Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Hand Surg Eur Vol ; 47(8): 787-797, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35701990

RESUMO

This is the second of a two-part review article on the management of conflict injuries, focused on the reconstructive strategies for bone, nerve and soft tissue and to provide guidance on assessing and managing common complications associated with complex upper limb injuries. Following assessment and early surgical management, the conflict casualty will require further wound evaluation and planning prior to definitive reconstruction of limb injuries. Surgical management of the upper limb injury should aim, where possible, to preserve the limb and allow functional reconstruction. The principles of the second look procedure are to assess wound progression, further reduce the risk of infection and plan definitive reconstruction with adequate soft tissue cover. The prerequisites for successful surgical reconstruction are a stable patient, combined orthoplastic surgery expertise supported by physiotherapists and hand therapists.


Assuntos
Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Humanos , Procedimentos de Cirurgia Plástica/métodos , Lesões dos Tecidos Moles/etiologia , Lesões dos Tecidos Moles/cirurgia , Retalhos Cirúrgicos/cirurgia , Resultado do Tratamento , Extremidade Superior/lesões , Extremidade Superior/cirurgia
2.
J Hand Surg Eur Vol ; 47(7): 687-697, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35579217

RESUMO

Upper limb injuries are common in conflict zones. The functions of the upper limb are impossible to replicate with prosthetic replacement and wherever possible attempts should be made to preserve the limb with further secondary reconstruction aimed at restoration of function. Casualty assessment, haemorrhage control and resuscitation are simultaneously undertaken at the receiving medical facility. Primary surgical management involves decontamination and debridement, skeletal stabilization, restoration of vascularity, compartment fasciotomy where indicated and wound temporization with dressings. Operative findings and interventions should be documented and if evacuation of the casualty is possible, copies should be provided in the medical records to facilitate communication in the chain of care. Secondary procedures are required for further assessment and debridement prior to planning reconstruction and definitive fracture stabilization, nerve repair, wound cover or closure.


Assuntos
Procedimentos de Cirurgia Plástica , Extremidade Superior , Bandagens , Humanos , Extremidade Superior/lesões , Extremidade Superior/cirurgia
4.
Plast Reconstr Surg ; 143(4): 880e-886e, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30921156

RESUMO

Since the 1960s, skin has been considered to be the most allogenic tissue in humans. This tenet has remained unquestioned in the reconstructive transplant arena, which has led to skin serving as the sole monitor for early rejection in vascularized composite allotransplantation. In this article, the authors question the validity of this belief. The authors' hypothesis is that skin is not always an accurate monitor of rejection in the deep tissues, thus questioning the positive and negative predictive value of the punch biopsy for suspected vascularized composite allotransplantation rejection. A search was carried out identifying vascularized composite allotransplantation publications where the allogenicity of transplanted skin was evaluated. Eighteen publications claimed skin was found to be the most allogenic tissue in humans, justifying its use as a superior monitor for rejection. Eight publications demonstrated skin to be a poor monitor of rejection deeper to the skin. Two vascularized composite allotransplantation animal studies reported skin rejecting simultaneously with the deeper tissues. Finally, three publications discussed a skin and kidney allograft, transplanted simultaneously, indicating skin allogenicity was equivalent to the that of the kidney allograft. Much of the literature in human vascularized composite allotransplantation claims skin to be an excellent monitor of the deep tissues. The conclusion from this study is that skin does not always function as a good monitor for what could be rejecting in the deep tissues. The authors believe continued research is necessary to focus on expanding novel monitoring techniques and technologies to accurately diagnose vascularized composite allotransplantation rejection without tissue destruction.


Assuntos
Aloenxertos Compostos/fisiologia , Fenômenos Fisiológicos da Pele , Animais , Aloenxertos Compostos/imunologia , Rejeição de Enxerto/fisiopatologia , Humanos , Modelos Animais , Terminologia como Assunto , Imunologia de Transplantes/fisiologia , Alotransplante de Tecidos Compostos Vascularizados/tendências
5.
Plast Reconstr Surg ; 143(3): 637e-643e, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30624339

RESUMO

BACKGROUND: From 1996 to 2000, Diefenbeck et al. carried out six knee vascularized composite allotransplants. The allotransplants were composed of bone, soft tissue, and femoral vascular pedicle (25 to 40 cm). All rejected between 14 and 56 months. Failures were attributed to chronic rejection. In 2008, the Louisville team lost their fourth patient's hand transplant at 8 months. During the rejection workup, intraoperative findings noted a thickened arterial pedicle attributed to intimal hyperplasia with significant fibrotic perivascular tissue and a near "no-flow phenomenon." No cutaneous rejection was appreciated and failure was attributed to chronic rejection. METHODS: Data were collected from two teams, one in Germany and the other in Louisville, Kentucky. The population under study consisted of the six knee and one hand transplants. The factor of interest was the long donor arterial pedicle. The outcome measurements were transplant survival time and histopathologic results. RESULTS: There are only seven published vascularized composite allotransplant cases where a donor artery longer than 25 cm was used. This cohort represents a 100 percent accelerated failure rate. The cause of these losses remains unexplained. The donor arteries suffered from T-cell-mediated rejection and ischemia-induced media/adventitial necrosis. CONCLUSIONS: We hypothesize that the donor artery rejected at an accelerated rate because of ischemia caused by disruption of the external vasa vasorum in conjunction with intimal hyperplasia induced by T-cell-mediated rejection that led to disruption of the Windkessel effect. Loss of this effect presented as intimal hyperplasia accelerated by ischemia causing an expedited transplant failure. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, V.


Assuntos
Artérias/fisiologia , Aloenxertos Compostos/irrigação sanguínea , Rejeição de Enxerto/fisiopatologia , Isquemia/fisiopatologia , Alotransplante de Tecidos Compostos Vascularizados/efeitos adversos , Artérias/transplante , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto/fisiologia , Transplante de Mão/efeitos adversos , Humanos , Hiperplasia/imunologia , Hiperplasia/fisiopatologia , Isquemia/imunologia , Joelho/cirurgia , Fluxo Sanguíneo Regional/fisiologia , Linfócitos T/imunologia , Fatores de Tempo , Túnica Íntima/patologia , Vasa Vasorum/patologia
6.
J Hand Surg Am ; 43(5): 432-438, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29398329

RESUMO

PURPOSE: Smoking conventional cigarettes reduces peripheral microcirculation leading to worse outcomes after hand surgery. Patients are increasingly using electronic cigarettes (eCigarettes); however, there is no published research investigating the effects of eCigarettes on hand microcirculation. METHODS: Fifteen healthy subjects with a median age of 26 years were recruited: 7 smokers and 8 nonsmokers. A noninvasive O2C laser Doppler probe measured a baseline control reading at deep (7-mm) and superficial (3-mm) levels. Participants commenced a 5-minute smoking protocol of nonnicotine (0-mg) eCigarettes with continuous microcirculation measurements during smoking and for 20 minutes afterward. This was repeated with nicotine (24-mg) eCigarettes. Readings were averaged over 5-minute periods and standardized as a percentage of baseline. A linear mixed-effects model with an unstructured covariance structure was used to analyze the data. RESULTS: Smokers had a statistically significant reduction in hand microcirculation during and up to 20 minutes after smoking a 24-mg eCigarette. There was a maximum reduction of 77% in superficial flow and 29% in deep flow. After smoking a 0-mg eCigarette, smokers demonstrated an increase in superficial flow of up to 70% with no change in deep flow. Nonsmokers had no statistically significant change in superficial or deep flow after smoking either eCigarette. CONCLUSIONS: A 24-mg eCigarette significantly reduced smokers' hand microcirculation during and after smoking. Microcirculation increased in smokers after inhalation of a 0-mg eCigarette. CLINICAL RELEVANCE: We advise smokers undergoing hand surgery to avoid high-dose eCigarettes and, if necessary, to use 0-mg eCigarettes as an alternative.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Mãos/irrigação sanguínea , Microcirculação , Adulto , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Estimulantes Ganglionares/administração & dosagem , Estimulantes Ganglionares/efeitos adversos , Voluntários Saudáveis , Humanos , Fluxometria por Laser-Doppler , Nicotina/administração & dosagem , Nicotina/efeitos adversos , Adulto Jovem
8.
Injury ; 48(1): 70-74, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27609650

RESUMO

INTRODUCTION: The recent Afghanistan conflict caused a higher proportion of casualties with facial injuries due to both the increasing effectiveness of combat body armour and the insurgent use of the improvised explosive device (IED). The aim of this study was to describe all injuries to the face sustained by UK service personnel from blast or gunshot wounds during the highest intensity period of combat operations in Afghanistan. METHODS: Hospital records and Joint Theatre Trauma Registry data were collected for all UK service personnel killed or wounded by blast and gunshot wounds in Afghanistan between 01 April 2006 and 01 March 2013. RESULTS: 566 casualties were identified, 504 from blast and 52 from gunshot injuries. 75% of blast injury casualties survived and the IED was the most common mechanism of injury with the mid-face the most commonly affected facial region. In blast injuries a facial fracture was a significant marker for increased total injury severity score. A facial gunshot wound was fatal in 53% of cases. The majority of survivors required a single surgical procedure for the facial injury but further reconstruction was required in 156 of the 375 of survivors aero medically evacuated to the UK. CONCLUSIONS: The presence and pattern of facial fractures was significantly different in survivors and fatalities, which may reflect the power of the blast that these cohorts were exposed to. The Anatomical Injury Scoring of the Injury Severity Scale was inadequate for determining the extent of soft tissue facial injuries and did not predict morbidity of the injury.


Assuntos
Campanha Afegã de 2001- , Traumatismos por Explosões/cirurgia , Traumatismos Faciais/cirurgia , Medicina Militar , Militares , Procedimentos de Cirurgia Plástica , Ferimentos por Arma de Fogo/cirurgia , Adulto , Traumatismos por Explosões/psicologia , Traumatismos por Explosões/reabilitação , Traumatismos Faciais/psicologia , Traumatismos Faciais/reabilitação , Humanos , Escala de Gravidade do Ferimento , Militares/psicologia , Sistema de Registros , Estudos Retrospectivos , Reino Unido , Ferimentos por Arma de Fogo/psicologia , Ferimentos por Arma de Fogo/reabilitação
10.
Ann Surg ; 261(4): 800-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25347150

RESUMO

OBJECTIVE: To develop and validate a robust, objective mobility assessment tool, Hamlyn Mobility Score (HMS), using a wearable motion sensor. BACKGROUND: Advances in reconstructive techniques allow more limbs to be salvaged. However, evidence demonstrating superior long-term outcomes compared with amputation is unavailable. Lack of access to quality regular functional mobility status may be preventing patients and health care staff from optimizing rehabilitation programs and evaluating the reconstructive services. METHODS: In this prospective cohort study, 20 patients undergoing lower limb reconstruction and 10 age-matched controls were recruited. All subjects completed the HMS activity protocol twice under different instructors at 3 months postoperatively, and again at 6 months, while wearing an ear-worn accelerometer. Demographic and clinical data were also collected including a short-form health survey (SF-36). HMS parameters included standard test metrics and additional kinematic features extracted from accelerometer data. A psychometric evaluation was conducted to ascertain reliability and validity. RESULTS: The HMS demonstrated excellent reliability (intraclass correlation coefficient >0.90, P < 0.001) and internal consistency (Cronbach α = 0.897). Concurrent validity was demonstrated by correlation between HMS and SF-36 scores (Spearman ρ = 0.666, P = 0.005). Significant HMS differences between healthy subjects and patients, stratified according to fracture severity, were shown (Kruskal-Wallis nonparametric 1-way analysis of variance, χ = 21.5, P < 0.001). The HMS was 50% more responsive to change than SF-36 (effect size: 1.49 vs 0.99). CONCLUSIONS: The HMS shows satisfactory reliability and validity and may provide a platform to support adaptable, personalized rehabilitation and enhanced service evaluation to facilitate optimal patient outcomes.


Assuntos
Fraturas Expostas/reabilitação , Limitação da Mobilidade , Psicometria/métodos , Recuperação de Função Fisiológica , Fraturas da Tíbia/reabilitação , Atividades Cotidianas , Adulto , Fenômenos Biomecânicos , Estudos de Coortes , Avaliação da Deficiência , Feminino , Seguimentos , Fraturas Expostas/cirurgia , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Psicometria/instrumentação , Reprodutibilidade dos Testes , Inquéritos e Questionários , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA