Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Thromb Haemost ; 123(3): 336-346, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36402132

RESUMO

BACKGROUND: The ABO blood group system is linked to hemostasis via its relationship with von Willebrand factor (VWF) and factor VIII (FVIII). In the current study, we investigated the association of the ABO system with clinical outcomes as well as VWF and platelet function in patients with left ventricular assist devices (LVADs). METHODS: Bleeding and thromboembolic complications were assessed in 111 patients during 1 year after LVAD implantation. In 67 LVAD patients, VWF antigen, VWF activity, VWF ristocetin cofactor, VWF collagen-binding, and FVIII activity were assessed. Platelet surface P-selectin and activated glycoprotein IIb/IIIa were determined by flow cytometry, and soluble P-selectin was measured with an enzyme-linked immunoassay. Platelet aggregation was assessed by light transmission and impedance aggregometry. RESULTS: Thirty-six patients (32.4%) experienced a bleeding and 22 patients (19.8%) a thromboembolic event. In univariate analyses, patients with blood group O had numerically more bleeding complications and less thromboembolic events as compared to patients with blood group non-O (both p ≥ 0.05). After multivariable adjustment, blood group O was significantly associated with a higher risk of bleeding (hazard ratio 2.42 [95% confidence interval 1.03-5.70], p = 0.044) but not linked to thromboembolic complications. CONCLUSION: Patients with blood group O had significantly lower levels of VWF and FVIII (all p < 0.05), whereas P-selectin expression in response to thrombin-receptor activating peptide and soluble P-selectin were higher as compared to patients with blood group non-O (both p < 0.05). LVAD patients with blood group O are at an increased bleeding risk, potentially due to lower VWF and FVIII levels.


Assuntos
Coração Auxiliar , Hemostáticos , Tromboembolia , Doenças de von Willebrand , Humanos , Fator de von Willebrand/metabolismo , Sistema ABO de Grupos Sanguíneos , Selectina-P , Coração Auxiliar/efeitos adversos , Fator VIII/análise , Hemorragia/etiologia , Tromboembolia/complicações , Doenças de von Willebrand/complicações
2.
Front Cardiovasc Med ; 9: 888269, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548436

RESUMO

Background: Contemporary Left Ventricular Assist Devices (LVADs) mainly operate at a constant speed, only insufficiently adapting to changes in patient demand. Automatic physiological speed control promises tighter integration of the LVAD into patient physiology, increasing the level of support during activity and decreasing support when it is excessive. Methods: A sensorless modular control algorithm was developed for a centrifugal LVAD (HVAD, Medtronic plc, MN, USA). It consists of a heart rate-, a pulsatility-, a suction reaction-and a supervisor module. These modules were embedded into a safe testing environment and investigated in a single-center, blinded, crossover, clinical pilot trial (clinicaltrials.gov, NCT04786236). Patients completed a protocol consisting of orthostatic changes, Valsalva maneuver and submaximal bicycle ergometry in constant speed and physiological control mode in randomized sequence. Endpoints for the study were reduction of suction burden, adequate pump speed and flowrate adaptations of the control algorithm for each protocol item and no necessity for intervention via the hardware safety systems. Results: A total of six patients (median age 53.5, 100% male) completed 13 tests in the intermediate care unit or in an outpatient setting, without necessity for intervention during control mode operation. Physiological control reduced speed and flowrate during patient rest, in sitting by a median of -75 [Interquartile Range (IQR): -137, 65] rpm and in supine position by -130 [-150, 30] rpm, thereby reducing suction burden in scenarios prone to overpumping in most tests [0 [-10, 2] Suction events/minute] in orthostatic upwards transitions and by -2 [-6, 0] Suction events/min in Valsalva maneuver. During submaximal ergometry speed was increased by 86 [31, 193] rpm compared to constant speed for a median flow increase of 0.2 [0.1, 0.8] L/min. In 3 tests speed could not be increased above constant set speed due to recurring suction and in 3 tests speed could be increased by up to 500 rpm with a pump flowrate increase of up to 0.9 L/min. Conclusion: In this pilot study, safety, short-term efficacy, and physiological responsiveness of a sensorless automated speed control system for a centrifugal LVAD was established. Long term studies are needed to show improved clinical outcomes. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT04786236.

3.
Pharmaceuticals (Basel) ; 15(4)2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35455481

RESUMO

Growth differentiation factor (GDF)-15 inhibits platelet activation, prevents thrombus formation, and has been linked to bleeding events. This was a prospective study including 51 left-ventricular assist device (LVAD) patients on aspirin and phenprocoumon. Platelet surface expression of activated glycoprotein (GP) IIb/IIIa was assessed by flow cytometry, and platelet aggregation was measured by multiple electrode aggregometry (MEA) in response to arachidonic acid (AA), adenosine diphosphate (ADP), and thrombin receptor-activating peptide (TRAP), a protease-activated-receptor-1 (PAR-1) agonist. GDF-15 was determined with a commercially-available assay. There was a trend towards an inverse correlation of GDF-15 with activated GPIIb/IIIa in response to TRAP (r = -0.275, p = 0.0532) but not in response to AA and ADP. Moreover, GDF-15 correlated with MEA TRAP (r = -0.326, p = 0.0194), whereas it did not correlate with MEA ADP and MEA AA. In a second step, GDF-15 levels in the fourth quartile were defined as high GDF-15. Patients with high GDF-15 showed significantly lower TRAP-inducible platelet aggregation by MEA compared to patients in the first quartile (63 AU vs. 113 AU, p = 0.0065). In conclusion, in LVAD patients receiving state-of-the-art antithrombotic therapy, GDF-15 correlates inversely with residual platelet reactivity via PAR-1.

4.
Life (Basel) ; 12(3)2022 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-35330210

RESUMO

Right heart failure (RHF) is a severe complication after left ventricular assist device (LVAD) implantation. The aim of this study was to analyze the incidence, risk factors, and biomarkers for late RHF including the possible superiority of the device and implantation method. This retrospective, single-center study included patients who underwent LVAD implantation between 2014 and 2018. Primary outcome was freedom from RHF over one-year after LVAD implantation; secondary outcomes included pre- and postoperative risk factors and biomarkers for RHF. Of the 145 consecutive patients (HeartMate 3/HVAD: n = 70/75; female: 13.8%), thirty-one patients (21.4%) suffered RHF after a mean LVAD support of median (IQR) 105 (118) days. LVAD implantation method (less invasive: 46.7% vs. 35.1%, p = 0.29) did not differ significantly in patients with or without RHF, whereas the incidence of RHF was lower in HeartMate 3 vs. HVAD patients (12.9% vs. 29.3%, p = 0.016). Multivariate Cox proportional hazard analysis identified HVAD (HR 4.61, 95% CI 1.12-18.98; p = 0.03), early post-op heart rate (HR 0.96, 95% CI 0.93-0.99; p = 0.02), and central venous pressure (CVP) (HR 1.21, 95% CI 1.05-1.39; p = 0.01) as independent risk factors for RHF, but no association of RHF with increased all-cause mortality (HR 1.00, 95% CI 0.99-1.01; p = 0.50) was found. To conclude, HVAD use, lower heart rate, and higher CVP early post-op were independent risk factors for RHF following LVAD implantation.

5.
Artif Organs ; 46(6): 1149-1157, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34978722

RESUMO

BACKGROUND: A relation between the left ventricular assist device inflow cannula (IC) malposition and pump thrombus has been reported. This study aimed to investigate if the pump position, derived from chest X-rays in HeartMate 3 (HM3) patients, correlates with neurological dysfunction (ND), ischemic stroke (IS), hemorrhagic stroke (HS) and survival. METHODS: This analysis was performed on routinely acquired X-rays of 42 patients implanted with a HM3 between 2014 and 2017. Device position was quantified in patients with and without ND from frontal and lateral X-rays characterizing the IC and pump in relation to spine, diaphragm or horizontal line. The primary end-point was freedom from stroke and survival one-year after HM3 implantation stratified by pump position. RESULTS: The analysis of X-rays, 33.5 (41.0) days postoperative, revealed a significant smaller IC angle of HM3 patients with ND versus no ND (0.1° ± 14.0° vs. 12.9° ± 10.1°, p = 0.005). Additionally, the IC angle in the frontal view, IS: 4.1 (20.9)° versus no IS: 13.8 (7.5)°, p = 0.004 was significantly smaller for HM3 patients with IS. Using receiver operating characteristics derived cut-off, IC angle <10° provided 75% sensitivity and 100% specificity (C-statistic = 0.85) for predicting IS. Stratified by IC angle, freedom from IS at 12 months was 100% (>10°) and 60% (<10°) respectively (p = 0.002). No significant differences were found in any end-point between patients with and without HS. One-year survival was significantly higher in patients with IC angle >10° versus <10° (100% vs. 71.8%, p = 0.012). CONCLUSIONS: IC malposition derived from standard chest X-rays serves as a risk factor for ND, IS and worse survival in HM3 patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Cânula/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/complicações , Trombose/etiologia
6.
Platelets ; 33(2): 249-256, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33760697

RESUMO

Left-ventricular assist devices (LVADs) improve outcomes in end-stage heart failure patients. Two centrifugal-flow LVAD systems are currently approved, HeartMate 3 (HM3) and Medtronic/Heartware HVAD (HVAD). Clinical findings suggest differences in thrombogenicity between both systems. We compared markers of platelet activation and aggregation between HM3 and HVAD. We prospectively included 59 LVAD patients (40 HM3, 19 HVAD). Platelet P-selectin expression, activated glycoprotein (GP) IIb/IIIa and monocyte-platelet aggregates (MPA) were assessed by flow-cytometry. Platelet aggregation was measured by light-transmission aggregometry (LTA) and multiple-electrode aggregometry (MEA). Von-Willebrand factor (VWF) antigen (VWF:Ag), VWF activity (VWF:Ac), and VWF multimer pattern analysis were determined. Soluble P-selectin (sP-selectin) was measured with an enzyme-linked immunoassay. P-selectin, GPIIb/IIIa and MPA levels in vivo and in response to arachidonic acid, adenosine diphosphate, and thrombin receptor activating peptide were similar between HM3 and HVAD (all p > .05). Likewise, agonist-inducible platelet aggregation by LTA and MEA did not differ between HM3 and HVAD (all p > .05). VWF:Ag levels and FVIII:C were similar between both systems (both p > .05), but patients with HVAD had significantly lower VWF:Ac (p = .011) and reduced large VWF multimers (p = .013). Finally, sP-selectin levels were similar in patients with HVAD and HM3 (p = .845). In conclusion, on-treatment platelet activation and aggregation are similar in HM3 and HVAD patients. Potential clinical implications of observed differences in VWF profiles between both LVAD systems need to be addressed in future clinical trials.


Assuntos
Coração Auxiliar/normas , Ativação Plaquetária/fisiologia , Agregação Plaquetária/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Life (Basel) ; 11(9)2021 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-34575071

RESUMO

Several risk scores and classifications are available to predict peri- and post-operative mortality of patients with end stage heart failure receiving Left Ventricular Assist Device (LVAD) therapy. Sarcopenia has been suggested as a sensitive predictor for post-operative mortality. We evaluated whether the psoas muscle area can predict mortality in patients undergoing LVAD implantation. The indexed psoas mean area (PMAi) was obtained by measuring the psoas muscle area at the superior endplate of the third lumbar vertebra correlated to body surface area of 106 adult patients undergoing LVAD implantation (Medtronic HVAD n = 41, Abbott HeartMate II n = 4, Abbott HeartMate 3 n = 61; mean age 65, IQR 12, 90.6% male; INTERMACS Level 1 24.5%; ischemic CMP 64.2%). Patients were divided in two groups: high/moderate and low muscle mass. The primary endpoint was 30-day mortality, assessed using a multivariate Cox proportional hazards model. Baseline characteristics did not differ between patients with high or moderate and low PMAi. Estimated survival calculated a significant higher 30-day mortality in patients with low PMAi (p = 0.04). Multivariable Cox proportional hazards regression analysis indicated low PMAi, history of previous cardiac surgery and levels of bilirubin as independent predictors of mortality in the first 30 days. In conclusion, indexed psoas muscle area predicts mortality after LVAD implantation and can be used as an additional tool for risk stratification.

8.
ASAIO J ; 67(2): 157-162, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32501824

RESUMO

Anticoagulation therapy in patients using left ventricular assist device (LVAD) is essential to reduce hemocompatibility related adverse events (HRAEs). Vitamin K-antagonist dosage must be adapted and monitored by INR point-of-care testing (POCT) in outpatients. The study aims to determine if the frequency of INR POCT in LVAD outpatients has an influence on the quality of anticoagulation therapy (ACQ), HRAEs, and outcomes. This retrospective study included n = 48 patients who received LVAD implantation (HMII, HM3, and HVAD) between 2013 and 2017. ACQ (% of INR tests in range, PTR), outcomes and HRAEs using Kaplan-Meier curves were compared in a daily (n = 36) and 3×/week (n = 12) INR POCT group. Further, based on the achieved PTR ranging from 0-60% (poor), 61-70% (acceptable), and 71-100% (well controlled), HRAEs and outcomes were compared. Daily and 3×/week groups were similar in perioperative risk factors and INR target (p = 0.28). Freedom from any HRAE (38.9% vs. 25.0%, p = 0.44), any readmission (72.2% vs. 75.0%, p = 0.97), and 1 year survival (91.7% vs. 91.7%, p = 0.98) were comparable in both groups. The PTR was significantly higher with the daily self-assessments (73.5% vs. 68.4%, p = 0.006). Well vs. poorly controlled INR POCT patients more often had (p = 0.01) a daily POCT frequency (92%) vs. poorly controlled (54%) and significantly higher freedom from neurologic events (96.0 vs. 69.2%, p = 0.024) as well as hemorrhagic strokes (100% vs. 76.9%, p = 0.011). Well-controlled anticoagulation of LVAD outpatients is associated with less neurologic events. The frequency of INR POCT could be one of the key factors in the reduction of HRAEs, so future prospective, large-scale studies should help to clarify the effects.


Assuntos
Anticoagulantes/uso terapêutico , Coração Auxiliar/efeitos adversos , Coeficiente Internacional Normatizado/métodos , Testes Imediatos , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso , Feminino , Insuficiência Cardíaca/terapia , Hemorragia/sangue , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/sangue , Trombose/etiologia , Trombose/prevenção & controle
9.
ASAIO J ; 67(1): 47-52, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32404616

RESUMO

Despite increasing popularity and multiple postulated benefits, less invasive (LIS) left ventricular assist device (LVAD) implantation has not been sufficiently compared with standard full sternotomy (FS). We report the outcomes of a propensity score analysis designed to compare LIS and FS LVAD implantation, with perioperative blood product use, adverse event rates, and mortality as primary objective. From September 2010 to August 2016, 159 consecutive patients received a Medtronic HVAD or Abbott HeartMate 3 LVAD via a FS or LIS approach. Outcomes were analyzed using proportional hazard Cox regression, with risk adjustment based on a LIS approach propensity score model computed from demographics, risk factors, and operative covariates. Seventy-five patients were matched and compared (HVAD 83% [n = 62]; LIS approach 43% [n = 32]; mean age 60 ± 12 years; 89% [n = 67] male; 48% [n = 36] ischemic cardiomyopathy [ICMP]; 37% [n = 28]). Patient groups were comparable with regard to preoperative patient characteristics. Less invasive LVAD implantation was successful in all patients with no intraoperative conversions. In-hospital mortality was 16% in both groups, despite 37% Interagency Registry for Mechanically Assisted Circulatory Support Level I patients. Overall, 28% of the LIS patients did not receive any blood products intraoperatively, whereas, in the FS group, only two patients (5%) did not require the administration of blood products (p = 0.000). This was also a significant finding in the overall perioperative phase in which seven LIS patients (22%) who not receive any blood products versus two FS patients (5%; p = 0.033). Otherwise, outcomes were comparable. Less invasive LVAD implantation is a feasible, safe, and reduces blood product use.


Assuntos
Coração Auxiliar , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Implantação de Prótese/métodos , Idoso , Transfusão de Sangue/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Esternotomia
10.
ESC Heart Fail ; 7(3): 915-919, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32144947

RESUMO

Tricuspid regurgitation in patients with left ventricular assist device (LVAD) has a significant impact on prognosis and quality of life, and its effects on liver and renal function could negatively impact planned heart transplantation. The aim of the present case is to report the feasibility and the clinical impact of tricuspid transcatheter edge-to-edge repair in LVAD patients as adjunctive bridge to transplantation strategy. A 59-year-old female patient previously treated with LVAD implantation (HeartMate III) and tricuspid valve repair with 32 mm rigid ring (Medtronic Contour 3D) as bridge to transplantation developed recurrence of significant tricuspid regurgitation with right ventricular decompensation needing inotropic support. Preoperative echo showed torrential tricuspid valve regurgitation Effective regurgitant orifice area(EROA 1.4 cm2 ) with suspicious of partial detachment of the prosthetic ring. The patient was successfully treated with transcatheter edge-to-edge repair with the MitraClip XTR device. Tricuspid regurgitation was reduced by 50% (postoperative EROA 0.7 cm2 ). She remained stable under continuous inotropic support with no other episodes of right ventricular decompensation and was successfully transplanted 30 days after the clipping procedure. Transcatheter treatment of tricuspid regurgitation in a patient with LVAD was an effective strategy to gain time and bridge the patient to heart transplantation.


Assuntos
Coração Auxiliar , Insuficiência da Valva Tricúspide , Feminino , Humanos , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
11.
Artigo em Inglês | MEDLINE | ID: mdl-32191405

RESUMO

The Berlin Heart EXCOR® is a mechanical, pulsatile ventricular assist device. The paracorporeal assist device is pneumatically driven and can be used for long-term bridging therapy of one or both ventricles (LVAD, BIVAD, RVAD). It is specifically designed for pediatric patients and can be used in neonates as well as juveniles and adults.  The infant presented in this video tutorial was diagnosed with myocarditis leading to end-stage heart failure and severe mitral valve regurgitation. A bridging therapy was indicated and a Berlin Heart EXCOR® VAD was implanted. This tutorial provides detailed insight on how to perform this procedure. In addition, a safe and effective way of extending the outflow cannula is demonstrated.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Implantação de Prótese/métodos , Insuficiência Cardíaca/fisiopatologia , Humanos , Lactente
12.
Cell Physiol Biochem ; 48(4): 1638-1651, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30077999

RESUMO

BACKGROUND/AIMS: Clinical studies have reported a better outcome of smokers after myocardial infarction compared to non-smokers. The data are controversial, as some clinical studies did not observe this effect. The cell biological processes involved, which might account for a 'Smoker's Paradox', have not been investigated yet. Therefore, the aim was to elucidate the effect of cigarette smoke on the viability of cardiomyocytes in the context of hypoxia and reperfusion. METHODS: HL-1 cells were incubated with different concentrations of cigarette smoke extract (CSE) and subjected to hypoxia/reperfusion to further evaluate influence of CSE on viability of HL-1 cells using flow cytometry analyses, Western Blot and immunofluorescence staining. RESULTS: Incubation with CSE led to a concentration-dependent reduction in HL-1 viability. Adding hypoxia as a stressor enhanced cell death. Caspase-independent apoptosis was the observed type of cell death partly induced by P53 and apoptosis-inducing-factor. Yet a significant increase in LDH release in cardiomyocytes incubated with 4%, 8% and 16% CSE suggests necrosis with rapid DNA depletion. Interestingly, after hypoxia a decreased LDH release under lower CSE concentrations was observed. Moreover, a concentration-dependent increase in proliferation and a trend for increased ATP availability under hypoxic conditions was shown. CONCLUSIONS: The trend for less LDH release in hypoxia after low-level CSE incubation might represent a switch from necrosis to apoptosis, which in combination with the increase in metabolic activity and ATP availability might account for the 'Smoker's Paradox'. These findings could partly explain inconsistent results of previous clinical studies as the data showed strong evidence for the crucial relevance of the amount of cigarettes smoked. We are in need of future studies distinguishing between different types of smokers to finally verify or falsify the 'Smoker's Paradox'.


Assuntos
Apoptose , Fumaça/efeitos adversos , Animais , Hipóxia Celular , Linhagem Celular , Dano ao DNA , L-Lactato Desidrogenase/metabolismo , Camundongos , Microscopia Eletrônica de Varredura , Mitocôndrias/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Proteína Serina-Treonina Quinases de Interação com Receptores/metabolismo , Proteína Supressora de Tumor p53/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA