Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sci Data ; 11(1): 13, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167545

RESUMO

Early and accurate diagnosis of ear deformities in newborns is crucial for an effective non-surgical correction treatment, since this commonly seen ear anomalies would affect aesthetics and cause mental problems if untreated. It is not easy even for experienced physicians to diagnose the auricular deformities of newborns and the classification of the sub-types, because of the rich bio-metric features embedded in the ear shape. Machine learning has already been introduced to analyze the auricular shape. However, there is little publicly available datasets of ear images from newborns. We released a dataset that contains quality-controlled photos of 3,852 ears from 1,926 newborns. The dataset also contains medical diagnosis of the ear shape, and the health data of each newborn and its mother. Our aim is to provide a freely accessible dataset, which would facilitate researches related with ear anatomies, such as the AI-aided detection and classification of auricular deformities and medical risk analysis.


Assuntos
Orelha Externa , Aprendizado de Máquina , Humanos , Recém-Nascido , Orelha Externa/anormalidades , Orelha Externa/cirurgia , Médicos , Medição de Risco
2.
Laryngoscope ; 134(1): 148-153, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37243347

RESUMO

Hearing improvement is another basic requirement for microtia patients in addition to aesthetic needs. This quantitative framework fabrication method can reduce the learning curve, obtain satisfactory aesthetic results with few complications, and reserve a certain space for future canalplasty. Laryngoscope, 134:148-153, 2024.


Assuntos
Microtia Congênita , Cartilagem Costal , Procedimentos de Cirurgia Plástica , Humanos , Cartilagem Costal/transplante , Orelha Externa/cirurgia , Microtia Congênita/cirurgia , Cartilagem/transplante
3.
J Clin Med ; 12(18)2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37762842

RESUMO

Bone conduction devices (BCDs) are widely used in the treatment of conductive hearing loss (CHL), but their applications on unilateral CHL (UCHL) patients remain controversial. To evaluate the effects of BCDs in UCHL, a systematic search was undertaken until May 2023 following the PRISMA guidelines. Among the 391 references, 21 studies met the inclusion criteria and were ultimately selected for review. Data on hearing thresholds, speech recognition, sound localization, and subjective questionnaire outcomes were collected and summarized. Moderate hearing threshold improvements were found in UCHL patients aided with BCDs. Their speech recognition abilities improved significantly. However, sound localization results showed wide individual variations. According to subjective questionnaires, BCDs had an overall positive influence on the daily life of UCHL patients, although several unfavorable experiences were reported by some of them. We concluded that the positive audiological benefits and subjective questionnaire results have made BCDs a credible intervention for UCHL patients. Before final implantations, UCHL patients should first go through a period of time when they were fitted with non-implantable BCDs as a trial.

4.
Front Cell Neurosci ; 16: 836093, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35480960

RESUMO

Background: Endolymphatic hydrops (EH) is considered as the pathological correlate of Menière's disease (MD) and cause of hearing loss. The mechanism of EH, remaining unrevealed, poses challenges for formalized clinical trials. Objective: This study aims to investigate the development of hearing loss, as well as the effect of dehydration treatment on EH animal models. Methods: In this study, different severity EH animal models were created. The laser Doppler vibrometer (LDV) and auditory brainstem responses (ABR) were used to study the effects of EH and the dehydration effects of mannitol. The LDV was used to measure the vibration of the round window membrane (RWM) reflecting the changes in inner ear impedance. ABR was used to evaluate the hearing changes. Furthermore, tissue section and scanning electron microscopy (SEM) observations were used to analyze the anatomical change to the cochlea and outer hair cells. Results: The RWM vibrations decreased with the severity of EH, indicating an increase in the cochlear impedance. The dehydration therapy lowered the impedance to restore acoustic transduction in EH 10- and 20-day animal models. Simultaneously, the ABR thresholds increased in EH models and were restored after dehydration. Moreover, a difference in the hearing was found between ABR and LDV results in severe EH animal models, and the dehydration therapy was less effective, indicating a sensorineural hearing loss (SNHL). Conclusion: Endolymphatic hydrops causes hearing loss by increasing the cochlear impedance in all tested groups, and mannitol dehydration is an effective therapy to restore hearing. However, SNHL occurs for the EH 30-day animal models, limiting the effectiveness of dehydration. Our results suggest the use of dehydrating agents in the early stage of EH.

8.
Hear Res ; 378: 101-107, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30773325

RESUMO

BACKGROUND: As an alternative pathway to air conduction, bone conduction is a multipathway process that transmits sound energy to the inner ear through the skull in general. Based on this mechanism, bone conduction devices (BCDs) have been used widely in the rehabilitation of hearing loss. Although great efforts have been devoted to improving BCDs, drawbacks still exist in most categories of BCDs due to the complicated process of bone conduction. We hypothesized that if a bone conduction transducer was placed on the cochlea to stimulate it directly, the attenuation would be minimized, and the frequency dependency would be different from that of the vibratory response induced by traditional BCDs. This study aimed to explore the feasibility of direct promontory stimulation and to investigate its frequency-response characteristics. METHODS: Measurements were conducted in twelve cat ears. To stimulate the promontory directly, the floating mass transducer (FMT) of the Vibrant Soundbridge© (VSB) implant was glued to the promontory coupled with an oval window (OW) coupler. Auditory brainstem response (ABR) and laser Doppler vibrometry (LDV) measurements were used to evaluate the auditory response induced by the FMT. In both measurements, the FMT was driven by direct voltage stimuli. RESULTS: ABR waves could be induced under direct promontory stimulation by the FMT. In the frequency range of 1-12 kHz, the variation in the voltage threshold level were limited to 16 dB SPL with a maximum of 0.2 V at 1 kHz and a minimum of 0.04 V at 10 kHz. In the LDV measurements and the relative motion of the round window membrane (RWM) and the promontory were used to evaluate the cochlear response. The LDV results indicated a weak frequency dependency from 1 to 12 kHz. CONCLUSION: Different from traditional stimulation via transcranial bone conduction, direct promontory stimulation is a new method in which a small bone conduction transducer stimulates the cochlear shell directly. The current experimental data demonstrate that it is feasible to generate sensations through bone conduction by stimulating the cochlea directly. Furthermore, the cochlear response induced by this type of stimulus in cats was weakly frequency dependent at frequencies ranging from 1 to 12 kHz. This study may provide a basis for the design of new transducers that can perform well over a wide range of frequencies.


Assuntos
Condução Óssea , Cóclea/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico , Auxiliares de Audição , Estimulação Acústica , Animais , Limiar Auditivo , Gatos , Cóclea/diagnóstico por imagem , Desenho de Equipamento , Estudos de Viabilidade , Fluxometria por Laser-Doppler , Movimento (Física) , Pressão , Som , Fatores de Tempo , Vibração , Microtomografia por Raio-X
9.
Artigo em Chinês | MEDLINE | ID: mdl-17283543

RESUMO

OBJECTIVE: To determine the optimal drill area on the footplate with the 3D measurements of the stapes and the vestibular end organs. METHODS: Four temporal bones were extracted from the fresh cadavers and undecalcified polymer-embedded. After serially sectioning, image processing and the 3D precisely reconstruction, a local Cartesian coordinates was established in which the tympanic surface of the footplate was supposed to be XY plane and the Z coordinate axis passed through the central point of the footplate and was vertical to the XY plane. The configurations of the utricle and saccule were delineated quantitatively, and then any distance between one point on the surface of the footplate and another point on the surface of the utricle or saccule and its orientation can be measured. RESULTS: There was a "V" shaped cleft between the utricle and the saccule. The angle of the" V" shaped cleft was 50.31 +/- 19.90 (17.00 - 68.00) degrees. The apex of the cleft directed anterosuperiorly and approached the footplate center, while beneath the posteroinferior part of the footplate was an open and deep area. The vertical distance from the center point of the footplate to the vestibular end organs was (2.20 +/- 0.548) mm, the maximum of 3.0 mm and the minimum of 1.6 mm. CONCLUSIONS: The posterior and inferior quadrant of the footplate may be the optimal drill area for the fenestra.


Assuntos
Imageamento Tridimensional , Sáculo e Utrículo/anatomia & histologia , Estribo/anatomia & histologia , Adulto , Humanos , Osso Temporal/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA