Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Histopathology ; 84(1): 6-17, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37872108

RESUMO

Advancements in the classification of lung adenocarcinoma have resulted in significant changes in pathological reporting. The eighth edition of the tumour-node-metastasis (TNM) staging guidelines calls for the use of invasive size in staging in place of total tumour size. This shift improves prognostic stratification and requires a more nuanced approach to tumour measurements in challenging situations. Similarly, the adoption of new grading criteria based on the predominant and highest-grade pattern proposed by the International Association for the Study of Lung Cancer (IASLC) shows improved prognostication, and therefore clinical utility, relative to previous grading systems. Spread through airspaces (STAS) is a form of tumour invasion involving tumour cells spreading through the airspaces, which has been highly researched in recent years. This review discusses updates in pathological T staging, adenocarcinoma grading and STAS and illustrates the utility and limitations of current concepts in lung adenocarcinoma.


Assuntos
Adenocarcinoma de Pulmão , Adenocarcinoma , Neoplasias Pulmonares , Humanos , Invasividade Neoplásica/patologia , Adenocarcinoma de Pulmão/patologia , Neoplasias Pulmonares/patologia , Adenocarcinoma/patologia , Prognóstico , Estadiamento de Neoplasias , Estudos Retrospectivos , Recidiva Local de Neoplasia/patologia
3.
Diagn Cytopathol ; 51(8): E242-E247, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37212382

RESUMO

Aspirates of mediastinal neoplasms pose a unique diagnostic challenge due to the overlapping histologic characteristics of mediastinal lesions and the morphologic similarities between mediastinal neoplasms and those originating at other sites. Presented here is the first reported description of the cytomorphologic features of adenocarcinoma NOS of the thymus in aspirate and pleural effusion specimens. The morphologic similarities between thymic and metastatic adenocarcinomas and variable immunohistochemical staining patterns of thymic epithelial neoplasms underscore the importance of pathology-radiology correlation and the careful consideration of the clinical context in the interpretation of cytology specimens.


Assuntos
Adenocarcinoma , Neoplasias do Mediastino , Neoplasias do Timo , Humanos , Neoplasias do Mediastino/diagnóstico , Neoplasias do Timo/patologia , Timo/patologia , Adenocarcinoma/patologia , Mediastino/patologia
4.
JACC Clin Electrophysiol ; 9(4): 497-507, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36752460

RESUMO

BACKGROUND: Improved ablation catheter-tissue contact results in more effective ablation lesions. Respiratory motion causes catheter instability, which impacts durable pulmonary vein isolation (PVI). OBJECTIVES: This study sought to evaluate the safety and efficacy of a novel ablation strategy involving prolonged periods of apneic oxygenation during PVI. METHODS: We conducted a multicenter, prospective controlled study of 128 patients (mean age 63 ± 11 years; 37% women) with paroxysmal atrial fibrillation undergoing PVI. Patients underwent PVI under general anesthesia using serial 4-minute runs of apneic oxygenation (apnea group; n = 64) or using standard ventilation settings (control group; n = 64). Procedural data, arterial blood gas samples, catheter position coordinates, and ablation lesion characteristics were collected. RESULTS: Baseline characteristics between the 2 groups were similar. Catheter stability was significantly improved in the apnea group, as reflected by a decreased mean catheter displacement (1.55 ± 0.97 mm vs 2.25 ± 1.13 mm; P < 0.001) and contact force SD (4.9 ± 1.1 g vs 5.2 ± 1.5 g; P = 0.046). The percentage of lesions with a mean catheter displacement >2 mm was significantly lower in the apnea group (22% vs 44%; P < 0.001). Compared with the control group, the total ablation time to achieve PVI was reduced in the apnea group (18.8 ± 6.9 minutes vs 23.4 ± 7.8 minutes; P = 0.001). There were similar rates of first-pass PVI, acute PV reconnections and dormant PV reconnections between the two groups. CONCLUSIONS: A novel strategy of performing complete PVI during apneic oxygenation results in improved catheter stability and decreased ablation times without adverse events. (Radiofrequency Ablation of Atrial Fibrillation Under Apnea; NCT04170894).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Veias Pulmonares/cirurgia , Estudos Prospectivos , Apneia/cirurgia , Apneia/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
Pacing Clin Electrophysiol ; 46(6): 504-509, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36660967

RESUMO

Atrial premature contractions (PACs) that block at the atrio-ventricular (AV) nodal level and occurring in a bigeminal frequency are recognized as a cause of symptomatic bradycardia. Appropriate suppression of the PACs often results in restoration of a regular rhythm with resolution of bradycardia-related symptoms. We report a series of three patients with non-conducted bigeminal PACs arising from the mitral annulus that resulted in symptomatic bradycardia and who were referred for consideration of cardiac pacing. Focal ablation suppressed PACs restoring a normal heart rate and resolution of symptoms without resorting to cardiac pacing.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Humanos , Bradicardia , Átrios do Coração/cirurgia , Complexos Atriais Prematuros/cirurgia , Complexos Atriais Prematuros/complicações , Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos
6.
Europace ; 25(2): 586-590, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36575941

RESUMO

AIMS: Same-day discharge (SDD) is safe for patients undergoing electrophysiology procedures. There is no existing data regarding SDD for patients undergoing transvenous lead extraction (TLE). We report our experience with SDD for patients undergoing TLE. METHODS AND RESULTS: The study group included patients undergoing TLE between February 2020 and July 2021 without an infectious indication. A modified SDD protocol for device implants/ablations was applied to TLE patients. Patient characteristics, extraction details, outcomes, and complications were reviewed. Of 239 patients undergoing TLE, 210 were excluded (94 infections and 116 did not meet SDD criteria). Of the remaining 29 patients, seven stayed due to patient preference and 22 were discharged home the same day. The SDD group had an average age of 65.9 ± 12 (47-84), 41% female, and LVEF of 52.2 ± 18% (10-80). The indication for TLE was malfunction (20), upgrade (4), advisory lead (2), and magnetic resonance imaging compatibility (1). Extractions included four implantable cardioverter-defibrillators (ICDs), 17 pacemakers (PPM), and one cardiac resynchronization therapy (CRT)-P system. The leads were 9.6 years (1.5-21.7) old, and 1.8 leads were removed per patient (1-3); the lead extraction difficulty (LED) score was 11.6 ± 7. Twenty underwent cardiovascular implantable electronic device (CIED) re-implantation (2 ICD, 3 CRT-D, 13 PPM, and 2 CRT-P). For CIED re-implants, patients sent a remote transmission the next day, and all patients received a next-day call. There were no procedure or device-related issues, morbidities, or mortalities in the 30 days after discharge. CONCLUSION: Same-day discharge after TLE for non-infectious aetiologies is safe and feasible in a select group of patients with early procedure completion who meet strict SDD criteria.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Alta do Paciente , Estudos de Viabilidade , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
7.
J Arrhythm ; 38(5): 813-816, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36237867

RESUMO

Following ablation on the RV moderator band for suppression of monomorphic PVCs, recurrent VT and VF were triggered by the same PVC at shorter coupling intervals. This is likely a pro arrhythmic effect of ablation on the moderator band.

8.
Cancers (Basel) ; 14(8)2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35454918

RESUMO

Thymic epithelial neoplasms are rare tumors that constitute the majority of anterior mediastinal masses. They are classified as thymomas, thymic carcinomas, and thymic neuroendocrine neoplasms. Biopsy diagnosis is not common, and most tumors are surgically resected. Biopsy, including cytology, is indicated when a non-surgical entity is suspected or in cases of locally advanced disease. Smears of thymomas consist of round or spindle epithelial cells admixed with varying amounts of lymphocytes depending on the type of thymoma. Smears of thymic carcinoma and thymic neuroendocrine neoplasms are often indistinguishable from corresponding tumor types from other organs. Accurate cytological diagnosis can be difficult due to the histological diversity of thymomas, as well as the morphological features that certain thymic tumors share with similar tumors from other organs. However, fine needle aspiration (FNA) of anterior mediastinal masses can provide clinically actionable information and can be used to determine whether lesions require surgical, systemic, or local noninvasive treatments. Ancillary studies, namely, immunocytochemical stains, flow cytometry, and radiology, are important tools in the evaluation of thymic aspirates. This review discusses the utility and limitations of thymic FNAs and illustrates the diagnostic features and pitfalls of these specimens.

9.
J Am Acad Dermatol ; 85(5): 1073-1090, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33940098

RESUMO

Primary cutaneous T-cell lymphomas (CTCLs) are defined as lymphomas with a T-cell phenotype that present in the skin without evidence of systemic or extracutaneous disease at initial presentation. CTCLs other than mycosis fungoides and Sézary syndrome (SS) account for approximately one third of CTCLs and encompass a heterogenous group of non-Hodgkin lymphomas, ranging from indolent lymphoproliferative disorders to aggressive malignancies with a poor prognosis. The spectrum of CTCLs continues to broaden as new provisional entities are classified. Given the morphologic and histologic overlap among CTCLs and other diagnoses, a thorough clinical history, physical evaluation, and clinicopathologic correlation are essential in the work up and diagnosis of these rare entities. This article will summarize the epidemiologic, clinical, pathologic, and diagnostic features of CTCLs other than mycosis fungoides and SS.


Assuntos
Linfoma Cutâneo de Células T , Micose Fungoide , Síndrome de Sézary , Neoplasias Cutâneas , Humanos , Linfoma Cutâneo de Células T/diagnóstico , Micose Fungoide/diagnóstico , Síndrome de Sézary/diagnóstico , Pele , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/epidemiologia
11.
Acad Pathol ; 7: 2374289520958172, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33088909

RESUMO

The following fictional case is intended as a learning tool within the Pathology Competencies for Medical Education (PCME), a set of national standards for teaching pathology. These are divided into three basic competencies: Disease Mechanisms and Processes, Organ System Pathology, and Diagnostic Medicine and Therapeutic Pathology. For additional information, and a full list of learning objectives for all three competencies, see http://journals.sagepub.com/doi/10.1177/2374289517715040.1.

12.
J Cardiovasc Electrophysiol ; 31(10): 2668-2676, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32618396

RESUMO

BACKGROUND: Idiopathic ventricular arrhythmias (IVAs) from the left ventricular (LV) summit may be successfully ablated from the distal great cardiac vein (dGCV). Using a 12-lead electrocardiogram (ECG) to localize IVAs that can be ablated from the dGCV is valuable for ablation planning. OBJECTIVE: To determine if a "w" wave, a notch in the Q wave in lead I, and other ECG features can identify IVAs that can be successfully ablated from the dGCV. METHODS: We reviewed outflow tract premature ventricular contraction (PVC) ablations performed at two centers between September 2010 and June 2018. Successful PVC ablations, in which the PVCs were mapped from the right ventricular outflow tract, coronary cusps, commissures, endocardial LV, and the coronary venous system including the dGCV were included. ECG characteristics were compared between patients with successful ablations in the dGCV and non-dGCV sites. RESULTS: Of the 120 patients (age 56.8 ± 13.8 years, 45% female) that met the inclusion criteria, the dGCV was the successful ablation site in 18 patients (15%). Multivariate analysis with binary logistic regression showed that a "w" in lead I in combination with an early precordial pattern break and a maximum deflection index (MDI) ≥ 0.5 had sensitivity and specificity for a successful ablation in the dGCV of 94.4% and 96.1%, respectively. CONCLUSION: Combining a "w" wave in lead I with an early precordial pattern break and an MDI ≥ 0.5 is highly sensitive and specific for identifying the dGCV as a successful ablation site for PVCs.


Assuntos
Ablação por Cateter , Seio Coronário , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
13.
Heart Rhythm ; 17(12): 2023-2028, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32454218

RESUMO

BACKGROUND: The Micra leadless pacemaker (MLP) has proven to be an effective alternative to a traditional transvenous pacemaker (TVP). However, there has been concern about using the MLP in frail elderly patients because of the size of the implant sheath and perceived risk of perforation. OBJECTIVES: The objectives of this study were to report the safety of the MLP and compare MPLs with TVPs in the very elderly. METHODS: All patients 85 years and older who received an MLP or a single-chamber TVP across 6 hospitals in the Northwell Health system from December 2015 to November 2019 were included. Demographic characteristics, procedural details, and procedure-related complications were reviewed. RESULTS: Over 4 years, 564 patients underwent MLP implantation. During this time, 183 MLPs and 119 TVPs were implanted in patients 85 years and older. The mean age was 89.7 ± 3.4 years, and 47.4% were men. MLP implantation was successful in all but 3 patients (98.4% success rate). There was no difference in procedure-related complications (3.3% vs 5.9%; P = .276). Complications included 5 (2.7%) access site hematomas in the MLP group, 3 (2.5%) in the TVP group, 1 (0.5 vs 0.8%) pericardial effusion in each group, and 3 (2.5%) acute lead dislodgments (<24 hours) in the TVP group. MLP implantation resulted in a significantly shorter mean procedure time (35.7 ± 23.0 minutes vs 62.3 ± 31.5 minutes, P < .001). CONCLUSION: In a large multicenter study of patients 85 years and older, MLP implantation (1) was successful in 98.4% of patients, (2) was safe with no difference in procedure-related complications compared to the TVP group, and (3) resulted in significantly shorter procedure times.


Assuntos
Bradicardia/terapia , Frequência Cardíaca/fisiologia , Marca-Passo Artificial , Fatores Etários , Idoso de 80 Anos ou mais , Bradicardia/fisiopatologia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Am J Cardiol ; 125(12): 1851-1855, 2020 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-32307087

RESUMO

The implantable loop recorder (ILR) is a valuable tool used in the evaluation of syncope, arrhythmia, and cryptogenic stroke. In the inpatient setting, ILRs are routinely implanted in the electrophysiology (EP) lab despite the low complication rate. The purpose of this study was to evaluate the safety, feasibility, and cost of implanting ILRs at the patient's bedside by both electrophysiologists and advanced practice providers (APPs). This was a single center, retrospective study of consecutive ILR implantations performed from February 2018 to May 2019. We examined 3 groups: implantations in the EP lab by electrophysiologists (EP Lab/MD), implantations at the bedside by electrophysiologists (Floor/MD), and implantations at the bedside by APPs (Floor/APP). Over 15 months, 152 patients underwent ILR implantation: 48 in the EP Lab/MD group, 57 in the Floor/MD group, and 47 in the Floor/APP group. The procedure duration was longer in the Floor/APP group (14.2 ± 5.9 minutes) compared with the EP Lab/MD and Floor/MD groups (6.8 ± 4.3 minutes, 9.1 ± 4.9 minutes, p <0.001). The overall complication rate was low (2.6%) with no differences between the groups (p = 0.83). The calculated costs per implant for the EP Lab/MD group, Floor/MD group, and Floor/APP group were $482.05, $162.82, and $73.08, respectively.


Assuntos
Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Implantação de Prótese/métodos , Telemetria/instrumentação , Idoso , Eletrofisiologia Cardíaca , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Retrospectivos
15.
Circ Arrhythm Electrophysiol ; 13(6): e008662, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32347743

RESUMO

BACKGROUND: The novel SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) is responsible for the global coronavirus disease 2019 pandemic. Small studies have shown a potential benefit of chloroquine/hydroxychloroquine±azithromycin for the treatment of coronavirus disease 2019. Use of these medications alone, or in combination, can lead to a prolongation of the QT interval, possibly increasing the risk of Torsade de pointes and sudden cardiac death. METHODS: Hospitalized patients treated with chloroquine/hydroxychloroquine±azithromycin from March 1 to the 23 at 3 hospitals within the Northwell Health system were included in this prospective, observational study. Serial assessments of the QT interval were performed. The primary outcome was QT prolongation resulting in Torsade de pointes. Secondary outcomes included QT prolongation, the need to prematurely discontinue any of the medications due to QT prolongation, and arrhythmogenic death. RESULTS: Two hundred one patients were treated for coronavirus disease 2019 with chloroquine/hydroxychloroquine. Ten patients (5.0%) received chloroquine, 191 (95.0%) received hydroxychloroquine, and 119 (59.2%) also received azithromycin. The primary outcome of torsade de pointes was not observed in the entire population. Baseline corrected QT interval intervals did not differ between patients treated with chloroquine/hydroxychloroquine (monotherapy group) versus those treated with combination group (chloroquine/hydroxychloroquine and azithromycin; 440.6±24.9 versus 439.9±24.7 ms, P=0.834). The maximum corrected QT interval during treatment was significantly longer in the combination group versus the monotherapy group (470.4±45.0 ms versus 453.3±37.0 ms, P=0.004). Seven patients (3.5%) required discontinuation of these medications due to corrected QT interval prolongation. No arrhythmogenic deaths were reported. CONCLUSIONS: In the largest reported cohort of coronavirus disease 2019 patients to date treated with chloroquine/hydroxychloroquine±azithromycin, no instances of Torsade de pointes, or arrhythmogenic death were reported. Although use of these medications resulted in QT prolongation, clinicians seldomly needed to discontinue therapy. Further study of the need for QT interval monitoring is needed before final recommendations can be made.


Assuntos
Arritmias Cardíacas/induzido quimicamente , Azitromicina/efeitos adversos , Betacoronavirus , Cloroquina/efeitos adversos , Infecções por Coronavirus/tratamento farmacológico , Eletrocardiografia/efeitos dos fármacos , Hidroxicloroquina/efeitos adversos , Pneumonia Viral/tratamento farmacológico , Antibacterianos/efeitos adversos , Antibacterianos/uso terapêutico , Antimaláricos/efeitos adversos , Antimaláricos/uso terapêutico , Arritmias Cardíacas/complicações , Arritmias Cardíacas/epidemiologia , Azitromicina/uso terapêutico , COVID-19 , Cloroquina/uso terapêutico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/fisiopatologia , Quimioterapia Combinada , Seguimentos , Humanos , Hidroxicloroquina/uso terapêutico , Incidência , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/fisiopatologia , Estudos Prospectivos , Fatores de Risco , SARS-CoV-2 , Estados Unidos/epidemiologia
17.
18.
J Cardiovasc Electrophysiol ; 31(4): 860-867, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32048776

RESUMO

INTRODUCTION: The need for transvenous lead extractions due to cardiac implantable electronic device (CIED)-related infections continues to rise. Current guidelines recommend complete device removal in the setting of an active infection, which can be challenging in pacemaker-dependent patients. METHODS: We retrospectively reviewed all leadless pacemaker implants between January 2018 and November 2019 and identified a subset of patients who had undergone a concomitant CIED extraction in the setting of an active infection. Baseline characteristics, procedural details, and clinical follow-ups were recorded. RESULTS: Seventeen patients received a leadless pacemaker during the same procedure as the CIED extraction. There were no procedural complications. All patients were being treated for an active CIED infection at the time of the procedure. Fourteen patients (82.4%) were completely pacemaker-dependent and four patients (23.5%) had positive blood cultures at the time of the leadless pacemaker implantation. During a median follow-up of 143 days (interquartile range: 57, 181 days), there were no recurrent infections. CONCLUSION: Simultaneous leadless pacemaker implantation and CIED extraction are safe and feasible in the setting of an active infection. This strategy may be particularly useful in patients that are pacemaker-dependent.


Assuntos
Arritmias Cardíacas/terapia , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/cirurgia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Implantação de Prótese/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA