1.
Laryngoscope ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39016182

RESUMO

INTRODUCTION: Osteotomies are routinely incorporated in rhinoplasty, however, the influence of mass, velocity, kinetic energy (KE), and momentum (p) of the mallet on fracture patterns has not been studied. METHODS: An experimental sledge guillotine setup was designed simulating a mallet strike with adjustable height and mass and 2 mm-thick Sawbone blocks. KE and p were calculated using KE = ½ mass × velocity2 and p = mass × velocity formulas. Fracture lengths and angles were measured. RESULTS: Ten groups with varying mallet masses and drop heights were tested with 10 bones per group. Fracture length positively correlated with KE (R = 0.542, p < 0.001) and p (R = 0.508, p < 0.001). Fracture angle also positively correlated with KE (R = 0.367, p < 0.001) and p (R = 0.329, p < 0.001). In groups with similar KE, osteotomies with higher p (heavier mallet with slower velocity) had greater fracture lengths (29.31 ± 0.68 vs. 27.68 ± 2.12 mm, p = 0.013) but similar fracture angles (p = 0.189). In groups with similar p, osteotomies with higher KE (lighter hammer with faster velocity) had significantly greater fracture lengths (28.28 ± 1.28 vs. 20.45 ± 12.20 mm, p = 0.041) and greater divergent fracture angles (3.13 ± 1.97° vs. 1.40 ± 1.36°, p = 0.031). Regression modeling of the relationship between KE and fracture lengths and angles demonstrated that cubic followed by logarithmic regression models had the best fits. CONCLUSION: Osteotomy fracture patterns positively correlated with the mallet's KE more so than its p, suggesting that the mallet's velocity has an increased impact effect than its mass. Clinically, a heavier mallet with a lower velocity will likely generate a smaller fracture length and fracture angle, indicating a more controlled and ideal fracture. LEVEL OF EVIDENCE: NA Laryngoscope, 2024.

2.
Laryngoscope ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38924582

RESUMO

INTRODUCTION: The physical modification of cartilage grafts during rhinoplasty risks chondrocyte death at the margins where the tissue is cut. This study compares chondrocyte viability between diced, scaled, and pate samples in human models, and further computes percent chondrocyte viability as a function of sequential dicing size in a computational model. METHODS: Septal cartilage from 11 individuals was prepared as follows: diced (1 mm cubic), scaled (shaved to <1 mm thickness ~ translucent), pate (0.02 g of scraped cartilage surface), positive control (2 × 2 mm diced), and negative control (2 × 2 mm diced soaked in 70% EtOH). Viability analysis was performed using Live/Dead assay™ and confocal microscopy. Numerical simulation of cartilage dicing in 0.05 mm increments was performed using MATLAB assuming 250 chondrocytes/mm3 with each average chondrocyte size of 65 µm2. RESULTS: Chondrocyte viability was similar between 1 mm diced cartilage, scaled cartilage, and positive control samples (p > 0.05). Conversely, pate samples had significantly less viability compared to positive controls, diced samples, and scaled samples (all p < 0.01 after Bonferroni correction). Pate samples had similar chondrocyte viability compared to negative controls (p = 0.36). On computational modeling, cartilage viability decreased to 50% as the diced sample was cut from 1 mm edge length to 0.7-0.8 mm. Similarly, cartilage viability decreased to 26% at 0.55-0.65 mm, 11% at 0.4-0.5 mm, and <5% at <0.4 mm edge length. CONCLUSION: Modifying septal cartilage grafts into 1 mm diced or scaled samples maintains ideal chondrocyte viability whereas pate preparations result in significant chondrocyte death. According to computational analysis, chondrocyte viability sharply decreases as the cartilage is diced below 0.7-0.8 mm. LEVEL OF EVIDENCE: N/A Laryngoscope, 2024.

3.
Exp Eye Res ; 244: 109941, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38782177

RESUMO

Refractive errors remain a global health concern, as a large proportion of the world's population is myopic. Current ablative approaches are costly, not without risks, and not all patients are candidates for these procedures. Electromechanical reshaping (EMR) has been explored as a viable cost-effective modality to directly shape tissues, including cartilage. In this study, stromal collagen structure and fibril orientation was examined before and after EMR with second-harmonic generation microscopy (SHG), a nonlinear multiphoton imaging method that has previously been used to study native corneal collagen with high spatial resolution. EMR, using a milled metal contact lens and potentiostat, was performed on the corneas of five extracted rabbit globes. SHG was performed using a confocal microscopy system and all images underwent collagen fibril orientation analysis. The collagen SHG signal in controls is uniform and is similarly seen in samples treated with pulsed potential, while continuous EMR specimens have reduced, nonhomogeneous signal. Collagen fibril orientation in native tissue demonstrates a broad distribution with suggestion of another peak evolving, while with EMR treated eyes a bimodal characteristic becomes readily evident. Pulsed EMR may be a means to correct refractive errors, as when comparing its SHG signal to negative control, preservation of collagen structures with little to no damage is observed. From collagen fiber orientation analysis, it can be inferred that simple DC application alters the structure of collagen. Future studies will involve histological assessment of these layers and multi-modal imaging analysis of dosimetry.


Assuntos
Colágeno , Microscopia Confocal , Microscopia de Geração do Segundo Harmônico , Animais , Coelhos , Microscopia de Geração do Segundo Harmônico/métodos , Colágeno/metabolismo , Substância Própria/metabolismo , Córnea
7.
Artigo em Inglês | MEDLINE | ID: mdl-38530098

RESUMO

Objectives: To evaluate trends in botulinum toxin (BTX) industry payments to physicians. Methods: Cross-sectional analysis of nonroyalty, BTX-specific payments made by Allergan (Botox), Ipsen (Dysport), and Merz (Xeomin) to physicians using the 2016-2020 Open Payments Database. Results: Between 2016 and 2020, >$27 million in payments was made for BTX-related activities to dermatologists, neurologists, ophthalmologists, otolaryngologists, and plastic surgeons, with payments ranging from $3.9 million in 2016 to $8.7 million in 2019. 21.7% was paid to dermatologists, 57.5% to neurologists, 5.9% to ophthalmologists, 5.7% to otolaryngologists, and 9.1% to plastic surgeons. Conclusions: Growing amounts are being paid to physicians for BTX-related activities-both medical and aesthetic. Despite the variety of indications for BTX within otolaryngology, otolaryngology payments were overshadowed by other specialties, which may reflect greater BTX utilization in those specialties.

8.
Int J Pediatr Otorhinolaryngol ; 178: 111900, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38408413

RESUMO

OBJECTIVE: Drug induced sleep endoscopy (DISE) is often performed for pediatric obstructive sleep apnea (OSA) when initial diagnostic studies do not provide adequate information for therapy. However, DISE scoring is subjective and with limitations. This proof-of-concept study demonstrates the use of a novel long-range optical coherence tomography (LR-OCT) system during DISE of two pediatric patients. METHODS: LR-OCT was used to visualize the airway of pediatric patients during DISE. At the conclusion of DISE, the OCT probe was guided in the airway under endoscopic visual guidance, and cross-sectional images were acquired at the four VOTE locations. Data processing involved image resizing and alignment, followed by rendering of three-dimensional (3D) volumetric models of the airways. RESULTS: Two patients were included in this study. Patient one had 18.4%, 20.9%, 72.3%, and 97.3% maximal obstruction at velum, oropharynx, tongue base, and epiglottis, while patient two had 40.2%, 41.4%, 8.0%, and 17.5% maximal obstruction at these regions, respectively. Three-dimensional reconstructions of patients' airways were also constructed from the OCT images. CONCLUSION: This proof-of-concept study demonstrates the successful evaluation of pediatric airway during DISE using LR-OCT, which accurately identified sites and degrees of obstruction with respective 3D airway reconstruction.


Assuntos
Obstrução das Vias Respiratórias , Apneia Obstrutiva do Sono , Humanos , Criança , Tomografia de Coerência Óptica , Polissonografia , Endoscopia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Sono , Obstrução das Vias Respiratórias/diagnóstico por imagem , Obstrução das Vias Respiratórias/etiologia
9.
Facial Plast Surg Aesthet Med ; 26(4): 371-376, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38377584

RESUMO

Background: Many open-access artificial intelligence (AI)-based websites that rate facial attractiveness are available, but none have been compared with human focus group outcomes. Objective: To compare human and AI-based websites scoring of facial attractiveness of adult female white faces. Methods: A 40-photograph database of AI-generated adult, white, female, expressionless, and frontal-view facial images were scored by otolaryngology residents and five AI-based facial rating websites: prettyscale.com, attractivenesstest.com, face-score.com/en, hotchat3000.com, and beautyscoretest.com. Sample t-test and bivariate correlation were performed for statistical analyses. Results: The focus group of 24 otolaryngology residents consisted of 62.5% males and 58.3% white participants. There was a strong positive correlation between average human score and average AI score for each photo (Pearson's correlation 0.84, p < 0.01). The average human raters' scores were significantly lower than the average AI scores (5.0 ± 1.8 vs. 6.9 ± 0.9, p < 0.01). Thirty images (75.0%) had statistically higher scores from the AI websites versus the focus group. On correlation analysis, all AI-based websites individually had scores that positively correlate with the human scores (all p < 0.05). Conclusion: AI-based websites and human focus-group scoring of facial attractiveness of adult white female faces were significantly correlated with the AI ratings biased toward higher values, encouraging their cautious utilization in future research.


Assuntos
Inteligência Artificial , Beleza , Face , Grupos Focais , Humanos , Feminino , Masculino , Adulto , Face/anatomia & histologia , Fotografação , Internet
11.
Facial Plast Surg Aesthet Med ; 26(4): 469-474, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38215259

RESUMO

Background: A "boomerang" graft is an end-to-end caudal septal extension graft (SEG) that conforms to the geometry of the anterior septal angle, and avoids septal overlap, unlike a side-to-side SEG. Objective: To compare breathing improvements in rhinoplasty patients receiving boomerang SEGs and patients receiving side-to-side SEGs. Methods: Retrospective cohort analysis of patients undergoing rhinoplasty with either end-to-end boomerang SEG or a side-to-side SEG. Functional outcomes were assessed through the Nasal Obstruction Symptom Evaluation (NOSE) survey. Results: The boomerang SEG cohort had a mean age of 34 years and were 68% female compared with 38 years and 67% female in the side-to-side SEG cohort (p > 0.05). The cohorts did not differ in the proportion of the lateral crural tensioning, spreader graft placement, or history of rhinoplasty. The boomerang cohort demonstrated a 67% reduction in NOSE scores compared with a 70% reduction among the side-to-side SEG cohort (p = 0.14). Men undergoing boomerang graft placement reported significantly less postoperative functional improvement than men undergoing placement of a side-to-side SEG (62% vs. 77%, p = 0.01). Conclusion: Use of a boomerang graft is not likely to negatively affect rhinoplasty functional outcomes when compared with a side-to-side SEG.


Assuntos
Obstrução Nasal , Septo Nasal , Rinoplastia , Humanos , Rinoplastia/métodos , Masculino , Feminino , Estudos Retrospectivos , Adulto , Septo Nasal/cirurgia , Obstrução Nasal/cirurgia , Resultado do Tratamento , Cartilagens Nasais/cirurgia , Cartilagens Nasais/transplante , Respiração , Pessoa de Meia-Idade
12.
Facial Plast Surg ; 40(1): 120-126, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36509105

RESUMO

This study aims to identify the epidemiology and effects of facial fractures on return to play (RTP) in Major League Soccer (MLS) and the English Premier League (EPL). A total of 39 MLS players and 40 EPL players who sustained facial fractures from 2007 to 2019 were identified. Data on player demographics, the injury, and the impact of their injury on RTP were collected. Elbow-to-head was the most common mechanism of injury (20.3%). The most common fracture involved the nasal bone (48.3%). Most players (90%) RTP the same season. Players who sustained nasal fractures missed significantly fewer games (p < 0.001) than those who suffered other craniofacial fractures. Players treated surgically missed significantly more games (3.21 vs. 0.71, p = 0.006) and days (30.1 vs. 8.70, p = 0.002) than those managed nonoperatively. Significantly more EPL players who sustained facial fractures wore headgear upon RTP compared to MLS players (82% vs. 56%, p <0 .01). Most professional soccer players who sustain a facial fracture RTP the same season, but their recovery time can vary depending on the type of fracture, injury management, or injury severity. Our findings can help inform future craniofacial injury management as well as guidelines on player safety and fracture prevention.


Assuntos
Fraturas Cranianas , Futebol , Humanos , Futebol/lesões , Fraturas Cranianas/epidemiologia
13.
Otolaryngol Head Neck Surg ; 170(2): 605-609, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37746939

RESUMO

With the widespread adoption of intranasal radiofrequency (RF) devices, our objective was to report national adverse events (AEs) associated with their use. The Food and Drug Administration's Manufacturer and User Facility Device Experience was queried. A total of 24 device-related AEs were reported, 11 (45.8%) for Celon® (Olympus), 3 (12.5%) for Vivaer® (Aerin), 2 (8.3%) for Neuromark® (Neurent), and 8 (33.3%) for Rhinaer® (Aerin). Seven (63.6%) of the Celon®-related complications were related to tissue necrosis (largely user error-related), but 1 (9.1%) episode of pediatric ocular palsy was also reported. Vivaer® complications included synechiae formation, a mucosal perforation, and a case of empty nose syndrome. Of the posterior nasal nerve ablating devices, 9 of 10 AEs were epistaxes, of which 7 (77.8%) required operative intervention. Surgeons should exercise vigilance and tissue-appropriate device settings when utilizing RF devices. Epistaxis and tissue necrosis may occur, as well as more rare, but devastating, complications.


Assuntos
Necrose , Criança , Humanos , Bases de Dados Factuais , Estados Unidos , United States Food and Drug Administration
14.
Laryngoscope ; 134(3): 1063-1070, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37594207

RESUMO

OBJECTIVE: Nasal airway obstruction (NAO) is caused by various disorders including nasal valve collapse (NVC). A bipolar radiofrequency (RF) device (VivAer®, Aerin Medical, Sunnyvale, CA) has been used to treat NAO through RF heat generation to the upper lateral cartilage (ULC). The purpose of this study is to measure temperature elevations in nasal tissue, using infrared (IR) radiometry to map the spatial and temporal evolution of temperature. STUDY DESIGN: Experimental and computational. METHODS: Composite porcine nasal septum was harvested and sectioned (1 mm and 2 mm). The device was used to heat the cartilage in composite porcine septum. An IR camera (FLIR® ExaminIR, Teledyne, Wilsonville, OR) was used to image temperature on the back surface of the specimen. These data were incorporated into a heat transfer finite element model that also calculated tissue damage using Arrhenius rate process. RESULTS: IR temperature imaging showed peak back surface temperatures of 49.57°C and 42.21°C in 1 and 2 mm thick septums respectively. Temperature maps were generated demonstrating the temporal and spatial evolution of temperature. A finite element model generated temperature profiles with respect to time and depth. Rate process models using Arrhenius coefficients showed 30% chondrocyte death at 1 mm depth after 18 s of RF treatment. CONCLUSION: The use of this device creates a thermal profile that may result in thermal injury to cartilage. Computational modeling suggests chondrocyte death extending as deep as 1.4 mm below the treatment surface. Further studies should be performed to improve dosimetry and optimize the heating process to reduce potential injury. Laryngoscope, 134:1063-1070, 2024.


Assuntos
Obstrução Nasal , Septo Nasal , Animais , Suínos , Temperatura , Septo Nasal/cirurgia , Temperatura Corporal , Cartilagem , Condrócitos
15.
Laryngoscope ; 134(2): 651-653, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37300433

RESUMO

Handheld ultrasound devices can be used in revision rhinoplasty to evaluate the calcification of costal rib cartilage that is to be harvested for grafting. This article provides instructions on how to perform this technique. Laryngoscope, 134:651-653, 2024.


Assuntos
Cartilagem Costal , Rinoplastia , Humanos , Cartilagem Costal/transplante , Rinoplastia/métodos , Transplante Autólogo , Coleta de Tecidos e Órgãos , Reoperação/métodos , Estudos Retrospectivos
16.
Plast Reconstr Surg ; 153(2): 334e-347e, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37163479

RESUMO

BACKGROUND: Current minimally invasive fat reduction modalities use equipment that can cost thousands of U.S. dollars. Electrochemical lipolysis (ECLL), using low-cost battery and electrodes (approximately $10), creates acid/base within fat (width, approximately 3 mm), damaging adipocytes. Longitudinal effects of ECLL have not been studied. In this pilot study, the authors hypothesize that in vivo ECLL induces fat necrosis, decreases adipocyte number/viability, and forms lipid droplets. METHODS: Two female Yorkshire pigs (50 to 60 kg) received ECLL. In pig 1, 10 sites received ECLL, and 10 sites were untreated. In pig 2, 12 sites received ECLL and 12 sites were untreated. For ECLL, two electrodes were inserted into dorsal subcutaneous fat and direct current was applied for 5 minutes. Adverse effects of excessive pain, bleeding, infection, and agitation were monitored. Histology, live-dead (calcein, Hoechst, ethidium homodimer-1), and morphology (Bodipy and Hoechst) assays were performed on day 0 and postprocedure days 1, 2, 7, 14 (pig 1 and pig 2), and 28 (pig 2). Average particle area, fluorescence signal areas, and adipocytes and lipid droplet numbers were compared. RESULTS: No adverse effects occurred. Live-dead assays showed adipocyte death on the anode on days 0 to 7 and the cathode on days 1 to 2 (not significant). Bodipy showed significant adipocyte loss at all sites ( P < 0.001) and lipid droplet formation at the cathode site on day 2 ( P = 0.0046). Histology revealed fat necrosis with significant increases in average particle area at the anode and cathode sites by day 14 (+277.3% change compared with untreated, P < 0.0001; +143.4%, P < 0.0001) and day 28 (+498.6%, P < 0.0001; +354.5%, P < 0.0001). CONCLUSIONS: In vivo ECLL induces fat necrosis in pigs. Further studies are needed to evaluate volumetric fat reduction. CLINICAL RELEVANCE STATEMENT: In vivo ECLL induces adipocyte death and fat necrosis. ECLL has the potential to be utilized in body fat contouring.


Assuntos
Compostos de Boro , Necrose Gordurosa , Lipólise , Feminino , Animais , Suínos , Projetos Piloto , Adipócitos
17.
Laryngoscope ; 133(12): 3370-3377, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37306215

RESUMO

OBJECTIVE: There is little knowledge about the histological organization of facial and costal cartilages in terms of matrix structure and cell morphology. Second harmonic generation (SHG) imaging is a nonlinear imaging technique that capitalizes on signal generation from highly ordered macromolecules such as collagen fibers. The purpose of this study was to use SHG microscopy to image collagen extracellular matrix (ECM) structure, chondrocyte size, and density of these cartilages. STUDY DESIGN: Experimental. METHODS: Surgical remnants of septal, lower lateral, rib, and auricular cartilages were collected following surgery, sectioned into 0.5-1 mm thick samples and fixed to facilitate batch process imaging. A Leica TCS SP8 MP Microscope and multiphoton laser were used to image the specimens. Images were analyzed for cell size, cell density, and collagen fiber directionality patterns using ImageJ. RESULTS: SHG images of septal specimens show mesh-like structure of the ECM. There appears to be a superficial layer, characterized by flattened lacunae and middle zone, marked by circular lacunae clusters, similar to what is observed in articular cartilage. The structure of the ECM depicts a visible orientation perpendicular to the surface of the perichondrium. Cell size and density analysis through ImageJ suggests variety across cartilage types. Directionality analysis indicates that the collagen in the ECM displays preferred direction. CONCLUSION: This study establishes clear extracellular models of facial and costal cartilages. Limitations include heterogeneous cartilage thickness due to processing difficulties. Further studies include automating the cutting process to increase uniformity of tissue thickness and increasing sample size to further validate results. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:3370-3377, 2023.


Assuntos
Cartilagem Articular , Cartilagem Costal , Microscopia de Geração do Segundo Harmônico , Humanos , Cartilagem Articular/anatomia & histologia , Cartilagem Articular/metabolismo , Matriz Extracelular/metabolismo , Colágeno/metabolismo
18.
Quant Imaging Med Surg ; 13(4): 2364-2375, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37064357

RESUMO

Background: The coordination and the directional order of ciliary metachronal waves are the major factors that determine the effectiveness of mucociliary clearance (MCC). Even though metachronal waves play an essential part in immune response, clinical diagnostic tools and imaging techniques that can reliably and efficiently capture their spatial distribution and function are currently limited. Methods: We present label-free high-speed visualization of ciliary metachronal wave propagations in freshly-excised tracheal explants using a spectrally-encoded interferometric microscope over a two-dimensional (2D) plane of 0.5 mm × 0.5 mm at an acquisition rate of 50 frame-per-second. Furthermore, phase-resolved enhanced dynamic (PHRED) analysis of time-series doppler images was performed, where spatial-temporal characteristics of cilia metachronal wave motions are revealed through frequency component analysis and spatial filtering. Results: The PHRED analysis of phase-resolved Doppler (PRD) images offers a capability to distinguish the propagation direction of metachronal waves, and quantitatively assess amplitude and dominant frequency of cilia beating at each spatial location. Compared to the raw PRD images, the phase-resolved dynamic wavefront imaging (PRDWI) method showed the direction and coordination of collective cilia movement more distinctively. Conclusions: The PRDWI technique can have broad application prospects for the diagnosis of human respiratory diseases and evaluation of the curative effect of treatments and open new perspectives in biomedical sciences.

19.
ACS Biomater Sci Eng ; 9(2): 595-600, 2023 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-36634100

RESUMO

The corneal stroma consists of orthogonally stacked collagen-fibril lamellae that determine the shape of the cornea and provide most of the refractive power of the eye. We have applied electromechanical reshaping (EMR), an electrochemical platform for remodeling cartilage and other semirigid tissues, to change the curvature of the cornea as a potential procedure for nonsurgical vision correction. EMR relies on short electrochemical pulses to electrolyze water, with subsequent diffusion of protons into the extracellular matrix of collagenous tissues; protonation of immobilized anions within this matrix disrupts the ionic-bonding network, leaving the tissue transiently responsive to mechanical remodeling. Re-equilibration to physiological pH restores the ionic matrix, resulting in persistent shape change of the tissue. Using ex vivo rabbit eyes, we demonstrate here the controlled change of corneal curvature over a wide range of refractive powers with no loss of optical transparency. Optical coherence tomography (OCT), combined with second-harmonic generation (SHG) and confocal microscopy, establish that EMR enables extremely fine control of corneal contouring while maintaining the underlying macromolecular collagen structure and stromal cellular viability, positioning electrochemical vision therapy as a potentially simple and ultralow-cost modality for correcting routine refractive errors.


Assuntos
Córnea , Substância Própria , Animais , Coelhos , Substância Própria/cirurgia , Colágeno , Matriz Extracelular , Tomografia de Coerência Óptica
20.
Lasers Surg Med ; 55(1): 135-145, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36511512

RESUMO

OBJECTIVES: Traditional fat contouring is now regularly performed using numerous office- based less invasive techniques. However, some limitations of these minimally invasive techniques include high cost or limited selectivity with performing localized contouring and reduction of fat. These shortcomings may potentially be addressed by electrochemical lipolysis (ECLL), a novel approach that involves the insertion of electrodes into tissue followed by application of a direct current (DC) electrical potential. This results in the hydrolysis of tissue water creating active species that lead to fat necrosis and apoptosis. ECLL can be accomplished using a simple voltage-driven system (V-ECLL) or a potential-driven feedback cell (P-ECLL) both leading to water electrolysis and the creation of acid and base in situ. The aim of this study is to determine the long-lasting effects of targeted ECLL in a Yucatan pig model. METHODS: A 5-year-old Yucatan pig was treated with both V-ECLL and P-ECLL in the subcutaneous fat layer using 80:20 platinum:iridium needle electrodes along an 8 cm length. Dosimetry parameters included 5 V V-ECLL for 5, 10, and 20 minutes, and -1.5 V P-ECLL, -2.5 V P-ECLL, -3.5 V P-ECLL for 5 minutes. The pig was assessed for changes in fat reduction over 3 months with digital photography and ultrasound. After euthanasia, tissue sections were harvested and gross pathology and histology were examined. RESULTS: V-ECLL and P-ECLL treatments led to visible fat reduction (12.1%-27.7% and 9.4%-40.8%, respectively) and contour changes across several parameters. An increased reduction of the superficial fat layer occurred with increased dosimetry parameters with an average charge transfer of 12.5, 24.3, and 47.5 C transferred for 5 V V-ECLL for 5, 10, and 20 minutes, respectively, and 2.0, 11.5, and 24.0 C for -1.5 V P-ECLL, -2.5 V P-ECLL, -3.5 V P-ECLL for 5 minutes, respectively. These dose-dependent changes were also evidenced by digital photography, gross pathology, ultrasound imaging, and histology. CONCLUSIONS: ECLL results in selective damage and long-lasting changes to the adipose layer in vivo. These changes are dose-dependent, thus allowing for more precise contouring of target areas. P-ECLL has greater efficiency and control of total charge transfer compared to V-ECLL, suggesting that a low-voltage potentiostat treatment can result in fat apoptosis equivalent to a high-voltage DC system.