Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Zhonghua Er Ke Za Zhi ; 62(6): 535-541, 2024 Jun 02.
Artigo em Chinês | MEDLINE | ID: mdl-38763875

RESUMO

Objective: To evaluate the diagnostic efficacy and practicality of the Jaundice color card (JCard) as a screening tool for neonatal jaundice. Methods: Following the standards for reporting of diagnostic accuracy studies (STARD) statement, a multicenter prospective study was conducted in 9 hospitals in China from October 2019 to September 2021. A total of 845 newborns who were admitted to the hospital or outpatient department for liver function testing due to their own diseases. The inclusion criteria were a gestational age of ≥35 weeks, a birth weight of ≥2 000 g, and an age of ≤28 days. The neonate's parents used the JCard to measure jaundice at the neonate's cheek. Within 2 hours of the JCard measurement, transcutaneous bilirubin (TcB) was measured with a JH20-1B device and total serum bilirubin (TSB) was detected. The Pearson's correlation analysis, Bland-Altman plots and the receiver operating characteristic (ROC) curve were used for statistic analysis. Results: Out of the 854 newborns, 445 were male and 409 were female; 46 were born at 35-36 weeks of gestational age and 808 were born at ≥37 weeks of gestational age. Additionally, 432 cases were aged 0-3 days, 236 cases were aged 4-7 days, and 186 cases were aged 8-28 days. The TSB level was (227.4±89.6) µmol/L, with a range of 23.7-717.0 µmol/L. The JCard level was (221.4±77.0) µmol/L and the TcB level was (252.5±76.0) µmol/L. Both the JCard and TcB values showed good correlation (r=0.77 and 0.80, respectively) and agreements (96.0% (820/854) and 95.2% (813/854) of samples fell within the 95% limits of agreement, respectively) with TSB. The JCard value of 12 had a sensitivity of 0.93 and specificity of 0.75 for identifying a TSB ≥205.2 µmol/L, and a sensitivity of 1.00 and specificity of 0.35 for identifying a TSB ≥342.0 µmol/L. The TcB value of 205.2 µmol/L had a sensitivity of 0.97 and specificity of 0.60 for identifying TSB levels of 205.2 µmol/L, and a sensitivity of 1.00 and specificity of 0.26 for identifying TSB levels of 342.0 µmol/L. The areas under the ROC curve (AUC) of JCard for identifying TSB levels of 153.9, 205.2, 256.5, and 342.0 µmol/L were 0.96, 0.92, 0.83, and 0.83, respectively. The AUC of TcB were 0.94, 0.91, 0.86, and 0.87, respectively. There were both no significant differences between the AUC of JCard and TcB in identifying TSB levels of 153.9 and 205.2 µmol/L (both P>0.05). However, the AUC of JCard were both lower than those of TcB in identifying TSB levels of 256.5 and 342.0 µmol/L (both P<0.05). Conclusions: JCard can be used to classify different levels of bilirubin, but its diagnostic efficacy decreases with increasing bilirubin levels. When TSB level are ≤205.2 µmol/L, its diagnostic efficacy is equivalent to that of the JH20-1B. To prevent the misdiagnosis of severe jaundice, it is recommended that parents use a low JCard score, such as 12, to identify severe hyperbilirubinemia (TSB ≥342.0 µmol/L).


Assuntos
Bilirrubina , Hiperbilirrubinemia Neonatal , Icterícia Neonatal , Sensibilidade e Especificidade , Humanos , Recém-Nascido , Bilirrubina/sangue , Estudos Prospectivos , Feminino , Masculino , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/sangue , Icterícia Neonatal/diagnóstico , Icterícia Neonatal/sangue , Curva ROC , Triagem Neonatal/métodos , Idade Gestacional , Pais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA