Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 14(31): 3021-3032, 2022 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-35916160

RESUMO

Metamitron (MTM) is a typical and widely used triazine herbicide in agricultural production. Its moderate toxicity and high residue in the environment have deleterious impacts on human health. The establishment of a rapid and efficient MTM detection method is of great significance. In this study, a magnetic-bead SELEX (systematic evolution of ligands by exponential enrichment) system was developed to select the MTM aptamers with high affinity and specificity. Through 10 rounds of screening, six candidate aptamers with the highest abundance were obtained by high-throughput sequencing. The homology, secondary structure, and affinity analyses were performed. The aptamer named MTM-6 was selected as the optimal aptamer with the dissociation constant (Kd) value of 16 nM. Then, a colorimetric detection method for MTM based on aptamer MTM-6 and the aggregation of gold nanoparticles (AuNPs) induced by NaCl was established with a linear range from 20 to 1000 nM (R = 0.9966) and a limit of detection (LOD) of 4.58 nM. The average recovery rate of MTM in the application of actual aqueous samples ranged from 95.40 to 107.83% with a relative standard deviation (RSD) from 1.11 to 3.48%. With considerable sensitivity and specificity, this colorimetric aptasensor is convenient and efficient, and shows bright application potential in MTM detection in aqueous samples.


Assuntos
Aptâmeros de Nucleotídeos , Nanopartículas Metálicas , Aptâmeros de Nucleotídeos/química , Colorimetria/métodos , DNA de Cadeia Simples , Ouro/química , Humanos , Fenômenos Magnéticos , Nanopartículas Metálicas/química , Técnica de Seleção de Aptâmeros/métodos , Triazinas
2.
Talanta ; 250: 123708, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35752088

RESUMO

Netilmicin (NET) is an antibiotic widely used in healthcare and agriculture, but it can accumulate in the environment to threat human health. Netilmicin (NET) is an antibiotic used for veterinary purposes, for human therapy and for agricultural purposes. Therefore, there is a need to develop high-sensitive measuring methods to detect NET. Aptamer-based detecting methods are highly sensitive, inexpensive, and portable. In this study, we developed an aptamer-based fluorescence method to detect and quantify NET. NET was first conjugated to magnetic beads by amidation reaction and then NET-coated beads were used as the stationary phase to isolate aptamers by systematic evolution of ligands by exponential enrichment (SELEX) screening method. After ten rounds of SELEX screening, 32 aptamers with NET-binding affinity were obtained and the candidate aptamer APT-21 was finally chosen by comprehensively comparing their secondary structure characters and NET-binding affinity. APT-21 bound to NET with high affinity (Kd = 194.1 nmol/L) and high specificity that it displayed low cross-binding activities on 7 different structural analogs. We also developed a fluorometric assay using SYBR Green I (SG-I) and the APT-21. Key experimental parameters were optimized, including buffer system, SG-I and APT-21 reaction time, SG-I concentration, and aptamer concentration, to improve the detecting sensitivity. Our results suggest that the low limit of detection (LOD) of this method reached a low level of 1.95 nM and it also exhibited a good linear range up to 200 nM. Moreover, we successfully applied our method to detect the NET spiked in tap water and river water with good recoveries in the range from 97% to 111%. In conclusion, our current study isolated a NET-specific aptamer and developed an aptamer-based quantification method, which is promising to apply to detect NET in environmental samples.


Assuntos
Aptâmeros de Nucleotídeos , Antibacterianos/análise , Aptâmeros de Nucleotídeos/química , Dimaprit/análogos & derivados , Humanos , Netilmicina , Técnica de Seleção de Aptâmeros/métodos , Água
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 34(4): 250-4, 2010 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-21033108

RESUMO

This paper provides a new design of 12-element array ultrasound transducer. By modeling the beam field model of single element and array and comparing simulated and real ultrasound beam field test data, it can be demonstrated that 12-element array ultrasound transducer has a much better field performance than the 8-element transducer.


Assuntos
Ultrassonografia Doppler/instrumentação , Ultrassonografia Pré-Natal/instrumentação , Desenho de Equipamento
4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 21(6): 1011-3, 2004 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-15646354

RESUMO

In order to monitor the fetus in labor, the signal characteristic from fetal scalp electrode is researched, An adaptation algorithm and a peak to peak detecting technology are adopted in signal processing, and an adaptation gain control method is used to eliminate disturber from base-line shift. A fetal ECG monitoring system is designed on the basis of C8051F020 MCU.


Assuntos
Eletrocardiografia/instrumentação , Coração Fetal/fisiologia , Monitorização Fetal/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Adulto , Feminino , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA