Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Stud Health Technol Inform ; 316: 354-355, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39176748

RESUMO

The growing number of genes identified in relation to epilepsy represents a major breakthrough in diagnosis and treatment, but experts face the challenge of efficiently accessing and consolidating the vast amount of genetic data available. Therefore, we present the process of transforming data from different sources and formats into an Entity-Attribute-Value (EAV) model database. Combined with the use of standard coding systems, this approach will provide a scalable and adaptable database to present the data in a comprehensive way to experts via a dashboard.


Assuntos
Epilepsia , Epilepsia/genética , Epilepsia/diagnóstico , Epilepsia/tratamento farmacológico , Humanos , Bases de Dados Genéticas
2.
J Neurol ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38954033

RESUMO

BACKGROUND: Clinical trials have shown that cenobamate (CNB) is an efficacious and safe anti-seizure medication (ASM) for drug-resistant focal epilepsy. Here, we analyzed one of the largest real-world cohorts, covering the entire spectrum of epilepsy syndromes, the efficacy and safety of CNB, and resulting changes in concomitant ASMs. METHODS: We conducted a retrospective observational study investigating CNB usage in two German tertiary referral centers between October 2020 and June 2023 with follow-up data up to 27 months of treatment. Our primary outcome was treatment response. Secondary outcomes comprised drug response after 12 and 18 months, seizure freedom rates, CNB dosage and retention, adverse drug reactions (ADRs), and changes in concomitant ASMs. RESULTS: 116 patients received CNB for at least two weeks. At 6 months, 98 patients were eligible for evaluation. Thereof 50% (49/98) were responders with no relevant change at 12 and 18 months. Seizure freedom was achieved in 18.4% (18/98) at 6 months, 16.7% (11/66), and 3.0% (1/33) at 12 and 18 months. The number of previous ASMs did not affect the seizure response rate. Overall, CNB was well-tolerated, however, in 7.7% (9/116), ADRs led to treatment discontinuation. The most frequent changes of concomitant ASMs included the discontinuation or reduction of sodium channel inhibitors, clobazam reduction, and perampanel discontinuation, while brivaracetam doses were usually left unchanged. CONCLUSIONS: CNB proved to be a highly effective and generally well-tolerated ASM in patients with severe drug-resistant epilepsy, comprising a broad array of epilepsy syndromes beyond focal epilepsy.

3.
Physiol Meas ; 45(6)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38772401

RESUMO

Objective. This paper aims to investigate the possibility of detecting tonic-clonic seizures (TCSs) with behind-the-ear, two-channel wearable electroencephalography (EEG), and to evaluate its added value to non-EEG modalities in TCS detection.Methods. We included 27 participants with a total of 44 TCSs from the European multicenter study SeizeIT2. The wearable Sensor Dot (Byteflies) was used to measure behind-the-ear EEG, electromyography (EMG), electrocardiography, accelerometry (ACC) and gyroscope. We evaluated automatic unimodal detection of TCSs, using sensitivity, precision, false positive rate (FPR) and F1-score. Subsequently, we fused the different modalities and again assessed performance. Algorithm-labeled segments were then provided to two experts, who annotated true positive TCSs, and discarded false positives.Results. Wearable EEG outperformed the other single modalities with a sensitivity of 100% and a FPR of 10.3/24 h. The combination of wearable EEG and EMG proved most clinically useful, delivering a sensitivity of 97.7%, an FPR of 0.4/24 h, a precision of 43%, and an F1-score of 59.7%. The highest overall performance was achieved through the fusion of wearable EEG, EMG, and ACC, yielding a sensitivity of 90.9%, an FPR of 0.1/24 h, a precision of 75.5%, and an F1-score of 82.5%.Conclusions. In TCS detection with a wearable device, combining EEG with EMG, ACC or both resulted in a remarkable reduction of FPR, while retaining a high sensitivity.Significance. Adding wearable EEG could further improve TCS detection, relative to extracerebral-based systems.


Assuntos
Acelerometria , Eletroencefalografia , Eletromiografia , Convulsões , Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Eletromiografia/instrumentação , Acelerometria/instrumentação , Convulsões/diagnóstico , Convulsões/fisiopatologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem
4.
Epilepsia ; 65(4): 974-983, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38289522

RESUMO

OBJECTIVE: Electroencephalography (EEG) microstate analysis seeks to cluster the scalp's electric field into semistable topographical EEG activity maps at different time points. Our study aimed to investigate the features of EEG microstates in subjects with focal epilepsy and psychogenic nonepileptic seizures (PNES). METHODS: We included 62 adult subjects with focal epilepsy or PNES who received video-EEG monitoring at the epilepsy monitoring unit. The subjects (mean age = 42.8 ± 21.2 years) were distributed equally between epilepsy and PNES groups. We extracted microstates from a 4.4 ± 1.0-min, 21-channel resting-state EEG. We excluded subjects with interictal epileptiform discharges during resting-state EEGs. After preprocessing, we derived five main EEG microstates-MS1 to MS5-for the full frequency band (1-30 Hz) and frequency subbands (delta, 1-4 Hz; theta, 4-8 Hz; alpha, 8-12 Hz; beta, 12-30 Hz), using the MATLAB-based EEGLAB toolkit. Statistical features of microstates (duration, occurrence, contribution, global field power [GFP]) were compared between the groups, using logistic regression corrected for age and sex. RESULTS: We detected no differences in microstate parameters in the full frequency band. We found a longer duration (delta: B = -7.680, p = .046; theta: B = -16.200, p = .043) and a higher contribution (delta: B = -7.414, p = .035; theta: B = -7.509, p = .031) of MS4 in lower frequency bands in the epilepsy group. The PNES group showed a higher occurrence of MS5 in the delta subband (B = 3.283, p = .032). In the theta subband, a higher GFP of MS1 was associated with the PNES group (B = 5.674, p = .025), whereas a higher GFP of MS2 was associated with the epilepsy group (B = -6.579, p = .026). SIGNIFICANCE: Microstate features show differences between patients with focal epilepsy and PNES. EEG microstates could be a promising parameter, helping to understand changes in brain dynamics in subjects with epilepsy, and should be explored as a potential biomarker.


Assuntos
Epilepsias Parciais , Epilepsia , Adulto , Humanos , Adulto Jovem , Pessoa de Meia-Idade , Convulsões/epidemiologia , Convulsões Psicogênicas não Epilépticas , Epilepsia/epidemiologia , Epilepsias Parciais/diagnóstico , Eletroencefalografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA