scan made on day 1 of fever, compared to none of the chest radiographs. We conclude that chest radiography has little value in the initial assessment of febrile neutropenia on day 1 for detection of pulmonary abnormalities. Low-dose computed tomography improves detection of pulmonary infiltrates and seems capable of detecting invasive fungal disease at a very early stage with a low radiation dose.


Assuntos
Pneumopatias/complicações , Pneumopatias/diagnóstico por imagem , Neutropenia/complicações , Neutropenia/diagnóstico por imagem , Radiografia Torácica , Tomografia Computadorizada por Raios X , Adulto , Idoso , Infecções Bacterianas/complicações , Infecções Bacterianas/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Micoses/complicações , Micoses/diagnóstico por imagem , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Viroses/complicações , Viroses/diagnóstico por imagem , Adulto Jovem
9.
Int J Cardiovasc Imaging ; 33(6): 899-914, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28102510

RESUMO

To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s corresponding to heart rates between 60 and 75 bpm. The inserts were scanned five times with routinely used CCS protocols at reference dose and 40 and 80% dose reduction on four high-end CT systems. Filtered back projection (FBP) and increasing levels of IR were applied. Noise levels were determined. CCS, quantified as Agatston and mass scores, were compared to physical mass and scores at FBP reference dose. For the reference dose in combination with FBP, noise level variation between CT systems was less than 18%. Decreasing dose almost always resulted in increased CCS, while at increased levels of IR, CCS decreased again. The influence of IR on CCS was smaller than the influence of dose reduction. At reference dose, physical mass was underestimated 3-30%. All CT systems showed similar CCS at 40% dose reduction in combinations with specific reconstructions. For some CT systems CCS was not affected at 80% dose reduction, in combination with IR. This multivendor study showed that radiation dose reductions of 40% did not influence CCS in a dynamic phantom using state-of-the-art CT systems in combination with specific reconstruction settings. Dose reduction resulted in increased noise and consequently increased CCS, whereas increased IR resulted in decreased CCS.


Assuntos
Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Tomógrafos Computadorizados , Calcificação Vascular/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Desenho de Equipamento , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos
10.
Clin Radiol ; 71(8): 758-67, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26932775

RESUMO

Until recently, cardiovascular computed tomography angiography (CCTA) was associated with considerable radiation doses. The introduction of tube current modulation and automatic tube potential selection as well as high-pitch prospective ECG-triggering and iterative reconstruction offer the ability to decrease dose with approximately one order of magnitude, often to sub-millisievert dose levels. In parallel, advancements in computational technology have enabled the measurement of fractional flow reserve (FFR) from CCTA data (FFRCT). This technique shows potential to replace invasively measured FFR to select patients in need of coronary intervention. Furthermore, developments in scanner hardware have led to the introduction of dual-energy and photon-counting CT, which offer the possibility of material decomposition imaging. Dual-energy CT reduces beam hardening, which enables CCTA in patients with a high calcium burden and more robust myocardial CT perfusion imaging. Future-generation CT systems will be capable of counting individual X-ray photons. Photon-counting CT is promising and may result in a substantial further radiation dose reduction, vastly increased spatial resolution, and the introduction of a whole new class of contrast agents.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Exposição à Radiação/prevenção & controle , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Humanos , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos
11.
Clin Radiol ; 70(11): 1252-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26227475

RESUMO

AIM: To compare image quality of head and neck computed tomography angiography (CTA) reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MIR) algorithms. MATERIALS AND METHODS: The raw data of 34 studies were simultaneously reconstructed with FBP, HIR (iDose(4), Philips Healthcare, Best, the Netherlands), and with a prototype version of a MIR algorithm (IMR, Philips Healthcare). Objective (contrast-to-noise ratio [CNR], vascular contrast, automatic vessel analysis [AVA], stenosis grade) and subjective image quality (ranking at level of the circle of Willis, carotid bifurcation, and shoulder) of the five reconstructions were compared using repeated-measures analysis of variance (ANOVA) and post-hoc analysis. RESULTS: Vascular contrast was significantly higher in both the circle of Willis and carotid bifurcation with both levels of MIR compared to the other reconstruction methods (all p<0.0001). The CNR was highest for high MIR, followed by low MIR, high HIR, mid HIR and FBP (p<0.001 except low MIR versus high HIR; p>0.33). AVA showed most complete carotids in both MIR-levels, followed by high HIR (p>0.08), mid HIR (p<0.023) and FBP (p<0.010), vertebral arteries completeness was similar (p=0.40 and p=0.06). Stenosis grade showed no significant differences (p=0.16). High HIR showed the best subjective image quality at the circle of Willis and carotid bifurcation level, followed by mid HIR. At shoulder level, low MIR and high HIR were ranked best, followed by high MIR. CONCLUSION: Objectively, MIR significantly improved the overall image quality, reduced image noise, and improved automated vessel analysis, whereas FBP showed the lowest objective image quality. Subjectively, the highest level of HIR was considered superior at the level of the circle of Willis and the carotid bifurcation, and along with the lowest level of MIR for the origins of the neck arteries at shoulder level.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Círculo Arterial do Cérebro/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Análise de Variância , Angiografia/métodos , Angiografia/normas , Isquemia Encefálica/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Aneurisma Intracraniano/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Estudos Prospectivos , Melhoria de Qualidade , Trombose dos Seios Intracranianos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
12.
Br J Radiol ; 86(1029): 20130160, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23884758

RESUMO

OBJECTIVE: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. METHODS: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland-Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. RESULTS: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (p<0.05). The 95% CI of interscanner variability was within ±41.6%, ±18.2% and ±4.9% for 3, 5 and ≥8 mm nodules, respectively. The 95% CI of intrascanner variability was within ±28.6%, ±13.4% and ±2.6% for 3, 5 and ≥8 mm nodules, respectively. CONCLUSION: Different 64-MDCT scanners in low-dose settings yield good agreement in volumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. ADVANCES IN KNOWLEDGE: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Tomógrafos Computadorizados
13.
Clin Radiol ; 67(3): 277-85, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22119298

RESUMO

The educational objectives of this article are to provide an overview of the computed tomography (CT) findings in chronic thromboembolic pulmonary hypertension. This article reviews the key imaging findings at CT in patients with chronic thromboembolic pulmonary hypertension. After reading this article, the reader should have an improved awareness of the condition, its imaging features, and the CT imaging features associated with surgically accessible disease.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Coração/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/complicações , Embolia Pulmonar/complicações , Infarto Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA