Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 149, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475690

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a prevalent disease that triggers systemic pathological changes including cardiac, respiratory, hepatic and digestive, hematopoietic, renal and skin issues. The burden of extra-cardiac manifestations has not been well described in TR patients and the clinical impact is unknown. METHODS: Patients with severe or more-than-severe TR during hospitalization, who did not have any previous cardiac procedures, hemodynamically significant congenital heart disease or concomitant severe aortic or mitral valve disease, were retrospectively analyzed. Pre-specified criteria and diagnosis of baseline characteristics were used to evaluate the presence of extra-cardiac manifestations secondary to TR after excluding comorbidities that may also lead to corresponding abnormalities. Extra-cardiac involvements encompass respiratory, hepatic and, digestive, renal, hematopoietic and dermatic system. Staging criteria are defined as no extra-cardiac system involvement in Stage 1, one in Stage 2, at least two extra-cardiac involvements in Stage 3 and any end-stage organ failure in Stage 4. A telephone follow-up was conducted to record the composite endpoint namely all-cause death or cardiac rehospitalization after the index hospitalization. RESULTS: A total of 258 patients were identified with a median age of 73 (interquartile range [IQR]: 62-83) years and 52.3% were female. Severe TR and more-than-severe TR patients accounted for 92.6% and 7.4% of the cohort. There were 20.5%, 27.5%, 37.6% and 14.3% of patients from Stage 1 to 4 respectively. The follow-up time was at a median of 251 (IQR: 183-324) days. TR Patients in Stage 3&4 were at an increased risk with borderline statistical significance to experience the composite endpoint compared to patients in Stage 1&2 (odds ratio [OR] 1.9, 95% confidence interval [CI] 1.0 to 3.7, P = 0.049). CONCLUSIONS: Approximately half of patients with at least severe TR presented with two or more extra-cardiac systemic manifestations, which may incur a 1.9-fold higher risk of all-cause death or cardiac rehospitalization than TR patients with one or less extra-cardiac involvement.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/etiologia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Medição de Risco , Hemodinâmica
2.
BMJ Open ; 13(12): e078061, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110378

RESUMO

INTRODUCTION: Decisions regarding the optimal timing of intervention for asymptomatic aortic stenosis (AS) are controversial. The study aims to identify potential risk factors for asymptomatic patients with severe AS that are associated with worse prognosis and to evaluate the benefits of early interventions for asymptomatic patients presenting with one or more additional risk factors. METHODS AND ANALYSIS: This is a non-interventional, prospective, open-label, multicentre registry study across China. A total of 1000 patients will be enrolled and categorised as symptomatic or asymptomatic. The primary endpoint is the occurrence of all-cause mortality, stroke, acute myocardial infarction and heart failure-related hospitalisation at 1-year follow-up. In asymptomatic severe AS patients presenting with one or more risk factors, the occurrence rate of the primary endpoint between those who undergo transcatheter aortic valve replacement (TAVR) and those who do not will be compared. We will also compare the occurrence rate of the primary endpoint for asymptomatic severe AS patients with additional risk factors who undergo TAVR with those presenting with symptoms. This study is believed to provide additional evidence to help clinicians identify and refer severe AS patients who are asymptomatic but present with additional risk factors for early intervention of TAVR. ETHICS AND DISSEMINATION: The study protocol has been approved by the local ethics committee of each participating site: West China Hospital, Sichuan University; Sir Run Run Shaw Hospital, Zhejiang University School of Medicine; Second Hospital of Hebei Medical University; Tianjin Chest Hospital; and First Affiliated Hospital of Nanchang University. All participants will provide written informed consent. Study results will be published through academic conferences and peer-reviewed journals. TRIAL REGISTRATION: This study was registered at the Chinese Clinical Trial Registry (https:// www.chictr.org.cn), with the registration number ChiCTR2200064853.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Circ Cardiovasc Interv ; 16(12): e013083, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37846559

RESUMO

BACKGROUND: Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. The study aims to compare the outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy. METHODS: We enrolled consecutive patients undergoing transcatheter aortic valve replacement for severe AS between 2012 and 2022 in this single-center retrospective cohort study. The primary outcome was mortality, while secondary outcomes included in-hospital complications such as stroke and pacemaker implantation and transcatheter heart valve hemodynamic performance. RESULTS: The number of patients with AS with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy was 328, 302, and 642, respectively. Self-expanding transcatheter heart valves were used in the majority of patients (n=1160; 91.4%). In the matched population, differences in mortality (30 days: 4.2% versus 1.7% versus 1.7%, Poverall=0.522; 1 year: 10% versus 2.3% versus 6.2%, Poverall=0.099) and all stroke (30 days: 1.0% versus 0.9% versus 0.0%, Poverall=0.765; 1 year: 1.4% versus 1.6% versus 1.3%, Poverall=NS) were nonsignificant, and the incidence of overall in-hospital complications was comparable among groups. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03-2.44]; P=0.035). The proportion of patients with a mean residual gradient ≥20 mm Hg was the highest in those with type 0 bicuspid anatomy, although the need for permanent pacemaker implantation was the lowest in this group. CONCLUSIONS: Major clinical outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy are equivalent at short- and mid-term follow-up. These observations merit further exploration in prospective international registries and randomized controlled trials.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia
4.
BMC Cardiovasc Disord ; 23(1): 354, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460957

RESUMO

BACKGROUND: We aim to determine predictors of inadequate left ventricular mass index (LVMi) regression at mid-term after transcatheter aortic valve replacement (TAVR), including the potential role of epicardial adipose tissue (EAT). METHODS: We retrospectively reviewed patients with both echocardiographic assessments and multi-slice computed tomography (MSCT) obtained one year after TAVR. The change of LVMi, the volume and the average CT attenuation of EAT from baseline to one-year follow-up was calculated. Patients were divided into two groups by the percentage change of LVMi at a cut-off of 15%. RESULTS: A total of 152 patients were included with a median age of 74 years (interquartile range [IQR] 69-78 years) and 56.6% being male. LVMi decreased (P < 0.0001) while EAT volume increased and the average CT attenuation decreased (both P < 0.0001) at one year. Baseline atrial fibrillation (P = 0.042), mitral regurgitation ≥ mild (P = 0.006), aortic regurgitation (AR) > mild (P = 0.001) and the change in the average CT attenuation of EAT (P = 0.026) were different between the decrease of LVMi ≥ 15% and < 15%. AR > mild at baseline was the only statistically significant predictor of a decrease of LVMi < 15% at one year (OR 0.33, 95% CI: 0.13 to 0.84, P = 0.021) in multivariate regression. CONCLUSIONS: Concomitant more-than-mild AR might predict better left ventricular reverse remodeling regression after TAVR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Remodelação Ventricular
6.
Nat Rev Cardiol ; 20(1): 52-67, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726019

RESUMO

Indications for transcatheter aortic valve implantation (TAVI) have expanded in many countries to include patients with aortic stenosis who are at low surgical risk, and a similar expansion to this cohort is anticipated elsewhere in the world, together with an increase in the proportion of patients with bicuspid aortic valve (BAV) morphology as the age of the patients being treated decreases. To date, patients with BAV have been excluded from major randomized trials of TAVI owing to anatomical considerations. As a consequence, BAV has been a relative contraindication to the use of TAVI in international guidelines. Although clinical experience and observational data are accumulating, BAV presents numerous anatomical challenges for successful TAVI, despite advances in device design. Furthermore, in those with BAV, substantial geographical variation exists in patient characteristics, clinical approach and procedural strategy. Therefore, in this Roadmap article, we summarize the existing evidence and provide consensus recommendations from an international group of experts on the application of TAVI in patients with BAV in advance of the anticipated growth in the use of this procedure in this challenging cohort of patients.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/etiologia , Valva Mitral , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/cirurgia , Padrões de Referência
7.
JACC Cardiovasc Interv ; 15(16): 1652-1660, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-35981839

RESUMO

BACKGROUND: It is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs). OBJECTIVES: The aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs. METHODS: In this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes. RESULTS: A total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women. CONCLUSIONS: In patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Caracteres Sexuais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Front Cardiovasc Med ; 9: 794850, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35369357

RESUMO

Objective: We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized. Method: Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. Results: A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75-0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV. Conclusions: Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.

9.
JACC Cardiovasc Interv ; 15(2): 123-134, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057982

RESUMO

OBJECTIVES: The aim of this study was to assess cusp symmetry and coronary ostial eccentricity and its impact on coronary access following transcatheter aortic valve replacement (TAVR) using a patient-specific commissural alignment implantation technique. BACKGROUND: TAVR implantation techniques to obtain neocommissural alignment have been introduced. The impact of cusp symmetry and coronary ostial eccentricity on coronary access after TAVR remains unknown. METHODS: Cardiac computed tomographic scans from 200 tricuspid aortic valves (TAVs) and 200 type 1 bicuspid aortic valves (BAVs) were studied. Cusp symmetry and coronary ostial eccentricity were assessed. In addition, the right coronary cusp/left coronary cusp and right coronary artery (RCA)/left coronary artery (LCA) ostia overlap views were calculated and compared. RESULTS: Severe cusp asymmetry (>135°) was more frequent in BAVs (52.5%) than in TAVs (2.5%) (P < 0.001), with the noncoronary cusp being the most common dominant cusp. The RCA ostium was found to be more often eccentric (>20°) than the LCA ostium (28% vs 6%, respectively; P < 0.001). Considering the right/left cusp overlap view, there was <20° deviation between the right coronary cusp-left coronary cusp centered line and the RCA-LCA centered line in 95% of all patients (TAV, 97%; BAV, 93%). The right/left cusp and coronary ostia overlap view differed by <10° and <20° fluoroscopic angulation in 75% and 98% of all cases, respectively. CONCLUSIONS: Using the right/left cusp overlap view to obtain commissural alignment in TAVR is also an effective approach to implant one of the transcatheter heart valve commissures in the near center between both coronary ostia in most TAVs and type 1 BAVs. Preprocedural CT assessment remains crucial to assess cusp symmetry and coronary ostial eccentricity.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valva Tricúspide/cirurgia
10.
BMC Cardiovasc Disord ; 21(1): 590, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876008

RESUMO

BACKGROUND: Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies. METHODS: 331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images. RESULTS: 37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5° change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48/77) of BAV patients needed less than 5° change to achieve optimal projection and only in 8 patients, the angular change was larger than 10° in either left/right anterior oblique or cranial/caudal direction. CONCLUSIONS: The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/cirurgia , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Valva Aórtica/anormalidades , Tomada de Decisão Clínica , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese
12.
Chin Med J (Engl) ; 134(22): 2678-2684, 2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34802024

RESUMO

BACKGROUND: The past decade has witnessed an ever-increasing momentum of transcatheter aortic valve replacement (TAVR) and a subsequent paradigm shift in the contemporary management of severe aortic stenosis (AS). We conducted a multi-centric TAVR registry based on Chinese patients (the China Aortic valve tRanscatheter Replacement registrY [CARRY]) to delineate the clinical characteristics and outcomes of Chinese patients who underwent TAVR and compare the results between different valve types in different Chinese regions. METHODS: CARRY is an all-comer registry of aortic valve disease patients undergoing TAVR across China and was designed as an observational study that retrospectively included all TAVR patients at each participating site. Seven hospitals in China participated in the CARRY, and 1204 patients from April 2012 to November 2020 were included. Categorical variables were compared using the chi-squared test, and continuous variables were analyzed using a t test or analysis of variance (ANOVA) test. The Kaplan-Meier curve was used to estimate the risk of adverse events during follow-up. RESULTS: The mean age of the patients was 73.8 ±â€Š6.5 years and 57.2% were male. The median Society of Thoracic Surgeon-Predicted Risk of Mortality score was 6.0 (3.7-8.9). Regarding the aortic valve, the proportion of bicuspid aortic valve (BAV) was 48.5%. During the hospital stay, the stroke rate was 0.7%, and the incidence of high-degree atrioventricular block indicating permanent pacemaker implantation was 11.0%. The in-hospital all-cause mortality rate was 2.2%. After 1 year, the overall mortality rate was 4.5%. Compared to patients with tricuspid aortic valve (TAV), those with BAV had similar in-hospital complication rates, but a lower incidence of in-hospital mortality (1.4% vs. 3.3%) and 1 year mortality (2.3% vs. 5.8%). CONCLUSIONS: TAVR candidates in China were younger, higher proportion of BAV, and had lower rates of post-procedural complications and mortality than other international all-comer registries. Given the use of early generation valves in the majority of the population, patients with BAV had similar rates of complications, but lower mortality than those with TAV. These findings further propel the extension of TAVR in low-risk patients. TRIAL REGISTRATION: https://www.chictr.org.cn/ (No. ChiCTR2000038526).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
J Biomech ; 128: 110804, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34656011

RESUMO

We sought to assess the amount and distribution of force on the valve frame after transcatheter aortic valve replacement (TAVR) via patient-specific computer simulation. Patients successfully treated with the self-expanding Venus A-Valve and multislice computed tomography (MSCT) pre- and post-TAVR were retrospectively included. Patient-specific finite element models of the aortic root and prosthesis were constructed. The force (in Newton) on the valve frame was derived at every 3 mm from the inflow and at every 22.5° on each level. Twenty patients of whom 10 had bicuspid aortic valve (BAV) were analyzed. The total force on the frame was 74.9 N in median (interquartile range 24.0). The maximal force was observed at level 5 that corresponds with the nadir of the bioprosthetic leaflets and was 9.9 (7.1) N in all patients, 10.3 (6.6) N in BAV and 9.7 (9.2) N for patients with tricuspid aortic valve (TAV). The level of maximal force located higher from the native annulus in BAV and TAV patients (8.8 [4.8] vs. 1.8 [7.4] mm). The area of the valve frame at the level of maximal force decreased from 437.4 (239.7) mm2 at the annulus to 377.6 (114.3) mm2 in BAV, but increased from 397.5 (114.3) mm2 at the annulus to 406.7 (108.9) mm2 in TAV. The maximum force on the bioprosthetic valve frame is located at the plane of the nadir of the bioprosthetic leaflets. It remains to be elucidated whether this may be associated with bioprosthetic frame and leaflet integrity and/or function.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Simulação por Computador , Análise de Elementos Finitos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
15.
Eur Radiol ; 31(8): 6220-6229, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34156556

RESUMO

OBJECTIVES: We sought to identify the impact of transcatheter aortic valve implantation (TAVI) on changes of fractional flow reserve computed tomography (FFRCT) values and the associated clinical impact. METHODS: A retrospective analysis was done with CT obtained pre-TAVI, prior to hospital discharge and at 1-year follow-up, which provided imaging sources for the calculation of FFRCT values based on an online platform. RESULTS: A total of 190 patients were enrolled. Patients with pre-procedural FFRCT value > 0.80 (i.e., negative) and ≤ 0.80 (i.e., positive) demonstrated a significantly opposite change in the value after TAVI (0.8798 vs. 0.8718, p < 0.001 and 0.7634 vs. 0.8222, p < 0.001, respectively). The history of coronary artery disease (CAD) was identified as an independent predictor for FFRCT changing from negative to positive after TAVI (odds ratio [OR] 2.927, 95% confidence interval [CI] 1.130-7.587, p = 0.027), with lesions more severely stenosed (OR 1.039, 95% CI 1.003-1.076, p = 0.034) and in left anterior descending coronary artery (LAD) (OR 3.939, 95% CI 1.060-14.637, p = 0.041) being prone to change. CONCLUSIONS: TAVI directly brings improvement in FFRCT values in patients with compromised coronary flow. Patients with a history of CAD, especially with lesions more severely stenosed and in LAD, were under risk of FFRCT changing from negative to positive after TAVI. KEY POINTS: •The effect of TAVI on coronary hemodynamics might be influenced by different ischemic severity and coronary territories reflected by FFRCT values. •As different FFRCT variations did not impact outcomes of TAVI patients, AS, but not coronary issues, may be the primary problem to affect, which needs further validation.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
17.
J Int Med Res ; 49(6): 3000605211021732, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34111997

RESUMO

Coronary artery fistula is an abnormal direct connection between the coronary artery and any of the four chambers of the heart or great vessels. A fistula from the left circumflex coronary artery to the coronary sinus is a relatively rare situation. We report a case of 12-month-old infant with coronary artery fistula from the left circumflex coronary artery to the coronary sinus that was identified incidentally. The N-terminal pro-brain natriuretic peptide level was elevated. Additionally, the proximal segment of the left circumflex coronary artery was dilated. On the basis of these findings, percutaneous closure of the fistula was performed with a vascular plug. This procedure achieved no residual flow and good hemodynamics were observed during follow-up.


Assuntos
Seio Coronário , Anomalias dos Vasos Coronários , Fístula , Cateterismo Cardíaco , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Fístula/diagnóstico por imagem , Fístula/cirurgia , Humanos , Lactente
19.
Herz ; 46(Suppl 2): 166-172, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32880663

RESUMO

BACKGROUND: Some patients referred for transcatheter aortic valve replacement (TAVR) have excessively large annuli (ELA) without device options according to current sizing charts. This retrospective study aims to summarize the presentation and outcomes of ELA patients receiving first-generation self-expanding valves. METHODS: The TAVR database was reviewed in search for cases of self-expanding valves. Patients who had annuli exceeding the perimeter limit on the device sizing chart were referred to as the ELA group. Patients who had annuli within the range covered by the two largest sizes and received the corresponding valve size served as the control group (CG). Baseline, procedures, outcomes, and imaging characteristics on multislice computed tomography (MSCT), such as native anatomy and postimplant stent geometry, were compared. RESULTS: A total of 28 patients were included in the ELA group and 82 in the CG. The patients in the ELA group were younger than those in the CG (72.5 ± 6.2 vs. 75.4 ± 5.8 years, P = 0.03). The median intended perimeter oversizing in relation to the annulus in the ELA group was much smaller than in the CG (-0.4 [-4.6, 4.1] % vs. 16.1 [11.7, 20.8] %, P < 0.01). The calcium burden in the aortic root was around 1.3-fold greater in the ELA group than the CG (756.0 [534.5, 1670.9] vs. 582.1 [310.3, 870.9] mm3, P = 0.01). The need for second valve implantation was higher in ELA (21.4% vs. 12.2%, P = 0.23) but no valve embolization was encountered. The 1­year follow-up was comparable, including >mild paravalvular leak. CONCLUSION: Under cautious patient selection using MSCT, TAVR with self-expanding valves in patients with ELA appears feasible. Supra-annular structures likely provide the extra anchoring.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA