Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-34822327

RESUMO

Low-intensity pulsed ultrasound (LIPUS) accelerates fracture healing by stimulating the production of bone callus and the mineralization process. This study compared a novel bimodal acoustic signal (BMAS) device for bone fracture healing to a clinical LIPUS system (EXOGEN; Bioventus, Durham, NC, USA). Thirty rabbits underwent a bilateral fibular osteotomy. Each rabbits' legs were randomized to receive 20-min treatment daily for 18 days with BMAS or LIPUS. The latter utilizes a longitudinal ultrasonic mode only, while the former employs ultrasound-induced shear stress to promote bone formation. Power Doppler imaging (PDI) was acquired days 0, 2, 4, 7, 11, 14, and 18 post-surgery to monitor treatment response and quantified off-line. X-rays were acquired to evaluate fractures on days 0, 14, 18, and 21. Seventeen rabbits completed the study and were euthanized day 21 post-surgery. The fibulae were analyzed to determine maximum torque, initial torsional stiffness, and angular displacement at failure. ANOVAs and paired t-tests were used to compare pair-wise outcome variables for the two treatment modes on a per rabbit basis. The BMAS system induced better fracture healing with greater stiffness (BMAS 0.21 ± 0.19 versus LIPUS 0.16 ± 0.19 [Formula: see text]cm/°, p = 0.050 ) and maximum torque (BMAS 7.84 ± 5.55 versus LIPUS 6.26 ± 3.46 [Formula: see text]cm, p = 0.022 ) than the LIPUS system. Quantitative PDI assessments showed a higher amount of vascularity with LIPUS than BMAS on days 4 and 18 ( ). In conclusion, the novel BMAS technique achieved better bone fracture healing response than the current Food and Drug Administration (FDA)-approved LIPUS system.


Assuntos
Consolidação da Fratura , Terapia por Ultrassom , Acústica , Animais , Calo Ósseo , Coelhos , Terapia por Ultrassom/métodos , Ondas Ultrassônicas
2.
Artigo em Inglês | MEDLINE | ID: mdl-19251524

RESUMO

This paper presents the fabrication and characterization of single-element ultrasonic transducers whose active elements are made of lead-free piezoceramic, 1-3 PZT/polymer composite and PVDF film. The lead free piezoelectric KNNLT- LS(K(0.44)Na(0.52)Li(0.04))(Nb(0.84)Ta(0.10)S(0.06)b)O(3) powders and ceramics were prepared under controlled humidity and oxygen flow rate during sintering. Due to its moderate longitudinal piezoelectric charge coefficient (175 pC/N) and k(t) of 0.50, the KNN-LT-LS composition may be a good candidate for high frequency transducer applications. PZT fibers with 25 microm diameter formed by the viscose suspension spinning process were incorporated into epoxy to fabricate 1-3 composites with the averaged k(t) = 0.64 and d(33) = 400 pC/N. Using KNN-LS-LT ceramic, 1-3 PZT fiber composite, and PVDF film, 3 different unfocused single element transducers with center frequencies of 25 MHz were fabricated. The acoustic characterization of the transducers demonstrated that wideband and low insertion loss could be obtained employing KNN-LS-LT ceramic. The -6 dB bandwidth and insertion loss were 70% and -21 dB, respectively. In comparison, the insertion loss of the ceramic transducer was much smaller than those made with 1-3 composite and PVDF film. This was attributed to closer electrical impedance match to 50 ohm and higher thickness coupling coefficient of the ceramic transducer.


Assuntos
Chumbo/química , Polivinil/química , Titânio/química , Transdutores , Ultrassonografia/instrumentação , Zircônio/química , Acústica , Algoritmos , Fenômenos Químicos , Impedância Elétrica
3.
Ultrasonics ; 43(2): 79-85, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15530981

RESUMO

Nonlinear contrast imaging modes such as second harmonic imaging (HI) and subharmonic imaging (SHI) are increasingly important for clinical applications. However, the performance of currently available transducers for HI and SHI is significantly constrained by their limited bandwidth. To bypass this constraint, a novel transducer concept termed multi-frequency harmonic transducer arrays (MFHA's) has been designed and a preliminary evaluation has been conducted. The MFHA may ultimately be used for broadband contrast enhanced HI and SHI with high dynamic range and consists of three multi-element piezo-composite sub-arrays (A-C) constructed so the center frequencies are 4f(A) = 2f(B) = f(C) (specifically 2.5/5.0/10.0 MHz and 1.75/3.5/7.0 MHz). In principle this enables SHI by transmitting on sub-array C receiving on B and, similarly, from B to A as well as HI by transmitting on A receiving on B and, likewise, from B to C. Initially transmit and receive pressure levels of the arrays were measured with the elements of each sub-array wired in parallel. Following contrast administration, preliminary in vitro HI and SHI signal-to-noise ratios of up to 40 dB were obtained. In conclusion, initial design and in vitro characterization of two MFHA's have been performed. They have an overall broad frequency bandwidth of at least two octaves. Due to the special design of the array assembly, the SNR for HI and SHI was comparable to that of regular B-mode and better than commercially available HI systems. However, further research on multi-element MFHA's is required before their potential for in vivo nonlinear contrast imaging can be assessed.


Assuntos
Ultrassonografia Doppler/métodos , Acústica , Meios de Contraste , Capacitância Elétrica , Transdutores
4.
J Ultrasound Med ; 22(2): 145-53, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12562119

RESUMO

OBJECTIVE: To study the use of power Doppler sonography for assessing changes in vascularity during treatment of fracture sites with low-intensity ultrasound. METHODS: In 6 dogs (3 pairs), subcutaneous dissection of the midshaft of the ulna allowed symmetrical osteotomies to be made with a reciprocation saw. Three dogs were treated and 3 were used as controls. The fracture site was subjected to 1.5-MHz low-intensity ultrasound (30 mW/cm2) for 20 minutes daily from a therapeutic ultrasonic device. Gray scale sonography was performed to evaluate the fracture site. Power Doppler sonography was used to assess flow patterns at the fracture site and surrounding soft tissue. A sonographic contrast agent was administered intravenously. The dose was 0.2 mL/kg. RESULTS: Power Doppler sonography showed an increase in flow around the fracture site in the treated dogs compared with that in control dogs. Color pixel values on day 7 were 3-fold higher in treated legs than control legs and on day 11 were 33% higher in treated legs than control legs. Enhancement after contrast agent administration was consistently higher in treated legs than control legs. CONCLUSIONS: Power Doppler sonography showed increased vascularity around the fracture sites in treated dogs with and without contrast agent administration.


Assuntos
Consolidação da Fratura , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/terapia , Ulna/irrigação sanguínea , Terapia por Ultrassom , Ultrassonografia Doppler em Cores , Animais , Cães
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA