Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 18(27): 17630-17641, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38924391

RESUMO

Osteoporosis disrupts the fine-tuned balance between bone formation and resorption, leading to reductions in bone quantity and quality and ultimately increasing fracture risk. Prevention and treatment of osteoporotic fractures is essential for reductions in mortality, morbidity, and the economic burden, particularly considering the aging global population. Extreme bone loss that mimics time-accelerated osteoporosis develops in the paralyzed limbs following complete spinal cord injury (SCI). In vitro nanoscale vibration (1 kHz, 30 or 90 nm amplitude) has been shown to drive differentiation of mesenchymal stem cells toward osteoblast-like phenotypes, enhancing osteogenesis and inhibiting osteoclastogenesis simultaneously. Here, we develop and characterize a wearable device designed to deliver and monitor continuous nanoamplitude vibration to the hindlimb long bones of rats with complete SCI. We investigate whether a clinically feasible dose of nanovibration (two 2 h/day, 5 days/week for 6 weeks) is effective at reversing the established SCI-induced osteoporosis. Laser interferometry and finite element analysis confirmed transmission of nanovibration into the bone, and microcomputed tomography and serum bone formation and resorption markers assessed effectiveness. The intervention did not reverse SCI-induced osteoporosis. However, serum analysis indicated an elevated concentration of the bone formation marker procollagen type 1 N-terminal propeptide (P1NP) in rats receiving 40 nm amplitude nanovibration, suggesting increased synthesis of type 1 collagen, the major organic component of bone. Therefore, enhanced doses of nanovibrational stimulus may yet prove beneficial in attenuating/reversing osteoporosis, particularly in less severe forms of osteoporosis.


Assuntos
Osteoporose , Traumatismos da Medula Espinal , Vibração , Animais , Ratos , Osteoporose/patologia , Osteoporose/prevenção & controle , Ratos Sprague-Dawley , Microtomografia por Raio-X , Osteogênese/efeitos dos fármacos , Feminino , Dispositivos Eletrônicos Vestíveis , Nanotecnologia
2.
J R Soc Interface ; 21(215): 20230779, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38903010

RESUMO

Many animals employ a second frequency filter beyond the initial filtering of the eardrum (or tympanal membrane). In the field cricket ear, both the filtering mechanism and the transmission path from the posterior tympanal membrane (PTM) have remained unclear. A mismatch between PTM vibrations and sensilla tuning has prompted speculations of a second filter. PTM coupling to the tracheal branches is suggested to support a transmission pathway. Here, we present three independent lines of evidence converging on the same conclusion: the existence of a series of linked membranes with distinct resonant frequencies serving both filtering and transmission functions. Micro-computed tomography (µ-CT) highlighted the 'dividing membrane (DivM)', separating the tracheal branches and connected to the PTM via the dorsal membrane of the posterior tracheal branch (DM-PTB). Thickness analysis showed the DivM to share significant thinness similarity with the PTM. Laser Doppler vibrometry indicated the first of two PTM vibrational peaks, at 6 and 14 kHz, originates not from the PTM but from the coupled DM-PTB. This result was corroborated by µ-CT-based finite element analysis. These findings clarify further the biophysical source of neuroethological pathways in what is an important model of behavioural neuroscience. Tuned microscale coupled membranes may also hold biomimetic relevance.


Assuntos
Análise de Elementos Finitos , Gryllidae , Microtomografia por Raio-X , Animais , Gryllidae/fisiologia , Membrana Timpânica/fisiologia , Membrana Timpânica/diagnóstico por imagem , Vibração
3.
Adv Mater ; 36(23): e2310789, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38253339

RESUMO

Conventional osteogenic platforms utilize active growth factors to repair bone defects that are extensive in size, but they can adversely affect patient health. Here, an unconventional osteogenic platform is reported that functions by promoting capture of inactive osteogenic growth factor molecules to the site of cell growth for subsequent integrin-mediated activation, using a recombinant fragment of latent transforming growth factor beta-binding protein-1 (rLTBP1). It is shown that rLTBP1 binds to the growth-factor- and integrin-binding domains of fibronectin on poly(ethyl acrylate) surfaces, which immobilizes rLTBP1 and promotes the binding of latency associated peptide (LAP), within which inactive transforming growth factor beta 1 (TGF-ß1) is bound. rLTBP1 facilitates the interaction of LAP with integrin ß1 and the subsequent mechanically driven release of TGF-ß1 to stimulate canonical TGF-ß1 signaling, activating osteogenic marker expression in vitro and complete regeneration of a critical-sized bone defect in vivo.


Assuntos
Osteogênese , Fator de Crescimento Transformador beta1 , Animais , Humanos , Fator de Crescimento Transformador beta1/metabolismo , Fibronectinas/metabolismo , Fibronectinas/química , Proteínas de Ligação a TGF-beta Latente/metabolismo , Proteínas de Ligação a TGF-beta Latente/química , Regeneração Óssea , Propriedades de Superfície , Integrinas/metabolismo , Ligação Proteica , Integrina beta1/metabolismo , Transdução de Sinais
4.
R Soc Open Sci ; 10(8): 230929, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37593713

RESUMO

Many solid tumours (e.g. sarcoma, carcinoma and lymphoma) form a disorganized neo-vasculature that initiates uncontrolled vessel formation to support tumour growth. The complexity of these environments poses a significant challenge for tumour medicine research. While animal models are commonly used to address some of these challenges, they are time-consuming and raise ethical concerns. In vitro microphysiological systems have been explored as an alternative, but their production typically requires multi-step lithographic processes that limit their production. In this work, a novel approach to rapidly develop multi-material tissue-mimicking, cell-compatible platforms able to represent the complexity of a solid tumour's neo-vasculature is investigated via stereolithography three-dimensional printing. To do so, a series of acrylate resins that yield covalently photo-cross-linked hydrogels with healthy and diseased mechano-acoustic tissue-mimicking properties are designed and characterized. The potential viability of these materials to displace animal testing in preclinical research is assessed by studying the morphology, actin expression, focal adhesions and nitric oxide release of human umbilical vein endothelial cells. These materials are exploited to produce a simplified multi-material three-dimensional printed model of the neo-vasculature of a solid tumour, demonstrating the potential of our approach to replicate the complexity of solid tumours in vitro without the need for animal testing.

5.
J Musculoskelet Neuronal Interact ; 22(2): 212-234, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35642701

RESUMO

OBJECTIVE: Characterise the spatiotemporal trabecular and cortical bone responses to complete spinal cord injury (SCI) in young rats. METHODS: 8-week-old male Wistar rats received T9-transection SCI and were euthanised 2-, 6-, 10- or 16-weeks post-surgery. Outcome measures were assessed using micro-computed tomography, mechanical testing, serum markers and Fourier-transform infrared spectroscopy. RESULTS: The trabecular and cortical bone responses to SCI are site-specific. Metaphyseal trabecular BV/TV was 59% lower, characterised by fewer and thinner trabeculae at 2-weeks post-SCI, while epiphyseal BV/TV was 23% lower with maintained connectivity. At later-time points, metaphyseal BV/TV remained unchanged, while epiphyseal BV/TV increased. The total area of metaphyseal and mid-diaphyseal cortical bone were lower from 2-weeks and between 6- and 10-weeks post-SCI, respectively. This suggested that SCI-induced bone changes observed in the rat model were not solely attributable to bone loss, but also to suppressed bone growth. No tissue mineral density differences were observed at any time-point, suggesting that decreased whole-bone mechanical properties were primarily the result of changes to the spatial distribution of bone. CONCLUSION: Young SCI rat trabecular bone changes resemble those observed clinically in adult and paediatric SCI, while cortical bone changes resemble paediatric SCI only.


Assuntos
Densidade Óssea , Traumatismos da Medula Espinal , Animais , Osso e Ossos , Humanos , Masculino , Ratos , Ratos Wistar , Traumatismos da Medula Espinal/diagnóstico por imagem , Microtomografia por Raio-X
6.
Bone Rep ; 16: 101592, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35637974

RESUMO

Objective: Characterise the spatiotemporal responses of trabecular and cortical bone to complete spinal cord injury (SCI) in the skeletally mature rat in the acute (4-week) period following injury. Methods: The spinal cord of 5-month old male rats was transected at the T9 level. Outcome measures were assessed using micro-computed tomography, three-point bending and serum markers at 1-, 2-, and 4-weeks post-transection. Comparison was made with time-0 and sham animals. Results: Lower levels of circulating serum bone formation markers and higher bone resorption markers suggested uncoupled bone turnover as early at 1-week post-transection. Micro-computed tomography showed metaphyseal and epiphyseal trabecular bone loss was observed only at 4-weeks post-transection. The bone loss was site-specific with a more severe reduction in trabecular BV/TV observed in the metaphyseal (50%) relative to epiphyseal (19%) region. Metaphyseal trabecular bone exhibited a 54% reduction in connectivity density while the epiphyseal trabecular bone was unaffected. Cortical bone deficits were not seen over the time periods examined. Conclusions: The study demonstrates that the skeletally mature spinal cord transected rat model replicates the biphasic pattern of osteoporotic changes observed in the human SCI population, providing a relevant model for testing the efficacy of interventions against SCI-induced osteoporosis.

7.
Bone Rep ; 12: 100233, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31886322

RESUMO

Micro-Computed Tomography bone analysis is the gold standard method for assessing trabecular and cortical bone microarchitecture in small animal bones. This technique reports morphometric parameters as averages over selected volumes of interest (VOIs). This study proposes the introduction of an additional global 2D morphometric step into the analysis process, that provides a survey of the underlying morphometric variation present throughout both trabecular and cortical bone. The visualisation of these morphometric distributions provides a systematic approach to VOI selection that provides rationale and adds confidence to subsequent 3D morphometric analysis. To test the applicability and value of this methodological addition it was applied to the distal femur of a rat model of spinal cord injury (SCI)-induced osteoporosis. The 2D morphometric variation of both trabecular and cortical bone was quantified as a function of bone length. SCI-induced osteoporosis was localised in i) trabecular bone, where metaphyseal bone was more severely affected than epiphyseal bone, and there was a significant reduction in Distal Femoral Trabecular Extent, a new parameter defined here that quantifies how far trabecular bone penetrates in to the marrow cavity, ii) cortical bone, where diaphyseal bone underwent significant lowering of both cortical area and thickness, while distal-metaphyseal bone did not. Theses site-specific changes were validated, further elucidated and compared with follow-up conventional 3D analysis. The techniques applied here are equally applicable to other long bones (tibia, humerus, radius, ulna), other types of imaging modality and other types of experimental design including the effects of rehabilitation, aging, loading, gene knockout and pharmacological intervention.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA