Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Front Oncol ; 12: 939948, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992857

RESUMO

Hepatocellular carcinoma (HCC) is the most common type of primary liver cancer and has a high recurrence rate. Accurate prediction of recurrence risk is urgently required for tailoring personalized treatment programs for individual HCC patients in advance. In this study, we analyzed a gene expression dataset from an HCC cohort with 247 samples and identified five genes including ENY2, GPAA1, NDUFA4L2, NEDD9, and NRP1 as the variables for the prediction of HCC recurrence, especially the early recurrence. The Cox model and risks score were validated in two public HCC cohorts (GSE76427 and The Cancer Genome Atlas (TCGA)) and one cohort from Huashan Hospital, which included a total of 641 samples. Moreover, the multivariate Cox regression analysis revealed that the risk score could serve as an independent prognostic factor in the prediction of HCC recurrence. In addition, we found that ENY2, GPAA1, and NDUFA4L2 were significantly upregulated in HCC of the two validation cohorts, and ENY2 had significantly higher expression levels than another four genes in malignant cells, suggesting that ENY2 might play key roles in malignant cells. The cell line analysis revealed that ENY2 could promote cell cycle progression, cell proliferation, migration, and invasion. The functional analysis of the genes correlated with ENY2 revealed that ENY2 might be involved in telomere maintenance, one of the fundamental hallmarks of cancer. In conclusion, our data indicate that ENY2 may regulate the malignant phenotypes of HCC via activating telomere maintenance.

2.
Technol Health Care ; 30(2): 445-454, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34657862

RESUMO

BACKGROUND: In the past ten years, liver biopsies have been used as a method to accurately diagnose the stage of fibrosis. OBJECTIVE: This study aimed to evaluate whether body position and exercise affect the measurement of liver Young's modulus of healthy volunteers by real-time shear wave elastography (RT-SWE). METHODS: RT-SWE was used to measure liver Young's modulus in the supine and left lateral positions of 70 healthy volunteers at rest and measure the liver Young's modulus in the lying position before exercise, and at zero, five, and ten minutes of rest after exercise. RESULTS: The liver Young's modulus in the left lateral position was significantly higher than in the supine position (P< 0.05), and the measured value in the supine position was more stable than the left lateral position. The liver Young's modulus measured at zero minutes after exercise was significantly higher than that measured before exercise (P< 0.05). The liver Young's modulus measured at five minutes after exercise was significantly higher than that measured at zero minutes after exercise (P<0.05) and was not statistically different from the measured value before exercise (P> 0.05). The liver Young's modulus measured at ten minutes after exercise was significantly higher from that measured at zero minutes after exercise (P< 0.05) and was not statistically different from the measured value at five minutes after exercise (P> 0.05). CONCLUSION: Body position and exercise have a significant impact on the measurement of liver Young's modulus. It is recommended that the examinees take a supine position during the measurement, and measurement should be conducted at least ten minutes after exercise.


Assuntos
Técnicas de Imagem por Elasticidade , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Exercício Físico , Humanos , Fígado/diagnóstico por imagem , Postura
3.
Int J Gen Med ; 14: 7971-7981, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34795512

RESUMO

OBJECTIVE: This study aims to explore the feasibility of HeartModel A.I. (HM) three-dimensional echocardiography (3DE) to assess left ventricular function and discover suitable border parameter settings. METHODS: A total of 113 patients that underwent echocardiography in our hospital were eligible for inclusion. The HM 3DE (HM method) and conventional 3DE (3D method) were used to analyze echocardiography images. The HM was set to different border settings (end-diastolic [ED] and end-systolic [ES] settings) to assess different left ventricular systolic function parameters including left ventricular end diastolic volume (LVEDV), left ventricular end systolic volume (LVESV), and left ventricular ejection fraction (LVEF), and left ventricular diastolic function parameters including maximal left atrium volume (LAVMAX). All of these parameters were evaluated using the HM method and then compared with the 3D method. RESULTS: The differences in LVEDV, LVESV, and LVEF measured with different HM border settings were statistically significant (P<0.05) and were strongly correlated with the 3D method. For LVEF, the reading using the HM method with ED and ES = 70 and 30 showed the best agreement with the 3D method, and the difference in the readings was not statistically significant (P > 0.05). For LVEDV and LVESV, the reading using the HM method with ED and ES = 40 and 20 showed the best agreement with the 3D method, but the difference in the readings was statistically significant (P < 0.05). The measurements taken using the HM method were more reproducible than those taken using the 3D method (P<0.05). The measurement time when using the HM method was significantly less than the 3D method (P<0.05). In terms of LAVMAX, the correlation between the HM and 3D methods was strong, but the requirements for agreement were not satisfied. CONCLUSION: Evaluation of the left ventricular function using HM 3DE is feasible, saves time, and is reproducible. To assess the left ventricular function, the border parameter setting of ED and ES = 70 and 30 provided the best fit for the Chinese population.

4.
J Am Soc Echocardiogr ; 34(6): 629-641, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33422666

RESUMO

BACKGROUND: Ultrafast ultrasound imaging has been demonstrated to be an effective method to evaluate carotid stiffness through carotid pulse-wave velocity (PWV) with high reproducibility, but a lack of reference values has precluded its widespread use in clinical practice. The aims of this study were to establish reference values of PWV for ultrafast ultrasound imaging in a prospective, multicenter, population-based cohort study and to investigate the main determinants of carotid PWV. METHODS: A total of 1,544 healthy Han Chinese volunteers (581 men [38%]; age range, 18-95 years) were enrolled from 32 collaborating laboratories in China. The participants were categorized by age, blood pressure (BP), and body mass index (BMI). Basic clinical parameters and carotid PWV at the beginning of systole (BS) and at end-systole (ES) were measured using ultrafast ultrasound imaging techniques. RESULTS: PWV at both BS and ES was significantly higher in the left carotid artery than in the right carotid artery. PWV at BS was significantly higher in men than in women; however, no significant difference was noted in PWV at ES between men and women. Multiple linear regression analyses revealed that age, BP, and BMI were independently correlated with PWV at both BS and ES. PWV at BS and ES progressively increased with increases in age, BP, and BMI. Furthermore, age- and sex-specific reference values of carotid PWV for ultrafast ultrasound imaging were established. CONCLUSIONS: Reference values of carotid PWV for ultrafast ultrasound imaging, stratified by sex and age, were determined for the first time. Age, BP, and BMI were the dominant determinants of carotid PWV for ultrafast ultrasound imaging, which should be considered in clinical practice for assessing arterial stiffness.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Artérias Carótidas/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
5.
J Fluoresc ; 30(5): 1241-1250, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32761418

RESUMO

[Zn(dima)(H2O)0.5]·H2O (1), a three-dimensional metal organic framework (MOF) with high porosity was formed by self-assembly of 4,6-di(1 h-imidazol-1-yl)isophthalic acid (H2dima) and Zn2+ ion. Owning to its excellent luminescence and excellent water stability, complex 1 can be used as a super sensitive sensor to detect Fe3+ ions via the behaviors of fluorescence quenching. At the same time, the mechanism for the fluorescence quenching is also further discussed. Furthermore, the prevention effect of the compound on the deep vein thrombosis of the lower extremities (DVT) after lower venous CHIVA surgery was evaluated in vivo. Firstly, the DVT animal models was constructed and the number of platelets was measured with flow cytometry and content of clotting factor IX and anticoagulant factor III was also detected with Lowry method after compound treatment. The molecular docking simulation results indicate that the Zn(II) complex has activity to protein docking pocket with different sizes.


Assuntos
Fatores de Coagulação Sanguínea/análise , Complexos de Coordenação/farmacologia , Corantes Fluorescentes/farmacologia , Estruturas Metalorgânicas/farmacologia , Trombose Venosa/prevenção & controle , Zinco/farmacologia , Animais , Plaquetas/efeitos dos fármacos , Complexos de Coordenação/síntese química , Complexos de Coordenação/química , Modelos Animais de Doenças , Compostos Férricos/análise , Corantes Fluorescentes/síntese química , Corantes Fluorescentes/química , Íons/análise , Extremidade Inferior/cirurgia , Estruturas Metalorgânicas/síntese química , Estruturas Metalorgânicas/química , Simulação de Acoplamento Molecular , Contagem de Plaquetas , Ratos , Trombose Venosa/cirurgia , Água/química , Zinco/química
6.
J Cancer ; 11(13): 3903-3909, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32328194

RESUMO

Objectives: To assess the performance of elastography (ES) and ultrasound (US) in predicting the malignancy of breast lesions and to compare their combined diagnostic value with that of magnetic resonance imaging (MRI). Materials and Methods: The study prospectively enrolled 242 female patients with dense breasts treated in 35 heath care facilities in China between November 2018 and October 2019. Based on conventional US and elastography, radiologists classified the degree of suspicion of breast lesions according to the US Breast Imaging Reporting and Data System (BI-RADS) criteria. The diagnostic value was compared between US BI-RADS and MRI BI-RADS, with pathological results used as the reference standard. Results: The results demonstrated that irregular tumor shape, a nonparallel growth orientation, indistinct margins, angular contours, microcalcifications, color Doppler flow and ES score on US imaging were significantly related to breast cancer in dense breasts (P=0.001; P=0.001; P=0.008; P<0.001; P=0.019; P=0.008; P=0.002, respectively). The sensitivity, specificity, PPV, NPV, accuracy and AUC of US BI-RADS category were 94.7%, 90.7%, 95.8%, 88.0%, 93.4% and 0.93 (95%CI, 0.88-0.97), respectively, while those of MRI BI-RADS category were 98.2%, 57.5%, 84.3%, 83.3%, 86.0% and 0.78 (95%CI, 0.71-0.85), respectively. MRI BI-RADS showed a significantly higher sensitivity than US BI-RADS (98.2% vs 94.7%, P=0.043), whereas US BI-RADS showed significantly higher specificity (90.7% vs 57.5%, P<0.001). US BI-RADS showed better diagnostic efficiency in differentiating nodules in dense breasts than MRI BI-RADS (AUC 0.93 vs 0.78, P<0.001). Conclusion: By combining the use of ES and conventional US, US BI-RADS had better diagnostic efficiency in differentiating nodules in dense breasts than MRI. For the diagnosis of malignant tumors in patients with dense breasts, MRI and US BI-RADS can be used as supplemental diagnostic tools to detect lesions, with US BI-RADS considered the preferred adjunctive resource.

7.
Medicine (Baltimore) ; 98(4): e14258, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30681622

RESUMO

OBJECTIVE: Recent reports have suggested that contrast-enhanced ultrasound (CEUS) can be used to monitor the pathologic responses of breast cancer (BC) to neoadjuvant chemotherapy (NAC); however, the diagnostic performance of CEUS in BC has yet to be confirmed. Thus, we conducted a meta-analysis of related studies to explore the relationship between CEUS and pathologic responses of BC to NAC. MATERIALS AND METHODS: We searched PubMed, Embase, Web of Science, ScienceDirect, and China National Knowledge Infrastructure databases for studies published until September 31, 2018. Study-specific odds ratios (ORs) and 95% confidence intervals (CIs) were calculated, and then ORs with 95% CIs were pooled to estimate the prognostic role of CEUS for the pathologic responses of BC to NAC. RESULTS: Pooled meta-analysis of the 9 eligible studies that included 424 patients indicated the high performance of CEUS for monitoring pathologic responses to NAC (OR = 31.83, 95% CI: 16.69-60.67, P < .001), with no significant heterogeneity (I = 0.0%, P = .529). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 87% (95% CI: 0.81-0.92), 84% (95% CI: 0.74-0.91), 5.5 (95% CI: 3.3-9.2), 0.15 (95% CI: 0.10-0.23), and 36 (95% CI: 18-70), respectively. An area under the curve of 0.92 (95% CI: 0.89-0.94) suggests a high ability for prognostic detection. Although Begg's funnel plot (P = .057) indicated the presence of publication bias among the included studies, the trim-and-fill method verified the stability of the pooled outcomes. Sensitivity analysis suggested that the pooled OR was robust. CONCLUSION: Our results suggest that CEUS has a high diagnostic performance for the pathologic responses of BC to NAC. Further and better-designed studies should be performed to verify the clinical applications of CEUS for monitoring BC responses to NAC.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Meios de Contraste , Avaliação de Resultados em Cuidados de Saúde/métodos , Ultrassonografia/métodos , Adulto , Quimioterapia Adjuvante , Feminino , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Razão de Chances , Sensibilidade e Especificidade , Resultado do Tratamento
8.
Clin Hemorheol Microcirc ; 72(1): 39-60, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30320562

RESUMO

Ultrasound elastography has been introduced into clinical practice for a decade and arisen continuous increasing attention worldwide. Shear wave elastography (SWE) is a further extension of ultrasound elastography on the basis of strain elastography, providing a two-dimensional distribution map of tissue stiffness and quantitative measurement of the tissue stiffness in Young's modulus (kPa) and/or shear wave speed (m/s). The Society of Ultrasound in Medicine, Chinese Medical Association (CMA) has recently released a series of guidelines for the use of SWE, including the technique and principle of SWE, and use of SWE in liver fibrosis, breast, thyroid, and musculoskeletal system. Herein, a part of SWE in thyroid nodules is presented. In this guideline, the background, classification and technology of SWE, examination methods, diagnostic performance, prognosis evaluation, reproducibility, and limitations are discussed and recommendations are given. The recommendations are based on the published literatures with regard to SWE with different levels of evidence, particularly a mid-term result of the prospective multi-center clinical trial of SWE in thyroid, as well as the Society of Ultrasound in Medicine, CMA expert's consensus. The document provides an overall analysis of SWE in thyroid from clinical perspective, which aimed to provide recommendations to the clinicians with regard to the management of thyroid nodules by the assistance of SWE.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico , Guias como Assunto , Humanos , Estudos Prospectivos , Nódulo da Glândula Tireoide/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA