Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Vaccine Immunol ; 17(6): 1034-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20410326

RESUMO

A simplified lateral-flow assay for the detection of antibodies to HIV using magnetic-bead conjugates and multibranched peptides from both HIV-1 and HIV-2 was developed. Magnetic immunochromatography testing (MICT) uses a standard lateral-flow platform that incorporates magnetic-bead conjugates for quantitative measurement of the magnetic field distortion associated with the bound magnetic conjugate (reported as adjusted relative magnetic units [MAR]). The results of the optimized MICT assay were compared to standard enzyme immunoassay (EIA) and Western blotting (WB) results using a blinded 649-member panel of specimens from the United States, Cameroon, and West Africa. The panel was comprised of samples from individuals infected with various HIV-1 subtypes (n = 234) or HIV-2 (n = 65) and HIV-seronegative specimens (n = 350). Additionally, 13 HIV-1 seroconversion panels (total specimens = 85), a worldwide panel containing seven of the major circulating HIV-1 subtypes (n = 18), an HIV-2 panel, an HIV-1/HIV-2 mixed panel, and 100 prospective specimens were tested with completely concordant results. Assay reproducibility (observed MAR) for both intra- and interrun testing was excellent, with coefficients of variation of <12%. MICT can provide a rapid, low-cost method of determining HIV antibody status requiring no subjective interpretations.


Assuntos
Especificidade de Anticorpos , Anticorpos Anti-HIV/sangue , Antígenos HIV/imunologia , Infecções por HIV/diagnóstico , HIV-1/imunologia , HIV-2/imunologia , Sorodiagnóstico da AIDS , Cromatografia/métodos , Antígenos HIV/química , Infecções por HIV/imunologia , Infecções por HIV/virologia , Separação Imunomagnética/métodos , Peptídeos/imunologia , Fatores de Tempo
2.
J Virol Methods ; 160(1-2): 14-21, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19482361

RESUMO

Detection of human immunodeficiency virus (HIV) infections has been enhanced by incorporating p24 antigen detection with current HIV antibody detection using enzyme immunoassays (EIAs). However, screening for HIV antibodies has increased through the use of rapid, lateral-flow HIV antibody detection assays that currently do not have the capability to detect HIV p24 antigen. In this report, a lateral-flow based assay using super-paramagnetic particles as the detection marker was developed for the detection of HIV-1 p24 antigen. This magnetic immuno-chromatographic test (MICT) uses an inexpensive, low-maintenance instrument that detects the magnetic moment of the super-paramagnetic particles in a magnetic field. MICT is simple to perform, provides a numerical output for easier determination of reactive results and can be completed in 40min. The lower limit of detection for HIV-1 p24 spiked into assay sample buffer and 50% plasma was 30pg/ml for both. Detection of HIV-1 p24 antigen at 50pg/ml was reproducible in both inter-run and intra-run assays with coefficients of variation of <13%. Furthermore, the MICT p24 assay was able to detect intact virus spiked into 50% plasma (lower detection limit of approximately 250,000 viral RNA copies/ml). MICT detection of increasing HIV-1 p24 levels in commercially available seroconversion panels by MICT was only slightly later than that detected by much more complex EIAs. MICT could provide a simple, low-cost, and portable method for rapid HIV-1 p24 detection in a variety of testing environments.


Assuntos
Antígenos Virais/sangue , Cromatografia/métodos , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/diagnóstico , Separação Imunomagnética/métodos , Plasma/virologia , Animais , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA