Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 225
Filtrar
1.
Eur Heart J Digit Health ; 5(3): 344-355, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774381

RESUMO

Aims: This proof-of-concept study sought to evaluate changes in heart rate (HR) obtained from a consumer wearable device and compare against implantable loop recorder (ILR)-detected recurrence of atrial fibrillation (AF) and atrial tachycardia (AT) after AF ablation. Methods and results: REMOTE-AF (NCT05037136) was a prospectively designed sub-study of the CASA-AF randomized controlled trial (NCT04280042). Participants without a permanent pacemaker had an ILR implanted at their index ablation procedure for longstanding persistent AF. Heart rate and step count were continuously monitored using photoplethysmography (PPG) from a commercially available wrist-worn wearable. Photoplethysmography-recorded HR data were pre-processed with noise filtration and episodes at 1-min interval over 30 min of HR elevations (Z-score = 2) were compared with corresponding ILR data. Thirty-five patients were enrolled, with mean age 70.3 ± 6.8 years and median follow-up 10 months (interquartile range 8-12 months). Implantable loop recorder analysis revealed 17 out of 35 patients (49%) had recurrence of AF/AT. Compared with ILR recurrence, wearable-derived elevations in HR ≥ 110 beats per minute had a sensitivity of 95.3%, specificity 54.1%, positive predictive value (PPV) 15.8%, negative predictive value (NPV) 99.2%, and overall accuracy 57.4%. With PPG-recorded HR elevation spikes (non-exercise related), the sensitivity was 87.5%, specificity 62.2%, PPV 39.2%, NPV 92.3%, and overall accuracy 64.0% in the entire patient cohort. In the AF/AT recurrence only group, sensitivity was 87.6%, specificity 68.3%, PPV 53.6%, NPV 93.0%, and overall accuracy 75.0%. Conclusion: Consumer wearable devices have the potential to contribute to arrhythmia detection after AF ablation. Study Registration: ClinicalTrials.gov Identifier: NCT05037136 https://clinicaltrials.gov/ct2/show/NCT05037136.

3.
Heart Rhythm ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38763376

RESUMO

BACKGROUND: Long-term clinical outcomes of catheter ablation (CA) compared to thoracoscopic surgical ablation (SA) to treat patients with long-standing persistent atrial fibrillation (LSPAF) are not known. OBJECTIVES: To compare long-term (36-months) clinical efficacy, quality of life and cost-effectiveness of SA and CA in LSPAF. METHODS: Participants were followed up for 3 years using implantable loop recorder (ILR) and questionnaires to assess change in quality of life. Intention-to-treat analyses were used to report the findings. RESULTS: Of 115 LSPAF patients treated, 104 (90.4%) completed 36-months follow-up (CA=57, SA=47). Following a single procedure without anti-arrhythmic drugs (AAD) 7 (12%) patients in the CA arm and 5 (11%) in the SA arm (HR 1.22, 95% CI 0.81 to 1.83, p = 0.41) were free from AF/AT ≥30 sec at 36 months. Thirty-three patients (58%) in the CA arm and 26 (55%) in the SA arm (HR 1.04, 95% CI 0.57 to 1.88, p = 0.91) had their AF/AT burden reduced by ≥75%. The overall impact on health-related quality of life was similar, with mean QALY estimates of 2.45 (95% CI 2.31 to 2.59) for CA and 2.32 (2.13 to 2.52) for SA. Estimated costs were higher for SA (mean £24,682, 95% CI £21,746 to £27,618) than for CA (mean £18,002, 95% CI £15,422 to £20,581). CONCLUSION: In symptomatic LSPAF, CA and SA were equally effective at achieving arrhythmia outcomes (freedom from AF/AT ≥30s and ≥75% burden reduction) following a single-procedure without AADs. However, SA is significantly more costly than catheter ablation.

4.
Heart Rhythm ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38354872

RESUMO

BACKGROUND: Machine learning (ML) models have been proposed to predict risk related to transvenous lead extraction (TLE). OBJECTIVE: The purpose of this study was to test whether integrating imaging data into an existing ML model increases its ability to predict major adverse events (MAEs; procedure-related major complications and procedure-related deaths) and lengthy procedures (≥100 minutes). METHODS: We hypothesized certain features-(1) lead angulation, (2) coil percentage inside the superior vena cava (SVC), and (3) number of overlapping leads in the SVC-detected from a pre-TLE plain anteroposterior chest radiograph (CXR) would improve prediction of MAE and long procedural times. A deep-learning convolutional neural network was developed to automatically detect these CXR features. RESULTS: A total of 1050 cases were included, with 24 MAEs (2.3%) . The neural network was able to detect (1) heart border with 100% accuracy; (2) coils with 98% accuracy; and (3) acute angle in the right ventricle and SVC with 91% and 70% accuracy, respectively. The following features significantly improved MAE prediction: (1) ≥50% coil within the SVC; (2) ≥2 overlapping leads in the SVC; and (3) acute lead angulation. Balanced accuracy (0.74-0.87), sensitivity (68%-83%), specificity (72%-91%), and area under the curve (AUC) (0.767-0.962) all improved with imaging biomarkers. Prediction of lengthy procedures also improved: balanced accuracy (0.76-0.86), sensitivity (75%-85%), specificity (63%-87%), and AUC (0.684-0.913). CONCLUSION: Risk prediction tools integrating imaging biomarkers significantly increases the ability of ML models to predict risk of MAE and long procedural time related to TLE.

5.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38030358

RESUMO

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Trombose , Humanos , Feminino , Incidência , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Acidente Vascular Cerebral/etiologia
6.
Heart Rhythm ; 20(12): 1606-1614, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37633429

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and can be challenging to manage. Atrioventricular nodal (AVN) ablation may be an effective management strategy for AF in these patients. OBJECTIVE: The purpose of this study was to assess the efficacy of AVN ablation in HCM patients who have failed medical therapy and/or catheter ablation for AF. METHODS: A multicenter study with retrospective analysis of a prospectively collated HCM registry was performed. AVN ablation patients were identified. Baseline characteristics and device and procedural indications were collected. Symptoms defined by New York Heart Association and European Heart Rhythm Association classification and echocardiographic findings during follow-up were assessed. RESULTS: Fifty-nine patients were included in the study. Indications for AVN ablation were 6 (10.2%) inappropriate implantable cardioverter-defibrillator shock, 35 (59.3%) ineffective rate control, and 18 (30.5%) to regularize rhythm for symptom improvement. During post-AVN ablation follow-up of 79.4 ± 61.1 months, left ventricular ejection fraction (LVEF) remained stable (pre-LVEF 48.9% ± 12.6% vs post-LVEF 50.1% ± 10.1%; P = .29), even in those without a cardiac resynchronization therapy (CRT) device (pre-LVEF 54.3% ± 8.0% vs post-LVEF 53.8% ± 8.0%; P = .65). Forty-nine patients (83.1%) reported an improvement in symptoms regardless of AF type (17/21 [81.0%] paroxysmal vs 32/38 [84.2%] persistent; P = 1.00), presence of baseline left ventricular impairment (22/26 [84.6%] LVEF ≤50% vs 27/33 [81.8%] LVEF ≥50%; P = 1.00) or CRT device (27/32 [84.4%] CRT vs 22/27 [81.5%] no CRT; P = 1.00). Symptoms improved in 16 patients (89.0%) who underwent AVN ablation to regularize rhythm. CONCLUSION: AVN ablation improved symptoms without impacting left ventricular function in the majority of patients. The data suggest that AVN ablation is an effective and safe management approach for AF in HCM and should be further evaluated in larger prospective studies.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/terapia , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
7.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37523771

RESUMO

BACKGROUND: Leadless pacemakers (LPs) may mitigate the risk of lead failure and pocket infection related to conventional transvenous pacemakers. Atrial LPs are currently being investigated. However, the optimal and safest implant site is not known. OBJECTIVES: We aimed to evaluate the right atrial (RA) anatomy and the adjacent structures using complementary analytic models [gross anatomy, cardiac magnetic resonance imaging (MRI), and computer simulation], to identify the optimal safest location to implant an atrial LP human. METHODS AND RESULTS: Wall thickness and anatomic relationships of the RA were studied in 45 formalin-preserved human hearts. In vivo RA anatomy was assessed in 100 cardiac MRI scans. Finally, 3D collision modelling was undertaken assessing for mechanical device interaction. Three potential locations for an atrial LP were identified; the right atrial appendage (RAA) base, apex, and RA lateral wall. The RAA base had a wall thickness of 2.7 ± 1.6 mm, with a low incidence of collision in virtual implants. The anteromedial recess of the RAA apex had a wall thickness of only 1.3 ± 0.4 mm and minimal interaction in the collision modelling. The RA lateral wall thickness was 2.6 ± 0.9 mm but is in close proximity to the phrenic nerve and sinoatrial artery. CONCLUSIONS: Based on anatomical review and 3D modelling, the best compromise for an atrial LP implantation may be the RAA base (low incidence of collision, relatively thick myocardial tissue, and without proximity to relevant epicardial structures); the anteromedial recess of the RAA apex and lateral wall are alternate sites. The mid-RAA, RA/superior vena cava junction, and septum appear to be sub-optimal fixation locations.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Veia Cava Superior , Simulação por Computador , Lipopolissacarídeos , Estimulação Cardíaca Artificial/métodos , Átrios do Coração
8.
Circ Cardiovasc Imaging ; 16(6): e015352, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37288553

RESUMO

BACKGROUND: Left atrial (LA) function following catheter or surgical ablation of de-novo long-standing persistent atrial fibrillation (AF) and its impact on AF recurrence was studied in patients participating in the CASA-AF trial (Catheter Ablation vs. Thoracoscopic Surgical Ablation in Long Standing Persistent Atrial Fibrillation). METHODS: All patients underwent echocardiography preablation, 3 and 12 months post-ablation. LA structure and function were assessed by 2-dimensional volume and speckle tracking strain measurements of LA reservoir, conduit, and contractile strain. Left ventricular diastolic function was measured using transmitral Doppler filling velocities and myocardial tissue Doppler velocities to derive the e', E/e', and E/A ratios. Continuous rhythm monitoring was achieved using an implantable loop recorder. RESULTS: Eighty-three patients had echocardiographic data suitable for analysis. Their mean age was 63.6±9.7 years, 73.5% were male, had AF for 22.8±11.6 months, and had a mean LA maximum volume of 48.8±13.8 mL/m2. Thirty patients maintained sinus rhythm, and 53 developed AF recurrence. Ablation led to similar reductions in LA volumes at follow-up in both rhythm groups. However, higher LA emptying fraction (36.3±10.6% versus 27.9±9.9%; P<0.001), reservoir strain (22.6±8.5% versus 16.7±5.7%; P=0.001), and contractile strain (9.2±3.4% versus 5.6±2.5%; P<0.001) were noted in the sinus rhythm compared with AF recurrence group following ablation at 3 months. Diastolic function was better in the sinus rhythm compared with the AF recurrence group with an E/A ratio of 1.5±0.5 versus 2.2±1.2 (P<0.001) and left ventricular E/e' ratio of 8.0±2.1 versus 10.3±4.1 (P<0.001), respectively. LA contractile strain at 3 months was the only independent predictor of AF recurrence. CONCLUSIONS: Following ablation for long-standing persistent AF, improvement in LA function was greater in those who maintained sinus rhythm. LA contractile strain at 3 months was the most important determinant of AF recurrence following ablation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02755688.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/métodos , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Recidiva , Resultado do Tratamento
9.
Clin Microbiol Infect ; 29(10): 1335.e1-1335.e7, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37330139

RESUMO

OBJECTIVES: We evaluated the field diagnostic accuracy of a syphilis rapid test (RDT), using serum and whole blood by non-laboratorians in two Canadian Arctic communities. METHODS: We implemented a multisite prospective field evaluation wherein patients were screened by an RDT containing treponemal and non-treponemal components (Chembio DPP® Syphilis Screen & Confirm) between January 2020 and December 2021. Venous whole blood and serum were collected for rapid testing and compared with laboratory-based serology reference testing using a reverse sequence algorithm of treponemal and rapid plasma reagin (RPR) testing. RESULTS: Overall, 135 whole blood and 139 serum specimens were collected from 161 participants during clinical encounters. Treponemal-RDT sensitivity against a treponemal-reference standard (38/161 confirmed cases) was similar for serum (78% [95% CI: 61-90%]) and whole blood (81% [95% CI: 63-93%]). In those with RPR titres ≥1:8 (i.e. suggestive of recent/active infection), sensitivity increased to 93% (95% CI: 77-99%) for serum and 92% (95% CI: 73-99%) for whole blood. Treponemal-RDT specificity was excellent (99% [95% CI: 95-100%]) for both specimen types. Non-treponemal-RDT sensitivity against RPR was 94% (95% CI: 80-99%) for serum and 79% (95% CI: 60-92%) for whole blood. Sensitivity increased to 100% (95% CI: 88-100%) for serum and 92% (95% CI: 73-99%) for whole blood when RPR titres ≥1:8. RDT performance with whole blood was similar to that with serum. DISCUSSION: Non-laboratorians using the RDT accurately identified individuals with infectious syphilis under real-world conditions in an intended-use setting at the point of care. Implementing the RDT can eliminate treatment delays and may enhance disease control.


Assuntos
Sífilis , Humanos , Testes de Diagnóstico Rápido , Sensibilidade e Especificidade , Canadá , Sorodiagnóstico da Sífilis , Treponema pallidum
10.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37072340

RESUMO

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Retratamento , Antiarrítmicos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
11.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786511

RESUMO

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Hemodinâmica/fisiologia , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Função Ventricular Esquerda/fisiologia , Estimulação Cardíaca Artificial
12.
JACC Clin Electrophysiol ; 9(3): 385-393, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36752449

RESUMO

BACKGROUND: Dyssynchrony-associated left ventricular systolic dysfunction is a major contributor to heart failure in congenital heart disease (CHD). Although conventional cardiac resynchronization therapy (CRT) has shown benefit, the comparative efficacy of cardiac conduction system pacing (CSP) is unknown. OBJECTIVES: The purpose of this study was compare the clinical outcomes of CSP vs conventional CRT in CHD with biventricular, systemic left ventricular anatomy. METHODS: Retrospective CSP data from 7 centers were compared with propensity score-matched conventional CRT control subjects. Outcomes were lead performance, change in left ventricular ejection fraction (LVEF), and QRS duration at 12 months. RESULTS: A total of 65 CSP cases were identified (mean age 37 ± 21 years, 46% men). The most common CHDs were tetralogy of Fallot (n = 12 [19%]) and ventricular septal defect (n = 12 [19%]). CSP was achieved after a mean of 2.5 ± 1.6 attempts per procedure (38 patients with left bundle branch pacing, 17 with HBP, 10 with left ventricular septal myocardial). Left bundle branch area pacing [LBBAP] vs HBP was associated with a smaller increase in pacing threshold (Δ pacing threshold 0.2 V vs 0.8 V; P = 0.05) and similar sensing parameters at follow-up. For 25 CSP cases and control subjects with baseline left ventricular systolic dysfunction, improvement in LVEF was non-inferior (Δ LVEF 9.0% vs 6.0%; P = 0.30; 95% confidence limits: -2.9% to 10.0%) and narrowing of QRS duration was more pronounced for CSP (Δ QRS duration 35 ms vs 14 ms; P = 0.04). Complications were similar (3 [12%] CSP, 4 [16%] conventional CRT; P = 1.00). CONCLUSIONS: CSP can be reliably achieved in biventricular, systemic left ventricular CHD patients with similar improvement in LVEF and greater QRS narrowing for CSP vs conventional CRT at 1 year. Among CSP patients, pacing electrical parameters were superior for LBBAP vs HBP.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Disfunção Ventricular Esquerda , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Terapia de Ressincronização Cardíaca/efeitos adversos , Bloqueio de Ramo , Fascículo Atrioventricular , Volume Sistólico , Estudos Retrospectivos , Eletrocardiografia , Função Ventricular Esquerda , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia , Disfunção Ventricular Esquerda/terapia
13.
Eur Heart J Case Rep ; 7(1): ytac474, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36685101

RESUMO

Background: Leadless pacemakers present a viable alternative to conventional transvenous devices to mitigate the risk of lead- and/or pocket-related complications. In elderly patients who have encountered ventricular lead failures with transvenous pacemakers, this option may enable the delivery of atrioventricular synchronous pacing therapy, while obviating the requirement for lead extraction and lead-based pacemaker re-implantation. Case summary: This case report describes the successful implantation of a leadless pacemaker in a 90-year-old who had undergone two dual-chamber permanent pacemaker implantation procedures with a failure of three of four previously implanted leads. Atrioventricular synchronous pacing was achieved, as the leadless device was able to track the atrial-paced rhythm from the pre-existing right-sided device. Discussion: In elderly patients who have encountered issues with transvenous pacemakers, alternative approaches should be considered to mitigate the risk of future complications. Leadless pacemakers may offer a low-risk solution, enabling the delivery of atrioventricular synchronous pacing therapy in such patient groups. Future studies should be designed to delineate whether these devices could be utilized as a first-line approach in certain situations.

14.
Int J Cardiol Heart Vasc ; 44: 101171, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36660200

RESUMO

Introduction: Conduction system pacing (CSP), consisting of His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) is a rapidly developing field. These pacing techniques result in single lead left ventricular resynchronisation. Understanding of the associated learning curve of the two techniques is an important consideration for new implanters/implanting centres. Methods: We conducted a review of the first 30 cases of both HBP and LBBAP at The Royal Brompton Hospital. The procedural duration and fluoroscopy time were used as surrogates for the learning curve of each technique. Results: Patient characteristics were similar in HBP and LBBAP groups; LV ejection fraction (46% vs 54%, p = 0.08), pre-procedural QRS duration (119 ms vs 128 ms, p = 0.32).Mean procedural duration was shorter for LBBAP than for HBP (87 vs 107mins, p = 0.04) and the drop in procedural duration was more marked in LBBAP, plateauing and remaining low at 80mins after the initial 10 cases. Fluoroscopic screening time mirrored procedural duration (8 min vs 16 min, p < 0.01). Discussion/Conclusion: Our data suggest that the CSP learning curve was shorter for LBBAP than for HBP and appears to plateaux after the first 10 cases, however the HBP learning curve is longer with continued improvement over the first 30 cases. The shorter learning curve of LBBAP in conjunction with the superior electrical parameters and simplified programming mean the establishment of a CSP program is potentially easier with LBBAP compared to with HBP.

15.
Cardiol Ther ; 12(1): 21-33, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36417178

RESUMO

Since the introduction of transvenous cardiac pacing leads, pacemaker system design has remained similar for several decades. Progressive miniaturisation of electronic circuitry and batteries has enabled a smaller, single pacing unit comprising the intracardiac electrodes, generator and computer. This review explores the development of leadless pacing, the clinical trials comparing leadless to transvenous pacing in addition to the future developments of multi-chamber leadless pacing.

16.
Eur J Heart Fail ; 25(1): 77-86, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36221809

RESUMO

AIMS: The ARC-HF and CAMTAF trials randomized patients with persistent atrial fibrillation (AF) and heart failure (HF) to early routine catheter ablation (ER-CA) versus pharmacological rate control (RC). After trial completion, delayed selective catheter ablation (DS-CA) was performed where clinically indicated in the RC group. We hypothesized that ER-CA would result in a lower risk of cardiovascular hospitalization and death versus DS-CA in this population. METHODS AND RESULTS: Overall, 102 patients were randomized (age 60 ± 11 years, left ventricular ejection fraction [LVEF] 31 ± 11%): 52 to ER-CA and 50 to RC. After 12 months, patients undergoing ER-CA had improved self-reported symptom scores, lower New York Heart Association class (i.e. better functional capacity), and higher LVEF compared to patients receiving RC alone. During a median follow-up of 7.8 (interquartile range 3.9-9.9) years, 27 (54%) patients in the RC group underwent DS-CA and 34 (33.3%) patients died, including 17 (32.7%) randomized to ER-CA and 17 (34.0%) randomized to RC. Compared with DS-CA, a strategy of ER-CA exhibited similar risk of all-cause mortality (adjusted hazard ratio [aHR] 0.89, 95% confidence interval [CI] 0.44-1.77, p = 0.731) and combined all-cause mortality or cardiovascular hospitalization (aHR 0.80, 95% CI 0.43-1.47, p = 0.467). However, analyses according to treatment received suggested an association between CA and improved outcomes versus RC (all-cause mortality: aHR 0.43, 95% CI 0.20-0.91, p = 0.028; all-cause mortality/cardiovascular hospitalization: aHR 0.48, 95% CI 0.24-0.94, p = 0.031). CONCLUSIONS: In patients with persistent AF and HF, ER-CA produces similar long-term outcomes to a DS-CA strategy. The association between CA as a treatment received and improved outcomes means there is still a lack of clarity regarding the role of early CA in selected patients. Randomized trials are needed to clarify this question.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Disfunção Ventricular Esquerda/tratamento farmacológico , Ablação por Cateter/métodos
17.
Heart Rhythm ; 20(2): 207-216, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36575808

RESUMO

BACKGROUND: Biventricular endocardial pacing (BiV-endo) has demonstrated superior cardiac resynchronization compared to conventional biventricular epicardial pacing (BiV-epi). Left bundle branch area pacing (LBBAP) may also achieve effective cardiac resynchronization therapy (CRT). OBJECTIVE: The purpose of this study was to compare the acute electrical and hemodynamic effects of BiV-epi, BiV-endo, and LBBAP delivered from the LV endocardium and to assess how myocardial scar affects response. METHODS: Eleven patients with heart failure and indications for CRT underwent a temporary pacing study with electrocardiographic imaging (ECGi) and hemodynamic assessment. BiV-endo was delivered by stimulation of the left ventricular (LV) lateral wall, and LBBAP was delivered by stimulation of the LV septum, at the site of a Purkinje potential. LV activation time (LVAT-95), LV dyssynchrony index (LVDI), biventricular activation time (BIVAT-90), and biventricular dyssynchrony index (BIVDI) were calculated. Myocardial scar was assessed using magnetic resonance imaging (MRI). RESULTS: The protocol was completed in 10 patients. Compared to BiV-epi (LVAT-95: 79.2 ± 13.1 ms; LVDI: 26.6 ± 3.4 ms) LV resynchronization was superior during BiV-endo (LVAT-95: 48.5 ± 14.9 ms; P = .001; LVDI: 16.6 ± 6.4 ms; P = .002) and LBBAP (LVAT-95: 48.9 ± 12.5 ms; P = .001; LVDI: 15.3 ± 3.4 ms; P = .001). Biventricular resynchronization was similarly superior during BiV-endo and LBBAP vs BiV-epi (BIVAT-90 and BIVDI; P <.05). The rate of acute hemodynamic responders was higher during BiV-endo (90%) and LBBAP (70%) vs BiV-epi (50%). The benefits of LBBAP (but not BiV-endo) on LV resynchronization were attenuated when septal scar was present in a subset of 8 patients who underwent MRI. CONCLUSION: Our findings suggest superior electrical resynchronization and a higher proportion of acute hemodynamic responders during BiV-endo and LBBAP compared to BiV-epi. Electrical resynchronization was similar between BiV-endo and LBBAP; however, septal scar seemed to attenuate response to LBBAP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Endocárdio , Cicatriz/terapia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Imageamento por Ressonância Magnética , Hemodinâmica/fisiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento
18.
Europace ; 25(2): 561-570, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36358001

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) has been shown to be effective and safe. Limited data are available on LBBAP in the congenital heart disease (CHD) population. This study aims to describe the feasibility and safety of LBBAP in CHD patients compared with non-CHD patients. METHODS AND RESULTS: This is a single-centre, non-randomized observational study recruiting consecutive patients with bradycardia indication. Demographic data, ECGs, imaging, and procedural data including lead parameters were recorded. A total of 39 patients were included: CHD group (n = 13) and non-CHD group (n = 26). Congenital heart disease patients were younger (55 ± 14.5 years vs. 73.2 ± 13.1, P < 0.001). Acute success was achieved in all CHD patients and 96% (25/26) of non-CHD patients. No complications were encountered in either group. The procedural time for CHD patients was comparable (96.4 ± 54 vs. 82.1 ± 37.9 min, P = 0.356). Sheath reshaping was required in 7 of 13 CHD patients but only in 1 of 26 non-CHD patients, reflecting the complex and distorted anatomy of the patients in this group. Lead parameters were similar in both groups; R wave (11 ± 7 mV vs. 11.5 ± 7.5, P = 0.881) and pacing threshold (0.6 ± 0.3 V vs. 0.7 ± 0.3, P = 0.392). Baseline QRS duration was longer in the CHD group (150 ± 28.2 vs. 118.6 ± 26.6 ms, P = 0.002). Despite a numerically greater reduction in QRS and a similar left ventricular activation time (65.9 ± 6.2 vs. 67 ± 16.8 ms, P = 0.840), the QRS remained longer in the CHD group (135.5 ± 22.4 vs. 106.9 ± 24.7 ms, P = 0.005). CONCLUSION: Left bundle branch area pacing is feasible and safe in CHD patients as compared to that in non-CHD patients. Procedural and fluoroscopy times did not differ between both groups. Lead parameters were satisfactory and stable over a short-term follow-up.


Assuntos
Fascículo Atrioventricular , Cardiopatias Congênitas , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/etiologia , Eletrocardiografia/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Resultado do Tratamento
19.
JACC Case Rep ; 4(18): 1213-1217, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36213881

RESUMO

We present the case of an 81-year-old woman with a background of situs inversus with dextrocardia who was successfully treated for tachycardia-bradycardia syndrome with left bundle area pacing. This report describes how this approach can circumvent the limitations of other pacing approaches to optimize patient outcomes. (Level of Difficulty: Intermediate.).

20.
PLoS One ; 17(9): e0273713, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36094912

RESUMO

BACKGROUND: Intense transmission of syphilis has emerged in some Canadian Arctic communities despite screening and prevention efforts. The remoteness of most communities and limited diagnostic infrastructure yield long delays (≥14 days) between screening and treatment of cases. These hamper syphilis control efforts and may contribute to sustained transmission. Syphilis rapid diagnostic tests (RDTs) have been developed to make screening more accessible and to inform clinical decision-making within the same clinical encounter. These RDTs have been successfully deployed in several countries, but not yet in Canada. METHODS AND DESIGN: We describe the methodology of the "Stopping Syphilis Transmission in Arctic Communities Through Rapid Diagnostic Testing" (STAR) study, wherein the clinical and epidemiological impact of deploying a dual syphilis RDT in the context of ongoing transmission in Nunavut and Nunavik will be evaluated. In this prospective multisite field evaluation, sexually active individuals aged ≥14 years at risk for syphilis will be offered screening by an RDT at the point-of-care by non-laboratory trained registered nurses. Whole blood and serum specimens will be concurrently collected, when feasible, for rapid testing with an RDT containing both treponemal and non-treponemal components (Chembio DPP® Syphilis Screen & Confirm) and compared to laboratory-based reference testing according to a reverse sequence algorithm. The diagnostic accuracy of the RDT, using both whole blood and centrifuged serum specimens, will be validated under real-world conditions in remote Northern settings, outside of specialized laboratories. Additionally, screening-to-treatment time, case detection rates, and the number of infectious contacts averted by using the RDT relative to reference testing will be estimated. The impact of both diagnostic approaches on syphilis transmission dynamics will also be modeled. DISCUSSION: This study will provide much needed evidence for strengthening rapid responses to emerging syphilis outbreaks in remote Arctic regions, by supplementing traditional diagnostic strategies with an RDT to rapidly triage patients likely in need of treatment. These results will also inform the development and tailoring of future diagnostic strategies and public health responses to emerging outbreaks in the North.


Assuntos
Sífilis , Regiões Árticas , Canadá/epidemiologia , Humanos , Estudos Prospectivos , Sífilis/diagnóstico , Sífilis/epidemiologia , Sorodiagnóstico da Sífilis/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA