Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Diabetes Technol Ther ; 26(3): 176-183, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37955644

RESUMO

Introduction: Diabetic ketoacidosis (DKA) at diagnosis is associated with short- and long-term complications. We assessed the relationship between DKA status and hemoglobin A1c (A1c) levels in the first year following type 1 diabetes (T1D) diagnosis. Research Design and Methods: The Pilot Teamwork, Targets, Technology, and Tight Control (4T) study offered continuous glucose monitoring to youth with T1D within 1 month of diagnosis. A1c levels were compared between historical (n = 271) and Pilot 4T (n = 135) cohorts stratified by DKA status at diagnosis (DKA: historical = 94, 4T = 67 versus without DKA: historical = 177, 4T = 68). A1c was evaluated using locally estimated scatter plot smoothing. Change in A1c from 4 to 12 months postdiagnosis was evaluated using a linear mixed model. Results: Median age was 9.7 (interquartile range [IQR]: 6.6, 12.7) versus 9.7 (IQR: 6.8, 12.7) years, 49% versus 47% female, 44% versus 39% non-Hispanic White in historical versus Pilot 4T. In historical and 4T cohorts, DKA at diagnosis demonstrated higher A1c at 6 (0.5% [95% confidence interval (CI): 0.21-0.79; P < 0.01] and 0.38% [95% CI: 0.02-0.74; P = 0.04], respectively), and 12 months (0.62% [95% CI: -0.06 to 1.29; P = 0.07] and 0.39% [95% CI: -0.32 to 1.10; P = 0.29], respectively). The highest % time in range (TIR; 70-180 mg/dL) was seen between weeks 15-20 (69%) versus 25-30 (75%) postdiagnosis for youth with versus without DKA in Pilot 4T, respectively. Conclusions: Pilot 4T improved A1c outcomes versus the historical cohort, but those with DKA at diagnosis had persistently elevated A1c throughout the study and intensive diabetes management did not mitigate this difference. DKA prevention at diagnosis may translate into better glycemic outcomes in the first-year postdiagnosis. Clinical Trial Registration: clinicaltrials.gov: NCT04336969.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Feminino , Humanos , Masculino , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/etiologia , Hemoglobinas Glicadas , Insulina/uso terapêutico , Projetos Piloto
2.
J Clin Endocrinol Metab ; 109(1): 57-67, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37572381

RESUMO

CONTEXT: The value of continuous glucose monitoring (CGM) for monitoring autoantibody (AAB)-positive individuals in clinical trials for progression of type 1 diabetes (T1D) is unknown. OBJECTIVE: Compare CGM with oral glucose tolerance test (OGTT)-based metrics in prediction of T1D. METHODS: At academic centers, OGTT and CGM data from multiple-AAB relatives were evaluated for associations with T1D diagnosis. Participants were multiple-AAB-positive individuals in a TrialNet Pathway to Prevention (TN01) CGM ancillary study (n = 93). The intervention was CGM for 1 week at baseline, 6 months, and 12 months. Receiver operating characteristic (ROC) curves of CGM and OGTT metrics for prediction of T1D were analyzed. RESULTS: Five of 7 OGTT metrics and 29/48 CGM metrics but not HbA1c differed between those who subsequently did or did not develop T1D. ROC area under the curve (AUC) of individual CGM values ranged from 50% to 69% and increased when adjusted for age and AABs. However, the highest-ranking metrics were derived from OGTT: 4/7 with AUC ∼80%. Compared with adjusted multivariable models using CGM data, OGTT-derived variables, Index60 and DPTRS (Diabetes Prevention Trial-Type 1 Risk Score), had higher discriminative ability (higher ROC AUC and positive predictive value with similar negative predictive value). CONCLUSION: Every 6-month CGM measures in multiple-AAB-positive individuals are predictive of subsequent T1D, but less so than OGTT-derived variables. CGM may have feasibility advantages and be useful in some settings. However, our data suggest there is insufficient evidence to replace OGTT measures with CGM in the context of clinical trials.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/diagnóstico , Teste de Tolerância a Glucose , Glicemia/metabolismo , Autoanticorpos , Automonitorização da Glicemia , Monitoramento Contínuo da Glicose
3.
Diabetes Care ; 46(5): 1005-1013, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36920087

RESUMO

OBJECTIVE: Previous studies showed that inhibiting lymphocyte costimulation reduces declining ß-cell function in individuals newly diagnosed with type 1 diabetes. We tested whether abatacept would delay or prevent progression of type 1 diabetes from normal glucose tolerance (NGT) to abnormal glucose tolerance (AGT) or to diabetes and the effects of treatment on immune and metabolic responses. RESEARCH DESIGN AND METHODS: We conducted a phase 2, randomized, placebo-controlled, double-masked trial of abatacept in antibody-positive participants with NGT who received monthly abatacept/placebo infusions for 12 months. The end point was AGT or diabetes, assessed by oral glucose tolerance tests. RESULTS: A total of 101 participants received abatacept and 111 placebo. Of these, 81 (35 abatacept and 46 placebo) met the end point of AGT or type 1 diabetes diagnosis (hazard ratio 0.702; 95% CI 0.452, 1.09; P = 0.11) The C-peptide responses to oral glucose tolerance tests were higher in the abatacept arm (P < 0.03). Abatacept reduced the frequency of inducible T-cell costimulatory (ICOS)+ PD1+ T-follicular helper (Tfh) cells during treatment (P < 0.0001), increased naive CD4+ T cells, and also reduced the frequency of CD4+ regulatory T cells (Tregs) from the baseline (P = 0.0067). Twelve months after treatment, the frequency of ICOS+ Tfh, naive CD4+ T cells, and Tregs returned to baseline. CONCLUSIONS: Although abatacept treatment for 1 year did not significantly delay progression to glucose intolerance in at-risk individuals, it impacted immune cell subsets and preserved insulin secretion, suggesting that costimulation blockade may modify progression of type 1 diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Abatacepte/uso terapêutico , Abatacepte/farmacologia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Imunossupressores , Linfócitos T Reguladores , Glucose/uso terapêutico
4.
Diabetes Care ; 46(3): 526-534, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730530

RESUMO

OBJECTIVE: Continuous glucose monitoring (CGM) parameters may identify individuals at risk for progression to overt type 1 diabetes. We aimed to determine whether CGM metrics provide additional insights into progression to clinical stage 3 type 1 diabetes. RESEARCH DESIGN AND METHODS: One hundred five relatives of individuals in type 1 diabetes probands (median age 16.8 years; 89% non-Hispanic White; 43.8% female) from the TrialNet Pathway to Prevention study underwent 7-day CGM assessments and oral glucose tolerance tests (OGTTs) at 6-month intervals. The baseline data are reported here. Three groups were evaluated: individuals with 1) stage 2 type 1 diabetes (n = 42) with two or more diabetes-related autoantibodies and abnormal OGTT; 2) stage 1 type 1 diabetes (n = 53) with two or more diabetes-related autoantibodies and normal OGTT; and 3) negative test for all diabetes-related autoantibodies and normal OGTT (n = 10). RESULTS: Multiple CGM metrics were associated with progression to stage 3 type 1 diabetes. Specifically, spending ≥5% time with glucose levels ≥140 mg/dL (P = 0.01), ≥8% time with glucose levels ≥140 mg/dL (P = 0.02), ≥5% time with glucose levels ≥160 mg/dL (P = 0.0001), and ≥8% time with glucose levels ≥160 mg/dL (P = 0.02) were all associated with progression to stage 3 disease. Stage 2 participants and those who progressed to stage 3 also exhibited higher mean daytime glucose values; spent more time with glucose values over 120, 140, and 160 mg/dL; and had greater variability. CONCLUSIONS: CGM could aid in the identification of individuals, including those with a normal OGTT, who are likely to rapidly progress to stage 3 type 1 diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Feminino , Adolescente , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glicemia/metabolismo , Automonitorização da Glicemia , Glucose/uso terapêutico , Autoanticorpos
5.
SLAS Technol ; 27(1): 26-31, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35058202

RESUMO

Screening for islet autoantibody markers to identify individuals who are at high risk for developing type 1 diabetes (T1D), often years in advance of clinical symptoms, is both a challenge and a necessity. Identifying high-risk individuals not only reduces hospitalization and rates of life-threatening diabetes ketoacidosis (DKA), but also directs enrollment into prevention trials that require patients who are in the early stages of disease. Here we describe an automated high-throughput multiplex islet autoantibody assay that integrates antibody detection by agglutination-PCR (ADAP) chemistry on the Hamilton Microlab STAR liquid handling platform. The automated system features on-deck thermal cycling and plate sealing to minimize the level of human intervention. The automated multiplex ADAP T1D assay performed similarly to that of manual methods using two distinct cohorts of clinical specimens obtained from the Lucile Packard Children's Hospital at Stanford University and the 2018 Islet Autoantibody Standardization Program (IASP). Notably, the automated assay requires only 4 µL of serum sample for the simultaneous analysis of GAD, IA-2 and insulin autoantibodies. Up to 96 samples may be processed in as little as 3 hours, and the only user intervention required is to transfer a final sealed 96-well plate containing PCR amplicons onto a quantitative PCR (RT-qPCR) instrument for quantification. The automated system is particularly well suited for large-scale analysis of islet autoantibodies in a reproducible, timely, and cost-effective manner.


Assuntos
Diabetes Mellitus Tipo 1 , Aglutinação , Autoanticorpos , Automação , Criança , Diabetes Mellitus Tipo 1/diagnóstico , Humanos , Reação em Cadeia da Polimerase Multiplex
6.
Diabetes Technol Ther ; 24(3): 157-166, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34780306

RESUMO

Background: Hybrid Closed-Loop (HCL) systems aid individuals with type 1 diabetes in improving glycemic control; however, sustained use over time has not been consistent for all users. This study developed and validated prognostic models for successful 12-month use of the first commercial HCL system based on baseline and 1- or 3-month data. Methods and Materials: Data from participants at the Barbara Davis Center (N = 85) who began use of the MiniMed 670G HCL were used to develop prognostic models using logistic regression and Lasso model selection. Candidate factors included sex, age, duration of diabetes, baseline hemoglobin A1c (HbA1c), race, ethnicity, insurance status, history of insulin pump and continuous glucose monitor use, 1- or 3-month Auto Mode use, boluses per day, and time in range (TIR; 70-180 mg/dL), and scores on behavioral questionnaires. Successful use of HCL was predefined as Auto Mode use ≥60%. The 3-month model was then externally validated against a sample from Stanford University (N = 55). Results: Factors in the final model included baseline HbA1c, sex, ethnicity, 1- or 3-month Auto Mode use, Boluses per Day, and TIR. The 1- and 3-month prognostic models had very good predictive ability with area under the curve values of 0.894 and 0.900, respectively. External validity was acceptable with an area under the curve of 0.717. Conclusions: Our prognostic models use clinically accessible baseline and early device-use factors to identify risk for failure to succeed with 670G HCL technology. These models may be useful to develop targeted interventions to promote success with new technologies.


Assuntos
Diabetes Mellitus Tipo 1 , Pâncreas Artificial , Adolescente , Glicemia , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Adulto Jovem
7.
JCI Insight ; 6(21)2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34747368

RESUMO

BackgroundIL-6 receptor (IL-6R) signaling drives development of T cell populations important to type 1 diabetes pathogenesis. We evaluated whether blockade of IL-6R with monoclonal antibody tocilizumab would slow loss of residual ß cell function in newly diagnosed type 1 diabetes patients.MethodsWe conducted a multicenter, randomized, placebo-controlled, double-blind trial with tocilizumab in new-onset type 1 diabetes. Participants were screened within 100 days of diagnosis. Eligible participants were randomized 2:1 to receive 7 monthly doses of tocilizumab or placebo. The primary outcome was the change from screening in the mean AUC of C-peptide collected during the first 2 hours of a mixed meal tolerance test at week 52 in pediatric participants (ages 6-17 years).ResultsThere was no statistical difference in the primary outcome between tocilizumab and placebo. Immunophenotyping showed reductions in downstream signaling of the IL-6R in T cells but no changes in CD4 memory subsets, Th17 cells, Tregs, or CD4+ T effector cell resistance to Treg suppression. A DC subset decreased during therapy but regressed to baseline once therapy stopped. Tocilizumab was well tolerated.ConclusionTocilizumab reduced T cell IL-6R signaling but did not modulate CD4+ T cell phenotypes or slow loss of residual ß cell function in newly diagnosed individuals with type 1 diabetes.Trial RegistrationClinicalTrials.gov NCT02293837.FundingNIH National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) and National Institute of Allergy and Infectious Diseases (NIAID) UM1AI109565, UL1TR000004 from NIH/National Center for Research Resources (NCRR) Clinical and Translational Science Award (CTSA), NIH/NIDDK P30DK036836, NIH/NIDDK U01DK103266, NIH/NIDDK U01DK103266, 1UL1TR000064 from NIH/NCRR CTSA, NIH/National Center for Advancing Translational Sciences (NCATS) UL1TR001878, UL1TR002537 from NIH/CTSA; National Health and Medical Research Council Practitioner Fellowship (APP1136735), NIH/NIDDK U01-DK085476, NIH/CTSA UL1-TR002494, Indiana Clinical and Translational Science Institute Award UL1TR002529, Vanderbilt Institute for Clinical and Translational Research UL1TR000445. NIH/NCATS UL1TR003142, NIH/CTSA program UL1-TR002494, Veteran Affairs Administration, and 1R01AI132774.


Assuntos
Subpopulações de Linfócitos B/metabolismo , Diabetes Mellitus Tipo 1/genética , Receptores de Interleucina-6/antagonistas & inibidores , Adolescente , Criança , Diabetes Mellitus Tipo 1/patologia , Método Duplo-Cego , Feminino , Humanos , Masculino
8.
Lancet Diabetes Endocrinol ; 9(6): 336-349, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33933181

RESUMO

BACKGROUND: There are few long-term studies of interventions to reduce in low socioeconomic status children with overweight or obesity. The Stanford GOALS trial evaluated a 3-year, community-based, multi-level, multi-setting, multi-component (MMM) systems intervention, to reduce weight gain among low socioeconomic status, Latinx children with overweight or obesity. METHODS: We did a two-arm, parallel group, randomised, open-label, active placebo-controlled trial with masked assessment over 3 years. Families from low-income, primarily Latinx communities in Northern California, CA, USA, with 7-11-year-old children with overweight or obesity were randomly assigned to a MMM intervention or a Health Education (HE) comparison intervention. The MMM intervention included home environment changes and behavioural counselling, community after school team sports, and reports to primary health-care providers. The primary outcome was child BMI trajectory over three years. Secondary outcomes included one- and two-year changes in BMI. This trial is registered with ClinicalTrials.govNCT01642836. FINDINGS: Between July 13, 2012, and Oct 3, 2013, 241 families were recruited and randomly assigned to MMM (n=120) or HE (n=121). Children's mean age was 9·5 (SD 1·4) years, 134 (56%) were female and 107 (44%) were male, and 236 (98%) were Latinx. 238 (99%) children participated in year 1, 233 (97%) in year 2, and 227 (94%) in year 3 of follow-up assessments. In intention-to-treat analysis, over 3 years, the difference between intervention groups in BMI trajectory was not significant (mean adjusted difference -0·25 [95% CI -0·90 to 0·40] kg/m2; Cohen's d=0.10; p=0·45). Children in the MMM intervention group gained less BMI over 1 year than did children in the HE intervention group (-0·73 [-1·07 to -0·39] kg/m2, d=0.55); the same was true over 2 years (-0·63 [-1·13 to -0·14] kg/m2; d =0.33). No differential adverse events were observed. INTERPRETATION: The MMM intervention did not reduce BMI gain versus HE over 3 years but the effects over 1 and 2 years in this rigorous trial show the promise of this systems intervention approach for reducing weight gain and cardiometabolic risk factors in low socioeconomic status communities. FUNDING: US National Institutes of Health.


Assuntos
Obesidade Infantil/etnologia , Obesidade Infantil/terapia , Programas de Redução de Peso/métodos , Índice de Massa Corporal , California/epidemiologia , Criança , Participação da Comunidade , Exercício Físico/fisiologia , Feminino , Hispânico ou Latino/educação , Humanos , Masculino , Sobrepeso/etnologia , Sobrepeso/prevenção & controle , Sobrepeso/terapia , Planejamento de Assistência ao Paciente , Educação de Pacientes como Assunto/métodos , Obesidade Infantil/prevenção & controle , Pobreza/etnologia , Classe Social , Fatores Socioeconômicos , Esportes , Aumento de Peso/etnologia , Redução de Peso/etnologia
9.
PLoS One ; 15(11): e0242049, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33186361

RESUMO

Islet autoantibodies are predominantly measured by radioassay to facilitate risk assessment and diagnosis of type 1 diabetes. However, the reliance on radioactive components, large sample volumes and limited throughput renders radioassay testing costly and challenging. We developed a multiplex analysis platform based on antibody detection by agglutination-PCR (ADAP) for the sample-sparing measurement of GAD, IA-2 and insulin autoantibodies/antibodies in 1 µL serum. The assay was developed and validated in 7 distinct cohorts (n = 858) with the majority of the cohorts blinded prior to analysis. Measurements from the ADAP assay were compared to radioassay to determine correlation, concordance, agreement, clinical sensitivity and specificity. The average overall agreement between ADAP and radioassay was above 91%. The average clinical sensitivity and specificity were 96% and 97%. In the IASP 2018 workshop, ADAP achieved the highest sensitivity of all assays tested at 95% specificity (AS95) rating for GAD and IA-2 autoantibodies and top-tier performance for insulin autoantibodies. Furthermore, ADAP correctly identified 95% high-risk individuals with two or more autoantibodies by radioassay amongst 39 relatives of T1D patients tested. In conclusion, the new ADAP assay can reliably detect the three cardinal islet autoantibodies/antibodies in 1µL serum with high sensitivity. This novel assay may improve pediatric testing compliance and facilitate easier community-wide screening for islet autoantibodies.


Assuntos
Aglutinação/imunologia , Autoanticorpos/imunologia , Diabetes Mellitus Tipo 1/imunologia , Ilhotas Pancreáticas/imunologia , Adolescente , Adulto , Feminino , Glutamato Descarboxilase/imunologia , Humanos , Anticorpos Anti-Insulina/imunologia , Masculino , Programas de Rastreamento , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Adulto Jovem
10.
Diabetologia ; 63(3): 588-596, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31768570

RESUMO

AIMS/HYPOTHESIS: Young children who develop multiple autoantibodies (mAbs) are at very high risk for type 1 diabetes. We assessed whether a population with mAbs detected by screening is also at very high risk, and how risk varies according to age, type of autoantibodies and metabolic status. METHODS: Type 1 Diabetes TrialNet Pathway to Prevention participants with mAbs (n = 1815; age, 12.35 ± 9.39 years; range, 1-49 years) were analysed. Type 1 diabetes risk was assessed according to age, autoantibody type/number (insulin autoantibodies [IAA], glutamic acid decarboxylase autoantibodies [GADA], insulinoma-associated antigen-2 autoantibodies [IA-2A] or zinc transporter 8 autoantibodies [ZnT8A]) and Index60 (composite measure of fasting C-peptide, 60 min glucose and 60 min C-peptide). Cox regression and cumulative incidence curves were utilised in this cohort study. RESULTS: Age was inversely related to type 1 diabetes risk in those with mAbs (HR 0.97 [95% CI 0.96, 0.99]). Among participants with 2 autoantibodies, those with GADA had less risk (HR 0.35 [95% CI 0.22, 0.57]) and those with IA-2A had higher risk (HR 2.82 [95% CI 1.76, 4.51]) of type 1 diabetes. Those with IAA and GADA had only a 17% 5 year risk of type 1 diabetes. The risk was significantly lower for those with Index60 <1.0 (HR 0.23 [95% CI 0.19, 0.30]) vs those with Index60 values ≥1.0. Among the 12% (225/1815) ≥12.0 years of age with GADA positivity, IA-2A negativity and Index60 <1.0, the 5 year risk of type 1 diabetes was 8%. CONCLUSIONS/INTERPRETATION: Type 1 diabetes risk varies substantially according to age, autoantibody type and metabolic status in individuals screened for mAbs. An appreciable proportion of older children and adults with mAbs appear to have a low risk of progressing to type 1 diabetes at 5 years. With this knowledge, clinical trials of type 1 diabetes prevention can better target those most likely to progress.


Assuntos
Autoanticorpos/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Estado Pré-Diabético/patologia , Adolescente , Adulto , Autoanticorpos/análise , Doenças Autoimunes/sangue , Doenças Autoimunes/genética , Doenças Autoimunes/patologia , Criança , Pré-Escolar , Estudos de Coortes , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/genética , Diabetes Mellitus Tipo 1/patologia , Progressão da Doença , Feminino , Seguimentos , Predisposição Genética para Doença , Teste de Tolerância a Glucose , Humanos , Individualidade , Lactente , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estado Pré-Diabético/sangue , Estado Pré-Diabético/diagnóstico , Estado Pré-Diabético/genética , Prognóstico , Fatores de Risco , Adulto Jovem
11.
Diabetes Care ; 42(12): 2190-2196, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31548247

RESUMO

OBJECTIVE: In September 2016, the U.S. Food and Drug Administration approved the Medtronic 670G "hybrid" closed-loop system. In Auto Mode, this system automatically controls basal insulin delivery based on continuous glucose monitoring data but requires users to enter carbohydrates and blood glucose for boluses. To track real-world experience with this first commercial closed-loop device, we prospectively followed pediatric and adult patients starting the 670G system. RESEARCH DESIGN AND METHODS: This was a 1-year prospective observational study of patients with type 1 diabetes starting the 670G system between May 2017 and May 2018 in clinic. RESULTS: Of the total of 84 patients who received 670G and consented, 5 never returned for follow-up, with 79 (aged 9-61 years) providing data at 1 week and 3, 6, 9, and/or 12 months after Auto Mode initiation. For the 86% (68 out of 79) with 1-week data, 99% (67 out of 68) successfully started. By 3 months, at least 28% (22 out of 79) had stopped using Auto Mode; at 6 months, 34% (27 out of 79); at 9 months, 35% (28 out of 79); and by 12 months, 33% (26 out of 79). The primary reason for continuing Auto Mode was desire for increased time in range. Reasons for discontinuation included sensor issues in 62% (16 out of 26), problems obtaining supplies in 12% (3 out of 26), hypoglycemia fear in 12% (3 out of 26), multiple daily injection preference in 8% (2 out of 26), and sports in 8% (2 out of 26). At all visits, there was a significant correlation between hemoglobin A1c (HbA1c) and Auto Mode utilization. CONCLUSIONS: While Auto Mode utilization correlates with improved glycemic control, a focus on usability and human factors is necessary to ensure use of Auto Mode. Alarms and sensor calibration are a major patient concern, which future technology should alleviate.


Assuntos
Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Adulto , Glicemia/análise , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Estados Unidos , Adulto Jovem
12.
Diabetes ; 68(6): 1267-1276, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30967424

RESUMO

A three-arm, randomized, double-masked, placebo-controlled phase 2b trial performed by the Type 1 Diabetes TrialNet Study Group previously demonstrated that low-dose anti-thymocyte globulin (ATG) (2.5 mg/kg) preserved ß-cell function and reduced HbA1c for 1 year in new-onset type 1 diabetes. Subjects (N = 89) were randomized to 1) ATG and pegylated granulocyte colony-stimulating factor (GCSF), 2) ATG alone, or 3) placebo. Herein, we report 2-year area under the curve (AUC) C-peptide and HbA1c, prespecified secondary end points, and potential immunologic correlates. The 2-year mean mixed-meal tolerance test-stimulated AUC C-peptide, analyzed by ANCOVA adjusting for baseline C-peptide, age, and sex (n = 82) with significance defined as one-sided P < 0.025, was significantly higher in subjects treated with ATG versus placebo (P = 0.00005) but not ATG/GCSF versus placebo (P = 0.032). HbA1c was significantly reduced at 2 years in subjects treated with ATG (P = 0.011) and ATG/GCSF (P = 0.022) versus placebo. Flow cytometry analyses demonstrated reduced circulating CD4:CD8 ratio, increased regulatory T-cell:conventional CD4 T-cell ratios, and increased PD-1+CD4+ T cells following low-dose ATG and ATG/GCSF. Low-dose ATG partially preserved ß-cell function and reduced HbA1c 2 years after therapy in new-onset type 1 diabetes. Future studies should determine whether low-dose ATG might prevent or delay the onset of type 1 diabetes.


Assuntos
Soro Antilinfocitário/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Fatores Imunológicos/uso terapêutico , Adolescente , Adulto , Peptídeo C/metabolismo , Relação CD4-CD8 , Criança , Diabetes Mellitus Tipo 1/imunologia , Diabetes Mellitus Tipo 1/metabolismo , Método Duplo-Cego , Feminino , Citometria de Fluxo , Hemoglobinas Glicadas/metabolismo , Fator Estimulador de Colônias de Granulócitos/uso terapêutico , Humanos , Masculino , Linfócitos T Reguladores/imunologia , Adulto Jovem
13.
Diabetes Technol Ther ; 21(4): 170-176, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30839229

RESUMO

BACKGROUND: Infants born to mothers with diabetes commonly experience asymptomatic hypoglycemia after birth. Continuous glucose monitors (CGM) can detect asymptomatic hypoglycemia in this population without the need for painful glucose checks. METHODS: Infants born after 34 weeks of gestation to mothers with diabetes had a CGM placed after birth. One group of infants was remotely monitored in real-time by research staff during the hospitalization, whereas another group wore a blinded CGM. In both groups, hospital standard-of-care (SOC) glucose checks were performed. Clinical staff and families were blinded to CGM data. For CGM readings <45 mg/dL, research staff requested a verification blood glucose (BG) using the point-of-care glucometer. RESULTS: Sixteen infants were studied; 4 with a blinded CGM and 12 with remote monitoring (RM). When there were confirmatory hospital glucometer readings, the sensitivity of the CGM to detect hypoglycemia was 86% and the specificity was 91%. The positive predictive value was 55% and the negative predictive value was 98%. In the full cohort, hypoglycemia (<45 mg/dL) was confirmed in 12 of 16 infants with 30 events at <12 hours of life (HOL), 3 events between 12 and 24 HOL, and 1 event at >48 HOL. In the RM group, CGM detected hypoglycemia five times when the infant was not due for a BG check based on the SOC. Overall, the CGM detected five false-positive alerts and six true-positive alerts for hypoglycemia. Only one hypoglycemic episode was missed by CGM in the RM group. Barriers to recruitment included fear of pain with glucose checks, concerns with CGM use, satisfaction with the hospital SOC, personal reasons independent of the study, and lack of interest in participating in research. CONCLUSIONS: Although there were barriers to recruitment and retention in the study, we conclude that CGM can provide added benefit for detecting hypoglycemia when used early after birth.


Assuntos
Glicemia/análise , Filho de Pais com Deficiência , Diabetes Mellitus Tipo 1/sangue , Diabetes Gestacional/sangue , Hipoglicemia/diagnóstico , Monitorização Fisiológica/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemia/sangue , Recém-Nascido , Masculino , Gravidez , Adulto Jovem
14.
Diabetes Care ; 41(9): 1917-1925, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30012675

RESUMO

OBJECTIVE: A pilot study suggested that combination therapy with low-dose anti-thymocyte globulin (ATG) and pegylated granulocyte colony-stimulating factor (GCSF) preserves C-peptide in established type 1 diabetes (T1D) (duration 4 months to 2 years). We hypothesized that 1) low-dose ATG/GCSF or 2) low-dose ATG alone would slow the decline of ß-cell function in patients with new-onset T1D (duration <100 days). RESEARCH DESIGN AND METHODS: A three-arm, randomized, double-masked, placebo-controlled trial was performed by the Type 1 Diabetes TrialNet Study Group in 89 subjects: 29 subjects randomized to ATG (2.5 mg/kg intravenously) followed by pegylated GCSF (6 mg subcutaneously every 2 weeks for 6 doses), 29 to ATG alone (2.5 mg/kg), and 31 to placebo. The primary end point was mean area under the curve (AUC) C-peptide during a 2-h mixed-meal tolerance test 1 year after initiation of therapy. Significance was defined as one-sided P value < 0.025. RESULTS: The 1-year mean AUC C-peptide was significantly higher in subjects treated with ATG (0.646 nmol/L) versus placebo (0.406 nmol/L) (P = 0.0003) but not in those treated with ATG/GCSF (0.528 nmol/L) versus placebo (P = 0.031). HbA1c was significantly reduced at 1 year in subjects treated with ATG and ATG/GCSF, P = 0.002 and 0.011, respectively. CONCLUSIONS: Low-dose ATG slowed decline of C-peptide and reduced HbA1c in new-onset T1D. Addition of GCSF did not enhance C-peptide preservation afforded by low-dose ATG. Future studies should be considered to determine whether low-dose ATG alone or in combination with other agents may prevent or delay the onset of the disease.


Assuntos
Soro Antilinfocitário/administração & dosagem , Citoproteção/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/efeitos dos fármacos , Células Secretoras de Insulina/efeitos dos fármacos , Adolescente , Adulto , Soro Antilinfocitário/efeitos adversos , Peptídeo C/sangue , Criança , Diabetes Mellitus Tipo 1/fisiopatologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Fator Estimulador de Colônias de Granulócitos/administração & dosagem , Fator Estimulador de Colônias de Granulócitos/efeitos adversos , Humanos , Células Secretoras de Insulina/fisiologia , Masculino , Projetos Piloto , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/efeitos adversos , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/efeitos adversos , Adulto Jovem
16.
Pediatr Diabetes ; 19(3): 420-428, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29159870

RESUMO

OBJECTIVE: The primary objective of this trial was to evaluate the feasibility, safety, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system vs predictive low glucose suspension (PLGS) alone in optimizing overnight glucose control in children 6 to 14 years old. RESEARCH DESIGN AND METHODS: Twenty-eight participants 6 to 14 years old with T1D duration ≥1 year with daily insulin therapy ≥12 months and on insulin pump therapy for ≥6 months were randomized per night into PHHM mode or PLGS-only mode for 42 nights. The primary outcome was percentage of time in sensor-measured range 70 to 180 mg/dL in the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased time in target range (70-180 mg/dL) from 66 ± 11% during PLGS nights to 76 ± 9% during PHHM nights (P<.001), without increasing hypoglycemia as measured by time below various thresholds. Average morning blood glucose improved from 176 ± 28 mg/dL following PLGS nights to 154 ± 19 mg/dL following PHHM nights (P<.001). CONCLUSIONS: The PHHM system was effective in optimizing overnight glycemic control, significantly increasing time in range, lowering mean glucose, and decreasing glycemic variability compared to PLGS alone in children 6 to 14 years old.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina , Monitorização Ambulatorial/instrumentação , Adolescente , Glicemia , Criança , Alarmes Clínicos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Estudos de Viabilidade , Feminino , Humanos , Masculino
18.
Diabetes Care ; 40(11): 1494-1499, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28860125

RESUMO

OBJECTIVE: We assessed dysglycemia and a T1D Diagnostic Index60 (Index60) ≥1.00 (on the basis of fasting C-peptide, 60-min glucose, and 60-min C-peptide levels) as prediagnostic end points for type 1 diabetes among Type 1 Diabetes TrialNet Pathway to Prevention Study participants. RESEARCH DESIGN AND METHODS: Two cohorts were analyzed: 1) baseline normoglycemic oral glucose tolerance tests (OGTTs) with an incident dysglycemic OGTT and 2) baseline Index60 <1.00 OGTTs with an incident Index60 ≥1.00 OGTT. Incident dysglycemic OGTTs were divided into those with (DYS/IND+) and without (DYS/IND-) concomitant Index60 ≥1.00. Incident Index60 ≥1.00 OGTTs were divided into those with (IND/DYS+) and without (IND/DYS-) concomitant dysglycemia. RESULTS: The cumulative incidence for type 1 diabetes was greater after IND/DYS- than after DYS/IND- (P < 0.01). Within the normoglycemic cohort, the cumulative incidence of type 1 diabetes was higher after DYS/IND+ than after DYS/IND- (P < 0.001), whereas within the Index60 <1.00 cohort, the cumulative incidence after IND/DYS+ and after IND/DYS- did not differ significantly. Among nonprogressors, type 1 diabetes risk at the last OGTT was greater for IND/DYS- than for DYS/IND- (P < 0.001). Hazard ratios (HRs) of DYS/IND- with age and 30- to 0-min C-peptide were positive (P < 0.001 for both), whereas HRs of type 1 diabetes with these variables were inverse (P < 0.001 for both). In contrast, HRs of IND/DYS- and type 1 diabetes with age and 30- to 0-min C-peptide were consistent (all inverse [P < 0.01 for all]). CONCLUSIONS: The findings suggest that incident dysglycemia without Index60 ≥1.00 is a suboptimal prediagnostic end point for type 1 diabetes. Measures that include both glucose and C-peptide levels, such as Index60 ≥1.00, appear better suited as prediagnostic end points.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Adolescente , Adulto , Peptídeo C/sangue , Criança , Pré-Escolar , Estudos de Coortes , Determinação de Ponto Final , Seguimentos , Teste de Tolerância a Glucose , Humanos , Lactente , Pessoa de Meia-Idade , Adulto Jovem
19.
Diabetes Care ; 40(3): 359-366, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28100606

RESUMO

OBJECTIVE: The objective of this study was to determine the safety, feasibility, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system compared with predictive low-glucose insulin suspension (PLGS) alone in overnight glucose control. RESEARCH DESIGN AND METHODS: A 42-night trial was conducted in 30 individuals with type 1 diabetes in the age range 15-45 years. Participants were randomly assigned each night to either PHHM or PLGS and were blinded to the assignment. The system suspended the insulin pump on both the PHHM and PLGS nights for predicted hypoglycemia but delivered correction boluses for predicted hyperglycemia on PHHM nights only. The primary outcome was the percentage of time spent in a sensor glucose range of 70-180 mg/dL during the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased the time spent in the target range (70-180 mg/dL) from 71 ± 10% during PLGS nights to 78 ± 10% during PHHM nights (P < 0.001). The average morning blood glucose concentration improved from 163 ± 23 mg/dL after PLGS nights to 142 ± 18 mg/dL after PHHM nights (P < 0.001). Various sensor-measured hypoglycemic outcomes were similar on PLGS and PHHM nights. All participants completed 42 nights with no episodes of severe hypoglycemia, diabetic ketoacidosis, or other study- or device-related adverse events. CONCLUSIONS: The addition of a predictive hyperglycemia minimization component to our existing PLGS system was shown to be safe, feasible, and effective in overnight glucose control.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hiperglicemia/tratamento farmacológico , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Adulto , Glicemia/metabolismo , Automonitorização da Glicemia , Método Duplo-Cego , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Adulto Jovem
20.
Lancet ; 389(10067): 369-380, 2017 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-28007348

RESUMO

BACKGROUND: The safety and effectiveness of a continuous, day-and-night automated glycaemic control system using insulin and glucagon has not been shown in a free-living, home-use setting. We aimed to assess whether bihormonal bionic pancreas initialised only with body mass can safely reduce mean glycaemia and hypoglycaemia in adults with type 1 diabetes who were living at home and participating in their normal daily routines without restrictions on diet or physical activity. METHODS: We did a random-order crossover study in volunteers at least 18 years old who had type 1 diabetes and lived within a 30 min drive of four sites in the USA. Participants were randomly assigned (1:1) in blocks of two using sequentially numbered sealed envelopes to glycaemic regulation with a bihormonal bionic pancreas or usual care (conventional or sensor-augmented insulin pump therapy) first, followed by the opposite intervention. Both study periods were 11 days in length, during which time participants continued all normal activities, including athletics and driving. The bionic pancreas was initialised with only the participant's body mass. Autonomously adaptive dosing algorithms used data from a continuous glucose monitor to control subcutaneous delivery of insulin and glucagon. The coprimary outcomes were the mean glucose concentration and time with continuous glucose monitoring (CGM) glucose concentration less than 3·3 mmol/L, analysed over days 2-11 in participants who completed both periods of the study. This trial is registered with ClinicalTrials.gov, number NCT02092220. FINDINGS: We randomly assigned 43 participants between May 6, 2014, and July 3, 2015, 39 of whom completed the study: 20 who were assigned to bionic pancreas first and 19 who were assigned to the comparator first. The mean CGM glucose concentration was 7·8 mmol/L (SD 0·6) in the bionic pancreas period versus 9·0 mmol/L (1·6) in the comparator period (difference 1·1 mmol/L, 95% CI 0·7-1·6; p<0·0001), and the mean time with CGM glucose concentration less than 3·3 mmol/L was 0·6% (0·6) in the bionic pancreas period versus 1·9% (1·7) in the comparator period (difference 1·3%, 95% CI 0·8-1·8; p<0·0001). The mean nausea score on the Visual Analogue Scale (score 0-10) was greater during the bionic pancreas period (0·52 [SD 0·83]) than in the comparator period (0·05 [0·17]; difference 0·47, 95% CI 0·21-0·73; p=0·0024). Body mass and laboratory parameters did not differ between periods. There were no serious or unexpected adverse events in the bionic pancreas period of the study. INTERPRETATION: Relative to conventional and sensor-augmented insulin pump therapy, the bihormonal bionic pancreas, initialised only with participant weight, was able to achieve superior glycaemic regulation without the need for carbohydrate counting. Larger and longer studies are needed to establish the long-term benefits and risks of automated glycaemic management with a bihormonal bionic pancreas. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases of the National Institutes of Health, and National Center for Advancing Translational Sciences.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/administração & dosagem , Hormônios/administração & dosagem , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Biônica , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Glucagon/uso terapêutico , Hormônios/uso terapêutico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Náusea/induzido quimicamente , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA