Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
J Neurol Sci ; 460: 122987, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38579412

RESUMO

Neuronal intranuclear inclusion disease, caused by a GGC repeat expansion in the 5'-untranslated region of NOTCH2NLC, is a rare neurodegenerative condition with highly variable clinical manifestations. In recent years, the number of reported cases have increased dramatically in East Asia. We report the first four genetically confirmed cases of neuronal intranuclear inclusion disease in New Zealand, all having Polynesian ancestry (three New Zealand Maori and one Cook Island Maori). Phenotypically, they resemble cases reported from recent large East Asian cohorts.


Assuntos
Corpos de Inclusão Intranuclear , Doenças Neurodegenerativas , Humanos , Nova Zelândia , Corpos de Inclusão Intranuclear/patologia , Corpos de Inclusão Intranuclear/genética , Doenças Neurodegenerativas/genética , Doenças Neurodegenerativas/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Receptor Notch2/genética
2.
Bioengineering (Basel) ; 10(7)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37508806

RESUMO

Scatter radiation from portable and pediatric X-rays could pose a risk to radiographers, nearby patients, and caretakers. We aim to evaluate the spatial scatter radiation distribution to the radiographers, nearby patients, and caretakers during common projections in portable and pediatric X-rays. We evaluated the three-dimensional scatter dose profiles of four and three commonly used portable and pediatric X-ray projections, respectively, by anthropomorphic phantoms and scatter probes. For portable X-ray, the AP abdomen had the highest scatter radiation dose recorded. Radiographer scatter radiation doses were 177 ± 8 nGy (longest cord extension) and 14 ± 0 nGy (hiding behind the portable X-ray machine). Nearby patient scatter radiation doses were 3323 ± 28 nGy (40 cm bed distance), 1785 ± 50 nGy (80 cm bed distance), and 580 ± 42 nGy (160 cm bed distance). The AP chest and abdomen had the highest scatter radiation dose in pediatric X-rays. Caretaker scatter radiation doses were 33 ± 1 nGy (50 cm height) and 659 ± 7 nGy (140 cm height). Although the estimated lens doses were all within safe levels, the use of shielding and caution on dose estimation by inverse square law is suggested to achieve the ALARA principle and dose optimization.

3.
J Hematol ; 11(5): 190-195, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36406831

RESUMO

Numerous hemoglobin (Hb) gene mutations have been identified, leading to a spectrum of phenotypes ranging from asymptomatic carrier states to complicated hemolytic anemias. We report a rare case of asymptomatic hypoxemia in a father and his teenage daughter both of whom were found to be carriers of Hb gene variant Zara. Workup for alternative cardiovascular causes of hypoxemia was unremarkable. Further sequencing of the alpha globin locus showed both individuals to be heterozygous for the Hb Zara c.274C>A (p.Leu92Ile) variant of unknown significance in the alpha2-globin gene. This is the first documented association of this Hb variant with familial asymptomatic hypoxemia, highlighting the importance of evaluating for hemoglobinopathies in patients with reduced oxygen saturation.

4.
JAMA Pediatr ; 176(7): 699-714, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35467725

RESUMO

Importance: Appropriately established pediatric reference intervals are critical to the clinical decision-making process and should reflect the physiologic changes that occur during healthy child development. Reference intervals used in pediatric care today remain highly inconsistent across a broad range of common clinical biomarkers. Observations: This narrative review assesses biomarker-specific pediatric reference intervals and their clinical utility with respect to the underlying biological changes occurring during development. Pediatric reference intervals from PubMed-indexed articles published from January 2015 to April 2021, commercial laboratory websites, study cohorts, and pediatric reference interval books were all examined. Although large numbers of pediatric reference intervals are published for some biomarkers, very few are used by clinical and commercial laboratories. The patterns, extent, and timing of biomarker changes are highly variable, particularly during developmental stages with rapid physiologic changes. However, many pediatric reference intervals do not capture these changes and thus do not accurately reflect the underlying biochemistry of development, resulting in significant inconsistencies between reference intervals. Conclusions and Relevance: There is a need to correctly describe the biochemistry of child development as well as to identify strategies to develop accurate and consistent pediatric reference intervals for improved pediatric care.


Assuntos
Família , Biomarcadores , Criança , Tomada de Decisão Clínica , Humanos , Valores de Referência
5.
Nat Commun ; 12(1): 3822, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34158488

RESUMO

For two-dimensional (2D) layered semiconductors, control over atomic defects and understanding of their electronic and optical functionality represent major challenges towards developing a mature semiconductor technology using such materials. Here, we correlate generation, optical spectroscopy, atomic resolution imaging, and ab initio theory of chalcogen vacancies in monolayer MoS2. Chalcogen vacancies are selectively generated by in-vacuo annealing, but also focused ion beam exposure. The defect generation rate, atomic imaging and the optical signatures support this claim. We discriminate the narrow linewidth photoluminescence signatures of vacancies, resulting predominantly from localized defect orbitals, from broad luminescence features in the same spectral range, resulting from adsorbates. Vacancies can be patterned with a precision below 10 nm by ion beams, show single photon emission, and open the possibility for advanced defect engineering of 2D semiconductors at the ultimate scale.

6.
J Clin Apher ; 36(1): 161-176, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33063869

RESUMO

Therapeutic plasma exchange is used to treat neurological diseases in the pediatric population. Since its first use in pediatric patients with hepatic coma in the form of manual whole blood exchange, therapeutic plasma exchange has been increasingly used to treat these disorders of the nervous system. This expansion is a result of improved techniques and apheresis instruments suitable for small children, as well as the recognition of its applicability to many diseases in the pediatric population. This review provides a historical overview of the use of therapeutic apheresis in children and highlights the most common applications for therapeutic plasma exchange to treat neurological disorders in children.


Assuntos
Doenças do Sistema Nervoso/terapia , Troca Plasmática/métodos , Criança , Encefalomielite/terapia , Síndrome de Guillain-Barré/terapia , Humanos , Síndrome Miastênica de Lambert-Eaton/terapia , Miastenia Gravis/terapia , Neuromielite Óptica/terapia , Receptores de N-Metil-D-Aspartato/imunologia , Infecções Estreptocócicas/complicações , Tireoidite Autoimune/complicações
7.
Sci Adv ; 6(38)2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32938664

RESUMO

Quantum dot-like single-photon sources in transition metal dichalcogenides (TMDs) exhibit appealing quantum optical properties but lack a well-defined atomic structure and are subject to large spectral variability. Here, we demonstrate electrically stimulated photon emission from individual atomic defects in monolayer WS2 and directly correlate the emission with the local atomic and electronic structure. Radiative transitions are locally excited by sequential inelastic electron tunneling from a metallic tip into selected discrete defect states in the WS2 bandgap. Coupling to the optical far field is mediated by tip plasmons, which transduce the excess energy into a single photon. The applied tip-sample voltage determines the transition energy. Atomically resolved emission maps of individual point defects closely resemble electronic defect orbitals, the final states of the optical transitions. Inelastic charge carrier injection into localized defect states of two-dimensional materials provides a powerful platform for electrically driven, broadly tunable, atomic-scale single-photon sources.

8.
Transfusion ; 60(11): 2714-2736, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32812222

RESUMO

BACKGROUND: Immunomodulatory strategies in heparin-induced thrombocytopenia (HIT) include the use of intravenous immune globulin (IVIG) and therapeutic plasma exchange (TPE). The optimal application of these therapies is unknown and outcomes data are limited. We investigated treatment categories and laboratory and clinical outcomes of IVIG and/or TPE in HIT with a systematic literature review. STUDY DESIGN AND METHODS: We searched MEDLINE, Embase, and Web of Science through December 2019 for studies combining controlled vocabulary and keywords related to thrombocytopenia, heparin, TPE, and IVIG. The primary outcome was treatment indication. Secondary outcomes were platelet recovery, HIT laboratory parameters, heparin re-exposure, and post-treatment course. Case-level data were analyzed by qualitative synthesis. RESULTS: After 4241 references were screened, we identified 60 studies with four main categories of IVIG and/or TPE use as follows: (a) treatment of refractory HIT (n = 35; 31%); (b) initial therapy (n = 45; 40%); (c) cardiopulmonary bypass surgery (CPB; n = 30; 27%); and (d) other (n = 2; 2%). IVIG was most commonly used for the treatment of refractory HIT while TPE was primarily used to facilitate heparin exposure during CPB. Both IVIG and TPE were equally used as initial therapy. Heparin re-exposure occurred without thrombotic event in 29 TPE-treated patients and three IVIG-treated patients. CONCLUSION: In patients with HIT, both TPE and IVIG are used for initial therapy or treatment of refractory HIT. However, TPE is more commonly used in patients undergoing CPB. Prospective studies may help clarify which treatment is indicated in HIT population subsets.


Assuntos
Heparina/efeitos adversos , Imunoglobulinas Intravenosas/uso terapêutico , Troca Plasmática , Trombocitopenia , Heparina/uso terapêutico , Humanos , Trombocitopenia/induzido quimicamente , Trombocitopenia/terapia
9.
Transfusion ; 60(7): 1424-1433, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32583456

RESUMO

INTRODUCTION: Red cell exchange (RCE) therapy is increasingly used to treat patients with acute or chronic manifestations of sickle cell disease (SCD). However, little is known regarding the most safe and effective practice parameters associated with this particular therapy. METHODS: A SCD subcommittee of members of the American Society for Apheresis (ASFA) developed a 122-question survey and administered it via email to other ASFA members. The survey inquired about clinical indications for treatment, practice patterns, and transfusion policies for RCE when used for patients with SCD. RESULTS: Ninety-nine distinct institutions completed the survey. Twenty-one (21%) were from outside of the US. Twenty-two (22%) provided chronic transfusion therapy to >10 patients, and both adult (25%) and pediatric-focused services (20%) were represented. Common acute indications for RCE included acute chest syndrome, acute ischemic stroke, and pre-surgical prophylaxis. Common chronic indications included primary stroke prophylaxis, secondary stroke prophylaxis, and recurrent acute chest syndrome. Respondents most commonly set a post-RCE treatment target of 30% for the hematocrit and hemoglobin S levels, regardless of the therapeutic indication. Units for RCE were phenotypically matched in 95% of cases. About 40% of respondents reported using isovolemic hemodilution. CONCLUSIONS: This survey solicited the current practice variations in RCE from a diverse range of practice sites. Many sites reported similar practice patterns and challenges but some variations emerged. To our knowledge, this survey represents the largest and most in-depth investigation of the use of RCE for patients with SCD, and could inform future studies in the field.


Assuntos
Anemia Falciforme/terapia , Correio Eletrônico , Transfusão de Eritrócitos , Política de Saúde , Inquéritos e Questionários , Adulto , Anemia Falciforme/epidemiologia , Criança , Humanos , Masculino
10.
Haemophilia ; 26(4): 735-740, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32420682

RESUMO

INTRODUCTION: The time-dependent nature of factor VIII (FVIII) inhibitors is well described, and the standard FVIII Bethesda assay used to measure inhibitors incorporates a 2-hour incubation. Despite case reports and reviews describing the immediate-acting nature of factor IX (FIX) inhibitors, many coagulation laboratories continue to use a traditional prolonged incubation for FIX Bethesda assays. To our knowledge, a comprehensive evaluation of the FIX Bethesda assay without incubation has not been reported. AIM: The goal of this study was to evaluate the performance of a rapid FIX Bethesda (ie no incubation) compared with the standard Bethesda assay (2-hour incubation). METHODS: The analysis used a Bethesda assay configured for either immediate testing or a 2-hour incubation. Samples from 14 haemophilia B patients with inhibitors and 9 non-human controls were tested. RESULTS: The two assays yielded similar performance overall. The average per cent difference in inhibitor titre between the rapid and standard FIX Bethesda assay was -3% (range -15% to +13%; P = .175) for patient samples and -2% (range -17% to +14%; P = .376) for controls. CONCLUSION: The rapid Bethesda assay showed good agreement with the standard Bethesda assay for determination of inhibitor levels in patients with severe haemophilia B. The rapid assay allows for faster assessment of inhibitors in patients with severe haemophilia B and has the potential to improve the ability of the coagulation laboratory to perform testing from a logistical viewpoint. Further studies involving larger numbers of patients would be important to confirm our findings.


Assuntos
Inibidores dos Fatores de Coagulação Sanguínea/análise , Testes de Coagulação Sanguínea/normas , Fator IX/antagonistas & inibidores , Hemofilia B/sangue , Animais , Coagulação Sanguínea/fisiologia , Testes de Coagulação Sanguínea/estatística & dados numéricos , Testes de Coagulação Sanguínea/tendências , Fator IX/imunologia , Fator IX/metabolismo , Cabras/sangue , Hemofilia B/diagnóstico , Humanos , Indicadores e Reagentes/química , Masculino , Camundongos/sangue , Modelos Animais , Padrões de Referência , Índice de Gravidade de Doença , Ovinos/sangue
11.
Sci Rep ; 10(1): 8596, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32451405

RESUMO

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved  dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

12.
ACS Nano ; 14(6): 6999-7007, 2020 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-32459460

RESUMO

Förster resonant energy transfer (FRET)-mediated exciton diffusion through artificial nanoscale building block assemblies could be used as an optoelectronic design element to transport energy. However, so far, nanocrystal (NC) systems supported only diffusion lengths of 30 nm, which are too small to be useful in devices. Here, we demonstrate a FRET-mediated exciton diffusion length of 200 nm with 0.5 cm2/s diffusivity through an ordered, two-dimensional assembly of cesium lead bromide perovskite nanocrystals (CsPbBr3 PNCs). Exciton diffusion was directly measured via steady-state and time-resolved photoluminescence (PL) microscopy, with physical modeling providing deeper insight into the transport process. This exceptionally efficient exciton transport is facilitated by PNCs' high PL quantum yield, large absorption cross section, and high polarizability, together with minimal energetic and geometric disorder of the assembly. This FRET-mediated exciton diffusion length matches perovskites' optical absorption depth, thus enabling the design of device architectures with improved performances and providing insight into the high conversion efficiencies of PNC-based optoelectronic devices.

14.
J Clin Apher ; 35(1): 25-32, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31705563

RESUMO

IMPORTANCE: Neuromyelitis optica/neuromyelitis optica spectrum disorder patients' response to therapeutic plasma exchange (TPE) is currently incompletely characterized. OBJECTIVE: Our study aims to understand the clinical status improvement of neuromyelitis optica/neuromyelitis optica spectrum disorder patients treated with TPE. DESIGN, SETTING, AND PARTICIPANTS: This is a multicenter retrospective study conducted between 1 January 2003 and 31 July 2017 at 13 US hospitals performing apheresis procedures. Subjects studied were diagnosed with neuromyelitis optica/neuromyelitis optica spectrum disorder who received TPE during presentation with acute disease. MAIN OUTCOMES AND MEASURES: The primary outcome was clinical status improvement in patients treated with TPE. Secondary measures were procedural and patient characteristics associated with response to treatment. RESULTS: We evaluated 114 patients from 13 institutions. There was a female predilection. The largest ethnic group affected was non-Hispanic Caucasian. The average age of diagnosis was 43.1 years. The average time to diagnosis was 3.1 years. On average, five procedures were performed during each treatment series. The most commonly performed plasma volume exchange was 1.0 to 1.25 using 5% albumin as replacement fluid. Most patients (52%) did not require an additional course of TPE and noted "mild" to "moderate" clinical status improvement. Maximal symptom improvement appeared by the fourth or fifth TPE treatment. CONCLUSION AND RELEVANCE: TPE improved the clinical status of patients. Adults responded more favorably than children. Procedural characteristics, including number of TPEs, plasma volume exchanged, and replacement fluid used, were similar between institutions. TPE was well-tolerated and had a low severe adverse event profile.


Assuntos
Neuromielite Óptica/terapia , Troca Plasmática/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autoanticorpos , Remoção de Componentes Sanguíneos , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Plasmaferese , Sistema de Registros , Estudos Retrospectivos , Estados Unidos , Adulto Jovem
15.
J Clin Apher ; 34(5): 545-554, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31116461

RESUMO

INTRODUCTION: Anti-heparin/platelet factor 4 antibody immune complexes resulting from heparin-induced thrombocytopenia (HIT) are removed by therapeutic plasma exchange (TPE). We sought to define TPE in HIT practice patterns using an international survey. METHODS: A 31-item online survey was disseminated through the American Society for Apheresis. After institutional duplicate responses were eliminated, a descriptive analysis was performed. RESULTS: The survey was completed by 94 respondents from 78 institutions in 18 countries. Twenty-nine institutions (37%) used TPE for HIT (YES cohort) and 49 (63%) did not (NO cohort). Most NO respondents (65%) cited "no requests received" as the most common reason for not using TPE. Of the 29 YES respondents, 10 (34%) gave incomplete information and were excluded from the final analysis, leaving 19 responses. Of these, 18 (95%) treated ≤10 HIT patients over a 2-year period. The most common indications were cardiovascular surgery (CS; 63%) and HIT-associated thrombosis (HT; 26%). The typical plasma volume processed was 1.0 (63% CS and 58% HT). For CS, the typical replacement fluid was plasma (42%) and for HT, it was determined on an individual basis (32%). For CS, patients were treated with a set number of TPE procedures (37%) or laboratory/clinical response (37%). For HT, the number of TPE procedures typically depended on laboratory/clinical response (42%). CONCLUSION: In a minority of responding institutions, TPE is most commonly used in HIT to prophylactically treat patients who will undergo heparin re-exposure during CS. Prospective studies are needed to more clearly define the role of TPE in HIT.


Assuntos
Troca Plasmática/métodos , Guias de Prática Clínica como Assunto , Trombocitopenia/terapia , Procedimentos Cirúrgicos Cardiovasculares/métodos , Gerenciamento Clínico , Heparina/uso terapêutico , Humanos , Pré-Medicação , Inquéritos e Questionários , Trombocitopenia/induzido quimicamente
16.
J Hematol ; 8(4): 155-159, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32300463

RESUMO

Painless bleeding in a patient presenting from the community with elevated coagulation studies rarely makes the physicians suspect superwarfarin or rodenticide poisoning. Although a significant number of superwarfarin exposure cases are diagnosed every year, we believe there appears to be delay in diagnosis and confusion in determining what is the ideal way to treat and monitor these patients during the management. This is the first thorough literature review of all the reported cases of superwarfarin poisoning which also studied the clinical presentation, management and follow-up patterns. We present a 70-year-old man who presented to the emergency room with epistaxis, melena, cola-colored urine with elevated prothrombin time (PT), activated partial thromboplastin time (aPTT) and international normalized ratio (INR). Mixing studies showed complete correction of coagulopathy indicative of factor deficiency. Additional history revealed that the patient had arguments with family member at home and made us suspect superwarfarin exposure. Qualitative brodifacoum testing was positive and was managed with fresh frozen plasma and high doses of vitamin K1 (phytomenadione) with serial monitoring of INR and clinical symptoms. Superwarfarin poisoning should be considered in the differential diagnosis of a patient who presents with above clinical and laboratory profile especially in the absence of any history of coagulopathy or anticoagulant use. We want to raise public and especially physician awareness that history taking, early diagnosis and managing in right clinical setting play a significant role in survival of these patients.

17.
J Clin Apher ; 34(1): 26-32, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30375048

RESUMO

INTRODUCTION: Performing therapeutic plasma exchange (TPE) with albumin replacement decreases coagulation factor and platelet levels. No defined guidelines exist regarding laboratory testing to assess hemostasis in patients undergoing TPE. MATERIALS AND METHODS: A survey to evaluate hemostasis testing with TPE was distributed using online survey software. One response per institution was analyzed based on a hierarchical algorithm, excluding membrane filtration users, resulting in a maximum of 120 respondents per question. Descriptive analysis was performed with results reported as the number and/or frequency (%) of respondents to each question. RESULTS: The practices represented vary by institution type, number of apheresis procedures per year, and performance of TPE on children. Prior to TPE planned with albumin replacement, many respondents obtain laboratory studies for almost all patients (54.9% outpatients and 68.7% inpatients); however, some do not routinely obtain laboratory studies (9.7% outpatients and 4.4% inpatients). Hemoglobin/hematocrit, platelet count, fibrinogen, partial thromboplastin time (aPTT), and international normalized ratio (INR) are obtained prior to all TPE by 62.5%, 53.4%, 31.0%, 18.1%, and 17.7% of respondents, respectively; however, 1.0%, 8.7%, 29.0%, 38.3%, and 35.4%, respectively, do not routinely obtain these studies. Variation was observed in laboratory threshold values for action; the most common reported were hemoglobin/hematocrit <7 g/dL or 21% (31.0%), platelet count <50 × 109 /L (24.1%), fibrinogen <100 mg/dL (65.3%), aPTT >reference range and >1.5 times reference range (tied, 28.1%), and INR >1.5 (20.7%). CONCLUSIONS: Practice variation exists in hemostasis laboratory testing and threshold values for action with TPE. Further studies are needed to determine optimal hemostasis testing strategies with TPE.


Assuntos
Hemostasia , Troca Plasmática/métodos , Algoritmos , Fatores de Coagulação Sanguínea/análise , Técnicas de Laboratório Clínico , Humanos , Troca Plasmática/efeitos adversos , Contagem de Plaquetas , Padrões de Prática Médica , Inquéritos e Questionários
18.
J Clin Apher ; 33(5): 604-610, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30207610

RESUMO

BACKGROUND: Patients undergoing therapeutic plasma exchange (TPE) may present with risks for hemorrhage or thrombosis. Use of replacement fluids devoid of coagulation factors will decrease factor levels and platelet levels. There are no established guidelines for hemostasis management in these situations. MATERIALS AND METHODS: A survey to evaluate current hemostasis management practice during TPE was conducted using online survey software. One response per institution was analyzed based on a hierarchical algorithm, excluding membrane filtration users, resulting in a maximum of 107 respondents. Descriptive analysis was performed with results reported as the number and frequency (%) of respondents to each question. RESULTS: Apheresis Medicine physicians, alone (59.4%) or jointly with the requesting provider (29.2%), choose the replacement fluid. Based on a theoretical patient case receiving five TPEs approximately every other day, the percent of respondents who would use albumin with or without normal saline was 94.7% with no history of a bleeding or clotting disorder, 1.1% with active bleeding, and 8.8% with hypofibrinogenemia (<100 mg/dL) due to recent TPE. More respondents would use albumin with or without normal saline for replacement fluid when a minor invasive procedure (49.5%) vs a major surgery (8.9%) was performed 1 day before TPE. Replacement fluid selection varied among respondents for several other clinical conditions. The most frequent use for cryoprecipitate by respondents (14.3%) was hypofibrinogenemia. CONCLUSIONS: These survey results demonstrate wide interinstitutional variation in replacement fluid selection to manage hemostasis in patients undergoing TPE. Further studies are needed to guide optimal hemostasis management with TPE.


Assuntos
Hemostasia , Troca Plasmática/efeitos adversos , Padrões de Prática Médica/estatística & dados numéricos , Afibrinogenemia/terapia , Fator VIII/uso terapêutico , Feminino , Fibrinogênio/uso terapêutico , Hemorragia/etiologia , Humanos , Masculino , Plasmaferese/métodos , Albumina Sérica/uso terapêutico , Inquéritos e Questionários , Trombose/etiologia
19.
Transfusion ; 58(11): 2564-2571, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30265742

RESUMO

BACKGROUND: Hemolysis is a reported side effect of intravenous immunoglobulin (IVIG) therapy in adults, but pediatric data are scarce. We determined the frequency of IVIG-associated hemolysis in patients with Kawasaki disease (KD) and characterized risk factors for hemolysis. We hypothesized that hemolysis is more common in children with KD than adults with other disorders, and hemolysis risk is related to IVIG dose and degree of inflammation. STUDY DESIGN AND METHODS: This was an 8-year, single-center, retrospective cohort study. A total of 419 KD patients were identified; 123 had pre- and post-treatment complete blood counts allowing for assessment of anemia. Hemolytic anemia was defined as decrease in hemoglobin after IVIG greater than 1 g/dL with immunohematologic or biochemical studies supporting hemolysis. RESULTS: 123 patients were stratified as having hemolysis (n = 18, 15%) or nonhemolysis (n = 105, 85%). Patients with hemolysis were more likely to have complete versus incomplete KD (65% vs. 39%, p = 0.04) and refractory versus nonrefractory course (78% vs. 16%, p < 0.001). Patients receiving 4 g/kg versus 2 g/kg IVIG were more likely to hemolyze (89% vs. 34%, p < 0.001). Patients with hemolysis had mostly non-O blood group (94%), positive direct antiglobulin tests (89%), and positive eluates (72%). Two-thirds of patients with hemolysis required RBC transfusion. CONCLUSIONS: Hemolysis occurred in 15% of KD patients evaluated for anemia and is strongly associated with high-dose (4 g/kg) IVIG. KD patients receiving high-dose IVIG should have close hematologic monitoring to identify hemolysis.


Assuntos
Anemia Hemolítica/etiologia , Imunoglobulinas Intravenosas/efeitos adversos , Imunoglobulinas Intravenosas/uso terapêutico , Síndrome de Linfonodos Mucocutâneos/tratamento farmacológico , Pré-Escolar , Feminino , Hemólise , Humanos , Masculino , Síndrome de Linfonodos Mucocutâneos/fisiopatologia , Estudos Retrospectivos
20.
Lab Med ; 49(4): 372-376, 2018 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-29897485

RESUMO

Current chemistry analyzers measure ion concentration using ion- selective electrodes; however, may differ in the specific technology at the bedside versus the central laboratory. Instruments utilized for point-of-care testing (POCT) at the bedside use direct ion-selective electrodes, whereas central-laboratory analyzers use indirect ion-selective electrodes. Under most circumstances, these instruments will deliver the same result; however, various substances can cause interferences in one or the other. An 18-year-old Hispanic woman with a history of immune thrombocytopenic purpura (ITP) presented at Children's National Medical Center (CNMC) with a severe headache and required intravenous immunoglobulin (IVIG) therapy. Because a discrepancy developed between her point-of-care and central-laboratory sodium values, another instrument was used to retest the central-laboratory plasma specimens. The results were more in agreement with those from the point-of-care instrument and revealed a unique interference in sodium measurement related to IVIG use.


Assuntos
Imunoglobulinas Intravenosas/uso terapêutico , Púrpura Trombocitopênica Idiopática/sangue , Púrpura Trombocitopênica Idiopática/tratamento farmacológico , Sódio/sangue , Adolescente , Erros de Diagnóstico , Feminino , Humanos , Púrpura Trombocitopênica Idiopática/diagnóstico , Púrpura Trombocitopênica Idiopática/fisiopatologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA