Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36898524

RESUMO

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Desenho de Prótese
2.
Can J Cardiol ; 38(1): 102-112, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34688853

RESUMO

BACKGROUND: Staphylococcus aureus (SA) has been extensively studied as causative microorganism of surgical prosthetic-valve infective endocarditis (IE). However, scarce evidence exists on SA IE after transcatheter aortic valve replacement (TAVR). METHODS: Data were obtained from the Infectious Endocarditis After TAVR International Registry, including patients with definite IE after TAVR from 59 centres in 11 countries. Patients were divided into 2 groups according to microbiologic etiology: non-SA IE vs SA IE. RESULTS: SA IE was identified in 141 patients out of 573 (24.6%), methicillin-sensitive SA in most cases (115/141, 81.6%). Self-expanding valves were more common than balloon-expandable valves in patients presenting with early SA IE. Major bleeding and sepsis complicating TAVR, neurologic symptoms or systemic embolism at admission, and IE with cardiac device involvement (other than the TAVR prosthesis) were associated with SA IE (P < 0.05 for all). Among patients with IE after TAVR, the likelihood of SA IE increased from 19% in the absence of those risk factors to 84.6% if ≥ 3 risk factors were present. In-hospital (47.8% vs 26.9%; P < 0.001) and 2-year (71.5% vs 49.6%; P < 0.001) mortality rates were higher among patients with SA IE vs non-SA IE. Surgery at the time of index SA IE episode was associated with lower mortality at follow-up compared with medical therapy alone (adjusted hazard ratio 0.46, 95% CI 0.22-0.96; P = 0.038). CONCLUSIONS: SA IE represented approximately 25% of IE cases after TAVR and was associated with very high in-hospital and late mortality. The presence of some features determined a higher likelihood of SA IE and could help to orientate early antibiotic regimen selection. Surgery at index SA IE was associated with improved outcomes, and its role should be evaluated in future studies.


Assuntos
Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Sistema de Registros , Infecções Estafilocócicas/epidemiologia , Staphylococcus aureus/isolamento & purificação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/microbiologia , Feminino , Seguimentos , Saúde Global , Próteses Valvulares Cardíacas/microbiologia , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Taxa de Sobrevida/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos
3.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34390296

RESUMO

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
Clin. infect. dis ; 73(11): 3750-e:3758, Dec. 2021. graf, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1353336

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite , Substituição da Valva Aórtica Transcateter
5.
J Am Coll Cardiol ; 77(18): 2276-2287, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33958124

RESUMO

BACKGROUND: Stroke is one of the most common and potentially disabling complications of infective endocarditis (IE). However, scarce data exist about stroke complicating IE after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The purpose of this study was to determine the incidence, risk factors, clinical characteristics, management, and outcomes of patients with definite IE after TAVR complicated by stroke during index IE hospitalization. METHODS: Data from the Infectious Endocarditis after TAVR International Registry (including 569 patients who developed definite IE following TAVR from 59 centers in 11 countries) was analyzed. Patients were divided into two groups according to stroke occurrence during IE admission (stroke [S-IE] vs. no stroke [NS-IE]). RESULTS: A total of 57 (10%) patients had a stroke during IE hospitalization, with no differences in causative microorganism between groups. S-IE patients exhibited higher rates of acute renal failure, systemic embolization, and persistent bacteremia (p < 0.05 for all). Previous stroke before IE, residual aortic regurgitation ≥moderate after TAVR, balloon-expandable valves, IE within 30 days after TAVR, and vegetation size >8 mm were associated with a higher risk of stroke during the index IE hospitalization (p < 0.05 for all). Stroke rate in patients with no risk factors was 3.1% and increased up to 60% in the presence of >3 risk factors. S-IE patients had higher rates of in-hospital mortality (54.4% vs. 28.7%; p < 0.001) and overall mortality at 1 year (66.3% vs. 45.6%; p < 0.001). Surgical treatment was not associated with improved outcomes in S-IE patients (in-hospital mortality: 46.2% in surgical vs. 58.1% in no surgical treatment; p = 0.47). CONCLUSIONS: Stroke occurred in 1 of 10 patients with IE post-TAVR. A history of stroke, short time between TAVR and IE, vegetation size, valve prosthesis type, and residual aortic regurgitation determined an increased risk. The occurrence of stroke was associated with increased in-hospital and 1-year mortality rates, and surgical treatment failed to improve clinical outcomes.


Assuntos
Endocardite Bacteriana/complicações , Complicações Pós-Operatórias , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/terapia
6.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-33733675

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33044863
8.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1148174
9.
Artigo em Inglês | MEDLINE | ID: mdl-27578840

RESUMO

BACKGROUND: Transcatheter aortic valves can degenerate in a manner similar to surgical bioprostheses. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent redo transcatheter aortic valve replacement (TAVR) procedures >2 weeks post procedure were collected from 14 centers. Among 13 876 patients, 50 (0.4%) underwent redo TAVR procedure at participating centers. Indications for redo TAVR were moderate-severe prosthetic aortic valve stenosis (n=10, 21.7%), moderate-severe central prosthetic aortic valve regurgitation (n=13, 28.3%), and moderate-severe paraprosthetic aortic valve regurgitation (n=25, 50.0%). The index TAVR was most commonly a Medtronic CoreValve (N=38, 76.0%), followed by Edwards SAPIEN-type valves (n=12, 24.0%) and Portico (n=1, 2.0%). The redo TAVR device was most commonly a CoreValve/Evolut R (n=29, 58.0%), followed by a SAPIEN-type valve (n=20,40.0%) or a Boston Lotus valve (n=1, 2.0%). In 40 patients (80.0%), redo TAVR was performed using the identical device type or that of the succeeding generation. Valve performance was uniformly good after redo TAVR (mean transvalvular gradient post redo TAVR: 12.5±6.1 mm Hg). At hospital discharge, all patients remained alive, with 1 nondisabling stroke (2.0%) and 1 life-threatening bleed (2.0%). Permanent pacemaker implantation was required in 3 out of 35 patients without a prior pacemaker (8.6%). Late survival was 85.1% at a median follow-up of 1589 days (range: 31-3775) after index TAVR and 635 days (range: 8-2460) after redo TAVR. CONCLUSIONS: Redo TAVR for the treatment of postprocedural and late occurrence of paravalvular regurgitation and transcatheter aortic valve prosthesis failure seems to be safe, and it is associated with favorable acute and midterm clinical and echocardiographic outcomes.


Assuntos
Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Canadá , Ecocardiografia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA