Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 399
Filtrar
1.
Circ Res ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38770652

RESUMO

BACKGROUND: Pathogenic concepts of right ventricular (RV) failure in pulmonary arterial hypertension focus on a critical loss of microvasculature. However, the methods underpinning prior studies did not take into account the 3-dimensional (3D) aspects of cardiac tissue, making accurate quantification difficult. We applied deep-tissue imaging to the pressure-overloaded RV to uncover the 3D properties of the microvascular network and determine whether deficient microvascular adaptation contributes to RV failure. METHODS: Heart sections measuring 250-µm-thick were obtained from mice after pulmonary artery banding (PAB) or debanding PAB surgery and properties of the RV microvascular network were assessed using 3D imaging and quantification. Human heart tissues harvested at the time of transplantation from pulmonary arterial hypertension cases were compared with tissues from control cases with normal RV function. RESULTS: Longitudinal 3D assessment of PAB mouse hearts uncovered complex microvascular remodeling characterized by tortuous, shorter, thicker, highly branched vessels, and overall preserved microvascular density. This remodeling process was reversible in debanding PAB mice in which the RV function recovers over time. The remodeled microvasculature tightly wrapped around the hypertrophied cardiomyocytes to maintain a stable contact surface to cardiomyocytes as an adaptation to RV pressure overload, even in end-stage RV failure. However, microvasculature-cardiomyocyte contact was impaired in areas with interstitial fibrosis where cardiomyocytes displayed signs of hypoxia. Similar to PAB animals, microvascular density in the RV was preserved in patients with end-stage pulmonary arterial hypertension, and microvascular architectural changes appeared to vary by etiology, with patients with pulmonary veno-occlusive disease displaying a lack of microvascular complexity with uniformly short segments. CONCLUSIONS: 3D deep tissue imaging of the failing RV in PAB mice, pulmonary hypertension rats, and patients with pulmonary arterial hypertension reveals complex microvascular changes to preserve the microvascular density and maintain a stable microvascular-cardiomyocyte contact. Our studies provide a novel framework to understand microvascular adaptation in the pressure-overloaded RV that focuses on cell-cell interaction and goes beyond the concept of capillary rarefaction.

2.
Atherosclerosis ; : 117518, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38627162

RESUMO

BACKGROUND AND AIMS: There are a limited number of pharmacologic therapies for coronary artery disease, and few rodent models of occlusive coronary atherosclerosis and consequent myocardial infarction with which one can rapidly test new therapeutic approaches. Here, we characterize a novel, fertile, and easy-to-use HDL receptor (SR-B1)-based model of atherogenic diet-inducible, fatal coronary atherosclerosis, the SR-B1ΔCT/LDLR KO mouse. Additionally, we test intramyocardial injection of Stromal Cell-Derived Factor-1 alpha (SDF-1α), a potent angiogenic cytokine, as a possible therapy to rescue cardiac function in this mouse. METHODS: SR-B1ΔCT/LDLR KO mice were fed the Paigen diet or standard chow diet, and we determined the effects of the diets on cardiac function, histology, and survival. After two weeks of feeding either the Paigen diet (n = 24) or standard chow diet (n = 20), the mice received an intramyocardial injection of either SDF-1α or phosphate buffered saline (PBS). Cardiac function and angiogenesis were assessed two weeks later. RESULTS: When six-week-old mice were fed the Paigen diet, they began to die as early as 19 days later and 50% had died by 38 days. None of the mice maintained on the standard chow diet died by day 72. Hearts from mice on the Paigen diet showed evidence of cardiomegaly, myocardial infarction, and occlusive coronary artery disease. For the five mice that survived until day 28 that underwent an intramyocardial injection of PBS on day 15, the average ejection fraction (EF) decreased significantly from day 14 (the day before injection, 52.1 ± 4.3%) to day 28 (13 days after the injection, 30.6 ± 6.8%) (paired t-test, n = 5, p = 0.0008). Of the 11 mice fed the Paigen diet and injected with SDF-1α on day 15, 8 (72.7%) survived to day 28. The average EF for these 8 mice increased significantly from 48.2 ± 7.2% on day 14 to63.6 ± 6.9% on day 28 (Paired t-test, n = 8, p = 0.003). CONCLUSIONS: This new mouse model and treatment with the promising angiogenic cytokine SDF-1α may lead to new therapeutic approaches for ischemic heart disease.

3.
Clin Transplant ; 38(4): e15302, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38567883

RESUMO

INTRODUCTION: As the adult Fontan population with Fontan associated liver disease continues to increase, more patients are being referred for transplantation, including combined heart and liver transplantation. METHODS: We report updated mortality and morbidity outcomes after combined heart and liver transplant in a retrospective cohort series of 40 patients (age 14 to 49 years) with Fontan circulation across two centers from 2006-2022. RESULTS: The 30-day, 1-year, 5-year and 10-year survival rate was 90%, 80%, 73% and 73% respectively. Sixty percent of patients met a composite comorbidity of needing either post-transplant mechanical circulatory support, renal replacement therapy or tracheostomy. Cardiopulmonary bypass time > 283 min (4.7 h) and meeting the composite comorbidity were associated with mortality by Kaplan Meier analysis. CONCLUSION: Further study to mitigate early mortality and the above comorbidities as well as the high risk of bleeding and vasoplegia in this patient population is warranted.


Assuntos
Cardiopatias Congênitas , Transplante de Coração , Hepatopatias , Transplante de Fígado , Adulto , Humanos , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Transplante de Fígado/efeitos adversos , Estudos Retrospectivos , Hepatopatias/cirurgia , Morbidade , Cardiopatias Congênitas/cirurgia
4.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626077

RESUMO

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Masculino , Animais , Ovinos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cordas Tendinosas/cirurgia , Resultado do Tratamento
5.
NPJ Regen Med ; 9(1): 18, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688935

RESUMO

Complete cardiac regeneration remains an elusive therapeutic goal. Although much attention has been focused on cardiomyocyte proliferation, especially in neonatal mammals, recent investigations have unearthed mechanisms by which non-cardiomyocytes, such as endothelial cells, fibroblasts, macrophages, and other immune cells, play critical roles in modulating the regenerative capacity of the injured heart. The degree to which each of these cell types influence cardiac regeneration, however, remains incompletely understood. This review highlights the roles of these non-cardiomyocytes and their respective contributions to cardiac regeneration, with emphasis on natural heart regeneration after cardiac injury during the neonatal period.

6.
JAMA Netw Open ; 7(3): e241828, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38466306

RESUMO

Importance: The use of ex vivo normothermic organ perfusion has enabled the use of deceased after circulatory death (DCD) donors for heart transplants. However, compared with conventional brain death donation, DCD heart transplantation performed with ex vivo organ perfusion involves an additional period of warm and cold ischemia, exposing the allograft to multiple bouts of ischemia reperfusion injury and may contribute to the high rates of extracorporeal membrane oxygenation usage after DCD heart transplantation. Objective: To assess whether the beating heart method of DCD heart transplantation is safe and whether it has an acceptable rate of extracorporeal membrane oxygenation use postoperatively. Design, Setting, and Participants: This case series includes 10 patients with end-stage heart failure undergoing DCD heart transplantation at a single academic medical center from October 1, 2022, to August 3, 2023. Data were analyzed from October 2022 to August 2023. Interventions: Using a beating heart method of implantation of the donor allograft. Main Outcomes and Measures: The main outcome was primary graft dysfunction necessitating postoperative initiation of mechanical circulatory support. Survival and initiation of mechanical circulatory support were secondary outcomes. Results: In this case series, 10 consecutive patients underwent DCD heart transplantation via the beating heart method. Ten of 10 recipients were male (100%), the mean (SD) age was 51.2 (13.8) years, and 7 (70%) had idiopathic dilated cardiomyopathy. Ten patients (100%) survived, and 0 patients had initiation of extracorporeal membrane oxygenation postoperatively. No other mechanical circulatory support, including intra-aortic balloon pump, was initiated postoperatively. Graft survival was 100% (10 of 10 patients), and, at the time of publication, no patients have been listed for retransplantation. Conclusions and Relevance: In this study of 10 patients undergoing heart transplantation, the beating heart implantation method for DCD heart transplantation was safe and may mitigate ischemia reperfusion injury, which may lead to lower rates of primary graft dysfunction necessitating extracorporeal membrane oxygenation. These results are relevant to institutions using DCD donors for heart transplantation.


Assuntos
Sistema Cardiovascular , Transplante de Coração , Disfunção Primária do Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Coração , Doadores de Tecidos
8.
Artigo em Inglês | MEDLINE | ID: mdl-38320627

RESUMO

OBJECTIVE: The objective of this study is to evaluate survival for combined heart-lung transplant (HLTx) recipients across 4 decades at a single institution. We aim to summarize our contemporary practice based on more than 271 HLTx procedures over 40 years. METHODS: Data were collected from a departmental database and the United Network for Organ Sharing. Recipients younger than age 18 years, those undergoing redo HLTx, or triple-organ system transplantation were excluded, leaving 271 patients for analysis. The pioneering era was defined by date of transplant between 1981 and 2000 (n = 155), and the modern era between 2001 and 2022 (n = 116). Survival analysis was performed using cardinality matching of populations based on donor and recipient age, donor and recipient sex, ischemic time, and sex matching. RESULTS: Between 1981 and 2022, 271 HLTx were performed at a single institution. Recipients in the modern era were older (age 42 vs 34 y; P < .001) and had shorter waitlist times (78 vs 234 days; P < .001). Allografts from female donors were more common in the modern era (59% vs 39%; P = .002). In the matched survival analysis, 30-day survival (97% vs 84%; P = .005), 1-year survival (89% vs 77%; P = .041), and 10-year survival (53% vs 26%; P = .012) significantly improved in the modern era relative to the pioneering era, respectively. CONCLUSIONS: Long-term survival in HLTx is achievable with institutional experience and may continue to improve in the coming decades. Advances in mechanical circulatory support, improved maintenance immunosuppression, and early recognition and management of acute complications such as primary graft dysfunction and acute rejection have dramatically improved the prognosis for recipients of HLTx in our contemporary institutional experience.

9.
JTCVS Open ; 17: 55-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420551

RESUMO

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38238600

RESUMO

PURPOSE: The valve-sparing aortic root replacement (VSARR) procedure was developed to preserve the aortic valve apparatus to replace aneurysmal aortic roots with synthetic grafts and to eliminate associated aortic regurgitation (AR). However, residual post-repair AR is not uncommon and has been found to be associated with recurrent AR and future reoperation. METHODS: We designed and manufactured a 3D-printed, external adjustable symmetrically extensible (EASE) aortic annuloplasty ring that can symmetrically reduce the aortic annulus diameter via a radial constriction, compliant mechanism. An ex vivo porcine VSARR model with annular dilation and AR was developed (n = 4) and used for hemodynamic, echocardiography, and high-speed videography data collection. RESULTS: After ring annuloplasty repair using the EASE aortic ring, the regurgitant fraction decreased from 23.6 ± 6.9% from the VSARR model to 7.4 ± 5.6% (p = 0.05), which was similar to that measured from baseline with a regurgitant fraction of 10.2 ± 3.9% (p = 0.34). The leaflet coaptation height after annuloplasty repair also significantly increased from that measured in VSARR model (0.4 ± 0.1 cm) to 0.9 ± 0.1 cm (p = 0.0004), a level similar to that measured in baseline (1.1 ± 0.1 cm, p = 0.28). CONCLUSION: Using an ex vivo VSARR model, the EASE ring successfully reduced AR by reducing the annular diameter and improving leaflet coaptation. With its broad applicability and ease of use, this device has the potential to have a significant impact on patients suffering worldwide from AR due to root aneurysms.

11.
Innovations (Phila) ; 19(1): 88-91, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38258625

RESUMO

Heart transplantation utilizing deceased after circulatory death (DCD) donors has expanded the donor pool through the use of ex vivo normothermic perfusion. Compared with brain death donation, the conventional method of performing DCD heart transplantation includes an additional period of warm and cold ischemia. We have developed a beating heart implantation technique that obliviates the need for a second cardioplegic arrest and the associated reperfusion injury. We hypothesize this reproducible method may improve short-term and long-term outcomes to mirror results seen in brain death donors and provide details on how to perform beating heart transplantation.


Assuntos
Morte Encefálica , Transplante de Coração , Humanos , Transplante de Coração/métodos , Doadores de Tecidos , Perfusão/métodos
12.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38258541

RESUMO

OBJECTIVES: Artificial neochordae implantation is commonly used for mitral valve (MV) repair. However, neochordae length estimation can be difficult to perform. The objective was to assess the impact of neochordae length changes on MV haemodynamics and neochordal forces. METHODS: Porcine MVs (n = 6) were implanted in an ex vivo left heart simulator. MV prolapse (MVP) was generated by excising at least 2 native primary chordae supporting the P2 segments from each papillary muscle. Two neochordae anchored on each papillary muscle were placed with 1 tied to the native chord length (exact length) and the other tied with variable lengths from 2× to 0.5× of the native length (variable length). Haemodynamics, neochordal forces and echocardiography data were collected. RESULTS: Neochord implantation repair successfully eliminated mitral regurgitation with repaired regurgitant fractions of approximately 4% regardless of neochord length (P < 0.01). Leaflet coaptation height also significantly improved to a minimum height of 1.3 cm compared with that of MVP (0.9 ± 0.4 cm, P < 0.05). Peak and average forces on exact length neochordae increased as variable length neochordae lengths increased. Peak and average forces on the variable length neochordae increased with shortened lengths. Overall, chordal forces appeared to vary more drastically in variable length neochordae compared with exact length neochordae. CONCLUSIONS: MV regurgitation was eliminated with neochordal repair, regardless of the neochord length. However, chordal forces varied significantly with different neochord lengths, with a preferentially greater impact on the variable length neochord. Further validation studies may be performed before translating to clinical practices.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Animais , Suínos , Valva Mitral/cirurgia , Cordas Tendinosas/cirurgia , Desenho de Prótese , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia
13.
J Thorac Cardiovasc Surg ; 167(4): e78-e89, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37160219

RESUMO

OBJECTIVE: Estimating neochord lengths during mitral valve repair is challenging, because approximation must be performed largely based on intuition and surgical experience. Little data exist on quantifying the effects of neochord length misestimation. We aimed to evaluate the impact of neochord length on papillary muscle forces and mitral valve hemodynamics, which is especially pertinent because increased forces have been linked to aberrant mitral valve biomechanics. METHODS: Porcine mitral valves (n = 8) were mounted in an ex vivo heart simulator, and papillary muscles were fixed to high-resolution strain gauges while hemodynamic data were recorded. We used an adjustable system to modulate neochord lengths. Optimal length was qualitatively verified by a single experienced operator, and neochordae were randomly lengthened or shortened in 1-mm increments up to ±5 mm from the optimal length. RESULTS: Optimal length neochordae resulted in the lowest peak composite papillary muscle forces (6.94 ± 0.29 N), significantly different from all lengths greater than ±1 mm. Both longer and shorter neochordae increased forces linearly according to difference from optimal length. Both peak papillary muscle forces and mitral regurgitation scaled more aggressively for longer versus shorter neochordae by factors of 1.6 and 6.9, respectively. CONCLUSIONS: Leveraging precision ex vivo heart simulation, we found that millimeter-level neochord length differences can result in significant differences in papillary muscle forces and mitral regurgitation, thereby altering valvular biomechanics. Differences in lengthened versus shortened neochordae scaling of forces and mitral regurgitation may indicate different levels of biomechanical tolerance toward longer and shorter neochordae. Our findings highlight the need for more thorough biomechanical understanding of neochordal mitral valve repair.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Animais , Suínos , Músculos Papilares/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fenômenos Biomecânicos , Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
15.
JTCVS Tech ; 22: 59-64, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152190
16.
Transpl Int ; 36: 11956, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38152546

RESUMO

The revised United Network for Organ Sharing heart allocation policy was implemented in October 2018. Using a national transplant database, this study evaluated the transplant rate, waitlist mortality, waiting time, and other outcomes of en-bloc heart-lung transplantation recipients. Adult patients registered on the national database for heart-lung transplants before and after the policy update were selected as cohorts. Baseline characteristics, transplant rates, waitlist mortality, waiting times, and other outcomes were compared between the two periods. In total, 370 patients were registered for heart-lung transplants during the pre- and post-periods. There were significantly higher transplant rates, shorter waitlist times, and substantially reduced waitlist mortality in the post-period. Registered patients waitlisted in the post-period had significantly higher utilization of intra-aortic balloon pumps, extracorporeal membrane oxygenation, and overall life support, including ventricular assist devices. Transplant recipients had significantly longer ischemic times, increased transport distances, and shorter waiting times before transplantation in the post-policy period. Transplant recipients held similar short-term survival before and after the policy change (log-rank test, p = 0.4357). Therefore, the revised policy significantly improved access to en-bloc heart-lung allografts compared with the prior policy, with better waitlist outcomes and similar post-transplant outcomes.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Transplante de Coração-Pulmão , Transplante de Pulmão , Adulto , Humanos , Listas de Espera , Políticas , Estudos Retrospectivos , Insuficiência Cardíaca/cirurgia
17.
Bioeng Transl Med ; 8(6): e10575, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38023702

RESUMO

Cardiac electrophysiology mapping and ablation are widely used to treat heart rhythm disorders such as atrial fibrillation (AF) and ventricular tachycardia (VT). Here, we describe an approach for rapid production of three dimensional (3D)-printed mapping devices derived from magnetic resonance imaging. The mapping devices are equipped with flexible electronic arrays that are shaped to match the epicardial contours of the atria and ventricle and allow for epicardial electrical mapping procedures. We validate that these flexible arrays provide high-resolution mapping of epicardial signals in vivo using porcine models of AF and myocardial infarction. Specifically, global coverage of the epicardial surface allows for mapping and ablation of myocardial substrate and the capture of premature ventricular complexes with precise spatial-temporal resolution. We further show, as proof-of-concept, the localization of sites of VT by means of beat-to-beat whole-chamber ventricular mapping of ex vivo Langendorff-perfused human hearts.

18.
JTCVS Open ; 15: 164-172, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808060

RESUMO

Objective: This study aimed to biomechanically evaluate the force profiles on the anterior primary and secondary chordae after neochord repair for anterior valve prolapse with varied degrees of residual mitral regurgitation using an ex vivo heart simulator. Methods: The experiment used 8 healthy porcine mitral valves. Chordal forces were measured using fiber Bragg grating sensors on primary and secondary chordae from A2 segments. The anterior valve prolapse model was generated by excising 2 primary chordae at the A2 segment. Neochord repair was performed with 2 pairs of neochords. Varying neochord lengths simulated postrepair residual mitral regurgitation with regurgitant fraction at >30% (moderate), 10% to 30% (mild), and <10% (perfect repair). Results: Regurgitant fractions of baseline, moderate, mild, and perfect repair were 4.7% ± 0.8%, 35.8% ± 2.1%, 19.8% ± 2.0%, and 6.0% ± 0.7%, respectively (P < .001). Moderate had a greater peak force of the anterior primary chordae (0.43 ± 0.06 N) than those of baseline (0.19 ± 0.04 N; P = .011), mild (0.23 ± 0.05 N; P = .041), and perfect repair (0.21 ± 0.03 N; P = .006). In addition, moderate had a greater peak force of the anterior secondary chordae (1.67 ± 0.17 N) than those of baseline (0.64 ± 0.13 N; P = .003), mild (0.84 ± 0.24 N; P = .019), and perfect repair (0.68 ± 0.14 N; P = .001). No significant differences in peak and average forces on both primary and secondary anterior chordae were observed between the baseline and perfect repair as well as the mild and perfect repair. Conclusions: Moderate residual mitral regurgitation after neochord repair was associated with increased anterior primary and secondary chordae forces in our ex vivo anterior valve prolapse model. This difference in chordal force profile may influence long-term repair durability, providing biomechanical evidence in support of obtaining minimal regurgitation when repairing mitral anterior valve prolapse.

19.
JACC Cardiovasc Interv ; 16(17): 2112-2119, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704297

RESUMO

BACKGROUND: The functional SYNTAX score (FSS), which incorporates functional information as assessed by fractional flow reserve (FFR), is a better predictor of outcome after percutaneous coronary intervention (PCI) in patients with less complex coronary artery disease (CAD). OBJECTIVES: This study sought to test the prognostic value of the FSS in patients with complex CAD eligible for coronary artery bypass grafting (CABG). METHODS: The FAME 3 (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation 3) trial compared FFR-guided PCI with CABG in patients with angiographic 3-vessel CAD. In this prespecified substudy, the angiographic core laboratory calculated the SYNTAX score (SS) and then the FSS by eliminating lesions that were not significant based on FFR. Outcomes in the PCI patients based on the FSS and the SS were compared to each other and to the patients treated with CABG. RESULTS: The FSS reclassified more than one-quarter of patients from an SS >22 to an FSS ≤22. In the 50% of PCI patients who had an FSS ≤22, the primary endpoint occurred at a similar rate to patients treated with CABG (P = 0.77). The primary endpoint in patients without functionally significant 3-vessel CAD was similar to the CABG group (P = 0.97). The rate of myocardial infarction and revascularization among all deferred lesions was 0.5% and 3.2%, respectively. CONCLUSIONS: By measuring the FSS, one can identify 50% of patients who have a similar outcome at 1 year with PCI compared with CABG. Lesions deferred from PCI based on FFR have a low event rate.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Doenças Vasculares , Humanos , Angiografia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA