Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Geohealth ; 5(8): e2021GH000443, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34471788

RESUMO

The purpose of this consensus document was to develop feasible, evidence-based occupational heat safety recommendations to protect the US workers that experience heat stress. Heat safety recommendations were created to protect worker health and to avoid productivity losses associated with occupational heat stress. Recommendations were tailored to be utilized by safety managers, industrial hygienists, and the employers who bear responsibility for implementing heat safety plans. An interdisciplinary roundtable comprised of 51 experts was assembled to create a narrative review summarizing current data and gaps in knowledge within eight heat safety topics: (a) heat hygiene, (b) hydration, (c) heat acclimatization, (d) environmental monitoring, (e) physiological monitoring, (f) body cooling, (g) textiles and personal protective gear, and (h) emergency action plan implementation. The consensus-based recommendations for each topic were created using the Delphi method and evaluated based on scientific evidence, feasibility, and clarity. The current document presents 40 occupational heat safety recommendations across all eight topics. Establishing these recommendations will help organizations and employers create effective heat safety plans for their workplaces, address factors that limit the implementation of heat safety best-practices and protect worker health and productivity.

2.
J Occup Environ Hyg ; 18(4-5): 203-211, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33819135

RESUMO

Firefighters' protective clothing (FPC) can limit human thermoregulation due to limited water vapor permeability and insulation. This study investigated the effect of cooling on the physiological responses and probability of hyperthermia in subjects wearing FPC during exercise in a hot environment. Twelve males participated in this study. A maximal graded treadmill exercise test was performed to measure maximal oxygen uptake (V̇O2max) and to assess subjects' capacity to perform the assigned exercise. Exercise included treadmill walking at 40% V̇O2max in warm (30 °C) and humid (70% RH) conditions for 40 min while wearing FPC. Subjects participated in two randomly counterbalanced assigned experimental protocols: control (no cooling) and intervention (cooling). The experimental intervention consisted of a cooling garment infused with cooled water (18 °C) through silastic tubing sewn into the fabric and worn underneath FPC. Each subject served as their own control and, therefore, completed both the control and intervention of the protocol. A logistic regression model was used to analyze the interaction effect of cooling on the probability of progression to hyperthermia (Tc ≥ 38 °C). Subjects' physiological responses increased during exercise in a warm and humid environment. Active cooling decreased (p < 0.05) the thermal stress thereby reducing the probability of hyperthermia while exercising in hot and humid conditions. The results indicate that when cooling was used each subject, on average, was 91% less likely to reach the lower threshold limit of hyperthermia. Exercise in hot environments while wearing FPC results in significant physiological strain, which may lead to hyperthermia. Utilization of a cooling garment reduced physiological strain and the probability of hyperthermia.


Assuntos
Bombeiros , Temperatura Corporal , Regulação da Temperatura Corporal , Frequência Cardíaca , Temperatura Alta , Humanos , Hipertermia , Masculino , Probabilidade , Roupa de Proteção
3.
ASHRAE J ; 127(1): 693-704, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37207044

RESUMO

This paper provides recommendations on thermal and moisture parameters (air, temperature, and humidity content) in different types of buildings under normal and emergency operation conditions in extreme climate conditions, e.g., cold/arctic (U.S. Department of Energy [DOE] climate zones 6-8) and hot and humid (DOE climate zones 0-2a). Three scenarios are considered under normal operating conditions: when the building/space is occupied, temporarily unoccupied (2-5 days), and unoccupied long term (e.g., hibernated). These thermal parameters are necessary to achieve one or several of the following purposes.

4.
J Occup Environ Hyg ; 17(5): 243-252, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32150701

RESUMO

Firefighting is physically and mentally strenuous, requiring rapid, appropriate decision-making in hot environments. Intact cognitive function is imperative to firefighters' effectiveness and safety. The study purpose was to investigate the effect of hyperthermia and the effect of body cooling on sustained attention and response inhibition while wearing firefighters' personal protective ensembles after exercise in a hot environment. Twelve healthy males were recruited to participate in two randomly assigned exercise sessions (walking on a treadmill for 40 min at 40% [Formula: see text] O2max while wearing firefighter's protective ensemble) in a hot environment: control (no cooling) and intervention (cooling). For intervention sessions, a cooling garment was worn underneath firefighter's protective ensemble and infused with 18 °C water supplied by an external water circulator. Participants performed a computerized Go/No-Go (a measure of cognitive function) test three times at baseline and post-exercise for each experimental session. Participants completed baseline testing while wearing cotton athletic clothing. The exercise continued until the core temperature reached ∼39 °C (for all subjects regardless of cooling or non-cooling experimental sessions). Following hyperthermia, participants' physiological responses were significantly increased after exercise. Subjects' reaction time was significantly reduced (improved) after experiencing thermal strain and reaching hyperthermia. The cooling method had a significant impact on suppressing the physiological load, i.e., body cooling delayed the time to reach a Tc of 39 °C (p ≤ 0.05), but not cognitive inhibition and attention (reaction time and accuracy). Unexpectedly, hyperthermia resulted in shorter reaction time following exercise (16.64 ± 5.62; p < 0.03), likely influenced by increased attention/vigilance. Hyperthermia may trigger an acute increase in alertness, causing decreased reaction time.


Assuntos
Regulação da Temperatura Corporal , Temperatura Corporal/fisiologia , Cognição/fisiologia , Temperatura Baixa , Frequência Cardíaca/fisiologia , Temperatura Alta/efeitos adversos , Roupa de Proteção/normas , Adulto , Estudos Transversais , Bombeiros , Humanos , Masculino , Adulto Jovem
5.
Int J Biometeorol ; 63(3): 405-427, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30710251

RESUMO

Exertional heat illness (EHI) risk is a serious concern among athletes, laborers, and warfighters. US Governing organizations have established various activity modification guidelines (AMGs) and other risk mitigation plans to help ensure the health and safety of their workers. The extent of metabolic heat production and heat gain that ensue from their work are the core reasons for EHI in the aforementioned population. Therefore, the major focus of AMGs in all settings is to modulate the work intensity and duration with additional modification in adjustable extrinsic risk factors (e.g., clothing, equipment) and intrinsic risk factors (e.g., heat acclimatization, fitness, hydration status). Future studies should continue to integrate more physiological (e.g., valid body fluid balance, internal body temperature) and biometeorological factors (e.g., cumulative heat stress) to the existing heat risk assessment models to reduce the assumptions and limitations in them. Future interagency collaboration to advance heat mitigation plans among physically active population is desired to maximize the existing resources and data to facilitate advancement in AMGs for environmental heat.


Assuntos
Exercício Físico , Transtornos de Estresse por Calor/prevenção & controle , Temperatura Alta , Aclimatação , Atletas , Guias como Assunto , Humanos , Militares , Saúde Ocupacional , Estados Unidos
6.
Ergonomics ; 54(12): 1197-206, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22103727

RESUMO

Firefighters are required to use a self-contained breathing apparatus (SCBA) for respiratory protection when engaged in a variety of firefighting duties. While the SCBA provides crucial respiratory support and protection, it is also cumbersome and heavy, thus adding to the physical work performed by the firefighter. The purpose of the present study was to evaluate and compare the low profile SCBA prototype to a standard SCBA, as assessed by the objective and subjective measures of mobility and comfort, time of donning/doffing, as well as by acquiring user feedback on SCBA design features during field activities. The results of the present study indicated that the prototype SCBA was rated as a significant improvement over the standard SCBA in the areas of range of motion (ROM), mobility, comfort, induction of fatigue, interaction with protective clothing, and operability when worn over a standard firefighter ensemble, while performing a series of International Association of Fire Fighters Fire Ground Survival Program training exercises. STATEMENT OF RELEVANCE: A prototype SCBA was evaluated and compared with a standard SCBA, focusing on the objective and subjective measures of mobility and comfort during field activities. Feedback from end users was collected during the evaluation. The findings of the present study can be used for improving the system design and overall performance of new prototype SCBAs.


Assuntos
Incêndios , Movimento , Dispositivos de Proteção Respiratória , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Resistência Física , Amplitude de Movimento Articular , Trabalho de Resgate
7.
Ergonomics ; 54(7): 626-35, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21770750

RESUMO

While a personal protective equipment (PPE) ensemble effectively provides workers with protection from occupational hazards, working in a vapour-resistant ensemble increases the risk of heat illness/injuries and physiological burdens. The purpose of this study was to investigate the effect of body cooling via a liquid-cooled garment (LCG) underneath a PPE ensemble on perceived thermal strain, physiological responses and ergonomics during an intermittent treadmill exercise in warm environmental conditions. The results of the present study indicated that the concomitant wearing of LCG underneath the PPE ensemble significantly reduced subjective perception of heat and alleviated overall increase in body temperature and heart rate while no impact of wearing LCG on ergonomic features was found. The extension of the present findings to practical applications in occupational settings requires further research on a LCG system design and performance evaluations while the LCG is incorporated within the PPE ensemble. STATEMENT OF RELEVANCE: Implementation of a LCG underneath PPE for body cooling was investigated, focusing on its impact on individuals' perceived thermal strain, physiological responses and ergonomics. The findings of the present study indicated that body cooling via a wearable LCG underneath PPE significantly alleviated both perceived thermal and physiological strain in uncompensable heat stress condition.


Assuntos
Transtornos de Estresse por Calor/prevenção & controle , Saúde Ocupacional , Esforço Físico , Roupa de Proteção , Adulto , Temperatura Corporal , Frequência Cardíaca , Temperatura Alta , Humanos , Masculino , Percepção , Estresse Fisiológico
8.
J Occup Environ Hyg ; 8(7): 409-16, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21660834

RESUMO

This study investigated the effects of body cooling using liquid cooling garments (LCG) on performance time (PT) and recovery in individuals wearing a fully equipped prototype firefighter ensemble (PFE) incorporating a self-contained breathing apparatus (SCBA). Six healthy male participants (three firefighters and three non-firefighters) completed six experimental sessions in an environmental chamber (35°C, 50% relative humidity), consisting of three stages of 15 min exercise at 75% VO2max, and 10 min rest following each exercise stage. During each session, one of the following six conditions was administered in a randomized order: control (no cooling, CON); air ventilation of exhaust SCBA gases rerouted into the PFE (AV); top cooling garment (TCG); TCG combined with AV (TCG+AV); a shortened whole body cooling garment (SCG), and SCG combined with AV (SCG+AV). Results showed that total PT completed was longer under SCG and SCG+AV compared with CON, AV, TCG, and TCG+AV (p<0.01). Magnitude of core temperature (Tc) elevation was significantly decreased when SCG was utilized (p<0.01), and heart rate recovery rate (10 min) was enhanced under SCG, SCG+AV, TCG, and TCG+AV compared with CON (p<0.05). Estimated Esw rate (kg·h(-1)) was the greatest in CON, 1.62 (0.37), and the least in SCG+AV 0.98 (0.44): (descending order: CON>AV>TCG=TCG+AV>SCG>SCG+AV) without a statistical difference between the conditions (p<0.05). Results of the present study suggest that the application of LCG underneath the PFE significantly improves the recovery during a short period of rest and prolongs performance time in subsequent bouts of exercise. LCG also appears to be an effective method for body cooling that promotes heat dissipation during uncompensable heat stress.


Assuntos
Temperatura Corporal , Saúde Ocupacional , Esforço Físico , Roupa de Proteção , Regulação da Temperatura Corporal , Exercício Físico , Teste de Esforço , Frequência Cardíaca , Temperatura Alta , Humanos , Masculino , Estresse Fisiológico , Fatores de Tempo , Trabalho
9.
J Occup Environ Hyg ; 8(1): 49-57, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21154108

RESUMO

This study investigated the physiological responses to wearing a standard firefighter ensemble (SE) and a prototype ensemble (PE) modified from the SE that contained additional features, such as magnetic ring enclosures at the glove-sleeve interface, integrated boot-pant interface, integrated hood-SCBA facepiece interface, and a novel hose arrangement that rerouted self-contained breathing apparatus (SCBA) exhaust gases back into the upper portion of the jacket. Although the features of the PE increased the level of encapsulation of the wearer that could lead to increased physiological stress compared with the SE, it was hypothesized that the rerouted exhaust gases provided by the PE hose assembly would (1) provide convective cooling to the upper torso, (2) reduce the thermal stress experienced by the wearer, and (3) reduce the overall physiological stress imposed by the PE such that it would be either less or not significantly different from the SE. Ten subjects (seven male, three female) performed treadmill exercise in an environmental chamber (22°C, 50% RH) at 50% [image omitted]O(2max) while wearing either the SE with an SCBA or the PE with an SCBA either with or without the hose attached (designated PEWH and PENH, respectively). Heart rate (HR), rectal and intestinal temperatures (T(re), T(in)), sweat loss, and endurance time were measured. All subjects completed at least 20 min of treadmill exercise during the testing. At the end of exercise, there was no difference in T(re) (p = 0.45) or T(in) (p = 0.42), HR, or total sweat loss between the SE and either PEWH or PENH (p = 0.59). However, T(sk) was greater in PEWH and PENH compared with SE (p < 0.05). Total endurance time in SE was greater than in either PEWH or PENH (p < 0.05). Thus, it was concluded that the rerouting of exhaust gases to the jacket did not provide significant convective cooling or reduce thermal stress compared with the SE under the mild conditions selected, and the data did not support the hypotheses of the present study.


Assuntos
Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Estresse Fisiológico , Adulto , Regulação da Temperatura Corporal , Feminino , Incêndios , Frequência Cardíaca , Humanos , Masculino , Resistência Física , Equipamentos de Proteção , Temperatura Cutânea
10.
Respir Care ; 55(5): 569-77, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20420727

RESUMO

OBJECTIVE: To assess the physiological impact of the N95 filtering facepiece respirator (FFR) on healthcare workers. METHODS: Ten healthcare workers each conducted multiple 1-hour treadmill walking sessions, at 1.7 miles/h, and at 2.5 miles/h, while wearing FFR with exhalation valve, FFR without exhalation valve, and without FFR (control session). We monitored heart rate, respiratory rate, tidal volume, minute volume, blood oxygen saturation, and transcutaneously measured P(CO2). We also measured user comfort and exertion, FFR moisture retention, and the carbon dioxide and oxygen concentrations in the FFR's dead space. RESULTS: There were no significant differences between FFR and control in the physiological variables, exertion scores, or comfort scores. There was no significant difference in moisture retention between FFR with and without exhalation valve. Two subjects had peak P(CO2) > or = 50 mm Hg. The FFR with exhalation valve offered no benefit in physiological burden over the FFR without valve. The FFR dead-space oxygen and carbon dioxide levels did not meet the Occupational Safety and Health Administration's ambient workplace standards. CONCLUSIONS: In healthy healthcare workers, FFR did not impose any important physiological burden during 1 hour of use, at realistic clinical work rates, but the FFR dead-space carbon dioxide and oxygen levels were significantly above and below, respectively, the ambient workplace standards, and elevated P(CO2) is a possibility. Exhalation valve did not significantly ameliorate the FFR's P(CO2) impact.


Assuntos
Pessoal de Saúde , Frequência Cardíaca/fisiologia , Máscaras/normas , Exposição Ocupacional/prevenção & controle , Dispositivos de Proteção Respiratória/normas , Trabalho Respiratório/fisiologia , Adulto , Desenho de Equipamento , Segurança de Equipamentos , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Valores de Referência , Volume de Ventilação Pulmonar/fisiologia , Local de Trabalho/normas , Adulto Jovem
11.
Am J Infect Control ; 38(5): 381-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20189685

RESUMO

BACKGROUND: Elastomeric air-purifying respirators offer the benefit of reusability, but their physiological impact on health care workers is unknown. METHODS: Ten health care workers exercised at 2 health care-associated work rates wearing an elastomeric air-purifying respirator. Mixed inhalation/exhalation respirator dead space gases (oxygen, carbon dioxide) were sampled, and physiological parameters were monitored (heart rate, breathing rate, tidal volume, minute volume, oxygen saturation, transcutaneous carbon dioxide). Numerical rating scales were used to evaluate comfort and exertion. RESULTS: Compared with controls (no respirator), significant decreases in the breathing rate at both work rates (P < .05) and increases in tidal volume at the lower work rate (P < .01) were noted with respirator use. Approximately half the subjects had transcutaneous carbon dioxide levels above the upper limit of normal after 1 hour of use. Although well tolerated, comfort was negatively impacted by elastomeric air-purifying respirators wear. CONCLUSION: Reusable elastomeric air-purifying respirators impose little additional physiological burden over the course of 1 hour at usual health care work rates. However, the potential for carbon dioxide retention in a significant proportion of users exists and requires further investigation.


Assuntos
Pessoal de Saúde , Dispositivos de Proteção Respiratória , Poluição do Ar em Ambientes Fechados , Testes Respiratórios , Reutilização de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Teste de Materiais , Monitorização Fisiológica , Volume de Ventilação Pulmonar
12.
Respirology ; 15(3): 516-21, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20337987

RESUMO

BACKGROUND AND OBJECTIVE: Filtering facepiece respirators ('N95 Masks') may be in short supply during large-scale infectious outbreaks. Suggestions have been made to extend their useful life by using a surgical mask as an outer barrier, but the physiological impact of this added barrier upon the wearer has not been studied. METHODS: A surgical mask was worn over an N95 filtering facepiece respirator by 10 healthcare workers for 1 h at each of two work rates. Heart rate, respiratory rate, tidal volume, minute volume, oxygen saturation, transcutaneous carbon dioxide levels and respirator dead space gases were monitored and compared with controls (N95 filtering facepiece respirator without a surgical mask). Subjective perceptions of exertion and comfort were assessed by numerical rating scales. RESULTS: There were no significant differences in physiological variables between those who used surgical masks and controls. Surgical masks decreased dead space oxygen concentrations of the filtering facepiece respirators at the lesser work rate (P = 0.03) and for filtering facepiece respirators with an exhalation valve at the higher work rate (P = 0.003). Respirator dead space oxygen and carbon dioxide levels were not harmonious with Occupational Safety and Health Administration workplace ambient atmosphere standards. Exertion and comfort scores were not significantly impacted by the surgical mask. CONCLUSIONS: Use of a surgical mask as an outer barrier over N95 filtering facepiece respirators does not significantly impact the physiological burden or perceptions of comfort and exertion by the wearer over that experienced without use of a surgical mask.


Assuntos
Pessoal de Saúde , Frequência Cardíaca/fisiologia , Máscaras , Mecânica Respiratória/fisiologia , Dispositivos de Proteção Respiratória , Adulto , Dióxido de Carbono/metabolismo , Estudos de Casos e Controles , Saúde Ambiental , Feminino , Humanos , Masculino , Saúde Ocupacional , Oxigênio/metabolismo , Esforço Físico/fisiologia , Volume de Ventilação Pulmonar/fisiologia
13.
Appl Ergon ; 41(4): 636-41, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20153458

RESUMO

Many studies have shown that fire fighter turnout gear and equipment may restrict mobility. The restriction of movement is usually due to a decrease in range of motion (ROM). It is important to know how much the decrease in ROM affects performance. The aim of this study was to determine the effects of fire fighter protective ensembles on mobility and performance by measuring static and dynamic range of motion (ROM) and job-related tasks. Eight healthy adults (5 males, 3 females), aged 20-40 years, participated in this study. The study consisted of measuring a battery of motions and fire fighter specific tasks while wearing a standard fire fighter ensemble (SE) or regular light clothing (baseline or BL). Several BL ROM tests were significantly (p < 0.05) different from the SE test, including a decrease in shoulder flexion, cervical rotation and flexion, trunk lateral flexion, and stand and reach. There was a significant decrease in time from SE to baseline performing the one-arm search task and object lift. These overall findings support the need for a comprehensive ergonomic evaluation of protective clothing systems to ascertain human factors issues. The development of a Standard Ergonomics Test Practice for further use in laboratories that conduct personal protective systems evaluations using human test subjects is recommended.


Assuntos
Incêndios , Roupa de Proteção , Amplitude de Movimento Articular , Análise e Desempenho de Tarefas , Adulto , Antropometria , Feminino , Humanos , Masculino , Saúde Ocupacional , Adulto Jovem
14.
J Occup Environ Hyg ; 7(2): 109-14, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20017053

RESUMO

We evaluated the accuracy of a wearable sensor vest for real-time monitoring of physiological responses to treadmill exercise. Ten subjects in standard firefighter ensembles, treadmill exercising at 50% VO(2) max, had heart rate (HR), respiratory rate (RR), skin temperature (T(sk)), oxygen saturation (SaO(2)), tidal volume (V(T)), and minute ventilation (V(E)) recorded concurrently by a wearable plethysmographic sensor vest and standard laboratory physiological monitoring equipment for comparison. A high degree of correlation was noted for most of the measured variables [HR (r = 0.99), RR (r = 0.98), T(sk) (r = 0.98), V(E) (r = 0.88), and SaO(2) (r = 0.79)]. V(T) (r = 0.60) had a moderate correlation, although a paired differences analysis showed a mean paired difference of -0.03 L. This mean paired difference represents a 1.92% variation for V(T). Data from the wearable sensor vest is comparable to data captured from standard laboratory physiological monitoring equipment on subjects wearing standard firefighter ensembles while exercising at a moderate work rate. This study demonstrates the accuracy of the wearable sensor technology for these physiological parameters under these conditions and suggests that it could be useful for actual field studies of firefighters in traditional firefighting gear.


Assuntos
Monitorização Fisiológica/instrumentação , Exposição Ocupacional/análise , Estresse Fisiológico , Adulto , Feminino , Frequência Cardíaca , Humanos , Masculino , Monitorização Fisiológica/métodos , Exposição Ocupacional/prevenção & controle , Oxigênio/metabolismo , Taxa Respiratória , Temperatura Cutânea , Volume de Ventilação Pulmonar
15.
Aviat Space Environ Med ; 74(1): 37-46, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12546297

RESUMO

BACKGROUND: A negative fluid balance during bed rest (BR) is accompanied by decreased plasma volume (PV) which contributes to cardiovascular deconditioning. HYPOTHESIS: We hypothesized that increasing dietary sodium while controlling fluid intake would increase plasma osmolality (POSM), stimulate fluid conserving hormones, and reduce fluid/electrolyte (F/E) losses during BR; conversely, decreasing dietary sodium would decrease POSM, suppress fluid conserving hormones, and increase F/E losses. METHODS: We controlled fluid intake (30 ml x kg(-1) x d(-1)) in 17 men who consumed either a 4.0 +/- 0.06 g x d(-1) (174 mmol x d(-1)) (CONT; n = 6), 1.0 +/- 0.02 g x d(-1) (43 mmol x d(-1)) (LS; n = 6), or 10.0 +/- 0.04 g x d(-1) (430 mmol x d(-1)) (HS; n = 5) sodium diet before, during, and after 21 d of 6 degrees head-down BR. PV, total body water, urine volume and osmolality, POSM, and F/E controlling hormone concentrations were measured. RESULTS: In HS subjects, plasma renin activity (-92%), plasma/urinary aldosterone (-59%; -64%), and PV (-15.0%; 6.0 ml x kg(-1); p < 0.05) decreased while plasma atrial natriuretic peptide (+34%) and urine antidiuretic hormone (+24%) increased during BR (p < 0.05) compared with CONT. In LS, plasma renin activity (+166%), plasma aldosterone (+167%), plasma antidiuretic hormone (+19%), and urinary aldosterone (+335%) increased with no change in PV compared with CONT (p < 0.05). Total body water did not change in any of the subjects. CONCLUSIONS: Contrary to our hypothesis, increasing dietary sodium while controlling fluid intake during BR resulted in a greater loss of PV compared with the CONT subjects. Reducing dietary sodium while controlling fluid intake did not alter the PV response during BR compared with CONT subjects.


Assuntos
Repouso em Cama , Sódio na Dieta/administração & dosagem , Equilíbrio Hidroeletrolítico/efeitos dos fármacos , Equilíbrio Hidroeletrolítico/fisiologia , Adulto , Análise de Variância , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Água Corporal/fisiologia , Interpretação Estatística de Dados , Hormônios/sangue , Hormônios/urina , Humanos , Masculino , Concentração Osmolar , Volume Plasmático/efeitos dos fármacos , Volume Plasmático/fisiologia , Sódio/urina
16.
Med Sci Sports Exerc ; 34(9): 1446-53, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12218737

RESUMO

PURPOSE: Supine, moderate exercise is ineffective in maintaining orthostatic tolerance after bed rest (BR). Our purpose was to test the hypothesis that adding an orthostatic stress during exercise would maintain orthostatic function after BR. METHODS: Seven healthy men completed duplicate 15-d 6 degrees head-down tilt BR using a crossover design. During one BR, subjects did not exercise (CON). During another BR, subjects exercised for 40 min.d(-1) on a supine treadmill against 50-60 mm Hg LBNP (EX). Exercise training consisted of an interval exercise protocol of 2- to 3-min intervals alternating between 41 and 65% (.)VO(2max). Before and after BR, an LBNP tolerance test was performed in which the LBNP chamber was decompressed in 10-mm Hg stages every 3 min until presyncope. RESULTS: LBNP tolerance, as assessed by the cumulative stress index (CSI) decreased after BR in both the CON (830 +/- 144, pre-BR vs 524 +/- 56 mm Hg.min, post-BR) and the EX (949 +/- 118 pre-BR vs 560 +/- 44 mm Hg.min, post-BR) conditions. However, subtolerance (0 to -50 mm Hg LBNP) heart rates were lower and systolic blood pressures were better maintained after BR in the EX condition compared with CON. CONCLUSION: Moderate exercise performed against LBNP simulating an upright 1-g environment failed to protect orthostatic tolerance after 15 d of BR.


Assuntos
Exercício Físico/fisiologia , Gravitação , Pressão Negativa da Região Corporal Inferior , Adulto , Análise de Variância , Repouso em Cama , Fenômenos Biomecânicos , Catecolaminas/sangue , Estudos Cross-Over , Humanos , Masculino , Aptidão Física , Decúbito Dorsal , Ausência de Peso
17.
J Appl Physiol (1985) ; 92(5): 2026-34, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11960954

RESUMO

Two potential mechanisms, reduced skin blood flow (SBF) and sweating rate (SR), may be responsible for elevated intestinal temperature (T(in)) during exercise after bed rest and spaceflight. Seven men underwent 13 days of 6 degrees head-down bed rest. Pre- and post-bed rest, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-bed rest supine peak exercise capacity) in a thermoneutral room. After bed rest, T(in) was elevated at rest (+0.31 +/- 0.12 degrees C) and at the end of exercise (+0.33 +/- 0.07 degrees C). Percent increase in SBF during exercise was less after bed rest (211 +/- 53 vs. 96 +/- 31%; P < or = 0.05), SBF/T(in) threshold was greater (37.09 +/- 0.16 vs. 37.33 +/- 0.13 degrees C; P < or = 0.05), and slope of SBF/T(in) tended to be reduced (536 +/- 184 vs. 201 +/- 46%/ degrees C; P = 0.08). SR/T(in) threshold was delayed (37.06 +/- 0.11 vs. 37.34 +/- 0.06 degrees C; P < or = 0.05), but the slope of SR/T(in) (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg x min-1 x cm-2 x degrees C-1) and total sweat loss (0.42 +/- 0.06 vs. 0.44 +/- 0.08 kg) were not changed. The higher resting and exercise T(in) and delayed onset of SBF and SR suggest a centrally mediated elevation in the thermoregulatory set point during bed rest exposure.


Assuntos
Repouso em Cama , Regulação da Temperatura Corporal/fisiologia , Esforço Físico/fisiologia , Pele/irrigação sanguínea , Sudorese/fisiologia , Adulto , Pressão Sanguínea , Índice de Massa Corporal , Temperatura Corporal/fisiologia , Volume de Eritrócitos/fisiologia , Teste de Esforço , Frequência Cardíaca/fisiologia , Hematócrito , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Volume Plasmático/fisiologia , Valores de Referência , Fluxo Sanguíneo Regional/fisiologia , Fenômenos Fisiológicos da Pele , Temperatura Cutânea/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA